Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution Islanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Metal Halide Perovskites in Quantum Dot Solar Cells: Progress and Prospects

“Go big or go home” could never be a truer statement, especially when it comes to energy. The world population is increasing, the energy use per person is growing more rapidly, and the total electricity use per person is growing even more quickly than that. To handle this demand, energy production must be increased, and it is vital for renewable sources to be used. Currently three quarters of a terawatt of power generated from photovoltaics (PVs) has been installed. At a somewhat optimistic average power-conversion efficiency of 18%, the distributed surface area of high purity optoelectronic grade semiconductor photovoltaic panels pointed at the sun is substantially larger than the area of the whole state of Rhode Island or nearly double the land mass of Luxembourg. While photovoltaic production continues to ramp to immense proportions, perovskite semiconductors are poised to greatly complement existing technology. On the other end of the size spectrum, the study of semiconductor nanocrystals or quantum dots (QDs) has led to advanced structures and deeper understanding within halide perovskite semiconductors. In this article, we show how the development of nanoscale metal halide perovskite semiconductors have gained prominence surpassing all other QD materials in terms of efficiency, and are becoming a platform for further improving technology to solve big energy challenges.

14 SOLAR ENERGY↗

Ramping Performance Analysis of the Kahuku Wind-Energy Battery Storage System

High penetrations of wind power on the electrical grid can introduce technical challenges caused by resource variability. Such variability can have undesirable effects on the frequency, voltage, and transient stability of the grid. Energy storage devices can be an effective tool in reducing variability impacts on the power grid in the form of power smoothing and ramp control. Integrating anenergy storage system with a wind power plant can help smooth the variable power produced from wind. This paper explores the fast-response, megawatt-scale, wind-energy battery storage systems that were recently deployed throughout the Hawaiian islands to support wind and solar projects.

17 WIND ENERGY↗

Reactive iron in marine sediments

The influence of reactive iron oxides on sediment pore-water chemistry is considered in detail. A carefully calibrated extraction scheme is used to determine the depth distributions of reactive iron phases at two very different localities: the relatively iron-rich Mississippi Delta and the relatively iron-poor FOAM site in Long Island Sound. Closed system incubations are used to characterize the rates of reaction between sulfide and both naturally occurring and pure iron mineral phases. Rates of iron liberation to pore solution are measured in the presence and absence of sulfate reduction, and the origin of dissolved iron in organic-rich sediments is speculated upon.

Canfield, Donald E.↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

U.S. Virgin Islands Wind Resources Update 2014

This report summarized the data collected from two 60-meter (m) meteorological towers (met masts or met towers) and three sonic detection and ranging (SODAR) units on St. Thomas and St. Croix in 2012 and 2013. These results are an update to the previous feasibility study; the collected data are critical to the successful development of a wind project at either site (Lantz et al. 2012). The wind maps for the territory were updated based on these improved data. The National Renewable Energy Laboratory (NREL) conducted measurements from met towers and SODAR units for several locations in the U.S. Virgin Islands (USVI). Both met masts were deployed for more than a year and produced high-quality data (standard industry practice in the wind industry). The Longford (St. Croix) and Bovoni (St. Thomas) sites are estimated to have long-term corrected wind speeds that exceed 7 meters per second (m/s), which may produce financially viable wind projects for both sites. The levelized cost of energy for both sites was estimated at $\$$0.08–$\$$0.14 per kilowatt-hour for typical utility-scale wind turbine with the uncertainty in the estimate driven by uncertainty in the installed capital costs of the proposed wind farms. These estimates assume that the wind production tax credit is not reinstated, but that accelerated depreciation is in place.

17 WIND ENERGY↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Degradation mechanisms of Ti/Al/Ni/Au-based Ohmic contacts on AlGaN/GaN HEMTs

We investigated the degradation mechanism of Ti/Al/Ni/Au-based Ohmic metallization on AlGaN/GaN high electron mobility transistors upon exposure to buffer oxide etchant (BOE). The major effect of BOE on the Ohmic metal was an increase of sheet resistance from 2.89 to 3.69 Ω/ₜafter 3 min BOE treatment. The alloyed Ohmic metallization consisted 3–5 μm Ni-Al alloy islands surrounded by Au-Al alloy-rings. The morphology of both the islands and ring areas became flatter after BOE etching. Lastly, we used energy dispersive x-ray analysis and Auger electron microscopy to analyze the compositions and metal distributions in the metal alloys prior to and after BOE exposure.

36 MATERIALS SCIENCE↗

Simulation of Distributed PV Power Output in Oahu Hawaii

Distributed solar photovoltaic (PV) power generation in Oahu has grown rapidly since 2008. For applications such as determining the value of energy storage, it is important to have PV power output timeseries. Since these timeseries of not typically measured, here we produce simulated distributed PV power output for Oahu. Simulated power output is based on (a) satellite-derived solar irradiance, (b) PV permit data by neighborhood, and (c) population data by census block. Permit and population data was used to model locations of distributed PV, and irradiance data was then used to simulate power output. PV power output simulations are presented by sub-neighborhood polygons, neighborhoods, and for the whole island of Oahu. Summary plots of annual PV energy and a sample week timeseries of power output are shown, and a the files containing the entire timeseries are described.

