Wise Detections of Known QSOS at Redshifts Greater Than Six

We present WISE All-Sky mid-infrared (IR) survey detections of 55 % (17/31) of the known QSOs at z greater than 6 from a range of surveys: the SDSS, the CFHT-LS, FIRST, Spitzer and UK1DSS. The WISE catalog thus provides a substantial increase in tiie quantity of IR data available for these sources: 17 are detected in the WISE Wl (3.4 micrometer) band, 16 in W2 (4.6 micrometers), 3 in W3 (12 micrometers) and 0 in W4 (22micrometers). This is particularly important with Spitzer in its warm-mission phase and no faint follow-up capability at wavelengths longwards of 5 micrometers until the launch of JWST. WISE thus provides a useful tool for understanding QSOs found in forthcoming large-area optical/IR sky surveys, using PanSTARRS, SkyMapper, VISTA, DES and LSST. The rest-UV properties of the WISE-detected and the WISE-non-detected samples differ: the detections have brighter i/z-band magnitudes and redder rest-UV colors. This suggests thai a more aggressive hunt for very-high-redshift QSOs, by combining WISE Wl and W2 data with red observed optical colors could be effective at least, for a subset of dusty candidate QSOs. Stacking the WISE images of the WISE-non-detected QSOs indicates that they are on average significantly fainter than the WISE-detccted examples, and are thus not narrowly missing detection in the WISE catalog. The WISE-catalog detection of three of our sample in the W3 band indicates that their mid-ID flux can be detected individually, although there is no stacked W3 detection of sources detected in Wl but not. W3. Stacking analyses of WISE data for large AGN samples will be a useful tool, and high-redshifl. QSOs of all types will be easy targets for JWST.

Galaxies: Evolution↗

AE (Acoustic Emission) for Flip-Chip CGA/FCBGA Defect Detection

C-mode scanning acoustic microscopy (C-SAM) is a nondestructive inspection technique that uses ultrasound to show the internal feature of a specimen. A very high or ultra-high-frequency ultrasound passes through a specimen to produce a visible acoustic microimage (AMI) of its inner features. As ultrasound travels into a specimen, the wave is absorbed, scattered or reflected. The response is highly sensitive to the elastic properties of the materials and is especially sensitive to air gaps. This specific characteristic makes AMI the preferred method for finding "air gaps" such as delamination, cracks, voids, and porosity. C-SAM analysis, which is a type of AMI, was widely used in the past for evaluation of plastic microelectronic circuits, especially for detecting delamination of direct die bonding. With the introduction of the flip-chip die attachment in a package; its use has been expanded to nondestructive characterization of the flip-chip solder bumps and underfill. Figure 1.1 compares visual and C-SAM inspection approaches for defect detection, especially for solder joint interconnections and hidden defects. C-SAM is specifically useful for package features like internal cracks and delamination. C-SAM not only allows for the visualization of the interior features, it has the ability to produce images on layer-by-layer basis. Visual inspection; however, is only superior to C-SAM for the exposed features including solder dewetting, microcracks, and contamination. Ideally, a combination of various inspection techniques - visual, optical and SEM microscopy, C-SAM, and X-ray - need to be performed in order to assure quality at part, package, and system levels. This reports presents evaluations performed on various advanced packages/assemblies, especially the flip-chip die version of ball grid array/column grid array (BGA/CGA) using C-SAM equipment. Both external and internal equipment was used for evaluation. The outside facility provided images of the key features that could be detected using the most advanced C-SAM equipment with a skilled operator. Investigation continued using in-house equipment with its limitations. For comparison, representative X-rays of the assemblies were also gathered to show key defect detection features of these non-destructive techniques. Key images gathered and compared are: Compared the images of 2D X-ray and C-SAM for a plastic LGA assembly showing features that could be detected by either NDE technique. For this specific case, X-ray was a clear winner. Evaluated flip-chip CGA and FCBGA assemblies with and without heat sink by C-SAM. Only the FCCGA package that had no heat sink could be fully analyzed for underfill and bump quality. Cross-sectional microscopy did not revealed peripheral delamination features detected by C-SAM. Analyzed a number of fine pitch PBGA assemblies by C-SAM. Even though the internal features of the package assemblies could be detected, C-SAM was unable to detect solder joint failure at either the package or board level. Twenty times touch ups by solder iron with 700degF tip temperature, each with about 5 second duration, did not induce defects to be detected by C-SAM images. Other techniques need to be considered to induce known defects for characterization. Given NASA's emphasis on the use of microelectronic packages and assemblies and quality assurance on workmanship defect detection, understanding key features of various inspection systems that detect defects in the early stages of package and assembly is critical to developing approaches that will minimize future failures. Additional specific, tailored non-destructive inspection approaches could enable low-risk insertion of these advanced electronic packages having hidden and fine features.

