Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Spatial Registration Assessments for the SNPP and N20 VIIRS Reflective Solar Bands Using Unscheduled Lunar Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a multi-spectral Earth-observing instrument on board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecraft, with spectral bands ranging in wavelength from 0.41 to 12.2 μm. For the reflective solar bands (RSB), the bands are calibrated on orbit using both solar diffuser (SD) and lunar observations. The lunar observations use near-monthly scheduled spacecraft maneuvers in order to view the Moon within a desired phase angle range. While the primary purpose of the maneuvers is for radiometric calibration, these observations can also be used to characterize the spatial performance of the instrument, including the band-to-band and detector-to-detector registration (BBR/DDR). The Moon can also be observed without spacecraft maneuvers. However, these observations are over a larger phase angle range. While the geometry of these unscheduled observations is more varied, they can still be used to assess the sensor performance. In this work, we will use unscheduled Moon data to analyze the BBR and DDR of the SNPP and N20 VIIRS RSB. For the BBR, we implemented an image cross-correlation approach, which removes the residual oscillations in the trending data when compared to previous methodologies. For the DDR, we developed an edge fitting approach that accounts for the lunar motion across the VIIRS focal plane array on a scan-by-scan basis using lunar and satellite ephemeris data. In our analysis, we find that the BBR and DDR for both VIIRS RSB are stable on orbit.

Band-to-band registration (BBR)↗

A hard X ray and soft gamma ray telescope spectrometer

A telescope spectrometer in the hard X-ray and soft gamma-ray region from 30 keV to 200 keV can provide significant information in investigations related to solar physics and planetary science. The present study is concerned with the preliminary design of such an instrument, taking into account a use of the Low Intensity X-ray Imaging Scope (Lixiscope). In the design of the considered telescope spectrometer, attention would have to be given to three major components, including the X-ray and gamma-ray input optics, an imaging detector-spectrometer, and an output processor. The preliminary results provided by the present study indicate that, in principle, a complete hard X-ray and soft gamma-ray telescope imaging spectrometer system using the Lixiscope is feasible. However, much work remains to be done with respect to the optimization and improvement of the system for future flight applications.

Yin, L. I.↗

System description

The VAS, carried onboard the GOES 4 and 5 satellites, is a radiometer with 8 visible channel detectors and 6 thermal detectors that detect infrared radiation in 12 spectral bands. A filter wheel in front of the detector is used to achieve the spectral selection. The spatial resolution is 0.9 kilometer in the visible and 7 or 14 kilometers in the infrared depending on the detector used. Full Earth disk coverage is accomplished by spinning in the west to east direction at 100 rpm and by stepping a scan mirror from north to south. Additional VAS instrument characteristics are summarized. The VAS has three operating modes: the operational VISSR mode, the multispectral imaging (MSI) mode, and the dwell sounding (DS) mode. The operational VISSR mode is used by NOAA/NESS for its operational products, which include a visible picture and an 11 micrometer infrared (channel 8) picture at half hour intervals. The other modes are VAS unique. The MSI mode combines the operational VISSR capability (visible plus infrared window) with two additional spectral channels to provide half hourly full Earth disk imagery of atmospheric water vapor, temperature, and cloud distribution. The DS mode is used primarily for sounding to obtain the temperature and moisture profiles. In this mode, multiple spins on the same scan line in a given band are averaged to obtain the required signal to noise ratio for sounding.

Montgomery, H.↗

High-Resolution, Two-Wavelength Pyrometer

Modified two-color pyrometer measures temperatures of objects with high spatial resolution. Image focused on hole 0.002 in. (0.05 mm) in diameter in brass sheet near end of bundle, causing image to be distributed so fibers covered by defocused radiation from target. Pinhole ensures radiation from only small part of target scene reaches detector, thus providing required spatial resolution. By spreading radiation over bundle, pinhole ensures entire active area of detectors utilized. Produces signal as quiet as conventional instruments but with only 1/64 input radiation.

