Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Guest Editorial: Special Issue on recent advancements in electric power system planning with high-penetration of renewable energy resources and dynamic loads

The goal of this Special Issue is to present the state-of-the-art methodologies developed for expansion planning of all segments of the modern power systems, characterized by separated businesses, high penetration of renewable resources and new load types, as well as by application of technologically advanced solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller (Final Report)

This report contains information regarding the activities carried out in the project "A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller. The project aims at developing a community-based flexible microgrid (FMG) with smart grid features, including multiple utility feeders and dynamic boundaries that utilize intelligent switches and ultra-high-speed communication links already in a smart grid. The project also aims at developing a corresponding controller for such an FMG with low cost and high scalability. With distributed renewable energy resources (DERs) and the intelligent microgrid controller, the FMG will achieve aggressive emission reduction, increased energy use efficiency, and reliability improvement goals. The FMG and its controller design will be scalable for different geographic areas, load sizes, distributed generation source number and types, and even multiple MGs within a distribution electric power system. In order to achieve these project objectives, three main development tasks were carried out: FMG design, FMG controller development, and FMG controller testing. The fourth task was technology to market.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SynthEsizing Novel H2 Sensors for Operational Resilience in Pipeline Infrastructure (SENSOR) (CRADA Final Report)

Hydrogen (H₂) is gaining attention as a versatile energy carrier with potential applications across industrial processes, power generation, and transportation. However, its practical deployment, particularly in large-scale distribution systems, faces significant infrastructure challenges. Transporting hydrogen through dedicated pipelines or blending it into existing natural gas networks can lead to serious issues, such as leakage due to the small size of hydrogen molecules and material degradation in pipelines through embrittlement. These technical risks raise safety concerns and could limit the integration of hydrogen into current energy infrastructures. Additionally, using hydrogen-enriched gas mixtures in combustion systems like turbines and engines introduces new performance and compatibility challenges that must be resolved before widespread use becomes feasible.

08 HYDROGEN↗

Coal Feed-Dependent Variation in Fly Ash Chemistry in a Single Pulverized-Combustion Unit

Four suites of fly ash, all generated at the same power plant, were selected for the study of the distribution of rare earth elements (REE). The fly ashes represented two runs of single-seam/single-mine coals and two runs of run-of-mine coals representing several coal seams from several mines. Plots of the upper continental crust-normalized REE, other parameters derived from the normalization, and the principal components analysis of the derived REE parameters (including the sum of the lanthanides plus yttrium and the ratio of the light to heavy REE) all demonstrated that the relatively rare earth-rich Fire Clay coal-derived fly ashes have a different REE distribution, with a greater concentration of REE with a relative dominance of the heavy REE, than the other fly ashes. Particularly with the Fire Clay coal-derived fly ashes, there is a systematic partitioning of the overall amount and distribution of the REE in the passage from the mechanical fly ash collection through to the last row of the electrostatic precipitator hoppers.

58 GEOSCIENCES↗

Comparative performance of solar thermal power generation concepts

A performance comparison is made between the central receiver system (power tower) and a distributed system using either dishes or troughs and lines to transport fluids to the power station. These systems were analyzed at a rated capacity of 30 MW of thermal energy delivered in the form of superheated steam at 538 C (1000 F) and 68 atm (1000 psia), using consistent weather data, collector surface waviness, pointing error, and electric conversion efficiency. The comparisons include technical considerations for component requirements, land utilization, and annual thermal energy collection rates. The relative merits of different representative systems are dependent upon the overall conversion as expressed in the form of performance factors in this paper. These factors are essentially indices of the relative performance effectiveness for different concepts based upon unit collector area. These performance factors enable further economic tradeoff studies of systems to be made by comparing them with projected production costs for these systems.