Ghaffarian, Reza↗

Modular Composite Damage Detection System (MCDDS)

The 2020 CIF funded Modular Composite Damage Detection System (MCDDS) aims to advance the technology of damage detection in composites in the areas of thin, flexible damage detection panel construction, encapsulation techniques in composite matrixes, innovative integration and interfacing techniques with flexible embedded sensory panels, repair methods of composite materials, and improved packaging of the MCDDS. Custom thin, flexible polyimide printed circuit boards (PCBs) were designed and procured for fabrication of test specimens. A custom interface PCB was designed and fabricated to monitor the newly developed damage detection test specimens. Test specimens were fabricated using the novel flexible circuitry that were either fully or partially encapsulated. The fully encapsulated specimens were used to demonstrate embedded damage detection concepts and the partially encapsulated specimens were used to demonstrate surface-mounted (laminate) damage detection concepts. The new composite damage detection test specimens were tested and evaluated to determine if the novel damage detection sensory panels could withstand low-cycle threshold fatigue loading per a modified version of American Society for Testing and Materials (ASTM) D 7264 for up to 50 cycles without void formation. The data for multiple sensory panels indicates that the newly fabricated sensory panels are robust and do indeed withstand three-point bend flexural loading for more than 50 cycles. Additionally, testing was performed to determine if damage could be detected in damage detection test specimens subjected to failure using a 3-point bend test per a modified version of ASTM D 7264. Again, multiple sensory panels (both fully and partially encapsulated) showed the ability to detect damage to specimens subjected to failure per a modified version of ASTM D 7264. Additionally, a novel concept for tracking and monitoring of cracking (and potentially delamination) in composites was designed and developed that utilizes painted-on conductors.

Christopher Forney↗

System and method for detecting cells or components thereof

A system and method for detecting a detectably labeled cell or component thereof in a sample comprising one or more cells or components thereof, at least one cell or component thereof of which is detectably labeled with at least two detectable labels. In one embodiment, the method comprises: (i) introducing the sample into one or more flow cells of a flow cytometer, (ii) irradiating the sample with one or more light sources that are absorbed by the at least two detectable labels, the absorption of which is to be detected, and (iii) detecting simultaneously the absorption of light by the at least two detectable labels on the detectably labeled cell or component thereof with an array of photomultiplier tubes, which are operably linked to two or more filters that selectively transmit detectable emissions from the at least two detectable labels.

47 OTHER INSTRUMENTATION↗

Using artificial intelligence to detect human errors in nuclear power plants: A case in operation and maintenance

Human error (HE) is an important concern in safety-critical systems such as nuclear power plants (NPPs). HE has played a role in many accidents and outage incidents in NPPs. Despite the increased automation in NPPs, HE remains unavoidable. Hence, the need for HE detection is as important as HE prevention efforts. In NPPs, HE is rather rare. Hence, anomaly detection, a widely used machine learning technique for detecting rare anomalous instances, can be repurposed to detect potential HE. In this study, we develop an unsupervised anomaly detection technique based on generative adversarial networks (GANs) to detect anomalies in manually collected surveillance data in NPPs. More specifically, our GAN is trained to detect mismatches between automatically recorded sensor data and manually collected surveillance data, and hence, identify anomalous instances that can be attributed to HE. We test our GAN on both a real-world dataset and an external dataset obtained from a testbed, and we benchmark our results against state-of-the-art unsupervised anomaly detection algorithms, including one-class support vector machine and isolation forest. Our results show that the proposed GAN provides improved anomaly detection performance. Our study is promising for the future development of artificial intelligence based HE detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

