Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Evaluation of clear-sky and satellite-derived irradiance data for determining the degradation of photovoltaic system performance

Knowing the degradation in performance of a photovoltaic (PV) system over time is important for estimating the lifetime energy produced and the financial return. A key parameter for normalizing performance and determining degradation is the plane-of-array (POA) irradiance. Because accurate long-term POA measurements are not always readily available, three methods of providing irradiance data for determining the degradation rate of PV systems were evaluated—a method using irradiance data modeled with the Ineichen clear-sky model and monthly Linke turbidity coefficients, a method using the supplemental clear-sky irradiance data from the National Solar Radiation Data Base (NSRDB), and a method using the NSRDB solar irradiance data for both cloudy and clear-sky conditions (all-sky). The irradiance data from the three methods were evaluated using measured irradiance data from 1998 through 2018 for the seven-station SURFRAD network and for 3-, 5-, and 10-year periods that might be used for evaluating PV system performance. Only the two clear-sky methods for the 10-year periods had less uncertainty with respect to determining PV system degradation than the expected median degradation rate for PV systems of -0.5%/year to -0.6%/year. Shorter periods and the all-sky method had larger uncertainties, making their use questionable for determining the degradation rates of PV systems.

14 SOLAR ENERGY↗

Comparing probabilistic and descriptive analyses of time–dose–toxicity relationship for determining no-observed-adverse-effect level in drug development

The no-observed-adverse-effect level (NOAEL) of a drug defined from animal studies is important for inferring a maximal safe dose in human. However, several issues are associated with its concept, determination and application. It is confined to the actual doses used in the study; becomes lower with increasing sample size or dose levels; and reflects the risk level seen in the experiment rather than what may be relevant for human. We explored a pharmacometric approach in an attempt to address these issues. We first used simulation to examine the behaviour of the NOAEL values as determined by current common practice; and then fitted the probability of toxicity as a function of treatment duration and dose to data collected from all applicable toxicology studies of a test compound. Our investigation was in the context of an irreversible toxicity that is detected at the end of the study. Simulations illustrated NOAEL's dependency on experimental factors such as dose and sample size, as well as the underlying uncertainty. Modelling the probability as a continuous function of treatment duration and dose simultaneously to data from multiple studies allowed the estimation of the dose, along with its confidence interval, for a maximal risk level that might be deemed as acceptable for human. The model-based data integration also reconciled between-study inconsistency and explicitly provided maximised estimation confidence. Such alternative NOAEL determination method should be explored for its more efficient data use, more quantifiable insight to toxic doses, and the potential for more relevant animal-to-human translation. - Highlights: • Simulations revealed issues with NOAEL concept, determination and application. • Probabilistic modelling was used to address these issues. • The model integrated time-dose-toxicity data from multiple studies. • The approach uses data efficiently and may allow more meaningful human translation.

60 APPLIED LIFE SCIENCES↗

Determination of total chlorine and bromine in solid wastes by sintering and inductively coupled plasma-sector field mass spectrometry

A sample preparation method based on sintering, followed by analysis by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) for the simultaneous determination of chloride and bromide in diverse and mixed solid wastes, has been evaluated. Samples and reference materials of known composition were mixed with a sintering agent containing Na{sub 2}CO{sub 3} and ZnO and placed in an oven at 560 deg. C for 1 h. After cooling, the residues were leached with water prior to a cation-exchange assisted clean-up. Alternatively, a simple microwave-assisted digestion using only nitric acid was applied for comparison. Thereafter the samples were prepared for quantitative analysis by ICP-SFMS. The sintering method was evaluated by analysis of certified reference materials (CRMs) and by comparison with US EPA Method 5050 and ion chromatography with good agreement. Median RSDs for the sintering method were determined to 10% for both chlorine and bromine, and median recovery to 96% and 97%, respectively. Limits of detection (LODs) were 200 mg/kg for chlorine and 20 mg/kg for bromine. It was concluded that the sintering method is suitable for chlorine and bromine determination in several matrices like sewage sludge, plastics, and edible waste, as well as for waste mixtures. The sintering method was also applied for determination of other elements present in anionic forms, such as sulfur, arsenic, selenium and iodine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample preparation and biomass determination of SRF model mixture using cryogenic milling and the adapted balance method