Wen, L.↗

Power electronics for low power arcjets

In anticipation of the needs of future light-weight, low-power spacecraft, arcjet power electronics in the 100 to 400 W operating range were developed. Limited spacecraft power and thermal control capacity of these small spacecraft emphasized the need for high efficiency. Power topologies similar to those in the higher 2 kW and 5 to 30 kW power range were implemented, including a four transistor bridge switching circuit, current mode pulse-width modulated control, and an output current averaging inductor with an integral pulse generation winding. Reduction of switching transients was accomplished using a low inductance power distribution network, and no passive snubber circuits were necessary for power switch protection. Phase shift control of the power bridge was accomplished using an improved pulse width modulation to phase shift converter circuit. These features, along with conservative magnetics designs allowed power conversion efficiencies of greater than 92.5 percent to be achieved into resistive loads over the entire operating range of the converter. Electromagnetic compatibility requirements were not considered in this work, and control power for the converter was derived from AC mains. Addition of input filters and control power converters would result in an efficiency of on the order of 90 percent for a flight unit. Due to the developmental nature of arcjet systems at this power level, the exact nature of the thruster/power processor interface was not quantified. Output regulation and current ripple requirements of 1 and 20 percent respectively, as well as starting techniques, were derived from the characteristics of the 2 kW system but an open circuit voltage in excess of 175 V was specified. Arcjet integration tests were performed, resulting in successful starts and stable arcjet operation at power levels as low as 240 W with simulated hydrazine propellants.

Hamley, John A.↗

Power electronics for low power arcjets

In anticipation of the needs of future light-weight low-power spacecraft, arcjet power electronics in the 100- to 400-W operating range were developed. Power topologies similar to those in the higher 2-kW and 5- to 30-kW power range were implemented, including a four-transistor bridge-switching circuit, current-mode pulse-width modulated control, and an output current averaging inductor with an integral pulse generation winding. Reduction of switching transients was accomplished using a low inductance power distribution network, and no passive snubber circuits were necessary for power switch protection. Phase shift control of the power bridge was accomplished using an improved pulse width modulation to phase shift converter circuit. These features, along with conservative magnetics designs, allowed power conversion efficiencies of greater than 92.5 percent to be achieved into resistive loads over the entire operating range of the converter.

Hamley, John A.↗

Electric Power System Technology Options for Lunar Surface Missions

In 2004, the President announced a 'Vision for Space Exploration' that is bold and forward-thinking, yet practical and responsible. The vision explores answers to longstanding questions of importance to science and society and will develop revolutionary technologies and capabilities for the future, while maintaining good stewardship of taxpayer dollars. One crucial technology area enabling all space exploration is electric power systems. In this paper, the author evaluates surface power technology options in order to identify leading candidate technologies that will accomplish lunar design reference mission three (LDRM-3). LDRM-3 mission consists of multiple, 90-day missions to the lunar South Pole with 4-person crews starting in the year 2020. Top-level power requirements included a nominal 50 kW continuous habitat power over a 5-year lifetime with back-up or redundant emergency power provisions and a nominal 2-kW, 2-person unpressurized rover. To help direct NASA's technology investment strategy, this lunar surface power technology evaluation assessed many figures of merit including: current technology readiness levels (TRLs), potential to advance to TRL 6 by 2014, effectiveness of the technology to meet the mission requirements in the specified time, mass, stowed volume, deployed area, complexity, required special ground facilities, safety, reliability/redundancy, strength of industrial base, applicability to other LDRM-3 elements, extensibility to Mars missions, costs, and risks. For the 50-kW habitat module, dozens of nuclear, radioisotope and solar power technologies were down-selected to a nuclear fission heat source with Brayton, Stirling or thermoelectric power conversion options. Preferred energy storage technologies included lithium-ion battery and Proton Exchange Membrane (PEM) Regenerative Fuel Cells (RFC). Several AC and DC power management and distribution architectures and component technologies were defined consistent with the preferred habitat power generation technology option and the overall lunar surface mission. For rover power, more than 20 technology options were down-selected to radioisotope Stirling, liquid lithium-ion battery, PEM RFC, or primary fuel cell options. The author discusses various conclusions that can be drawn from the findings of this surface power technologies evaluation.