ALGORITHMS FOR OPTIMIZATION OF SYSYTEM PERFORMANCE IN LAYERED DETECTION SYSTEMS UNDER DETECTOR COORELATION

Almost all of the "architectures" for radiation detection systems in Department of Energy (DOE) and other USG programs rely on some version of layered detector deployment. Efficacy analyses of layered (or more generally extended) detection systems in many contexts often assume statistical independence among detection events and thus predict monotonically increasing system performance with the addition of detection layers. We show this to be a false conclusion for the ROC curves typical of most current technology gamma detectors, and more generally show that statistical independence is often an unwarranted assumption for systems in which there is ambiguity about the objects to be detected. In such systems, a model of correlation among detection events allows optimization of system algorithms for interpretation of detector signals. These algorithms are framed as optimal discriminant functions in joint signal space, and may be applied to gross counting or spectroscopic detector systems. We have shown how system algorithms derived from this model dramatically improve detection probabilities compared to the standard serial detection operating paradigm for these systems. These results would not surprise anyone who has confronted the problem of correlated errors (or failure rates) in the analogous contexts, but is seems to be largely underappreciated among those analyzing the radiation detection problem – independence is widely assumed and experimental studies typical fail to measure correlation. This situation, if not rectified, will lead to several unfortunate results. Including [1] overconfidence in system efficacy, [2] overinvestment in layers of similar technology, and [3] underinvestment in diversity among detection assets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Network Detection of Radiation Sources Using Localization-Based Approaches

Radiation source detection is a critical problem in homeland security-related applications. Deploying a network of detectors is expected to provide improved detection due to the combined, albeit dispersed, capture area of multiple detectors. Recently, localization-based detection algorithms provided performance gains beyond the simple “aggregated” area as a result of localization being enabled by the networked detectors. We introduce the following three localization-based detection approaches: 1) source-attractor radiation detection (SRD); 2) triangulation-based radiation source detection (TriRSD); and 3) the ratio of square distance-based radiation source detection (ROSD-RSD). We use canonical datasets from Domestic Nuclear Detection Office's intelligence radiation sensors systems tests to assess the performance of these methods. Extensive results demonstrate that SRD outperforms TriRSD and ROSD-RSD, and other existing detection algorithms based on the sequential probability ratio test and maximum likelihood estimation in terms of both false alarm and detection rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-shot gas detection with transformer paired neural networks in Mako collected longwave infrared hyperspectral imagery

To date, careful data treatment workflows and statistical detectors are used to perform hyperspectral image (HSI) detection of any gas contained in a spectral library, which is often expanded with physics models to incorporate different spectral characteristics. In general, surrounding evidence or known gas-release parameters are used to provide confidence in or confirm detection capability, respectively. This makes quantifying detection performance difficult as it is nearly impossible to develop an absolute ground truth for gas target pixel presence in collected HSI. Consequently, developing and comparing new detection methods, especially machine learning (ML)-based methods, is susceptible to subjectivity in derived detection map quality. Here, in this work, we demonstrate the first use of transformer-based paired neural networks (PNNs) for one-shot gas target detection for multiple gases while providing quantitative classification and detection metrics for their use on labeled data. Terabytes of training data are generated from a database of long-wave infrared HSI obtained from historical Mako sensor campaigns over Los Angeles. By incorporating labels, singular signature representations, and a model development pipeline, we can tune and select PNNs to detect multiple gas targets that are not seen in training on a quantitative basis. We additionally assess our test set detections using interpretability techniques widely employed with ML-based predictors, but less common with detection methods relying on learned latent spaces.

