Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Display Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Natural optical activity as the origin of the large chiroptical properties in π-conjugated polymer thin films

Polymer thin films that emit and absorb circularly polarised light have been demonstrated with the promise of achieving important technological advances; from efficient, high-performance displays, to 3D imaging and all-organic spintronic devices. However, the origin of the large chiroptical effects in such films has, until now, remained elusive. We investigate the emergence of such phenomena in achiral polymers blended with a chiral small-molecule additive (1-aza[6]helicene) and intrinsically chiral-sidechain polymers using a combination of spectroscopic methods and structural probes. We show that – under conditions relevant for device fabrication – the large chiroptical effects are caused by magneto-electric coupling (natural optical activity), not structural chirality as previously assumed, and may occur because of local order in a cylinder blue phase-type organisation. This disruptive mechanistic insight into chiral polymer thin films will offer new approaches towards chiroptical materials development after almost three decades of research in this area.

36 MATERIALS SCIENCE↗

Visual Style Elements in Human–System Interface Design for Nuclear Power Operations: Does Style Affect Performance and Preference?

As the world increasingly adopts renewable and sustainable energy systems, transitionary solutions include nuclear power, which currently provides 20% of the United States’ electricity and is the largest single source of carbon-free electricity generation. Advanced reactors are a critical component of a carbon-free mixed energy portfolio that require careful design of first-of-a-kind control rooms. The application of Human Factors Engineering (HFE) is essential for scientific and iterative testing of novel human–system interface (HSI) concepts to ensure effective, efficient, and safe plant operations. Microworlds are simulators that use simplified physics models and control systems to distill nuclear power operations into essential functions. HFE scientists used the Rancor Microworld Simulator to obtain preference and performance metrics for novel and traditional static HSI design styles. Participants comprised advanced reactor company employees and nuclear industry consultants. A mixture of quantitative and qualitative data was captured. There was a preference for the basic graphical style that included high contrast and traditional color scheme elements. No single HSI design outperformed the others, and the participants did not perform better using their preferred HSI style. We report this experiment is the first in a series of HFE testing for HSIs in advanced reactor control room development. Clear user preferences emerged for elements within static displays. The cutting-edge neumorphic style was the least preferred. Future directions include tests of dynamic displays. HFE is used in evaluating and designing HSI devices that will improve the efficiency and safety of advanced nuclear power operations.

99 GENERAL AND MISCELLANEOUS↗

An interactive modeling program for the generation of planar polygons for boundary type solids representations of wire frame models

The development of a general link between three dimensional wire frame models and rigid solid models is discussed. An interactive computer graphics program was developed to serve as a front end to an algorithm (COSMIC Program No. ARC-11446) which offers a general solution to the hidden line problem where the input data is either line segments of n-sided planar polygons of the most general type with internal boundaries. The program provides a general interface to CAD/CAM data bases and is implemented for models created on the Unigraphics VAX 11/780-based CAD/CAM systems with the display software written for DEC's VS11 color graphics devices.

Ozsoy, T.↗

Contouring Trivariate Data

In many applications, the data consist of discrete 3-D points at which one or more parameters are given. To display contours, the data are represented by a continuous function which is evaluated at any point as needed for contouring. Contouring results are presented which are applicable both to artitrarily spaced data and to data which lie on a topologically rectangular three dimensional grid. the contours are assumed to be described by 3-D display lists for viewing on a dynamic color graphics device; that is, they will not simply be projected into 2-D and viewed as a static image on a frame buffer. Dynamic viewing of color contours may be essential to the proper interpretation of results. The gridded data lie on a topologically rectangular grid although two or more nodes may be the same point. Parametric tensor product methods may be used to fit the gridded data and to generate the contours. Rectangular elements are convenient but not necessary. For example, there are other methods which are effective for contouring over tetrahedral elements.

Stead, S. E.↗

Design Principles for Nickel/Hydrogen Cells and Batteries

Individual-pressure-vessel (IPV) nickel/hydrogen cells and bipolar batteries developed for use as energy-storage subsystems for satelite applications. Design principles applied draw upon extensive background in separator technology, alkaline-fuel-cell technology and several alkaline-cell technology areas. Principals are rather straightforward applications of capillary-force formalisms, coupled with slowly developing data base resulting from careful post-test analyses. Based on preconceived assumptions relative to how devices work and how to be designed so they display longer cycle lives at deep discharge.