14 SOLAR ENERGY↗

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis

This report presents an analytical methodology to identify alternative options to manage interconnection costs and streamline interconnection timelines for distribution system-connected photovoltaic (PV) systems not co-located with load. Specifically, the report details the methodology and results of an analysis that: 1. Identifies potential grid violations that would be induced by a PV system requesting interconnection to a distribution circuit; 2. Identifies multiple technically viable options for mitigating the potential violations, including infrastructure upgrades, downsizing the PV system size, curtailment of PV, and addition of battery energy storage; 3. Defines the required technical operating parameters of the system in order to mitigate all potential violations (the "Operating Envelope"); 4. Compares the economics of each option, from the PV developer's perspective. The analysis supports the ongoing evolution of interconnection standards for combined PV and energy storage systems by providing a methodology to define allowable maximum export limits during each hour. The methodology presented could be used by utilities as part of the interconnection study process, to inform negotiations with DER developers and the drafting of mutually acceptable interconnection agreements. The resulting technical operating parameters could be included as part of the interconnection service agreement (ISA) between the system owner and the utility company. The companion report to this analysis, Gill et al. (2022), details the envisioned framework for the implementation of the technical operating parameters.

14 SOLAR ENERGY↗

Quantification of hydraulic trait control on plant hydrodynamics and risk of hydraulic failure within a demographic structured vegetation model in a tropical forest (FATES–HYDRO V1.0)

Abstract. Vegetation plays a key role in the global carbon cycle and thus is an important component within Earth system models (ESMs) that project future climate. Many ESMs are adopting methods to resolve plant size and ecosystem disturbance history, using vegetation demographic models. These models make it feasible to conduct more realistic simulation of processes that control vegetation dynamics. Meanwhile, increasing understanding of the processes governing plant water use, and ecosystem responses to drought in particular, has led to the adoption of dynamic plant water transport (i.e., hydrodynamic) schemes within ESMs. However, the extent to which variations in plant hydraulic traits affect both plant water stress and the risk of mortality in trait-diverse tropical forests is understudied. In this study, we report on a sensitivity analysis of an existing hydrodynamic scheme (HYDRO) model that is updated and incorporated into the Functionally Assembled Terrestrial Ecosystem Simulator (FATES) (FATES–HYDRO V1.0). The size- and canopy-structured representation within FATES is able to simulate how plant size and hydraulic traits affect vegetation dynamics and carbon–water fluxes. To better understand this new model system, and its functionality in tropical forest systems in particular, we conducted a global parameter sensitivity analysis at Barro Colorado Island, Panama. We assembled 942 observations of plant hydraulic traits on 306 tropical plant species for stomata, leaves, stems, and roots and determined the best-fit statistical distribution for each trait, which was used in model parameter sampling to assess the parametric sensitivity. We showed that, for simulated leaf water potential and loss of hydraulic conductivity across different plant organs, the four most important traits were associated with xylem conduit taper (buffers increasing hydraulic resistance with tree height), stomatal sensitivity to leaf water potential, maximum stem hydraulic conductivity, and the partitioning of total hydraulic resistance above vs. belowground. Our analysis of individual ensemble members revealed that trees at a high risk of hydraulic failure and potential tree mortality generally have a lower conduit taper, lower maximum xylem conductivity, lower stomatal sensitivity to leaf water potential, and lower resistance to xylem embolism for stem and transporting roots. We expect that our results will provide guidance on future modeling studies using plant hydrodynamic models to predict the forest responses to droughts and future field campaigns that aim to better parameterize plant hydrodynamic models.

54 ENVIRONMENTAL SCIENCES↗

Satellite geological and geophysical remote sensing of Iceland

The author has identified the following significant results. A low sun angle (as low as 7 degrees) on ERTS-1 imagery, particularly when the terrain is snow-covered, markedly enhances subtle geologic structure and landforms. Hot springs, discharging into frozen lakes, from an ice-free area which can be easily seen on ERTS-1 imagery. In remote areas ERTS-1 imagery can be used in climatological studies by using the time of lake ice freeze-up and break-up as a measure over large areas. ERTS-1 imagery of the erupting volcano, Kirkjufell, on the island of Heimaey was cloud covered. ERTS-1 provides a powerful new tool for volcanologists to study erupting volcanoes, new deposits of lava, and the direction and areal distribution of the eruption plume. Some success was achieved in a preliminary study, using photogrammetric instrumentation, of measuring relative elevation of mountains using ERTS-1 imagery of iceland, where considerable overlap exists in successive orbits.