Highlights: • An alternative sample comminution procedure for SRF is tested. • Proof of principle is shown on a SRF model mixture. • The biogenic content of the SRF is analyzed with the adapted balance method. • The novel method combines combustion analysis and a data reconciliation algorithm. • Factors for the variance of the analysis results are statistically quantified. - Abstract: The biogenic fraction of a simple solid recovered fuel (SRF) mixture (80 wt% printer paper/20 wt% high density polyethylene) is analyzed with the in-house developed adapted balance method (aBM). This fairly new approach is a combination of combustion elemental analysis (CHNS) and a data reconciliation algorithm based on successive linearisation for evaluation of the analysis results. This method shows a great potential as an alternative way to determine the biomass content in SRF. However, the employed analytical technique (CHNS elemental analysis) restricts the probed sample mass to low amounts in the range of a few hundred milligrams. This requires sample comminution to small grain sizes (<200 μm) to generate representative SRF specimen. This is not easily accomplished for certain material mixtures (e.g. SRF with rubber content) by conventional means of sample size reduction. This paper presents a proof of principle investigation of the sample preparation and analysis of an SRF model mixture with the use of cryogenic impact milling (final sample comminution) and the adapted balance method (determination of biomass content). The so derived sample preparation methodology (cutting mills and cryogenic impact milling) shows a better performance in accuracy and precision for the determination of the biomass content than one solely based on cutting mills. The results for the determination of the biogenic fraction are within 1–5% of the data obtained by the reference methods, selective dissolution method (SDM) and {sup 14}C-method ({sup 14}C-M)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining the biomass fraction of mixed waste fuels: A comparison of existing industry and {sup 14}C-based methodologies

Highlights: • Compares industry standard and {sup 14}C methods for determining bioenergy content of MSW. • Differences quantified through study at an operational energy from waste plant. • Manual sort and selective dissolution are unreliable measures of feedstock bioenergy. • {sup 14}C methods (esp. AMS) improve precision and reliability of bioenergy determination. • Implications for electricity generators and regulators for award of bio-incentives. - Abstract: {sup 14}C analysis of flue gas by accelerator mass spectrometry (AMS) and liquid scintillation counting (LSC) were used to determine the biomass fraction of mixed waste at an operational energy-from-waste (EfW) plant. Results were converted to bioenergy (% total) using mathematical algorithms and assessed against existing industry methodologies which involve manual sorting and selective dissolution (SD) of feedstock. Simultaneous determinations using flue gas showed excellent agreement: 44.8 ± 2.7% for AMS and 44.6 ± 12.3% for LSC. Comparable bioenergy results were obtained using a feedstock manual sort procedure (41.4%), whilst a procedure based on selective dissolution of representative waste material is reported as 75.5% (no errors quoted). {sup 14}C techniques present significant advantages in data acquisition, precision and reliability for both electricity generator and industry regulator.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sub-Monolayer Accuracy in Determining the Number of Atoms per Unit Area in Ultrathin Films Using X-ray Fluorescence

We present that the composition and thickness of thin films determine their physical properties, making the ability to measure the number of atoms of different elements in films both technologically and scientifically important. For thin films, below a certain thickness, the X-ray fluorescence intensity of an element is proportional to the number of atoms. Converting this intensity to the number of atoms per unit area is challenging due to experimental geometries and other correction factors. Hence, the ratio of intensities is more commonly used to determine the composition in terms of element ratios using standards or a model. Here, the number of atoms per unit area was determined using X-ray structure information for over 20 different crystallographically aligned samples with integral unit cell thicknesses. The proportionality constant between intensity and the number of atoms per unit area was determined from linear fits of the background subtracted X-ray fluorescence intensity plotted versus the calculated number of atoms per unit area for each element. The results demonstrate that X-ray fluorescence is very sensitive, capable of measuring changes in the number of atoms of less than 1% of a monolayer for some elements in a variety of sample matrices. Finally, using the calibrated values, an 8 unit cell thick MoSe 2 was grown and characterized, demonstrating the usefulness of the ablity to quantify the number of atoms per unit area in a film.