Thaller, Lawrence H.↗

The locator system for wandering individuals

Configurations and operation strategies are described for a wanderer locator system based on wireless radio frequency communication designed to monitor elderly patients who may wander beyond safe perimeters in the home or in an institutional setting. The modular components of this wandering notification system are (1) portable transmitter/receivers to be worn or carried by the patient and the caretaker, (2) detectors to be mounted in doorways or other perimeters of a safe area, (3) programmable central processing units to control, communicate with, and/or trace the portable and remote devices, and (4) a cathode ray tube that can display information on patient location or system status. Photographs of all system components and illustrations of operations concepts are included.

Davidson, Shayla↗

Influence of Sm2O3 addition on Judd-Ofelt parameters, thermal and optical properties of the TeO2-Li2O-ZnO-Nb2O5 glass system

Highlights: • Synthesis of Sm{sub 2}O{sub 3} doped TeO{sub 2}-Li{sub 2}O-ZnO-Nb{sub 2}O{sub 5} glass to be used in optical devices. • Area under the peak calculations of FTIR and Raman display higher presence of BOs. • DSC plots indicate high stability and high rigidity of prepared glass samples. • Judd-Ofelt analysis shows the ionic nature of Sm{sup 3+} ions with neighboring atoms. • Higher branching ratio values obtained from {sup 6}H{sub 5/2} → {sup 6}F{sub 5/2} emission transition. - Abstract: A series of transparent and light yellow color samples composed of Sm{sub 2}O{sub 3} doped tellurium oxide glasses with chemical composition 75TeO{sub 2}-5Li{sub 2}O-10ZnO-(10-X) Nb{sub 2}O{sub 5}-XSm{sub 2}O{sub 3} was prepared by conventional melt-quenching technique. Rare earth (Sm{sub 2}O{sub 3}) was added to improve all glass properties. From obtained radiative properties, the samples which prepared with above composition can be considered as a prospect application for laser design due to higher branching ratio. The physical properties including sample density, molar volume, and OPD were measured. The glassy nature is approved by XRD analysis. The structural modification of glass forming units with introducing Sm{sub 2}O{sub 3} was studied by FTIR and Raman spectra. The intensity ratio of TeO{sub 4}/TeO{sub 3} was measured to determine the ratio of bridging/non-bridging oxygen exists in glass network. Glass thermal stability, glass transition temperature, and melting temperature were obtained from DSC plots. The UV–vis-NIR absorption spectra display 9 peaks. Optical parameters including optical band gap E{sub Opt}, Urbach energy ΔE and refractive index n were determined. From absorption spectra, Judd-Ofelt intensity parameters (Ω{sub λ} and λ = 2, 4, 6) have been derived to study bonding nature. A spectroscopic quality factor was calculated. Branching ratio (β{sub r}) and lifetime (τ) have been calculated using JO parameters. Absorption and emission cross-sections were determined to measure the probability of an absorption or emission process. Finally, we propose that these prepared samples can be used in optical devices and other applications.

36 MATERIALS SCIENCE↗

Forecasting hotspots using predictive visual analytics approach

A method for forecasting hotspots is provided. The method may include the steps of receiving input data at an input of the computational device, generating a temporal prediction based on the input data, generating a geospatial prediction based on the input data, and generating output data based on the time series and geospatial predictions. The output data may be configured to display at least one user interface at an output of the computational device.

58 GEOSCIENCES↗

Restorative effect of oxygen annealing on device performance in HfIZO thin-film transistors

Metal-oxide based thin-film transistors (oxide-TFTs) are very promising for use in next generation electronics such as transparent displays requiring high switching and driving performance. In this study, we demonstrate an optimized process to secure excellent device performance with a favorable shift of the threshold voltage toward 0V in amorphous hafnium-indium-zinc-oxide (a-HfIZO) TFTs by using post-treatment with oxygen annealing. This enhancement results from the improved interfacial characteristics between gate dielectric and semiconductor layers due to the reduction in the density of interfacial states related to oxygen vacancies afforded by oxygen annealing. The device statistics confirm the improvement in the device-to-device and run-to-run uniformity. We also report on the photo-induced stability in such oxide-TFTs against long-term UV irradiation, which is significant for transparent displays.

