Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Geothermal Fault Zone and Fluid Imaging through Joint Airborne ZTEM and Ground MT Data Inversion Analysis

This project has aimed to achieve detailed electrical resistivity resolution at geothermal reservoir scales by combining airborne natural electromagnetic (EM) field surveying (ZTEM) with ground magnetotelluric (MT) measurements to approximate an airborne MT geophysical method. MT alone is relatively expensive and may have permitting challenges in sensitive areas. Airborne ZTEM field data contains only the magnetic field, requires a background assumption, and has been limited to relatively high frequencies, thus suffering uniqueness problems. Based on proto-type 2D simulations, ZTEM ambiguities may be reduced through formal incorporation with possibly sparse ground MT soundings, which we pursued in full 3D for this project. The methodology was tested at the high-temperature Roosevelt Hot Springs geothermal system, Utah, which was considered advantageous given the near total exposure of crystalline reservoir rocks across the project area. ZTEM and ground MT survey data were acquired in 2017, subcontracted to outside parties with which we have worked in the past. These included 80 remote-referenced tensor MT soundings over the Mineral Mountains and adjacent Roosevelt Hot Spring producing geothermal system. These MT stations abut later coverage of a similar number of MT stations taken for the Utah FORGE project providing excellent total data aperture to re-solve structure beneath both project areas better than either set alone. The airborne ZTEM survey covered 704 line kilometers in E-W flight lines with a 250 m line spacing. Although this survey was timed during a maintenance-related shutdown of power production at the Roosevelt Hot Springs, other noise sources difficult to identify but including two high-voltage state-scale transmission lines compromised the ZTEM survey badly leading to unusable responses. Thus, with DOE management concurrence, the project proceeded to emphasize inversion and interpretation of the joint SubTER-FORGE MT data sets with regard to the Roosevelt Hot Springs reservoir recharge and to deep heat sources for both it and the Utah FORGE EGS project area. We also investigated the joint ZTEM-MT sampling concept with data sets from the Eleven Mile Canyon prospect area donated by the U.S. Navy (A. Sabin, PoC). Inversion of the SubTER-FORGE MT data using the HexMT 3D finite element algorithm reveals a large, low-resistivity anomaly extending sub-vertically through the depth range of the crust beneath the western Mineral Mountains. The steep conductive zone connects in the lower crust to a more tabular conductor characteristic of much of the Great Basin that generally is ascribed to current mafic magmatic underplating, hybridization and fluid release. The location of the resolved anomaly relative to the recent (0.5-0.8 Ma) eruptive centers of the Mineral Mountains implicates it as remnants of the magma body which fed these centers. This structure appears to be currently feeding heat and fluids upward into the Roosevelt Hot Springs hydrothermal system, as well as heat laterally to the FORGE project area. Separate and joint inversion models were carried out for the donated Eleven Mile Canyon MT-ZTEM data set to demonstrate concept. ZTEM only inversion showed two main alteration zones in the western portion of the project area known from geological mapping. Joint inversion including an E-W profile of MT soundings sharpened these features considerably. It also resolved in much greater detail the graben related normal faulting structure of the central project area which lies at depths exceeding the sensitivity of ZTEM alone. The sparse number of MT da-ta relative to the ZTEM required upweighting the former by a factor of several, but an exact procedure awaits future research. Our final impression is that sparse MT data can improve resolution of the subsurface over that of ZTEM alone. However, well sampled MT data are to be preferred and offer the simplicity of interpreting just one data type, and possess the superior resolution capability coming with the electric field everywhere, and from their high bandwidth.

15 GEOTHERMAL ENERGY↗

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Organic-semiconducting hybrid solar cell

The embodiment of this invention lies on experimental evidence of photoconductivity activity of a hybrid solar cell, organic/chalcogenide. The device is made of thin layers of conductive indium-tin-oxide (ITO) on glass with a 100 nm layer of chalcogenide molybdenum di-sulfide (MoS 2 ) and a thin layer of about ˜50 nm of complex organic compound assembled at room temperature. The device was tested to conventional electrical transport measurements in the regime of −1V to 1V under electromagnetic radiation simulator at 100 mW/cm 2 . Results indicate solar conversion efficiency of 2.48% and current density of 6.35 mA/cm 2 .