36 MATERIALS SCIENCE↗

Improved Accuracy in Semi-Experimental Structure Determination by Resolving Problems Associated with Rotation of Principal Inertial Axes of Isotopologues: Structures of 1,3-Oxazole ( c -C 3 H 3 NO)

The rotational spectrum of the normal isotopologue of 1,3-oxazole (c-C 3 H 3 NO) was observed from 43 to 750 GHz. Over 3900 transitions for the ground vibrational state are measured, assigned, and least-squares fit to sextic centrifugally distorted-rotor Hamiltonians. The measured frequencies and resulting spectroscopic constants from this extended spectral range, combined with previous measurements of the nuclear quadrupole coupling constants, will facilitate astronomical searches for oxazole across the majority of the range of modern radiotelescopes. Spectra for a set of 30 oxazole isotopologues, which include multiple isotopic substitutions of each atom, are used to determine the first semi-experimental equilibrium ($r$$^{SE}_{e}$) structure and semi-experimental substitution structure ($r$$^{SE}_{e}$), each using CCSD(T) computed values for the vibration–rotation interaction and electron-mass corrections. The large number of isotopologues, including 21 isotopologues observed for the first time, and the redundant substitutions of each atom provide sufficient spectroscopic information to determine the $r$$^{SE}_{e}$ structure with the expected high level of accuracy and precision (0.0001 or 0.0002 Å in bond distances and 0.013 to 0.025° in bond angles). In the course of this study, we analyzed a known issue for some $r$$^{SE}_{e}$ structure determinations of near-oblate asymmetric tops in which inclusion of individual isotopologues degrades the structure determination. We demonstrate that this problem primarily arises from the difference in the values of the computed vibration–rotation interaction corrections as evaluated at the computed re geometry vs the $r$$^{SE}_{e}$ geometry of the “real” molecule. Our solution to this problem substantially improves the $r$$^{SE}_{e}$ structure of oxazole and likely can be generalized to many other molecules.

Chemical structure↗

Determination of the Maturation Status of Dendritic Cells by Applying Pattern Recognition to High-Resolution Images

The maturation or activation status of dendritic cells (DCs) directly correlates with their behavior and immunofunction. A common means to determine the maturity of dendritic cells is from high-resolution images acquired via scanning electron microscopy (SEM) or atomic force microscopy (AFM). While direct and visual, the determination has been made by directly looking at the images by researchers. Here we report a machine learning approach using pattern recognition in conjunction with cellular biophysical knowledge of dendritic cells to determine the maturation status of dendritic cells automatically. The determination from AFM images reaches 100% accuracy. The results from SEM images reaches 94.9%. The results demonstrate the accuracy of using machine learning for accelerating data analysis, extracting information, and drawing conclusions from high-resolution cellular images, paving the way for future applications requiring high-throughput and automation, such as cellular sorting and selection based on morphology, quantification of cellular structure, and DC-based immunotherapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing Machine Learning and Physics-Based Nanoparticle Geometry Determinations Using Far-Field Spectral Properties

Anisotropic metal nanostructures exhibit polarization-dependent light scattering, a property which has been widely studied and exploited to determine orientations of subwavelength structures using far-field microscopy. Here we explore the use of variational autoencoders (VAEs) to determine the geometries of gold nanorods (NRs) such as in-plane orientation and aspect ratio under linearly polarized dark-field illumination in an optical microscope. We enforce a shared latent space to connect two VAEs trained separately with polarized dark-field scattering spectra and electron microscopy images and achieve image prediction (shape, orientation, and size) of Au NRs using only polarized dark-field scattering spectra. We determine the geometrical parameters of orientational angle and aspect ratio quantitatively via both our dual-VAE and physics-based analysis on the input scattering spectra. We show that orientational angle prediction by dual-VAE performs well with only a small (~300 particle) training set, yielding a mean absolute error (MAE) of 14.4° and a concordance correlation coefficient (CCC) of 0.95. This performance is only marginally worse than the physics-based cos(2?) fitting approach between the scattering intensity and the polarizing angle, which achieves MAE of 8.78° and CCC of 0.99. Aspect ratio determination is also comparable for the dual-VAE and physics-based fitting comparison (MAE of 0.21 vs. 0.23 and CCC of 0.53 vs. 0.68). Here, this dual encoder-decoder architecture effectively exploits the structure-property relationships of plasmonic nanostructures to construct a cross-modal machine learning (ML) approach, providing a pathway to employ ML approaches to address other structure-property relationships in materials science.

