Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Proposed Classifications of Remote Operations for Nuclear Reactors Based on Physical and Cybersecurity Considerations

The incorporation of remote operations into reactor operations is a topic of high interest among advanced and small modular reactor (A/SMR) vendors, with some considering it essential to the success of their business models. However, remote operations are a concept novel to the nuclear industry. While various technical aspects of remote operations have been explored, a significant gap remains in understanding the security implications of integrating remote operations into reactor designs, particularly concerning the security requirements for remote-operations facilities and infrastructure. This report aims to address this gap by first defining classes of remote operation based on the extent of remote access to reactor control systems and grounded in the existing regulatory framework with compatible terminology. Secondly, the report outlines the physical and cybersecurity requirements applicable to remote-operations facilities and infrastructure at each defined class. These requirements are based on existing licensing frameworks provided by 10 Code of Federal Regulations (CFR) Part 50 and 10 CFR Part 52, as well as the upcoming A/SMR licensing framework in the proposed Part 53. The assessment focuses specifically on security regulations, such as 10 CFR Part 73, which includes provisions for both cybersecurity (§ 73.54) and physical security (§ 73.55). This report proposes five classes of remote reactor operations. Class 1 involves remote monitoring only, with no control over reactor systems. Class 2 allows for the remote issuance of allowlisted commands to the reactor facility. Class 3 extends control to non-safety-significant, non-safety-related, or not important to safety systems and equipment. Class 4 permits remote control of safety-significant systems. Finally, Class 5 allows remote control of safety-related systems. It is important to note that these classes were defined purely with functionality in mind, without considering the practicality or feasibility of implementation for each class under current or upcoming regulatory guidance. The intention behind this approach is to enable an assessment of which security requirements apply to each class, allowing readers to evaluate the implementation possibilities for their specific use cases. Following the definition of remote-operation classes, the report assesses the specific physical and cybersecurity requirements applicable to the remote-operations facility and infrastructure within each defined class. This includes defining the types and locations of operators that are possible at each class of operation and, based on operator type and location, as well as functionality within each class, outlining the physical and cybersecurity requirements. By detailing the security requirements by class, the report provides readers with the information needed to determine the type of security program they may need to implement for their desired concept of operation. The next contribution of this report was to assess the practicality of implementing each proposed class of remote operations based upon the security requirement assessment. In short, three of the five proposed remote-operation classes were found to possibly have a practical path forward to implementation under the U.S. regulatory framework. Class 1 remote operations are currently in use in the U.S. while Class 2 and 3 remote operations may be logistically possible to implement under the U.S. regulatory framework. The final two Classes, 4 and 5, would likely be logistically difficult, if not infeasible to implement within the current U.S. physical- and cybersecurity regulatory framework. Given the results of the feasibility assessment, an example architecture is proposed for both Class 2, remote allowlisted commands, and Class 3, remote control of non-safety systems as well as security implication assessments of each architecture. These example implementations are not meant to be prescriptive in terms of how Class 2 or Class 3 remote operations should be deployed; instead, they are intended to be informative to stakeholders on how Class 2 or Class 3 could potentially be applied in order to inform their system design. An example architecture for Class 1 remote monitoring was not provided as Class 1 in already in use in U.S. nuclear operations. Example architectures for Class 4 and Class 5 were not provided due to their assessment of being likely infeasible to implement. The final contribution is an assessment of the physical- and cybersecurity implications of introducing autonomous operations into an A/SMR. What was found was that the security implications can be separated into two cases. Autonomous operations supported by SSCs located only at the reactor site, and autonomous operations supported by SSCs outside of the reactor site. For the first case, the introduction of autonomous systems will likely not change the facility’s requirement to comply with existing cyber and physical security regulation

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Natural nanoparticle complexes at water-water interfaces

Aqueous two-phase systems (ATPSs) with multifunctional attributes have significant promise as biomimetic materials, but current approaches do not harness their full potential. Here, we show that ATPSs can be stabilized to form microcapsules by the interfacial assembly of chitin nanofibers (ChNF) and rod-like cellulose nanocrystals (CNC). The high structural stability of the ChNF/CNC complexes integrates permeability and transport across the membrane at the liquid/liquid interface. Driven by density and osmotic stress gradients, the microcapsules show switchable motility, including cyclic meniscus-climbing and subsurface transport. These observations demonstrate a self-regulating system with potential for cargo transfer, cell biomimicry, as well as ATPSs-based microreactors and microrobots.