Bickler, Donald B.↗

High Resolution Imaging Spectrometer (HIRIS)

The High Resolution Imaging Spectrometer (HIRIS), related data system, orbit, and mission operations are described. The pushbroom instrument simultaneously images the terrestrial surface in 192 spectral bands from 0.4 to 2.5 microns. The swath width is 30 km and spatial resolution is 30 m. It is planned to be launched with the Earth Observing System aboard the Space Station Polar Platform in 1995. Array detectors allow concurrent integration of the signals at 192,000 detector elements.

Conley, Joseph M.↗

Microchannel Plate Imaging Detectors for the Ultraviolet

There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

Siegmund, O. H. W.↗

Thermal design and on-orbit performance of the ECOSTRESS instrument

The ECOSystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) instrument, launched on June 29, 2018, has completed nine months of operation in space. ECOSTRESS is a multispectral thermal infrared imaging radiometer and its primary mission is to investigate and understand how climate change affects water and carbon usage on Earth. The thermal control subsystem consists of a combination of active and passive components to maintain instrument components within the allowable flight temperature limits. Its focal plane detector is cooled to 65K by a pair of mechanical cryocoolers and a third mechanical cryocooler cools an intermediate cold shield to 130K. The heat dissipation generated by cryocoolers and electronics, is removed through non-planar cold plates and tube-on plate heat exchanger, which are cooled by a circulating fluid -EF module. The heat collected by the JEM-EF fluid is exchanged with a fluid loop that circulates through radiators located on the exterior of the Space Station. This paper provides an overview of the thermal and cryogenic system design, thermal analysis results and reviews the on-orbit thermal performance.

Romero, M.↗

Ultra-Low-Noise W-Band MMIC Detector Modules

A monolithic microwave integrated circuit (MMIC) receiver can be used as a building block for next-generation radio astronomy instruments that are scalable to hundreds or thousands of pixels. W-band (75-110 GHz) low-noise receivers are needed for radio astronomy interferometers and spectrometers, and can be used in missile radar and security imagers. These receivers need to be designed to be mass-producible to increase the sensitivity of the instrument. This innovation is a prototyped single-sideband MMIC receiver that has all the receiver front-end functionality in one small and planar module. The planar module is easy to assemble in volume and does not require tuning of individual receivers. This makes this design low-cost in large volumes.

Gaier, Todd C.↗

Detecting and characterizing special nuclear material for nuclear nonproliferation applications

Abstract There is an urgent need for new, better instrumentation and techniques for detecting and characterizing special nuclear material (SNM), i.e., highly enriched uranium and plutonium. The development of improved instruments and techniques requires experiments performed with the SNM itself, which is of limited availability. This paper describes the findings of experiments performed at the National Criticality Experiments Research Center conducted using new instruments and techniques on unclassified, kg-quantity SNM objects. These experiments, performed in the framework of the Department of Energy, National Nuclear Security Administration Consortium for Monitoring, Technology, and Verification, focused on detecting, characterizing, and localizing SNM samples with masses ranging from 3.3 to 13.8 kg, including plutonium and highly enriched uranium using prototype detectors and techniques. The work demonstrates SNM detection and characterization using recently-developed prototype detection systems. Specifically, we present new results in passive detection and imaging of plutonium and uranium objects using gamma-ray and dual particle (fast neutron and gamma-ray) imaging. We also present a new analysis of the delayed neutron emissions during active interrogation of uranium using a neutron generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

An infrared foreoptics adaptor for the Learjet Telescope

A foreoptics adapter has been built for the Learjet telescope which permits simultaneous viewing of the visible star field in the image plane and acquisition of astronomical data at infrared wavelengths (less than 1 micrometer). The device uses an adjustable dichroic beamsplitter to transmit visible wavelengths to an eyepiece (or television camera), and to reflect infrared wavelengths to a port where an infrared detector system can be mounted. The instrument is intended as a multiple user facility for the Learjet telescope. This report describes the adapter and its use.