Hyperspectral imaging↗

SU-E-T-363: Error Detection Comparison of EPID and MLC Log File Based IMRT QA Systems

Purpose: In this study we will compare the ability of three QA methods (Delta4, MU-EPID, Dynalog QA) to detect specific errors. Methods: A Varian Novalis Tx with a HD120 MLC and aS1000 Electronic Portal Imaging Device (EPID) was used in our study. Multi-leaf collimator (MLC) errors, gantry angle and dose errors were introduced into 5 volumetric arc therapy (VMAT) plans. 3D dose distributions calculated with data from the EPID and Dynalog QA methods were compared with the planned dose distribution. The gamma passing percentages as well as percentage error of planning target volume (PTV) dose were used for passing determination. Baselines for gamma passing percentages and PTV dose were established by measuring the original plan 5 times consecutively. Standard passing thresholds as well as thresholds derived from receiver operator characteristic (ROC) analysis and 2 standard deviation (SD) criteria were used. Results: When applying the standard 95% pass rate at 3%/3mm gamma analysis 14, 21 and 8 of 30 errors were detected by the Delta4, MU-EPID and Dynalog QA methods respectively. Thresholds set at 2 SD from our base line measurements resulted in the detection of 18, 9 and 14 of 30 errors for the Delta4, MU-EPID and Dynalog QA methods respectively. When using D2 of the PTV as a metric the Dynalog QA detected 20 of 30 errors while the EPID method detected 14 of 30 errors. Using D98 of the PTV, Dynalog QA detected 13 of 30 while the EPID detected 3 of 30 errors. Conclusion: Although MU-EPID detected the most errors at the standard 95% cutoff it also produced the most false detections in the baseline data. The Dynalog QA was the most effective when the ROC adjusted passing threshold was used. D2 was more effective as a metric for detecting errors than D98.

60 APPLIED LIFE SCIENCES↗

A New Method for High Resolution Surface Change Detection: Data Collection and Validation of Measurements from UAS at the Nevada National Security Site, Nevada, USA

The use of uncrewed aerial systems (UAS) increases the opportunities for detecting surface changes in remote areas and in challenging terrain. Detecting surface topographic changes offers an important constraint for understanding earthquake damage, groundwater depletion, effects of mining, and other events. For these purposes, changes on the order of 5–10 cm are readily detected, but sometimes it is necessary to detect smaller changes. An example is the surface changes that result from underground explosions, which can be as small as 3 cm. Previous studies that described change detection methodologies were generally not aimed at detecting sub-5-cm changes. Additionally, studies focused on high-fidelity accuracy were either computationally modeled or did not fully provide the necessary examples to highlight the usability of these workflows. Detecting changes at this threshold may be critical in certain applications, such as global security research and monitoring for high-consequence natural hazards, including landslides. Here we provide a detailed description of the methodology we used to detect 2–3 cm changes in an important applied research setting—surface changes related to underground explosions. This methodology improves the accuracy of change detection data collection and analysis through the optimization of pre-field planning, surveying, flight operations, and post-processing the collected data, all of which are critical to obtaining the highest output data resolution possible. We applied this methodology to a field study location, collecting 1.4 Tb of images over the course of 30 flights, and location data for 239 ground control points (GCPs). We independently verified changes with orthoimagery, and found that structure-from-motion, software-reported root mean square errors (RMSEs) for both control and check points underestimated the actual error. We found that 3 cm changes are detectable with this methodology, thereby improving our knowledge of a rock’s response to underground explosions.

47 OTHER INSTRUMENTATION↗

Detection of Special Nuclear Material in Cargo using Continuous Neutron Interrogation and Tension Metastable Fluid Detectors