Bioinspired materials↗

LA100 Equity Strategies. Chapter 2: Procedural Justice

The LA100 Equity Strategies project synthesizes community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. Grounded in the analysis of past and ongoing energy inequities and engagement with underserved communities, the project presents community-guided and community-tailored strategies that aim to operationalize recognition and procedural justice. This chapter focuses on procedural justice, examining priorities identified during the community engagement portion of the LA100 Equity Strategies project. This process, and our approach to partnering with community-based organizations (CBOs) and the communities they serve, was developed from the baseline analysis in Chapter 1, which centers on recognition justice, examining past and current inequities in LA. Recognition, procedural, and distributional justice are the three tenets of energy justice around which the LA100 Equity Strategies project is organized. Procedural justice prioritizes fair, equitable, and inclusive participation in the decision-making process. This tenet's practical application entails who is invited and able to participate, whose voices are considered as decisions are made, the co-development of procedures to inform this deliberative process, and who has access to formal measures of regulation and accountability. Engaging with Angelenos to examine the causes of inequities and identify impact areas and priorities that center community experiences, values, and goals represents a first step in developing energy equity strategies for the Los Angeles Department of Water and Power (LADWP) to achieve distributional justice - the just and equitable distribution of energy benefits and burdens in LA's energy transition. Equity, as community members insisted, is about making - and following through with - a commitment to prioritize historically underserved and overburdened communities. Community engagement is a principal method for operationalizing this commitment, guiding our analytic approach and potential equity strategies. Using procedural justice as an analytical tool, this chapter presents the LA100 Equity Strategies approach to community engagement from 2021 to 2023 and the results of this process in relation to community-identified barriers and burdens impacting procedural justice outcomes. We analyze the procedural elements of reaching the equity goals Angelenos set to inform future LADWP decision-making and program development.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BETO 2021 Peer Review - Bio-Insecticides from Thermochemical Biomass Conversion

This work is developing a sustainable and inexpensive bioinsecticide that leverages the inherent chemical functionality created from thermochemical biomass conversion. The impact of this project lies at the intersection of energy and agricultural sustainability. Thermochemical conversion of biomass to fuels remains an attractive pathway, and bioinsecticides, isolated from a fraction of upgraded bio-oils, are a high-valued coproduct that can increase biorefinery profitability. Existing insecticide products are facing significant pressure from regulators and consumers due to negative health and environmental impacts. Bioinsecticides, produced through the deconstruction of biomass, can offer a safer more environmentally benign alternative due to the chemical homology with biologically degraded lignin. To enable thermochemical coproduction of bioinsecticides insecticidal activity must be competitive with existing products, separations of the bioinsecticide must be technically viable, and the overall process economics must be improved. Using vacuum distillation, we have separated a bioinsecticide active ingredient that has similar activity to current commercial products, and technoeconomic modeling has shown it can be produced at market competitive prices. This work has established a bioinsecticide fraction that is ready for further, more resource intensive development by addressing early technical, economic, and toxicological risks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Stable High‐Voltage LiCoO 2 Operation by Using Synergetic Interfacial Modification Strategy

