Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Prostate-Specific Antigen at 4 to 5 Years After Low-Dose-Rate Prostate Brachytherapy Is a Strong Predictor of Disease-Free Survival

Purpose: To determine (1) the prognostic utility of prostate-specific antigen (PSA) concentration at 45 to 60 months (48mPSA) after low-dose-rate prostate brachytherapy (LDR-PB); (2) the predictors of 48mPSA; and (3) the prognostic utility of directional trends between PSA levels at 24, 36, and 48 months after LDR-PB. Methods and Materials: Between 1998 and 2008, 2223 patients with low- and intermediate-risk prostate cancer received LDR-PB monotherapy. A cohort of 1434 of these patients was identified with a documented 48mPSA and no evidence of disease relapse prior to the 48mPSA. In addition, a subset of this cohort (n=585) was identified with ≥72 months of follow-up and documented PSA values at both 24 and 36 months after implantation. Results: Median follow-up time was 76 months. Eight-year Kaplan-Meier disease-free survival (DFS) rates were 100% vs 73.4% for patients with 48mPSA ≤0.2 vs those with >0.2 ng/mL; 99.1% versus 53.8% for a 48mPSA threshold of ≤0.4 versus >0.4 ng/mL, respectively; and 97.3% versus 0% for a threshold of ≤1.0 versus >1.0 ng/mL, respectively. On multivariate analysis, the only factor predictive of DFS was 48mPSA (P<.0001). On subset analysis (n=585), 29 patients had a PSA rise (defined as >0.2 ng/mL) between 24 and 36 months, 24 patients had a rise between 36 and 48 months, and 11 patients had rises over both intervals. Failure rates in these patients were 52%, 79%, and 100%, respectively. On multivariate analysis, initial PSA, androgen deprivation therapy, and dose to 90% of the prostate significantly correlated with 48mPSA but together accounted for only ∼5% of its total variance. Conclusions: The 48mPSA after LDR-PB is highly predictive of long-term DFS. Patients with 48mPSA ≤0.4 ng/mL had a <1% risk of disease relapse at 8 years, whereas all patients with 48mPSA >1.0 ng/mL relapsed. Consecutive PSA rises of >0.2 ng/mL from 24 to 36 months and from 36 to 48 months were also highly predictive of subsequent failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors

Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo). Methods: We analyzed 17 patients; EPID images of the exit dose were acquired and used to reconstruct the planar dose at isocenter. This dose was compared to the TPS dose using a 3%/3mm gamma criteria. To simulate errors, modifications were made to treatment plans using four possible classes of error: 1) patient misalignment, 2) changes in patient body habitus, 3) machine output changes and 4) MLC misalignments. Each error was applied with varying magnitudes. To assess the detectability of the error, the area under a ROC curve (AUC) was analyzed. The AUC was compared to changes in D99 of the PTV introduced by the simulated error. Results: For systematic changes in the MLC leaves, changes in the machine output and patient habitus, the AUC varied from 0.78–0.97 scaling with the magnitude of the error. The optimal gamma threshold as determined by the ROC curve varied between 84–92%. There was little diagnostic power in detecting random MLC leaf errors and patient shifts (AUC 0.52–0.74). Some errors with weak detectability had large changes in D99. Conclusion: These data demonstrate the ability of EPID-based in-vivo dosimetry in detecting variations in patient habitus and errors related to machine parameters such as systematic MLC misalignments and machine output changes. There was no correlation found between the detectability of the error using the gamma pass rate, ROC analysis and the impact on the dose volume histogram. Funded by grant R18HS022244 from AHRQ.