This paper presents results using a novel technique for detecting special nuclear materials (SNMs) based on interrogation with a continuous beam of 2.45 MeV neutrons coupled with high intrinsic efficiency tensioned metastable fluid detectors (TMFDs) operated in threshold rejection mode. While passive interrogation may be utilized for detecting SNMs such as {sup 239}Pu from their strong spontaneous fission neutron signatures, this is not so for highly-enriched uranium (HEU), the timely detection of which has been identified as a grand challenge by the U.S. Domestic Nuclear Detection Office (DNDO). Active (neutron and/or photon based) interrogation represents the only viable means for detecting HEU either shielded or unshielded within cargo containers. Active interrogation by neutrons or photons leads to unequivocal induced fission based signatures in terms of neutron energy and multiplicity. The main challenge under such circumstances pertains to being able to discern the relatively weak emission signatures from the intense interrogation pulses of neutrons and/or photons. Purdue University together with Sagamore Adams Laboratories, LLC (SAL) has been developing the TMFD sensor system that promises to provide high neutron detection efficiency for fast and thermal neutrons while remaining gamma-beta blind. As described in these references, the TMFD sensor system works on the principle of transient cavitation detection events (CDEs) caused by ionizing particles such as neutrons, alphas and fission fragments in fluids that have been placed in various states of tensioned (sub-zero) pressure states of fluid metastability. Such CDEs result in recordable signatures - both electronically as for conventional detectors, but also in the form of audio-visual signals. One key advantage that the TMFD holds over conventional neutron detectors is that it has proven gamma-beta 'blindness' and indeed, confirmed to possess GARRn = 1.0 to γ photons (tested in up to 10{sup 11} γ/s field from a 3 Ci {sup 137}Cs source). Such an enablement allows for detection without saturation from background, interrogating and fission created γ photons. Another key attribute is up to 60 % intrinsic fission spectrum neutron detection efficiency which, furthermore, is amenable to tailoring for threshold based rejection. That is, to be able to detect neutrons at or above a desired energy with good efficiency, while remaining relatively blind to neutrons below the chosen threshold. This research is the subject of our ongoing DNDO project at Purdue University, the results of which form the basis of this paper. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Prediction Metrics for Chemical Detection in Long-Wave Infrared Hyperspectral Imagery

A natural or anthropogenic process often generates a signature gas plume whose chemical constituents may be identified using hyperspectral imagery. A hyperspectral image is a pixel-indexed set of spectra where each spectrum reflects the chemical constituents of the plume, the atmosphere, the bounding background surface, and instrument noise. This study explored the relationship between gas absorbance and background emissivity across the long-wave infrared (LWIR) spectrum and how they affect relative gas detection sensitivity. The physics-based model for the observed radiance shows that high gas absorbance coupled with low background emissivity at a single wavenumber results in a stronger recorded radiance. Two sensitivity measures were developed to predict relative probability of detection using chemical absorbance and background emissivity: one focused on a single wavenumber while another accounted for the entire spectrum. The predictive abilities of these measures were compared to synthetic image analysis. This study simulated images with 499 distinct gases at each of 6 concentrations over 6 different background surfaces with the atmosphere and level of instrument noise held constant. The Whitened Matched Filter was used to define gas detection from an image spectrum. The estimate of a chemical’s probability of detection at a given concentration over a specific background was the proportion of detections in 500 trials. Of the 499 chemicals used in the images, 276 had estimated probabilities of detection below 0.2 across all backgrounds and concentrations; these chemicals were removed from the study. For 92.8 percent of the remaining chemicals, the single channel measure correctly predicted the background over which the chemical had the largest relative probability of detection. Further, the measure which accounted for information across all wavenumbers predicted the background over which the chemical had the largest relative probability of detection for 93.3 percent of the chemicals. These results suggest that the wavenumber with largest gas absorbance has the most influence over gas detection for this data. By furthering the in-silico experimentation with higher concentrations of gases not detectable in this experiment or by standardizing the gas absorbance spectra to unit vectors, these conclusions may be confirmed and generalized to more gases. This will help simplify image acquisition planning and the identification of unknowns in field collected images.

54 ENVIRONMENTAL SCIENCES↗

An Ensemble Approach to Computationally Efficient Radiological Anomaly Detection and Isotope Identification

Radiological source search is a challenging task involving detection and identification of weak sources in a constantly changing radiological background. As of now, many radiological source detection algorithms have been proposed; however, their computational complexity, and hence reliance on power intensive processing units inhibit low-power applications of radiological source search systems. In this work, we introduce the anomaly filter (AF) algorithm; a computationally light, yet effective time-series source detection algorithm based on exponential weighted moving average (EWMA) and Poisson deviance statistics. Then, we demonstrate that the proposed algorithm can be used in ensemble with other more computationally intensive source detection and identification algorithms to achieve both increased detection performance and reduced power consumption. The proposed AF algorithm and the ensemble algorithms were thoroughly benchmarked against several existing source detection and identification algorithms. The results show that the AF algorithm outperforms existing conventional source detection algorithms, and the ensemble approach improves the overall performance of existing source detection and isotope identification algorithms. Furthermore, the AF algorithm and the Non-negative Matrix Factorization approach based source identification (NMF-ID) algorithm were combined and implemented on a singleboard microcontroller and the power consumption was measured. This ensemble algorithm reduced the power consumption of the NMF-ID algorithm almost by a factor of 100, while improving the detection performance of the overall system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the line outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of image quality on calcification detection in digital mammography

Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.