14 SOLAR ENERGY↗

Fact Sheet - Long-length Scintillating Fibers for Radiation Detection

As the world looks to underground geological repositories for storing nuclear waste, technologies to safeguard the material are needed. An example of a project that developed a new technology is Tripwire. Tripwire proposes a multi-sensor system approach for geological spent nuclear fuel repositories that relies of radiation, vibration, and electromagnetic detection. Tripwire was developed by the Applied Radiation Measurements and Systems (ARMS) group at INL and sponsored by the National Nuclear Security Administration (NNSA). The ARMS group performs research and development, testing and evaluation, operational support, and training focused on applied ionizing radiation detection and measurement. Application areas include nuclear engineering for advanced reactors and fuel cycle operations, nuclear nonproliferation, nuclear counterproliferation, nuclear forensics, and arms control and disarmament.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

A modified Bitter-type electromagnet and control system for cold atom experiments

We present a modified Bitter-type electromagnet which features high magnetic field, fine electronic properties and efficient heat removal. The electromagnet is constructed from a stack of copper layers separated by mica layers that have the same shape. A distinctive design of cooling channels on the insulating layers and the parallel ducts between the layers ensures low resistance for cooling water to flow. A continuous current control system is also made to regulate the current through the electromagnet. In our experiment, versatile electromagnets are applied to generate magnetic field and gradient field. From our measurements, a peak magnetic field of 1000 G and a peak gradient field of 80 G/cm are generated in the center of the apparatuses which are 7 cm and 5 cm away from the edge of each electromagnet with a current of 230 A and 120 A, respectively. With the effective feedback design in the current control system and cooling water flow of 3.8 l/min, the stability of the current through the electromagnets can reach 10{sup −5}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Construction and performance of the barrel electromagnetic calorimeter for the Gluex experiment

The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described in this paper. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. Finally, we characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for π 0 and η production of σ E / E = 5 . 2 % / E ( GeV ) ⊕ 3 . 6 % and a timing resolution of σ = 150 ps at 1 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of a novel technique to measure two-photon exchange effects in elastic e±p scattering

The discrepancy between proton electromagnetic form factors extracted using unpolarized and polarized scattering data is believed to be a consequence of two-photon exchange (TPE) effects. However, the calculations of TPE corrections have significant model dependence, and there is limited direct experimental evidence for such corrections. The TPE contributions depend on the sign of the lepton charge in e±p scattering, but the luminosities of secondary positron beams limited past measurement at large scattering angles, where the TPE effects are believe to be most significant. We present the results of a new experimental technique for making direct e±p comparisons, which has the potential to make precise measurements over a broad range in Q 2 and scattering angles. We use the Jefferson Laboratory electron beam and the Hall B photon tagger to generate a clean but untagged photon beam. The photon beam impinges on a converter foil to generate a mixed beam of electrons, positrons, and photons. A chicane is used to separate and recombine the electron and positron beams while the photon beam is stopped by a photon blocker. This provides a combined electron and positron beam, with energies from 0.5 to 3.2 GeV, which impinges on a liquid hydrogen target. The large acceptance CLAS detector is used to identify and reconstruct elastic scattering events, determining both the initial lepton energy and the sign of the scattered lepton. The data were collected in two days with a primary electron beam energy of only 3.3 GeV, limiting the data from this run to smaller values of Q 2 and scattering angle. Nonetheless, this measurement yields a data sample for e±p with statistics comparable to those of the best previous measurements. We have shown that we can cleanly identify elastic scattering events and correct for the difference in acceptance for electron and positron scattering. Because we ran with only one polarity for the chicane, we are unable to study the difference between the incoming electron and positron beams. This systematic effect leads to the largest uncertainty in the final ratio of positron to electron scattering: R=1.027±0.005±0.05 for < Q 2 >=0.206 GeV 2 and 0.830 ≤ ε ≤ 0.943. We have demonstrated that the tertiary e ± beam generated using this technique provides the opportunity for dramatically improved comparisons of e±p scattering, covering a significant range in both Q 2 and scattering angle. Combining data with different chicane polarities will allow for detailed studies of the difference between the incoming e + and e - beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of beam-induced plasma for the mitigation of beam-beam effects