60 APPLIED LIFE SCIENCES↗

The LINAC Coherent Light Source and Radiological Issues During the Commissioning

The Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory is the world's first X-ray free electron laser (XFEL). Pulses of x-ray laser light from LCLS will be many orders of magnitude brighter and several orders of magnitude shorter than what can be produced by other x-ray sources available in the world. These characteristics will enable frontier new science in many areas. This paper describes the LCLS beam parameters and lay-out. The general radiological issues during commissioning are presented, such as radiation dose rates and integrated doses outside the enclosure. Also, specific radiological issues related to X-ray free electron lasers are discussed. XFEL with high peak power will burn through high-Z materials. The X-ray beam needs to be blocked by stoppers when the downstream areas are occupied. LCLS stoppers feature a piece of boron carbide (B{sub 4}C), 10 mm thick. B{sub 4}C is one of the best materials since it has a low absorption coefficient for X-rays and a high melting temperature. Theoretical calculations indicate that the unfocused fluence of the LCLS XFEL beam should be about one order of magnitude below the damage threshold for bulk B{sub 4}C, for 830 eV FEL radiation. However, these calculations have not been tested experimentally and cannot be validated until LCLS begins providing 830 eV XFEL pulses. This paper describes the test plan for using the initial LCLS radiation to evaluate the survivability of B{sub 4}C and reports the preliminary results. Another major issue for LCLS is the potential radiation damage to the LCLS undulator magnets during operation. TLD dosimeters were installed along the LCLS undulators for each period of two or three weeks. This paper reports the integrated doses along the undulators with and without XFEL generation.

SAFETY, XFEL↗

Characterization and Monte Carlo Simulations of a 4-Liter NaI Detection System for Use During Nuclear and Radiological Emergencies and for the Detection of Nuclear Materials

SCKCEN is engaged in research related to the use of a large volume NaI detection system for use during nuclear and radiological emergencies and for the detection of nuclear materials. As part of this effort a research activity is being carried out to determine the characteristics and build a Monte Carlo model of the available 4-liter NaI detector. These activities consist of (i) determination of energy resolution efficiency lower threshold background in laboratory conditions using well-characterized point sources; (ii) modeling of the detector by Monte Carlo methods and validation; (iii) determination of the response function by combining measurement and simulation results; (iv) characterization of the detector for contaminated surfaces by measurements and modeling; and (v) calibration of detector for dose rate measurements. This paper will focus on the results obtained so far concerning the Monte Carlo model and its validation with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The image quality of ion computed tomography at clinical imaging dose levels

Purpose: Accurately predicting the range of radiotherapy ions in vivo is important for the precise delivery of dose in particle therapy. Range uncertainty is currently the single largest contribution to the dose margins used in planning and leads to a higher dose to normal tissue. The use of ion CT has been proposed as a method to improve the range uncertainty and thereby reduce dose to normal tissue of the patient. A wide variety of ions have been proposed and studied for this purpose, but no studies evaluate the image quality obtained with different ions in a consistent manner. However, imaging doses ion CT is a concern which may limit the obtainable image quality. In addition, the imaging doses reported have not been directly comparable with x-ray CT doses due to the different biological impacts of ion radiation. The purpose of this work is to develop a robust methodology for comparing the image quality of ion CT with respect to particle therapy, taking into account different reconstruction methods and ion species. Methods: A comparison of different ions and energies was made. Ion CT projections were simulated for five different scenarios: Protons at 230 and 330 MeV, helium ions at 230 MeV/u, and carbon ions at 430 MeV/u. Maps of the water equivalent stopping power were reconstructed using a weighted least squares method. The dose was evaluated via a quality factor weighted CT dose index called the CT dose equivalent index (CTDEI). Spatial resolution was measured by the modulation transfer function. This was done by a noise-robust fit to the edge spread function. Second, the image quality as a function of the number of scanning angles was evaluated for protons at 230 MeV. In the resolution study, the CTDEI was fixed to 10 mSv, similar to a typical x-ray CT scan. Finally, scans at a range of CTDEI’s were done, to evaluate dose influence on reconstruction error. Results: All ions yielded accurate stopping power estimates, none of which were statistically different from the ground truth image. Resolution (as defined by the modulation transfer function = 10% point) was the best for the helium ions (18.21 line pairs/cm) and worst for the lower energy protons (9.37 line pairs/cm). The weighted quality factor for the different ions ranged from 1.23 for helium to 2.35 for carbon ions. For the angle study, a sharp increase in absolute error was observed below 45 distinct angles, giving the impression of a threshold, rather than smooth, limit to the number of angles. Conclusions: The method presented for comparing various ion CT modalities is feasible for practical use. While all studied ions would improve upon x-ray CT for particle range estimation, helium appears to give the best results and deserves further study for imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantry-angle resolved VMAT pretreatment verification using EPID image prediction