Dark-field scattering↗

Measuring Plant Metabolite Abundance in Spearmint ( Mentha spicata L.) with Raman Spectra to Determine Optimal Harvest Time

A fast field-deployable method utilizing Raman spectroscopy to determine the optimal harvest time of plants to extract the highest abundance of target metabolites is presented. Rosmarinic acid is a metabolite extracted from spearmint (Mentha spicata L.). Leaves from commercial “Native” and proprietary clonal line “KI110” spearmint were measured as a function of cell type and age to determine rosmarinic acid abundance. A linear regression model with leave-one-out cross-validation (R 2 CV = 0.61, RMSECV = 11.1 mg/g) was developed between selected Raman peak areas and rosmarinic acid concentrations determined by high-performance liquid chromatography (HPLC). A principal component analysis (PCA) model was also developed to determine rosmarinic acid abundance. The method may be suited to the analysis of many agriculturally relevant plant species and metabolites with distinct Raman peaks.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of Phase Diagrams for Soluble and Membrane Protein Systems

Methods to efficiently determine the phase behavior of novel proteins have the potential to significantly benefit structural biology efforts. Here, we present protocols to determine both the solubility boundary and the supersolubility boundary for protein/precipitant systems using an evaporation-based crystallization platform. This strategy takes advantage of the well-defined rates of evaporation that occur in this platform to determine the state of the droplet at any point in time without relying on an equilibrium-based end point. The dynamic nature of this method efficiently traverses phase space along a known path, such that a solubility diagram can be mapped out for both soluble and membrane proteins while using a smaller amount of protein than what is typically used in optimization screens. Furthermore, a variation on this method can be used to decouple crystal nucleation and growth events, so fewer and larger crystals can be obtained within a given droplet. The latter protocol can be used to rescue a crystallization trial where showers of tiny crystals were observed. We validated both of the protocols to determine the phase behavior and the protocol to optimize crystal quality using the soluble proteins lysozyme and ribonuclease A as well as the membrane protein bacteriorhodopsin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of S-H Bond Strengths in Dimolybdenum Tetrasulfide Complexes

Homolytic solution bond dissociation free energies (sBDFE’s) for S-H bonds have been determined for soluble dimolybdenum tetrasulfide complexes through thermochemical cycles using electrochemical potentials and pK a values, all measured in acetonitrile. For [Cp*Mo(μ S)(μ SMe)2(μ SH)MoCp*]+ (S 4 Me 2 H + ), [Cp*Mo(μ S)(μ SMe)(μ SH)2MoCp*]+ (S 4 MeH 2 + ), and [Cp*Mo(μ S)(μ SH) 3 MoCp*] + (S 4 H 3 + ), the pKa values were determined to be 5.6 ± 0.4, 5.3 ± 0.3, and 4.9 ± 0.3, respectively. The E 1/2 values for S 4 Me 2 •+/o, S 4 MeH •+/o , and S 4 H 2 •+/o were measured to be -0.02 ± 0.02, +0.04 ± 0.05, and +0.07 ± 0.07 V vs FeCp 2 +/o , respectively. Using these experimental values, the homolytic S-H sBDFE for each S 4 RR’H + to S 4 RR’ •+ reaction was determined to be 60.8 ± 1.0, 61.8 ± 1.6, and 61.9 ± 2.0 kcal/mol for S 4 Me 2 H + , S 4 MeH 2+ , and S 4 H 3 + respectively. These sBDFE values can be used to estimate gas phase bond dissociation enthalpies of 65.6, 66.6, and 66.7 kcal/mol, respectively. The gas phase bond dissociation enthalpy for the analogous complex, Cp 2 Mo 2 S 4 Me 2 H + was determined to be 64.9 kcal/mol by electronic structure calculations. Solid state structures are presented for S 4 MeH and S 4 H 2 . The Pacific Northwest National Laboratory is operated y Battelle for the U.S. Department of Energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and efficient ambient temperature X-ray crystal structure determination at Turkish Light Source

High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroelectrochemical determination of thiolate self-assembled monolayer adsorptive stability in aqueous and non-aqueous electrolytes

Self-assembled monolayers (SAM) are ubiquitous in studies of modified electrodes for sensing, electrocatalysis, and environmental and energy applications. However, determining their adsorptive stability is crucial to ensure robust experiments. Here, in this work, the stable potential window (SPW) in which a SAM-covered electrode can function without inducing SAM desorption was determined for aromatic SAMs on gold electrodes in aqueous and non-aqueous solvents. The SPWs were determined by employing cyclic voltammetry, attenuated total reflectance surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS), and surface plasmon resonance (SPR). The electrochemical and spectroscopic findings concluded that all the aromatic SAMs used displayed similar trends and SPWs. In aqueous systems, the SPW lies between the reductive desorption and oxidative desorption, with pH being the decisive factor affecting the range of the SPW, with the widest SPW observed at pH 1. In the non-aqueous electrolytes, the desorption of SAMs was observed to be slow and progressive. The polarity of the solvent was the main factor in determining the SPW. The lower the polarity of the solvent, the larger the SPW, with 1-butanol displaying the widest SPW. This work showcases the power of spectroelectrochemical analysis and provides ample future directions for the use of non-polar solvents to increase SAM stability in electrochemical applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Use of Neutron Transfer Reactions to Indirectly Determine Neutron Capture Cross Sections on Neutron-Rich Nuclei