Abstract Structural and interfacial instability of the LiCoO 2 cathode under a voltage exceeding 4.5 V (vs Li/Li + ) severely hinders its practical applications for high‐energy‐density lithium batteries. Herein, a modified electrolyte with nitriles (suberonitrile or 1,3,6‐hexanetricarbonitrile) and fluoroethylene carbonate (FEC) coadditives is demonstrated to form an ultrathin and uniform interface layer on LiCoO 2 cathode under a synergetic effect. As such, LiCoO 2 /Li cells display excellent cyclability at a cutoff voltage of 4.6 V with a capacity retention over 72% after 300 cycles and 60% after 200 cycles at 30 and 55 °C, respectively, even achieving operation at a high current rate (10 C) upon 500 cycles as compared to the controls with fast‐falling capacity to zero. Furthermore, an adsorption‐coordination mechanism between nitriles and cobalt and synergetic effect of coadditives are explored by the alliance of spectroscopic analysis and theoretical calculations. The contributed lone‐pairs on the N 2p orbital of nitriles in coordination lowers the real oxidation state of Co 3+/4+ so that it decreases its catalysis on electrolytes, and the synergy from nitrile‐derived species regulates FEC to form an LiF‐containing electron‐insulated interface layer. This work shares a new insight to nitriles with the synergy of coadditives and paves a way to refine (ultra)high‐voltage LiCoO 2 cathode for high‐energy‐density energy storages.

Yang, Xuerui↗

Layer-by-Layer-Processed Organic Solar Cells with 18.02% Efficiency Enabled by Regulating the Aggregation of Bottom Polymers

The fabrication of organic solar cells (OSCs) by a layer-by-layer (LBL) method has attracted growing attention in recent years. As already known, the pre-aggregates of conjugated polymers in solution have a profound impact on their microstructure morphology in films. Herein, by simply controlling the solution temperature and annealing processes, the pre-aggregation behavior of D18 polymer in solution can be fine-tuned and the microstructure of D18 bottom layer is well manipulated. The optimized D18 bottom layer can effectively regulate L8-BO upper-layer-forming suitable networks for efficient charge transportation. In addition, a vertical phase separation with a special D/D:A/A structure (P-i-N-type component distribution) is also formed. As a result, compared to the 16.43% power conversion efficiency (PCE) of the bulk heterojunction devices, such control enables bilayer OSC devices based on the polymer D18 and L8-BO to deliver an enhanced PCE of 18.02% with simultaneously improved short-circuit current density, open-circuit voltage, and fill factor. Importantly, it is also demonstrated in these results that the LBL deposition process utilizing the pre-aggregation of polymer and its fiber-network-forming ability is a very promising approach to improve charge dynamics, suppress carrier recombination, and fabricate highly efficient OSCs.

14 SOLAR ENERGY↗

Anticancer effect of AZD2461 PARP inhibitor against colon cancer cells carrying wt or dysfunctional p53

Colon cancer is one of the most common cancers, currently treated with traditional chemotherapies or alternative therapies. However, these treatments are still not enough effective and induce several side effects, so that the search of new therapeutic strategies is needed. The use of Poly-(ADP-ribose)-polymerase (PARP) inhibitors, although originally approved against BRCA-1 or BRCA-2 mutated cancers, has been extended, particularly in combination with other treatments, to cure cancers that do not display defects in DNA repair signaling pathways. The role of p53 oncosuppressor in the regulating the outcome of PARP inhibitor treatment remains an open issue. In this study, we addressed this topic by using a well-tolerated PARP 1/2/3 inhibitor, namely AZD2461, against colon cancer cell lines with different p53 status. We found that AZD2461 reduced cell proliferation in wtp53 and p53−/− cancer cells by increasing ROS and DNA damage, while R273H mutant (mut) p53 counteracted these effects. Moreover, AZD2461 improved the reduction of cell proliferation by low dose radiation (IR) in wtp53 cancer cells, in which a down-regulation of BRCA-1 occurred. AZD2461 did not affect cell proliferation of mutp53 colon cancer cells also in combination with low dose radiation, suggesting that only wt p53 or p53 null colon cancer cells could benefit AZD2461 treatment.