Purpose: Pretreatment verification of volumetric modulated arc therapy (VMAT) dose delivery with electronic portal imaging device (EPID) uses images integrated over the entire delivery or over large subarcs. This work aims to develop a new method for gantry-angle-resolved verification of VMAT dose delivery using EPID.Methods: An EPID dose prediction model was used to calculate EPID images as a function of gantry angle for eight prostate patient deliveries. EPID image frames at 7.5 frames per second were acquired during delivery via a frame-grabber system. The gantry angle for each image was encoded in kV frames which were synchronized to the MV frames. Gamma analysis results as a function of gantry angle were assessed by integrating the frames over 2° subarcs with an angle-to-agreement tolerance of 0.5° about the measured image angle.Results: The model agreed with EPID images integrated over the entire delivery with average Gamma pass-rates at 2%, 2 mm of 99.7% (10% threshold). The accuracy of the kV derived gantry angle for each image was found to be 0.1° (1 SD) using a phantom test. For the gantry-resolved analysis all Gamma pass-rates were greater than 90% at 3%, 3 mm criteria (with only two exceptions), and more than 90% had a 95% pass-rate, with an average of 97.3%. The measured gantry angle lagged behind the predicted angle by a mean of 0.3°± 0.3°, with a maximum lag of 1.3°.Conclusions: The method provides a comprehensive and highly efficient pretreatment verification of VMAT delivery using EPID. Dose delivery accuracy is assessed as a function of gantry angle to ensure accurate treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrating Mercury Concentrations in American Alligators ( Alligator mississippiensis ) with Hunter Consumption Surveys to Estimate Exposure Risk

Mercury is a naturally occurring element but is also considered a widespread contaminant due to global anthropogenic activity. Even in moderate amounts, mercury (Hg) is an established neurotoxin and is associated with a range of adverse outcomes both in humans and wildlife. Humans in the United States are most commonly exposed to Hg through contaminated food or drinking water, and the consumption of game species, particularly those occupying higher trophic levels, has the potential to expose hunters to high concentrations of Hg. In the present study, we determined Hg concentrations in tail muscle and blood from American alligators (Alligator mississippiensis) inhabiting a region (Savannah River Site, SC, USA) with known Hg contamination. We then integrated these data with alligator harvest records and previously published surveys of alligator meat consumption patterns to estimate potential exposure risk. We found that the average Hg concentrations in tail muscle (1.34 mg/kg, wet wt) from sampled alligators exceeded the recommended threshold for Hg exposure based on the World Health Organization's guidelines (0.5mg/kg, wet wt). In addition, based on regional consumption patterns reported for both adults and children, we estimated Hg exposures (x¯ Adult = 0.419 μg/kg/day, x¯ Child = 2.24 μg/kg/day) occurring well above the US Environmental Protection Agency methylmercury reference dose of 0.1 μg/kg/day. Although the two reservoirs sampled in the present study are not currently open to alligator hunting, they are connected to waters that are publicly accessible, and the extent of alligator mobility across these sites is not known. Together, the findings reported in the present study further demonstrate the need for active monitoring of Hg concentrations in game species, which can convey substantial exposure risks to the public.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developmental neurotoxic effects of two pesticides: Behavior and biomolecular studies on chlorpyrifos and carbaryl