61 RADIATION PROTECTION AND DOSIMETRY↗

DER Cybersecurity Detection and Response Suite

SAND2024-08475O The Distributed Energy Resource (DER) Cybersecurity Detection and Response Suite is a solution for distributed energy resource (DER) systems. The DER Security Orchestration, Automation, and Response (SOAR) solution that uses alerts from signature- and behavior-based Intrusion Detection Systems are intended to be deployed as bump-in-the-wire (BITW) devices in front of DER equipment. The fielded application would use multiple intrusion detection systems that report data to SOAR to respond to cyberattacks. The suite consists of two software components: • The proactive intrusion detection and mitigation system (PIDMS) secures grid-edge photovoltaic smart inverters and other equipment in distributed energy resource systems. It is a distributed BITW solution; cyber and physical data are automatically processed using network inspection tools and custom machine learning algorithms to detect abnormal events and correlate cyber-physical events. • The Security Orchestration, Automation, and Response for Distributed Energy Resources (SOAR4DER) application ingests data from several intrusion detection systems to quickly block attacks and revert DER systems to good states. Using a collection of intrusion detection system technologies on a BITW device, it incorporates physical and cyber data to detect abnormal and potential malicious behaviors. Multiple SOAR playbooks then use the intrusion detection system data streams to automatically defend the system. SOAR4DER system testing showed detection and response times under 30 seconds for all adversary reconnaissance, denial-of-service attacks, malicious Modbus commands, brute-force logins, and machine-in-the-middle attacks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, Jay↗

Utilizing Time Reversal Ultrasonics to Detect the Removal of Nuclear Materials from Geological Repositories (FY26 Mid-Year)

Detecting unauthorized nuclear material removal from storage environments, such as geological repositories, is a critical safeguards task essential to ensuring the integrity and non-diversion of nuclear materials. However, this process is fraught with significant technical challenges. Storage configurations often involve tightly packed nuclear material containers or obstructed environments, making detection of removal events exceedingly difficult. Optical surveillance cameras, which are commonly used for monitoring, suffer from substantial limitations, including restricted coverage, reliance on line-of-sight measurements, and vulnerability to environmental conditions in certain storage scenarios. As the global inventory of monitored nuclear materials increases and storage configurations become more complex— such as deep geological repositories, inaccessible storage vaults, and tightly packed containers—there is an urgent need for innovative detection technologies that can reliably identify unauthorized diversion events in these challenging environments. The challenge of detecting nuclear material removal in complex storage environments is both significant and urgent. Preventing unauthorized access, diversion, or tampering with nuclear materials is a cornerstone of global nuclear safeguards and nonproliferation efforts. Current detection methods are increasingly inadequate as storage configurations become more intricate and inaccessible. The limitations of existing technologies—such as their inability to detect changes behind obstructions, reliance on costly and labor-intensive processes, and vulnerability to environmental conditions—pose risks to the effectiveness of safeguards systems. Addressing this challenge is critical to maintaining international trust in nuclear safeguards frameworks and ensuring compliance with nonproliferation agreements. Our project builds on the proven concept of TRU technology that can address this unmet need. TRU has demonstrated exceptional spatial sensitivity and change detection capabilities in complex non-line-ofsight environments, making it uniquely suited for detecting unauthorized nuclear material removal in challenging storage configurations. Unlike optical methods, TRU is not limited by line-of-sight constraints or environmental conditions, enabling reliable detection of subtle alterations even behind obstructions. By leveraging TRU’s ability to identify removal or tampering events, we aim to develop a robust detection system that enhances safeguards in geological repositories, storage vaults, and other complex environments.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