60 APPLIED LIFE SCIENCES↗

Lithium–Sulfur Batteries Enabled by Fluorine-Free Electrolytes with a Compressed Solvation Structure

In this paper, a fluorine-free aromatic cosolvent strategy is presented to regulate electrolyte solvation chemistry in Li-S batteries with sulfurized polyacrylonitrile (SPAN) cathodes. Assisted by the Uni-ELF AI tool and experimental validation, toluene is identified as an optimal weakly solvating cosolvent. Its incorporation compresses the Li⁺ solvation sheath and induces an anion-dominated solvation structure, thereby enhancing interfacial ion transport and sulfur redox kinetics through controlled π-π interactions with polysulfides. Consequently, Li || Li symmetric cells exhibit stable cycling for over 1,000 cycles at a current density of 1 mA cm⁻². Meanwhile, Li-S cells employing high-loading SPAN cathodes retain more than 75% of their initial capacity after 250 cycles at -10 °C. Additionally, a practical pouch cell with high SPAN loading and a low electrolyte-to-SPAN ratio of 3 µL mg⁻¹ delivers an initial capacity of around 600 mAh gSPAN⁻¹, underscoring the potential of fluorine-free electrolytes for practical metal-sulfur batteries.

25 ENERGY STORAGE↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Test Report for DPP-1 Regulatory Compliance Testing. Volume 1 - Main Report

Consolidated Nuclear Security, LLC (CNS), the management and operating contractor for the Y-12 National Security Complex (Y-12) for the National Nuclear Security Administration (NNSA), is currently responsible for the regulatory testing of a new Type B fissile material shipping package called the Defense Programs Package (DPP)-1. The DPP-1 is a drum packaging with an inner liner and a removable lid. Both the drum body and the lid are filled with an impact-limiting, thermal-insulating material that protects the inner containment vessel (CV) during normal conditions of transport (NCT) and hypothetical accident conditions (HAC) as defined by 10 US code of Federal Regulations (CFR) 71. In fiscal year 2021, the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP), located at the National Transportation Research Center (NTRC), conducted Type B performance tests as prescribed in Title 10 Code of Federal Regulations Part 71 (10 CFR 71) on seven DPP-1 prototype units. This test report documents test unit (TU) preparation, pretest condition, conditioning of each TU, NCT and HAC testing, and posttest measurements and observations made of the damage resulting from these tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EV Charging Infrastructure Energization: An Overview of Approaches for Simplifying Processes and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure and electricity. Growth in electricity demand from EV charging, coupled with growth in other sectors like data centers and electrification of other sectors, is impacting electricity infrastructure and load service request processes after two decades of relatively flat electricity demand. While most electric vehicle charging occurs at home, enroute and depot charging for medium and heavy-duty vehicles, both using high-powered EV charging, are critical to meet electric vehicle operational needs. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have expressed distress that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions.

33 ADVANCED PROPULSION SYSTEMS↗

Black Start of Unbalanced Microgrids Harmonizing Single- and Three-Phase Grid-Forming Inverters: Preprint

As power systems are transforming with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has drawn attention. Using distributed grid-forming (GFM) assets located near critical loads, either three-phase or single-phase, to establish microgrid voltages in the absence of a bulk grid, a distribution system could obtain high system survivability. For swift and secure recovery of a critical load in a single-phase lateral, local single-phase GFM inverters can form a microgrid, and then it can be combined with a neighbouring grid with the inverters remaining in GFM mode for voltage and frequency regulation until the bulk grid comes online. It leads to dynamic interoperation of single-phase GFM inverters with three-phase ones in the black start process. This paper studies the novel approach with electromagnetic transient (EMT) simulations. To evaluate the potential and the technical challenges of the heterogeneous IBR-driven black start, three-phase and single-phase GFM inverter models are developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter (three-phase) and current magnitude limiter (single-phase). To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics emulating their inrush and startup behavior as well as network dynamics. Involvement of grid-following assets to facilitate the black-start process is also modeled. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, regardless of phases, a system can achieve extreme resilience. An inverter-driven black start of a heavily unbalanced 2-MVA distribution feeder using 1 three-phase and 3 single-phase GFM inverters is demonstrated. The simulation shows the heterogeneous system can maintain stability with the single-phase GFM dynamics coupled with the three-phase one.