In recent times, an increased occurrence of neurodevelopmental disorders, such as neurodevelopmental delays and cognitive abnormalities has been recognized. Exposure to pesticides has been suspected to be a possible cause of these disorders, as these compounds target the nervous system of pests. Due to the similarities of brain development and composition, these pesticides may also be neurotoxic to humans. We studied two different pesticides, chlorpyrifos and carbaryl, which specifically inhibit acetylcholinesterase (AChE) in the nervous system. The aim of the study was to investigate if the pesticides can induce neurotoxic effects, when exposure occurs during a period of rapid brain growth and maturation. The results from the present study show that both compounds can affect protein levels in the developing brain and induce persistent adult behavior and cognitive impairments, in mice neonatally exposed to a single oral dose of chlorpyrifos (0.1, 1.0 or 5 mg/kg body weight) or carbaryl (0.5, 5.0 or 20.0 mg/kg body weight) on postnatal day 10. The results also indicate that the developmental neurotoxic effects induced are not related to the classical mechanism of acute cholinergic hyperstimulation, as the AChE inhibition level (8–12%) remained below the threshold for causing systemic toxicity. The neurotoxic effects are more likely caused by a disturbed neurodevelopment, as similar behavioral neurotoxic effects have been reported in studies with pesticides such as organochlorines, organophosphates, pyrethroids and POPs, when exposed during a critical window of neonatal brain development. - Highlights: • A single neonatal exposure to chlorpyrifos or carbaryl induced developmental neurotoxic effects. • The neurotoxic effects were not caused by acute AChE inhibition. • The neurotoxic effects manifested as altered levels of neuroproteins in the developing brain. • The neurotoxic effects manifested as adult persistent aberrant behavior and cognitive function. • The neurotoxic effects are suggested to be caused by disrupted brain development.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-02: Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Stage I and II Peripheral Lung Tumors with Unflattened Beams

Purpose: The full arcs strategy used in SBRT with RapidArc and unflattened (FFF) beams in large and heterogeneous peripheral non-smallcell lung cancer (NSCLC) appears to be suboptimal as it increases the disadvantageous dose to the contralateral lung, which potentially increases the toxicity to surrounding tissues. In this study, we investigated, for the first time, the dose delivery strategies using partial arcs (PA) and the fully rotational arcs with avoidance sectors (FAAS) for SBRT with FFF beams in peripheral NSCLC patients. Methods: Eighteen patients with NSCLC (stage I and II) were selected for this study. Nine patients with a GTV <= 10cc were designated as the small tumor group. The remaining nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OAR), total MU, out-of-field dose, and delivery time were analyzed. Delta4 and Portal dosimetry were employed to evaluate the delivery accuracy. Results: or the small tumor group, the FAAS plans significantly achieved a better conformity index, the lower total MU and out-of-field dose, a shorter treatment time, and the reduced doses to cord, heart, and lung (p < 0.05). But the target doses were slightly higher than that delivered by PA plans. For the large tumor group, the PA plans significantly attained a better conformity index and a shorter treatment time (p < 0.05). Furthermore, all plans achieved a high pass rate, with all the gamma indices greater than 97% at the Γ{sub 3mm,} {sub 3%} threshold. Conclusion: This study suggests that FAAS strategy is more beneficial for small tumor patients undergoing lung SBRT with FFF beams. However, for large tumor patients, PA strategy is recommended. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-02: 3D Remote Dosimetry for MRI-Guided Radiation Therapy: A Hybrid Approach

Purpose: To validate the dosimetric accuracy of a commercially available MR-IGRT system using a combination of 3D dosimetry measurements (with PRESAGE(R) radiochromic plastic and optical-CT readout) and an in-house developed GPU-accelerated PENELOPE Monte-Carlo dose calculation system. Methods: {sup 60}Co IMRT subject to a 0.35T lateral magnetic field has recently been commissioned in our institution following AAPM’s TG-119 recommendations. We performed PRESAGE(R) sensitivity studies in 4ml cuvettes to verify linearity, MR-compatibility, and energy-independence. Using 10cm diameter PRESAGE(R), we delivered an open calibration field to examine the percent depth dose and a symmetrical 3-field plan with three adjacent regions of varying dose to determine uniformity within the dosimeter under a magnetic field. After initial testing, TG-119 plans were created in the TPS and then delivered to 14.5cm 2kg PRESAGE(R) dosimeters. Dose readout was performed via optical-CT at a second institution specializing in remote 3D dosimetry. Absolute dose was measured using an IBA CC01 ion chamber and the institution standard patient-specific QA methods were used to validate plan delivery. Calculated TG-119 plans were then compared with an independent Monte Carlo dose calculation (gPENELOPE). Results: PRESAGE(R) responds linearly (R{sup 2}=0.9996) to {sup 60}Co irradiation, in the presence of a 0.35T magnetic field, with a sensitivity of 0.0305(±0.003)cm{sup −1}Gy{sup −1}, within 1% of a 6MV non-MR linac irradiation (R{sup 2}=0.9991) with a sensitivity of 0.0302(±0.003)cm{sup −1}Gy{sup −1}. Analysis of TG-119 clinical plans using 3D-gamma (3%/3mm, 10% threshold) give passing rates of: HN 99.1%, prostate 98.0%, C-shape 90.8%, and multi-target 98.5%. The TPS agreed with gPENELOPE with a mean gamma passing rate of 98.4±1.5% (2%/2mm) with the z-score distributions following a standard normal distribution. Conclusion: We demonstrate for the first time that 3D remote dosimetry using both experimental and computational methods is a feasible and reliable approach to commissioning MR-IMRT, which is particularly useful for less specialized clinics in adopting this new treatment modality.