Kerslake, Thomas W.↗

Computational Study of Flow Interactions in Coaxial Rotors

Although the first idea of coaxial rotors appeared more than 150 years ago, most helicopters have used single main-rotor/tail-rotor combination. Since reactive moments of coaxial rotors are canceled by contra-rotation, no tail rotor is required to counter the torque generated by the main rotor. Unlike the single main rotor design that distributes power to both main and tail rotors, all of the power for coaxial rotors is used for vertical thrust. Thus, no power is wasted for anti-torque or directional control. The saved power helps coaxial rotors reach a higher hover ceiling than single rotor helicopters. Another advantage of coaxial rotors is that the overall rotor diameter can be reduced for a given vehicle gross weight because each rotor provides a maximum contribution to vertical thrust to overcome vehicle weight. However, increased mechanical complexity of the hub has been one of the challenges for manufacturing coaxial rotorcraft. Only the Kamov Design Bureau of Russia had been notably successful in production of coaxial helicopters until Sikorsky built X2, an experimental compound helicopter. Recent developments in unmanned aircraft systems and high-speed rotorcraft have renewed interest in the coaxial configuration. Multi-rotors are frequently used for small electric unmanned rotorcraft partly due to mechanical simplicity. The use of multiple motors provides redundancy as well as cost-efficiency. The multi-rotor concept has rarely been used until recently because of its inherent stability and control problems. However, advances in inexpensive electronic flight control systems have opened the floodgates for small drones using multirotors. Coaxial rotors have started to appear in some multi-rotor configurations. Small coaxial rotors have often been designed using a hundred year old approach that is "sketch, build, fly, and iterate." In that approach, there is no systematic way to explore trade-offs or determine logical next steps. It is neither possible to account for multiple real-world constraints up front in design nor possible to know what performance is possible with a given design. Since unmanned vehicles are sized and optimized for the particular mission, a modern low-fidelity conceptual design and sizing tool that has been used for the design of large helicopters can be used for design of small coaxial rotorcraft. However, unlike most helicopters with single main rotor, the interactions between the upper and lower rotors emerge as an important factor to consider in design because an increase in performance of a multi-rotor system is not proportional to the number of rotors. Interference losses and differences in thrusts between the upper and lower rotors were investigated by theoretical methods as well as a computational fluid dynamics (CFD) method using the Reynolds-Averaged Navier-Stokes (RANS) equations. In this work, hybrid turbulence models are used to investigate the physics of interactions between coaxial rotors and a fuselage that are not well understood. Present study covers not only small-scale drones but also large-scale coaxial rotors for heavy-lifting missions. Considering the recently proposed FAA drone rules that require the flight only in visual line-of-sight, a large multirotor might be used as an airborne carrier for launch and recovery of unmanned aircraft systems with a human operator onboard. For applications to civil operations, their aerodynamic performance and noise levels need to be assessed. Noise is one of the largest limiting factors to rotorcraft operations in urban area. Since the high-frequency noise of multi-rotors may increase the annoyance, noise may turn out to be a key issue that must be addressed for market acceptability. One of the objectives of the present work is to study the effects of inter-rotor spacing and collectives on the performance, efficiency, and acoustics of coaxial rotor systems.

Study↗

Waveform Modulation of Locked PIC Lasers for Microwave Photonic Radars

In a conventional radar or radiometer system, microwave or millimeter-wave signals are generated, distributed, and processed using electronic components that have considerable size, weight, and power (SWaP) and are typically limited in bandwidth and immunity to electromagnetic interference. Radar waveform modulation was achieved via phase and amplitude modulation of one of the two mixed laser signals enabling the use of highly developed photonic modulation technology.

Victor Torres↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy, Exergy, Entropy Generation Minimization, and Exergoenvironmental Analyses of Energy Systems-A Mini-Review

Meeting the growing energy demands has become a crucial challenge, which should employ energy integration and benefit from the extraction of the maximum thermodynamic potential of the resources consumed. This brief review presents an overview of the essential elements of the methods of energy, exergy, entropy generation minimization, and exergoenvironmental analyses. In combination, these methodologies constitute a powerful toolbox for the design, analysis, and optimization of energy systems. The quantification of energy and environmental impacts provided by them is essential in guiding toward system designs that are consistent with current energy and environmental needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