36 MATERIALS SCIENCE↗

Beyond the cockpit: The visual world as a flight instrument

The use of cockpit instruments to guide flight control is not always an option (e.g., low level rotorcraft flight). Under such circumstances the pilot must use out-the-window information for control and navigation. Thus it is important to determine the basis of visually guided flight for several reasons: (1) to guide the design and construction of the visual displays used in training simulators; (2) to allow modeling of visibility restrictions brought about by weather, cockpit constraints, or distortions introduced by sensor systems; and (3) to aid in the development of displays that augment the cockpit window scene and are compatible with the pilot's visual extraction of information from the visual scene. The authors are actively pursuing these questions. We have on-going studies using both low-cost, lower fidelity flight simulators, and state-of-the-art helicopter simulation research facilities. Research results will be presented on: (1) the important visual scene information used in altitude and speed control; (2) the utility of monocular, stereo, and hyperstereo cues for the control of flight; (3) perceptual effects due to the differences between normal unaided daylight vision, and that made available by various night vision devices (e.g., light intensifying goggles and infra-red sensor displays); and (4) the utility of advanced contact displays in which instrument information is made part of the visual scene, as on a 'scene linked' head-up display (e.g., displaying altimeter information on a virtual billboard located on the ground).

Johnson, W. W.↗

Spacecraft 3D Augmented Reality Mobile App

The Spacecraft 3D application allows users to learn about and interact with iconic NASA missions in a new and immersive way using common mobile devices. Using Augmented Reality (AR) techniques to project 3D renditions of the mission spacecraft into real-world surroundings, users can interact with and learn about Curiosity, GRAIL, Cassini, and Voyager. Additional updates on future missions, animations, and information will be ongoing. Using a printed AR Target and camera on a mobile device, users can get up close with these robotic explorers, see how some move, and learn about these engineering feats, which are used to expand knowledge and understanding about space. The software receives input from the mobile device's camera to recognize the presence of an AR marker in the camera's field of view. It then displays a 3D rendition of the selected spacecraft in the user's physical surroundings, on the mobile device's screen, while it tracks the device's movement in relation to the physical position of the spacecraft's 3D image on the AR marker.

Hussey, Kevin J.↗

Test and evaluation of a multifunction keyboard and a dedicated keyboard for control of a flight management computer

A flight management computer (FMC) control display unit (CDU) test was conducted to compare two types of input devices: a fixed legend (dedicated) keyboard and a programmable legend (multifunction) keyboard. The task used for comparison was operation of the flight management computer for the Boeing 737-300. The same tasks were performed by twelve pilots on the FMC control display unit configured with a programmable legend keyboard and with the currently used B737-300 dedicated keyboard. Flight simulator work activity levels and input task complexity were varied during each pilot session. Half of the points tested were previously familiar with the B737-300 dedicated keyboard CDU and half had no prior experience with it. The data collected included simulator flight parameters, keystroke time and sequences, and pilot questionnaire responses. A timeline analysis was also used for evaluation of the two keyboard concepts.

Crane, J. M.↗

Self-Assembly of an α-Helical Peptide into a Crystalline Two-Dimensional Nanoporous Framework

Sequence-specific peptides have been demonstrated to self-assemble into structurally defined nanoscale objects including nanofibers, nanotubes, and nanosheets. The latter structures display significant promise for the construction of hybrid materials for functional devices due to their extended planar geometry. Realization of this objective necessitates the ability to control the structural features of the resultant assemblies through the peptide sequence. The design of a amphiphilic peptide, 3FD-IL, is described that comprises two repeats of a canonical 18 amino acid sequence associated with straight α-helical structures. Peptide 3FD-IL displays 3-fold screw symmetry in a helical conformation and self-assembles into nanosheets based on hexagonal packing of helices. Biophysical evidence from TEM, cryo-TEM, SAXS, AFM, and STEM measurements on the 3FD-IL nanosheets support a structural model based on a honeycomb lattice, in which the length of the peptide determines the thickness of the nanosheet and the packing of helices defines the presence of nanoscale channels that permeate the sheet. The honeycomb structure can be rationalized on the basis of geometrical packing frustration in which the channels occupy defect sites that define a periodic superlattice. In conclusion, the resultant 2D materials may have potential as materials for nanoscale transport and controlled release applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.