60 APPLIED LIFE SCIENCES↗

Automated aortic calcium scoring on low-dose chest computed tomography

Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm{sup 3} out of 965 mm{sup 3} (97.9%) calcified plaque volume in the aorta with an average of 64 mm{sup 3} of false positive volume per scan. Spearman rank correlation coefficient was {rho}=0.960 between the system and the first observer compared to {rho}=0.961 between the two observers. Conclusions: Automatic calcium scoring in the aorta thus appears feasible with good correlation between manual and automatic scoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consistency of vendor-specified activity values for {sup 192}Ir brachytherapy sources

A long-term comparison was done between the manufacturer-stated {sup 192}Ir activity and the measured {sup 192}Ir activities determined with a well-type ionization chamber. Sources for a Nucletron Micro Selectron high-dose-rate (HDR) unit were used for this purpose. The radioactive sources reference activities were determined using a PTW well-type ionization chamber traceable to the National Institute of Standards and Technology Primary Calibration Laboratory. The measurements were taken in a period of 56 months with 17 different radioactive sources. The manufacturer stated activities were taken from the source calibration certificate provided by the manufacturer. These values were compared with the measured activities. The results have shown that both the percentage deviation of the monthly control measurements with the well-type chamber and the ratio between the measured activities to the manufacturer-stated value lie within {+-} 2.5%. These results were compared with similar published data and with uncertainty level (3% of the mean and 5% maximum deviation from mean) for brachytherapy sources calibration recommended by the AAPM. It was concluded that a threshold level of {+-}2.5% can be used as a suitable quality assurance indicator to spot problems in our department. The typical {+-}5% uncertainty as provided by the manufacturers may be tightened to {+-}3% to be more in line with published AAPM reports.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRA-16: Development of a Radiation Monitoring Device Using a Low-Cost CCD Camera Following Radionuclide Therapy

Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Apple iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.

60 APPLIED LIFE SCIENCES↗

Recent Improvements To CINDER2008 and Activation Analysis Tools

CINDER2008 is a transmutation code that calculates induced radioactivity for either reactor- or accelerator-driven radiation sources. Several Perl scripts have been developed to treat multi-cell problems in combination with either the radiation transport code MCNPX or a special version of MCNPX that writes residual nuclide tallies from model-based physics directly in the MCNPX output file. These scripts simplify the preparation of CINDER input, and can use CINDER output to prepare the source term for a subsequent MCNPX run to calculate dose rates due to activated material. In addition, these scripts support calculations with the transmutation codes SP-FISPACT and ORIHET-3. A number of improvements have been made to CINDER, its data libraries, and the Perl scripts, including (1) substantial corrections to the data libraries, (2) inclusion of recent revisions to USDOE HC-2/HC-3 thresholds and the corresponding thresholds for regulatory bodies in other countries, (3) the ability to run the CINDER accident analysis tool through the script input file, and (4) an easier way to write the script input file when treating a large number of cells. Some features of running CINDER and a number of example problems are discussed.