Erickson, E. F.↗

Multiple object fiber optic spectroscopy

The Steward Observatory of the University of Arizona employs short optical fiber lengths to bring light from galaxy images at the 2.3 m telescope's focus to a line along a spectrograph slit, thereby obtaining simultaneous spectra of many objects of the field of view. After describing this instrument, attention is given to the development of an improved version through which efficiency gains will be obtained by remotely positioning the fibers under computer control and by correctly matching fiber outputs to the spectrograph optics. A CCD will replace the presently employed image tube and photographic plate detector system, in order to permit sky subtraction, yield increased dynamic range, and provide more accurate wavelength calibration due to the detector's fixed format.

Hill, J. M.↗

The Soft X-ray Telescope for Solar-A - Design evolution and lessons learned

The Japanese Solar-A satellite mission's Soft X-ray Telescope uses grazing-incidence optics, a CCD detector, and a pair of filter wheels for wavelength selection. A coaxially-mounted visible-light lens furnished sunspot and magnetic plage images, together with aspect information which aids in aligning the soft X-ray images with those from the satellite's Hard X-ray Telescope. Instrument electronics are microprocessor-based, and imbedded in a tightly integrated distributed system. Control software is divided between the instrument microprocessor and the spacecraft control computer.

Bruner, Marilyn E.↗

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Geostationary Lightning Mapper (GLM) for the GOES-R Series Next Generation Operational Environmental Satellite Constellation

The next generation Geostationary Operational Environmental Satellite (GOES-R) series with a planned launch in 2015 is a follow on to the existing GOES system currently operating over the Western Hemisphere. The system will aid in forecasting severe storms and tornado activity, and convective weather impacts on aviation safety and efficiency. The system provides products including lightning, cloud properties, rainfall rate, volcanic ash, air quality, hurricane intensity, and fire/hot spot characterization. Advancements over current GOES include a new capability for total lightning detection (cloud and cloud-to-ground flashes) from the Geostationary Lightning Mapper (GLM), and improved spectral, spatial, and temporal resolution for the 16-channel Advanced Baseline Imager (ABI). The Geostationary Lightning Mapper (GLM), an optical transient detector will map total (in-cloud and cloud-to-ground) lightning flashes continuously day and night with near-uniform spatial resolution of 8 km with a product refresh rate of less than 20 sec over the Americas and adjacent oceanic regions, from the west coast of Africa (GOES-E) to New Zealand (GOES-W) when the constellation is fully operational. In parallel with the instrument development, a GOES-R Risk Reduction Team and Algorithm Working Group Lightning Applications Team have begun to develop the higher level algorithms and applications using the GLM alone and decision aids incorporating information from the ABI, ground-based weather radar, and numerical models. Proxy total lightning data from the NASA Lightning Imaging Sensor on the Tropical Rainfall Measuring Mission (TRMM) satellite and regional lightning networks are being used to develop the pre-launch algorithms and applications, and also improve our knowledge of thunderstorm initiation and evolution. Real time total lightning mapping data are also being provided in an experimental mode to selected National Weather Service (NWS) national centers and forecast offices via the GOES-R Proving Ground to help improve our understanding of the application of these data in operational settings and facilitate early on-orbit user readiness for this new capability.

Goodman, Steven J.↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

An advanced workflow for single-particle imaging with the limited data at an X-ray free-electron laser

An improved analysis for single-particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from half of the detector and a small fraction of single hits. The general SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus-structure determination step. The presented processing pipeline allowed us to determine the 3D structure of bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An overview of the thematic mapper geometric correction system

Geometric accuracy specifications for LANDSAT 4 are reviewed and the processing concepts which form the basis of NASA's thematic mapper geometric correction system are summarized for both the flight and ground segments. The flight segment includes the thematic mapper instrument, attitude measurement devices, attitude control, and ephemeris processing. For geometric correction the ground segment uses mirror scan correction data, payload correction data, and control point information to determine where TM detector samples fall on output map projection systems. Then the raw imagery is reformatted and resampled to produce image samples on a selected output projection grid system.

Beyer, E. P.↗