60 APPLIED LIFE SCIENCES↗

Use of a Frequency Divider to Evaluate an SOI NAND Gate Device, Type CHT-7400, for Wide Temperature Applications

Frequency dividers constitute essential elements in designing phase-locked loop circuits and microwave systems. In addition, they are used in providing required clocking signals to microprocessors and can be utilized as digital counters. In some applications, particularly space missions, electronics are often exposed to extreme temperature conditions. Therefore, it is required that circuits designed for such applications incorporate electronic parts and devices that can tolerate and operate efficiently in harsh temperature environments. While present electronic circuits employ COTS (commercial-off- the-shelf) parts that necessitate and are supported with some form of thermal control systems to maintain adequate temperature for proper operation, it is highly desirable and beneficial if the thermal conditioning elements are eliminated. Amongst these benefits are: simpler system design, reduced weight and size, improved reliability, simpler maintenance, and reduced cost. Devices based on silicon-on-insulator (SOI) technology, which utilizes the addition of an insulation layer in the device structure to reduce leakage currents and to minimize parasitic junctions, are well suited for high temperatures due to reduced internal heating as compared to the conventional silicon devices, and less power consumption. In addition, SOI electronic integrated circuits display good tolerance to radiation by virtue of introducing barriers or lengthening the path for penetrating particles and/or providing a region for trapping incident ionization. The benefits of these parts make them suitable for use in deep space and planetary exploration missions where extreme temperatures and radiation are encountered. Although designed for high temperatures, very little data exist on the operation of SOI devices and circuits at cryogenic temperatures. In this work, the performance of a divide-by-two frequency divider circuit built using COTS SOI logic gates was evaluated over a wide temperature range and thermal cycling to determine suitability for use in space exploration missions and terrestrial fields under extreme temperature conditions.

Patterson, Richard L.↗

Effect of environmental enrichment devices on behaviors of single- and group-housed squirrel monkeys (Saimiri sciureus)

Squirrel monkeys display an interest in novel places, habituate to new situations, and spend most of their daily activity in the wild in large groups engaging in feeding behaviors over a broad area. Captivity limits these behaviors and consequently may disrupt normal social organizations. In captivity, squirrel monkeys may exhibit stereotypical behaviors that are believed to indicate decreased psychologic well-being. When a monkey's behavior can be made to approach that seen in the wild, and stereotypical behaviors are minimal, it is assumed that psychologic well-being is adequate. Environmental enrichment devices have been used to address the Animal Welfare Act requirement that psychologic well-being of captive nonhuman primates be considered. The purpose of the study reported here was to examine whether various environmental enrichment devices improve the psychologic well-being of captive squirrel monkeys. In the study, we used behavioral observation to quantify the effectiveness of several environmental enrichment devices for reducing stereotypical behaviors in squirrel monkeys housed alone or in groups. Analysis of our results revealed that the environmental enrichment devices did not affect the expression of normal or stereotypical behaviors, but that the type of housing did.

NASA Discipline Neuroscience↗

Alkaline earth stannates: The next silicon?

Semiconductor materials are being used in an increasingly diverse array of applications, with new device concepts being proposed each year for solar cells, flat-panel displays, sensors, memory, and spin transport. This rapid progress of invention outpaces the development of new semiconductor materials with the required properties and performance. In many applications, high carrier mobility at room temperature is required in addition to specific functional properties critical to the device concept. We review recent developments on high mobility stannate perovskite oxide materials and devices.

36 MATERIALS SCIENCE↗