Williams, R. S., Jr.↗

Ion Velocity Distributions Within LLBL and Their Possible Implication to Multiple Reconnections

We analyze two LLBL crossings made by Interball Tail satellite under southward or variable magnetosheath magnetic field: one crossing on the flank of the magnetosphere, and another one closer to the subsolar point. Three different types of ion velocity distributions within LLBL are observed: (a) D-shaped distributions, (b) ion velocity distributions consisting of two counter-streaming components of magnetosheath-ty and (c) distributions with three components one of which has nearly zero parallel velocity and two counter-streaming components. Only the (a) type fits to the single magnetic flux tube formed by reconnection between magnetospheric and magnetosheath magnetic fields. We argue that two counter-streaming magnetosheath-like ion components observed by Interball within LLBL cannot be explained by the reflection of the ions from the magnetic mirror deeper within magnetosphere. Types (b) and (c) ion velocity distributions would form within spiral magnetic flux tube consisting of a mixture of alternating segments originating from the magnetosheath and from magnetospheric plasma. The shapes of ion velocity distributions and their evolution with decreasing number density in LLBL indicate that a significant part of LLBL is located on magnetic field lines of long spiral flux tube islands at the magnetopause, as has been proposed and found to occur in magnetopause simulations. We consider these observations as evidence for multiple reconnection X-ray lines between magnetosheath and magnetospheric flux tubes.

Vaisberg, O. L.↗

Classifier-Guided Sampling for Complex Energy System Optimization

This report documents the results of a Laboratory Directed Research and Development (LDRD) effort entitled “Classifier-Guided Sampling for Complex Energy System Optimization” that was conducted during FY 2014 and FY 2015. The goal of this project was to develop, implement, and test major improvements to the classifier-guided sampling (CGS) algorithm. CGS is type of evolutionary algorithm for performing search and optimization over a set of discrete design variables in the face of one or more objective functions. Existing evolutionary algorithms, such as genetic algorithms, may require a large number of objective function evaluations to identify optimal or near-optimal solutions. Reducing the number of evaluations can result in significant time savings, especially if the objective function is computationally expensive. CGS reduces the evaluation count by using a Bayesian network classifier to filter out non-promising candidate designs, prior to evaluation, based on their posterior probabilities. In this project, both the single-objective and multi-objective versions of the CGS are developed and tested on a set of benchmark problems. As a domain-specific case study, CGS is used to design a microgrid for use in islanded mode during an extended bulk power grid outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Configuration mixing in 28 Mg and the 26 Mg (t,p) 28 Mg reaction

We have studied the 26 Mg(t,p) 28 Mg reaction. The nucleus 28 Mg lies between 24 Mg and 32 Mg, the latter of which is central to the “island of inversion” characterized by low-lying neutron fp-shell configurations. The present results show that the second-excited 0 + state in 28 Mg contains large fp-shell occupation for the neutrons. The experiment was performed in inverse kinematics using the HELIcal Orbit Spectrometer (HELIOS) at Argonne National Laboratory. Shell-model calculations using the SDPF-MU interaction yielded level energies and two-neutron transfer amplitudes that were used in one-step distorted-wave Furthermore, born approximation calculations to provide theoretical predictions of the proton angular distributions. In many, but not all cases, the data were in good agreement with theoretical predictions.

20 ≤ A ≤ 38↗

Stepped hosting capacity for maximizing distributed solar on Guam

Guam Power Authority (GPA) sought national lab assistance through the Energy Technology Innovations Partnership Project as part of the second cohort of applicants (i.e. the program’s second year). GPA is leading an effort to evolve the island’s energy generation portfolio to 50% renewable by 2030, and 100% renewable by 2040. These goals for renewable penetration are a function of public law and GPA is legally required to comply, though GPA’s timeline is more aggressive by five years in each case than the law requires.

14 SOLAR ENERGY↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic Analysis of Complex Nuclear Fuel Cycles with NE-COST

The purpose of this work is to present a new methodology, and associated computational tools, developed within the U.S. Department of Energy (U.S. DOE) Fuel Cycle Option Campaign to quantify the economic performance of complex nuclear fuel cycles. The levelized electricity cost at the busbar is generally chosen to quantify and compare the economic performance of different baseload generating technologies, including of nuclear: it is the cost of electricity which renders the risk-adjusted discounted net present value of the investment cash flow equal to zero. The work presented here is focused on the calculation of the levelized cost of electricity of fuel cycles at mass balance equilibrium, which is termed LCAE (Levelized Cost of Electricity at Equilibrium). To alleviate the computational issues associated with the calculation of the LCAE for complex fuel cycles, a novel approach has been developed, which has been called the “island approach” because of its logical structure: a generic complex fuel cycle is subdivided into subsets of fuel cycle facilities, called islands, each containing one and only one type of reactor or blanket and an arbitrary number of fuel cycle facilities. A nuclear economic software tool, NE-COST, written in the commercial programming software MATLAB®, has been developed to calculate the LCAE of complex fuel cycles with the “island” computational approach. NE-COST has also been developed with the capability to handle uncertainty: the input parameters (both unit costs and fuel cycle characteristics) can have uncertainty distributions associated with them, and the output can be computed in terms of probability density functions of the LCAE. In this paper NE-COST will be used to quantify, as examples, the economic performance of (1) current Light Water Reactors (LWR) once-through systems; (2) continuous plutonium recycling in Fast Reactors (FR) with driver and blanket; (3) Recycling of plutonium bred in FR into LWR. For each fuel cycle, the contributions to the total LCAE of the main cost components will be identified.

Fuel Cycles↗