grid-forming inverter↗

Thermal Regulation of CO 2 Activation Pathways via Interfacial Water Restructuring Enables Ampere-Level, Near-Unity CO Electrosynthesis

Electrochemical reduction of CO 2 to CO is a key step in carbon utilization technologies, yet maintaining high CO selectivity under elevated temperatures relevant to industrial membrane-electrode-assembly (MEA) electrolyzers remains challenging due to the competing hydrogen evolution reaction (HER). Additionally, the temperature dependence of CO selectivity on Cu-based catalysts has remained largely unexplored. Here, we demonstrate that incorporating atomic In or Sn into Cu fundamentally reshapes the selectivity of Cu catalysts at elevated temperatures. Dilute alloy catalysts, In 1 Cu and Sn 1 Cu, achieve >95% FE of CO over a broad current-density window (0.1−1.1 A cm −2 ) at 60 °C in MEA electrolyzers, far exceeding their performance at ambient temperature. In situ attenuated total reflection surface-enhanced infrared absorption spectroscopy suggests that elevating temperature depletes interfacial water activity, which favors a shift in CO 2 activation from a proton-coupled *COOH pathway toward an electron-driven *COO − -associated pathway, while also suppressing HER and CO hydrogenation. In contrast, benchmark CO-selective catalysts such as Ag exhibit minimal temperature-induced changes in CO production at 20−60 °C. These findings identify temperature as an unavoidable yet previously underutilized operating parameter in MEA electrolyzers for high-rate, selective CO production on Cubased catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CoolPINNs: A physics-informed neural network modeling of active cooling in vascular systems

Emerging technologies like hypersonic aircraft, space exploration vehicles, and batteries avail fluid circulation in embedded microvasculatures for efficient thermal regulation. Modeling is vital during the design and operational phases of these engineered systems. However, many challenges exist in developing a modeling framework. What is lacking is an accurate framework that (i) captures sharp jumps in the thermal flux across complex vasculature layouts, (ii) deals with oblique derivatives (involving tangential and normal components), (iii) handles nonlinearity because of radiative heat transfer, (iv) provides a high-speed forecast for real-time monitoring, and (v) facilitates robust inverse modeling. Here, this paper addresses these challenges by availing the power of physics-informed neural networks (PINNs). We develop a fast, reliable, and accurate Scientific Machine Learning (SciML) framework for vascular-based thermal regulation—called CoolPINNs: a PINNs-based modeling framework for active cooling. The proposed mesh-less framework elegantly overcomes all the mentioned challenges. The significance of the reported research is multi-fold. First, the framework is valuable for real-time monitoring of thermal regulatory systems because of rapid forecasting. Second, researchers can address complex thermoregulation designs since the approach is meshless. Finally, the framework facilitates systematic parameter identification and inverse modeling studies, perhaps the most significant utility of the current framework.

97 MATHEMATICS AND COMPUTING↗

Discovery of an autoinhibited conformation in mesotrypsin reveals a strategy for selective serine protease inhibition

Selective inhibition of the more than 100 S1 family serine proteases is a long-standing challenge due to their active site similarity. Mesotrypsin, implicated in cancer progression, exemplifies these difficulties; no current inhibitors achieve selectivity over other human trypsins. We found an unexpected autoinhibited conformation of mesotrypsin via x-ray crystallography, revealing a cryptic pocket adjacent to the active site. Using high-throughput virtual screening targeting this cryptic pocket, we identified a conformationally selective small-molecule inhibitor that stabilizes the inactive state of mesotrypsin. This inhibitor demonstrates selectivity for mesotrypsin over other trypsins. Our findings challenge the accepted view of digestive trypsins as constitutively active enzymes lacking potential for allosteric regulation. Furthermore, analyses of other structures suggest that dynamic sampling of closed states with analogous allosteric cryptic pockets appears widespread among S1 serine proteases. These observations point to a potentially generalizable strategy to achieve selective inhibition, offering broad implications for drug development targeting serine proteases in cancer and other diseases.

Coban, Matt↗