Micklich, Bradley J.↗

Aloperine attenuated neuropathic pain induced by chronic constriction injury via anti-oxidation activity and suppression of the nuclear factor kappa B pathway

Highlights: • Aloperine has anti-nociceptive effects on neuropathic pain induced CCI. • Aloperine reduces ROS in neuropathic pain mice. • Aloperine down-regulates the expression of NF-κB and its downstream pro-inflammatory cytokines in neuropathic pain mice. - Abstract: Objective: To investigate whether aloperine (ALO) has antinociceptive effects on neuropathic pain induced by chronic constriction injury, whether ALO reduces ROS against neuropathic pain, and what are the mechanisms involved in ALO attenuated neuropathic pain. Methods: Mechanical and cold allodynia, thermal and mechanical hyperalgesia and spinal thermal hyperalgesia were estimated by behavior methods such as Von Frey filaments, cold-plate, radiant heat, paw pressure and tail immersion on one day before surgery and days 7, 8, 10, 12 and 14 after surgery, respectively. In addition, T-AOC, GSH-PX, T-AOC and MDA in the spinal cord (L4/5) were measured to evaluate anti-oxidation activity of ALO on neuropathic pain. Expressions of NF-κB and pro-inflammatory cytokines (TNF-α, IL-6, IL-1β) in the spinal cord (L4/5) were analyzed by using Western blot. Results: Administration of ALO (80 mg/kg and 40 mg/kg, i.p.) significantly increased paw withdrawal threshold, paw pressure, paw withdrawal latencies, tail-curling latencies, T-AOC, GSH-PX and T-SOD concentration, reduced the numbers of paw lifts and MDA concentration compared to CCI group. ALO attenuated CCI induced up-regulation of expressions of NF-κB, TNF-α, IL-6, IL-1β at the dose of 80 mg/kg (i.p.). Pregabalin produced similar effects serving as positive control at the dose of 10 mg/kg (i.p.). Conclusion: ALO has antinociceptive effects on neuropathic pain induced by CCI. The antinociceptive effects of ALO against neuropathic pain is related to reduction of ROS, via suppression of NF-κB pathway.

60 APPLIED LIFE SCIENCES↗

Effect of reconstruction methods and x-ray tube current–time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study

Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR{sup 3D}) and filtered back projection (FBP) over a range of tube current–time product (mAs). Methods: Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, 10, and 12 mm in diameter and +100, −630, and −800 Hounsfield units electron density; this would generate CT images for the observer study; (ii) a whole-body dosimetry verification phantom was used to ultimately estimate effective dose and risk according to the model of the BEIR VII committee. Both phantoms were scanned over a mAs range (10, 20, 30, and 40), while all other acquisition parameters remained constant. Images were reconstructed with both AIDR{sup 3D} and FBP. For the observer study, 34 normal cases (no nodules) and 34 abnormal cases (containing 1–3 nodules, mean 1.35 ± 0.54) were chosen. Eleven observers evaluated images from all mAs and reconstruction methods under the free-response paradigm. A crossed-modality jackknife alternative free-response operating characteristic (JAFROC) analysis method was developed for data analysis, averaging data over the two factors influencing nodule detection in this study: mAs and image reconstruction (AIDR{sup 3D} or FBP). A Bonferroni correction was applied and the threshold for declaring significance was set at 0.025 to maintain the overall probability of Type I error at α = 0.05. Contrast-to-noise (CNR) was also measured for all nodules and evaluated by a linear least squares analysis. Results: For random-reader fixed-case crossed-modality JAFROC analysis, there was no significant difference in nodule detection between AIDR{sup 3D} and FBP when data were averaged over mAs [F(1, 10) = 0.08, p = 0.789]. However, when data were averaged over reconstruction methods, a significant difference was seen between multiple pairs of mAs settings [F(3, 30) = 15.96, p < 0.001]. Measurements of effective dose and effective risk showed the expected linear dependence on mAs. Nodule CNR was statistically higher for simulated nodules on images reconstructed with AIDR{sup 3D} (p < 0.001). Conclusions: No significant difference in nodule detection performance was demonstrated between images reconstructed with FBP and AIDR{sup 3D}. mAs was found to influence nodule detection, though further work is required for dose optimization.

60 APPLIED LIFE SCIENCES↗

A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom

In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three “boxes” are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This “in-house build” phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of electrical field on the susceptibility of gallium nitride transistors to proton irradiation

Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 10 12 to 3.76 × 10 14 cm 2 , and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According to in-situ Raman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability.

gallium nitride↗