One of the main challenges in the increase of luminosity of circular colliders is the control of the beam-beam effect. In the process of exploring beam-beam mitigation methods using plasma, we evaluated the possibility of plasma generation via ionization of neutral gas by proton beams, and performed highly resolved simulations of the beam-plasma interaction using SPACE, a 3D electromagnetic particle-in-cell code. The process of plasma generation is modelled using experimentally measured cross-section coefficients and a plasma recombination model that takes into account the presence of neutral gas and beam-induced electromagnetic fields. Numerically simulated plasma oscillations are consistent with theoretical analysis. In the beam-plasma interaction process, high-density neutral gas reduces the mean free path of plasma electrons and their acceleration. A numerical model for the drift speed as a limit of plasma electron velocity was developed. Simulations demonstrate a significant reduction of the beam electric field in the presence of plasma. Preliminary simulations using fully-ionized plasma have also been performed and compared with the case of beam-induced plasma.

43 PARTICLE ACCELERATORS↗

Measurement of elastic pp scattering at $\sqrt{\hbox {s}} = \hbox {8}$ TeV in the Coulomb–nuclear interference region: Determination of the ρ-parameter and the total cross-section

Here, the TOTEM experiment at the CERN LHC has measured elastic proton–proton scattering at the centre-of-mass energy s√=8TeV and four-momentum transfers squared, |t|, from 6 × 10 –4 to 0.2 GeV 2 . Near the lower end of the t-interval the differential cross-section is sensitive to the interference between the hadronic and the electromagnetic scattering amplitudes. This article presents the elastic cross-section measurement and the constraints it imposes on the functional forms of the modulus and phase of the hadronic elastic amplitude. The data exclude the traditional Simplified West and Yennie interference formula that requires a constant phase and a purely exponential modulus of the hadronic amplitude. For parametrisations of the hadronic modulus with second- or third-order polynomials in the exponent, the data are compatible with hadronic phase functions giving either central or peripheral behaviour in the impact parameter picture of elastic scattering. In both cases, the ρ-parameter is found to be 0.12±0.03. The results for the total hadronic cross-section are σ tot = (102.9±2.3) mb and (103.0±2.3) mb for central and peripheral phase formulations, respectively. Both are consistent with previous TOTEM measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron-beam mapping of plasmon resonances in electromagnetically interacting gold nanorods

Electron energy-loss spectroscopy and energy-filtered transmission electron-microscope imaging are used to characterize the energy distribution of the surface plasmon of isolated and coupled gold nanorods. Local-field enhancement and spectral shift of the plasmon modes are observed for two interacting nanoparticles. The spatial modes measured by energy loss are shown to share qualitative similarities with the electromagnetic field distribution around gold nanorods induced by optical excitation as simulated using the discrete dipole-approximation method.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

