Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A NUMERICAL SIMULATION OF COSMIC RAY MODULATION NEAR THE HELIOPAUSE. II. SOME PHYSICAL INSIGHTS

Cosmic ray (CR) transport near the heliopause (HP) is studied using a hybrid transport model, with the parameters constrained by observations from the Voyager 1 spacecraft. We simulate the CR radial flux along different directions in the heliosphere. There is no well-defined thin layer between the solar wind region and the interstellar region along the tail and polar directions of the heliosphere. By analyzing the radial flux curve along the direction of Voyager 2 , together with its trajectory information, the crossing time of the HP by Voyager 2 is predicted to be in 2017.14. We simulate the CR radial flux for different energy values along the direction of Voyager 1 . We find that there is only a modest modulation region of about 10 au wide beyond the HP, so that Voyager 1 observing the Local Interstellar Spectra is justified in numerical modeling. We analyze the heliospheric exit information of pseudo-particles in our stochastic numerical (time-backward) method, conjecturing that they represent the behavior of CR particles, and we find that pseudo-particles that have been traced from the nose region exit in the tail region. This implies that many CR particles diffuse directly from the heliospheric tail region to the nose region near the HP. In addition, when pseudo-particles were traced from the Local Interstellar Medium (LISM), it is found that their exit location (entrance for real particles) from the simulation domain is along the prescribed Interstellar Magnetic Field direction. This indicates that parallel diffusion dominates CR particle transport in the LISM.

79 ASTRONOMY AND ASTROPHYSICS↗

CFD Modeling and Image Analysis of Exhaled Aerosols due to a Growing Bronchial Tumor: towards Non-Invasive Diagnosis and Treatment of Respiratory Obstructive Diseases

Diagnosis and prognosis of tumorigenesis are generally performed with CT, PET, or biopsy. Such methods are accurate, but have the limitations of high cost and posing additional health risks to patients. In this study, we introduce an alternative computer aided diagnostic tool that can locate malignant sites caused by tumorigenesis in a non-invasive and low-cost way. Our hypothesis is that exhaled aerosol distribution is unique to lung structure and is sensitive to airway structure vari-ations. With appropriate approaches, it is possible to locate the disease site, determine the disease severity, and subsequently formulate a targeted drug delivery plan to treat the disease. This study numerically evaluated the feasibility of the proposed breath test in an image-based lung model with varying pathological stages of a bronchial squamous tumor. Large eddy simulations and a Lagran-gian tracking approach were used to model respiratory airflows and aerosol dynamics. Respira-tions of tracer aerosols of 1 µm at a flow rate of 20 L/min were simulated, with the distributions of exhaled aerosols recorded on a filter at the mouth exit. Aerosol patterns were quantified with multiple analytical techniques such as concentration disparity, spatial scanning and fractal analysis. We demonstrated that a growing bronchial tumor induced notable variations in both the airflow and exhaled aerosol distribution. These variations became more apparent with increasing tumor severity. The exhaled aerosols exhibited distinctive pattern parameters such as spatial probability, fractal dimension, and multifractal spectrum. Results of this study show that morphometric measures of the exhaled aerosol pattern can be used to detect and monitor the pathological states of respiratory diseases in the upper airway. The proposed breath test also has the potential to locate the site of the disease, which is critical in developing a personalized, site-specific drug de-livery protocol.

Aerosol breath test↗

The Ki-67 and RepoMan mitotic phosphatases assemble via an identical, yet novel mechanism

Ki-67 and RepoMan have key roles during mitotic exit. Previously, we showed that Ki-67 organizes the mitotic chromosome periphery and recruits protein phosphatase 1 (PP1) to chromatin at anaphase onset, in a similar manner as RepoMan. Here we show how Ki-67 and RepoMan form mitotic exit phosphatases by recruiting PP1, how they distinguish between distinct PP1 isoforms and how the assembly of these two holoenzymes are dynamically regulated by Aurora B kinase during mitosis. Unexpectedly, our data also reveal that Ki-67 and RepoMan bind PP1 using an identical, yet novel mechanism, interacting with a PP1 pocket that is engaged only by these two PP1 regulators. These findings not only show how two distinct mitotic exit phosphatases are recruited to their substrates, but also provide immediate opportunities for the design of novel cancer therapeutics that selectively target the Ki-67:PP1 and RepoMan:PP1 holoenzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Pressure Distribution Induced on a Flat Plate at a Free-Stream Mach Number of 1.39 by Rockets Exhausting Upstream and Downstream