{sup 14}C(n,gamma){sup 15}C is being used as a test case in the development of an indirect method to determine neutron capture cross sections on neutron-rich unstable nuclei at astrophysical energies. Our approach makes use of two reactions: one peripheral used to find the asymptotic normalization coefficient (ANC) and a second non-peripheral reaction to determine the spectroscopic factor. The ANC for {sup 15}C has been determined using a HI neutron transfer reaction with a 12 MeV/nucleon {sup 14}C beam on a {sup 13}C target. The spectroscopic factor will be determined using {sup 14}C(d,p) in forward kinematics with an incident deuteron energy of 60 MeV. Both experiments were performed using the MDM high-resolution spectrometer at Texas A and M University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutrino mass hierarchy determination for theta{sub 13} = 0

We examine the possibility of determining the neutrino mass hierarchy in the limit theta{sub 13} = 0 using atmospheric neutrinos as the source. In this limit, theta{sub 13} driven matter effects are absent so independent measurements of DELTA{sub 31} and DELTA{sub 32} can, in principle, lead to hierarchy determination. Since their difference is DELTA{sub 21}, one needs an experimental arrangement where DELTA{sub 21}L/E > or approx. 1 can be achieved. This can be satisfied by atmospheric neutrinos which have a large range of L and E. Still, we find that hierarchy determination in the theta{sub 13} = 0 limit with atmospheric neutrinos is not a realistic possibility, even in conjunction with a beam experiment like T2K or NOnuA. We discuss why, and also reiterate the general conditions for hierarchy determination if theta{sub 13} = 0.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New approach of determinations of earthquake moment magnitude using near earthquake source duration and maximum displacement amplitude of high frequency energy radiation

The new approach method to determine the magnitude by using amplitude displacement relationship (A), epicenter distance ({Delta}) and duration of high frequency radiation (t) has been investigated for Tasikmalaya earthquake, on September 2, 2009, and their aftershock. Moment magnitude scale commonly used seismic surface waves with the teleseismic range of the period is greater than 200 seconds or a moment magnitude of the P wave using teleseismic seismogram data and the range of 10-60 seconds. In this research techniques have been developed a new approach to determine the displacement amplitude and duration of high frequency radiation using near earthquake. Determination of the duration of high frequency using half of period of P waves on the seismograms displacement. This is due tothe very complex rupture process in the near earthquake. Seismic data of the P wave mixing with other wave (S wave) before the duration runs out, so it is difficult to separate or determined the final of P-wave. Application of the 68 earthquakes recorded by station of CISI, Garut West Java, the following relationship is obtained: Mw = 0.78 log (A) + 0.83 log {Delta}+ 0.69 log (t) + 6.46 with: A (m), d (km) and t (second). Moment magnitude of this new approach is quite reliable, time processing faster so useful for early warning.

58 GEOSCIENCES↗

Determination of elastic properties of a MnO{sub 2} coating by surface acoustic wave velocity dispersion analysis

MnO{sub 2} is a material of interest in the development of high energy-density batteries, specifically as a coating material for internal 3D structures, thus ensuring rapid energy deployment. Its electrochemical properties have been mapped extensively, but there are, to the best of the authors' knowledge, no records of the elastic properties of thin film MnO{sub 2}. Impulsive stimulated thermal scattering (ISTS), also known as the heterodyne diffraction or transient grating technique, was used to determine the Young's modulus (E) and porosity (ψ) of a 500 nm thick MnO{sub 2} coating on a Si(001) substrate. ISTS is an all optical method that is able to excite and detect surface acoustic waves (SAWs) on opaque samples. From the measured SAW velocity dispersion, the Young's modulus and porosity were determined to be E = 25 ± 1 GPa and ψ=42±1%, respectively. These values were confirmed by independent techniques and determined by a most-squares analysis of the carefully fitted SAW velocity dispersion. This study demonstrates the ability of the presented technique to determine the elastic parameters of a thin, porous film on an anisotropic substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