XMM-NEWTON AND FUSE TENTATIVE EVIDENCE FOR A WHIM FILAMENT ALONG THE LINE OF SIGHT TO PKS 0558-504

We present a possible O VIII X-ray absorption line at z = 0.117 {+-} 0.001 which, if confirmed, will be the first one associated with a broad H I Ly{beta} (BLB: FWHM = 160{sup +50} {sub -30} km s{sup -1}) absorber. The absorber lies along the line of sight to the nearby (z = 0.1372) Seyfert 1 galaxy PKS 0558-504, consistent with being a WHIM filament. The X-ray absorber is marginally detected in two independent XMM-Newton spectra of PKS 0558-504, a long {approx}600 ks guest-observer observation and a shorter, {approx}300 ks total, calibration observation, with a combined single line statistical significance of 2.8{sigma} (2.7{sigma} and 1.2{sigma} in the two spectra, respectively). When fitted with our self-consistent hybrid-photoionization WHIM models, the combined XMM- Newton spectrum is consistent with the presence of O VIII K{alpha} at z = (0.117 {+-} 0.001). This model gives best-fitting temperature and equivalent H column density of the absorber of log T = 6.56{sup +0.19} {sub -0.17} K, and log N{sub H} = (21.5 {+-} 0.3)(Z/Z {sub 0.01sun}){sup -1} cm{sup -2}, and predicts the marginal contribution of only two more lines within the XMM- Newton Reflection Grating Spectrometer band pass, Ne IX K{alpha} ({lambda} = 13.45 A) and Fe XVII L ({lambda} = 15.02 A), both with equivalent widths well within the 1{sigma} sensitivity of the combined XMM-Newton spectrum of PKS 0558-504 (EW{sup 1}{sigma} < 3 mA). The lack of detection of associated O VI in the archival FUSE spectrum of PKS 0558-504 allows us to infer a tighter lower limit on the temperature, of log T>6.52 K (at 1{sigma}). The statistical significance of this single X-ray detection is increased by the detection of BLB and complex H I Ly{beta} absorption in archival FUSE spectra of PKS 0558-504, at redshifts z = 0.1183 {+-} 0.0001 consistent with the best-fitting redshift of the X-ray absorber. The FUSE spectrum shows a broad (FWHM = 160{sup +50} {sub -30} km s{sup -1}) absorption complex, which we identify as H I Ly{beta} z {sub BLB} = (0.1183 {+-} 0.0001). The single line statistical significance of this line is 4.1{sigma} (3.7{sigma} if systematics are considered). A possible H I Ly{alpha} is marginally hinted in an archival low-resolution ({Delta}{lambda} {approx} 6 A) International Ultraviolet Explorer (IUE) spectrum of PKS 0558-504, at a redshift of z = (0.119 {+-} 0.001) and with single line significance of 1.7{sigma}. Thus, the combined significance of the three (XMM- Newton, FUSE, and IUE) independent tentative detections, is 5.2{sigma} (5.0{sigma} if the H I Ly{alpha} is not considered, and 4.6{sigma} if the systematics in FUSE are considered). The detection of both metal and H lines at a consistent redshift, in this hot absorbing system, allows us to speculate on its metallicity. By associating the bulk of the X-ray absorber with the BLB line detected in the FUSE spectrum at z {sub BLB} = 0.1183 {+-} 0.0001, we obtain a metallicity of 1%-4% Solar. Although the absorber is only blueshifted by {approx}-6000 km s{sup -1} from the systemic redshift of PKS 0558-504, the identification of the absorbing gas with a high velocity nuclear ionized outflow, is unlikely. The physical, chemical, and dynamical properties of the detected absorber are all quite different from those typically found in the warm absorber (WA) outflows, commonly detected in Seyferts and higher luminosity quasars. WA outflow velocities typically span a range of few hundreds to {approx}1-2 thousands km s{sup -1}; WA metallicities, when measured, are typically found to be at least Solar; high-ionization WAs are virtually always found to coexist with lower-ionization X-ray and UV phases. All this strongly suggests that the absorber, if confirmed, is an intervening WHIM system.

79 ASTRONOMY AND ASTROPHYSICS↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗

Direct measurement of the positive acceleration of the universe and testing inhomogeneous models under gravitational wave cosmology

One possibility for explaining the apparent accelerating expansion of the universe is that we live in the center of a spherically inhomogeneous universe. Although current observations cannot fully distinguish ΛCDM and these inhomogeneous models, direct measurement of the acceleration of the universe can be a powerful tool in probing them. We have shown that, if ΛCDM is the correct model, DECIGO/BBO would be able to detect the positive redshift drift (which is the time evolution of the source redshift z) in 3–5 year gravitational wave (GW) observations from neutron-star binaries, which enables us to rule out any Lemaître-Tolman-Bondi (LTB) void model with monotonically increasing density profile. We may even be able to rule out any LTB model unless we allow unrealistically steep density profile at z ∼ 0. This test can be performed with GW observations alone, without any reference to electromagnetic observations, and is more powerful than the redshift drift measurement using Lyman α forest.

79 ASTRONOMY AND ASTROPHYSICS↗

First step toward a synthetic diagnostic for magnetic fluctuation measurements using cross-polarization scattering on DIII-D