An experimental investigation was made of the pressures induced on a flat plate at a free-stream Mach number of 1.39 by a supersonic rocket jet exhausting upstream and downstream. Measurements of the pressure distribution on a flat plate were made at zero angle of attack for 11 different locations of the jet exhaust nozzle beneath the wing. Measurements were made at ratios of rocket-exit total pressure to freestream static pressure from 6 to 60 and at a Reynolds number per foot of approximately 10 x 10 6 . The rocket when exhausted upstream produced a strong shock that moved further upstream with increasing rocket-exit total-pressure ratio. Positive incremental normal-force coefficients were obtained at all test positions. Data at 11 test positions are tabulated for rocket-on and rocket-off pressure coefficients as well as for incremental pressure coefficients for the 48 orifices of the flat plate for the range of ratio of rocket-exit total pressure to free-stream static pressure of the investigation. Changing the location of the model with respect to the plate had a negligible effect when the rocket was varied in the chordwise direction, but the pressure coefficients were reduced as the rocket was lowered away from the flat-plate wing.

Supersonic jet↗

Design and two dimensional cascade test of a jet-flap turbine stator blade with ratio of axial chord to spacing of 0.5

A jet-flap blade was designed for a velocity diagram typical of the first-stage stator of a jet engine turbine and was tested in a simple two-dimensional cascade of six blades. The principal measurements were blade surface static pressure and cross-channel surveys of exit total pressure, static pressure, and flow angle. The results of the experimental investigation include blade loading, exit angle, flow, and loss data for a range of exit critical velocity ratios and three jet flow conditions.

Stabe, R. G.↗

Flight investigation of an underwing nacelle installation of three variable-flap ejector nozzles

A modified F-106B aircraft with underwing engine nacelles was flight tested to investigate airframe installation effects on ejector nozzles. Nozzle thrust coefficients, boattail drag coefficients, and boundary layer characteristics were obtained for the three nozzles. All the nozzles were geometrically similar and had 15 deg conical boattails with juncture radii of curvature equal to 0.5 maximum nozzle diameter. The effects of boattail location relative to the wing trailing edge and the ejector to primary nozzle exit diameter ratio were investigated. Shortening the length by 0.48 nozzle diameter lowered the transonic boattail drag rise Mach number from 0.97 to 0.95. Decreasing the nozzle exit diameter, which reduced the ejector to primary nozzle exit diameter ratio from 1.30 to 1.18, increased the gross thrust coefficient 4.8 percent.

Head, V. L.↗

Static performance of a 13.97 cm (5.5 inch) diameter model VTOL lift fan

A tip-turbine-driven fan of the type currently being used in wind tunnel tests of VTOL lift fan models was tested. Values of thrust, weight flow, exit total and static pressure, exit swirl angle, and turbine temperature drop were measured as a function of fan speed for several inlet and exit configurations. A standard fan performance map was also obtained.

Lowe, W. H.↗

Experimental dynamic response of a two-dimensional, Mach 2.7, mixed compression inlet

A test program was conducted on a two-dimensional supersonic inlet. Internal disturbances in diffuser exit mass flow were produced by oscillating overboard bypass doors. Open-loop dynamic responses of shock position, throat exit and diffuser exit static pressures are presented. The steady-state and dynamic coupling between ducts were also obtained. The experimental results from the two-dimensional inlet are compared to results from a similar size axisymmetric inlet and also to a transfer function synthesis program.

Baumbick, R. J.↗

Nuclear light bulb propellant heating simulation using a tungsten/argon aerosol and radiation from a dc arc surrounded by a segmented mirror cavity

Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).

Klein, J. F.↗

Aerodynamic performance of a core-engine turbine stator vane tested in a two-dimensional cascade of 10 vanes and in a single vane tunnel

A turbine stator vane was tested in a two-dimensional cascade of 10 vanes and in a single-vane tunnel. The single-vane tunnel was a cold air version of a tunnel which will be used for high temperature heat transfer testing of cooled turbine vanes. The purpose of the investigation was to determine if the flow conditions in the single-vane tunnel were sufficiently similar to those of a 10-vane cascade to permit meaningful heat transfer testing. The vane was tested over a range of ideal exit critical velocity ratios. The principal measurements were vane surface static pressure and cross-channel surveys of exit static pressure, total pressure, and flow angle. A brief description of the test vane and tunnels is included. The results of the exit surveys, the vane surface pressure distributions, and overall performance in terms of flow and loss for the two test configurations are compared.

Stabe, R. G.↗

Incidence loss for a core turbine rotor blade in a two-dimensional cascade

The effect of incidence angle on the aerodynamic performance of an uncooled core turbine rotor blade was investigated experimentally in a two-dimensional cascade. The cascade test covered a range of incidence angles from minus 15 deg to 15 deg in 5-degree increments and a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95. The principal measurements were blade-surface static pressures and cross-channel surveys of exit total pressure, static pressure, and flow angle. The results of the investigation include blade-surface velocity distribution and overall performance in terms of weight flow and loss for the range of incidence angles and exit velocity ratios investigated. The measured losses are also compared with two common methods of predicting incidence loss.

Stabe, R. G.↗

Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

Flow studies in a wet steam turbine

The design and test results of a four stage wet vapor turbine operating with slightly superheated inlet steam and expanding to 10% exit moisture are presented. High speed movies at 3000 frames per second of liquid movement on the pressure side and along the trailing edge of the last stator blade are discussed along with back lighted photographs of moisture drops as they were torn from the stator blade trailing edge. Movies at lower framing rates were also taken of the exit of the last rotating blade and the casing moisture removal slot located in line with the rotor blade shroud. Also moisture removal data are presented of casing slot removal at the exit of the third and fourth rotor blades and for slots located in the trailing edge of the last stator blade. Finally, the degradation of turbine thermodynamic performance due to condensation formation and movement is discussed.

Evans, D. H.↗

Aerodynamic performance of a ceramic-coated core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a core turbine vane with a ceramic coating was investigated experimentally in a two-dimensional cascade of 10 vanes. The vane was first tested with a rough coating and then retested after the coating had been smoothed. The test fluid was atmospheric air. The cascade tests covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey results and overall performance in terms of flow angle, weight flow, and kinetic energy loss. The performance of the ceramic-coated vanes is compared with the performance of an uncoated vane having a similar profile.

Stabe, R. G.↗

Performance of vortex generators in a Mach 2.5 low-bleed full scale 45-percent-internal-contraction axisymmetric inlet

Steady-state and dynamic flow characteristics associated with two sets of vortex generators having different mixing criteria were determined. The inlet performance with and without these vortex generators is presented. The vortex generators were successful in eliminating separation, increasing area-weighted total pressure recovery, and decreasing distortion. Transmission times obtained from cross-correlations of the wall static pressures and the diffuser exit total pressure showed no effect of the upstream flow characteristics on the diffuser exit pressures when generators were used. Without generators, separation occurred and the upstream pressure characteristics had immediate effects on the diffuser exit pressure characteristics.

Neumann, H. E.↗

Center-line velocity decay in coaxial free jets

The effects of initial nonuniformities in the exit velocity profiles of incompressible coaxial air jets expelled into free air on the fully developed region of the jets is studied experimentally. The primary and annular jet exit velocities were nonuniform, and the average velocity of the primary jet was greater than that of the annular jet. The center-line velocity of the jet in the fully developed region is found to depend on the primary jet exit velocity profile and on the ratio of the central to annular jet average velocities.

Lenzo, C. S.↗

Design, fabrication and acoustic tests of a 36 inch (0.914 meter) statorless turbotip fan

The LF336/E is a 36 inch (0.914 meter) diameter fan designed to operate in a rotor-alone configuration. Design features required for modification of the existing LF336/A rotor-stator fan into the LF336/E statorless fan configuration are discussed. Tests of the statorless fan identified an aerodynamic performance deficiency due to inaccurate accounting of the fan exit swirl during the aerodynamic design. This performance deficiency, related to fan exit static pressure levels, produced about a 20 percent thrust loss. A study was then conducted for further evaluation of the fan exit flow fields typical of statorless fan systems. This study showed that through proper selection of fan design variables such as pressure ratio, radius ratio, and swirl distributions, performance of a statorless fan configuration could be improved with levels of thrust approaching the conventional rotor-stator fan system. Acoustic measurements were taken for the statorless fan system at both GE and NASA, and when compared to other lift fan systems, showed noise levels comparable to the quietest lift fan configuration which included rotor-stator spacing and acoustic treatment. The statorless fan system was also used to determine effects of rotor leading edge serrations on noise generations. A cascade test program identified the serration geometry based on minimum pressure losses, wake turbulence levels and noise generations.

Smith, E. G.↗

Swirl-can combustor performance to near-stoichiometric fuel-air ratio

Emissions and performance characteristics were determined for full-annulus swirl-can modular combustors operated to near stoichiometric fuel air ratios. The purposes of the tests were to obtain stoichiometric data at inlet air temperatures up to 894 K and to determine the effect of module number by investigating 120 and 72 module swirl-can combustors. The maximum average exit temperature obtained with the 120-module swirl-can combustor was 2465 K with a combustion efficiency of 95 percent at an inlet-air temperature of 894 K. The 72-module swirl-can combustor reached a maximum average exit temperature of 2306 K with a combustion efficiency of 92 percent at an inlet air temperature of 894 K. At a constant inlet air temperature, maximum oxides of nitrogen emission index values occurred at a fuel-air ratio of 0.037 for the 72-module design and 0.044 for the 120-module design. The combustor average exit temperature and combustion efficiency were calculated from emissions measurements. The measured emissions included carbon monoxide, unburned hydrocarbons, oxides of nitrogen, and smoke.

Diehl, L. A.↗