Cross-polarization scattering (CPS) provides localized magnetic fluctuation ($\tilde{B}$) measurements in fusion plasmas based on the process where $\tilde{B}$ scatters electromagnetic radiation into the orthogonal polarization. The CPS system on DIII-D utilizes the probe beam of a Doppler backscattering (DBS) diagnostic combined with a cross-view CPS receiver system, which allows simultaneous density and $\tilde{B}$ measurements with good spatial and wavenumber coverage. The interpretation of the signals is challenging due to the complex plasma propagation of the DBS probe beam and CPS receive beams. A synthetic diagnostic for CPS is therefore essential to interpret data and perform detailed validation tests of non-linear turbulence simulations. This work reports a first step toward a synthetic diagnostic for CPS utilizing GENRAY, a 3-D ray tracing code, to simulate the propagation of the probe and scattered rays. The local $\tilde{B}$ wavenumber is calculated from the local O- and X-mode wavenumbers using the wave vector matching scattering condition. The CPS wavenumber values and spatial locations are determined by a complex consideration that includes the local density and $\tilde{B}$ level, receive antenna pattern and orientation, scattering volume, wavenumber values detected at the various scattering centers, and alignment of the magnetic wave vector with the plane perpendicular to the magnetic field. The issue of a spurious CPS signal due to polarization mismatches for launch and receive is also discussed. It is suggested that simultaneous O- and X-mode DBS measurements should be utilized for better understanding of the CPS signal contamination when the cutoff locations for both polarizations are close.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation into the semimagic nature of the tin isotopes through electromagnetic moments

A complete set of electromagnetic moments, B(E2;0 + 1 2 + 1 ), Q(2 + 1 ), and g(2 + 1 ), have been measured from Coulomb excitation of semi-magic 112,114,116,118,120,122,124 Sn (Z = 50) on natural carbon and titanium targets. The magnitude of the B(E2) values, measured to a precision of ~4%, disagree with a recent lifetime study [Phys. Lett. B 695, 110 (2011)] that employed the Doppler- shift attenuation method. The B(E2) values show an overall enhancement compared with recent theoretical calculations and a clear asymmetry about midshell, contrary to naive expectations. A new static electric quadrupole moment, Q(2 + 1 ), has been measured for 114 Sn. The static quadrupole moments are generally consistent with zero but reveal an enhancement near midshell; this had not been previously observed. The magnetic dipole moments are consistent with previous measurements and show a near monotonic decrease in value with neutron number. The current theory calculations fail to reproduce the electromagnetic moments of the tin isotopes. The role of 2p-2h and 4p-4h intruders, which are lowest in energy at mid shell and outside of current model spaces, needs to be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electromagnetic power of lightning superbolts from Earth to space

Lightning superbolts are the most powerful and rare lightning events with intense optical emission, first identified from space. Superbolt events occurred in 2010-2018 could be localized by extracting the high energy tail of the lightning stroke signals measured by the very low frequency ground stations of the World-Wide Lightning Location Network. Here, we report electromagnetic observations of superbolts from space using Van Allen Probes satellite measurements, and ground measurements, and with two events measured both from ground and space. From burst-triggered measurements, we compute electric and magnetic power spectral density for very low frequency waves driven by superbolts, both on Earth and transmitted into space, demonstrating that superbolts transmit 10-1000 times more powerful very low frequency waves into space than typical strokes and revealing that their extreme nature is observed in space. We find several properties of superbolts that notably differ from most lightning flashes; a more symmetric first ground-wave peak due to a longer rise time, larger peak current, weaker decay of electromagnetic power density in space with distance, and a power mostly confined in the very low frequency range. Their signal is absent in space during day times and is received with a long-time delay on the Van Allen Probes. These results have implications for our understanding of lightning and superbolts, for ionosphere-magnetosphere wave transmission, wave propagation in space, and remote sensing of extreme events.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron Bunch Profile Reconstruction in the Few fs Regime using Coherent Smith-Purcell Radiation

Advanced accelerators for fourth generation light sources based on high brightness linacs or laser-driven wakefield accelerators will operate with intense, highly relativistic electron bunches that are only a few fs long. Diagnostic techniques for the determination of temporal profile of such bunches are required to be non invasive, single shot, economic and with the required resolution in the fs regime. The use of a radiative process such as coherent Smith-Purcell radiation (SPR), is particularly promising with this respect. In this technique the beam is made to radiate a small amount of electromagnetic radiation and the temporal profile is reconstructed from the measured spectral distribution of the radiation. We summarise the advantages of SPR and present the design parameters and preliminary results of the experiments at the FACET facility at SLAC. We also discuss a new approach to the problem of the recovery of the 'missing phase', which is essential for the accurate reconstruction of the temporal bunch profile.

43 PARTICLE ACCELERATORS↗