Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Analysis of the Production Cost for Various Grades of Biomass Thermal Treatment

Process flow sheets were developed for the thermal treatment of southern pine wood chips at four temperatures (150, 180, 230, and 270 degrees C) and two different scales (20 and 100 ton/hour). The larger capacity processes had as their primary heat source hot gas assumed to be available in quantity from an adjacent biorefinery. Mass and energy balances for these flow sheets were developed using Aspen Plus process simulation software. The hot gas demands in the larger processes, up to 1.9 million lb/hour, were of questionable feasibility because of the volume to be moved. This heat was of low utility because the torrefaction process, especially at higher temperatures, is a net heat producer if the organic byproduct gases are burned. A thermal treatment flow sheet using wood chips dried in the biorefinery to 10% moisture content (rather than 30% for green chips) with transfer of high temperature steam from the thermal treatment depot to the biorefinery was also examined. The equipment size information from all of these cases was used in several different equipment cost estimating methods to estimate the major equipment costs for each process. From these, factored estimates of other plant costs were determined, leading to estimates (± 30% accuracy) of total plant capital cost. The 20 ton/hour processes were close to 25 million dollars except for the 230 degrees C case using dried wood chips which was only 15 million dollars because of its small furnace. The larger processes ranged from 64-120 million dollars. From these capital costs and projections of several categories of operating costs, the processing cost of thermally treated pine chips was found to be $28-33 per ton depending on the degree of treatment and without any credits for steam generation. If the excess energy output of the two 20 ton/hr depot cases at 270 degrees C can be sold for $10 per million BTU, the net processing cost dropped to $13/ton product starting with green wood chips or only $3 per ton if using dried chips from the biorefinery. Including a 12% return on invested capital raised all of the operating cost results by about $20/ton.

09 BIOMASS FUELS↗

The Cost of Floating Offshore Wind Energy in California Between 2019 and 2032

California’s energy planning is centered around meeting the emissions reduction and renewable energy requirements of Senate Bill 350 by 2030. However, state power system planning is expected to eventually address California’s requirement to achieve 100% of total retail electricity sales from renewable energy and zero-carbon resources by 2045, as mandated by Senate Bill 100. To comply with these directives, California needs to investigate the further development of energy efficiency, storage, and a diverse range of renewable energy, zero-carbon emission, and transmission resources, including offshore wind. Wind resources off the coast of California have the potential to generate a significant portion of the state’s electric energy as it moves toward a zero-carbon economy and can help diversify its energy mix. Floating offshore wind technology, which is suitable for the deep waters along the California coast, is currently in a precommercial phase, with approximately 84 megawatts (MW) installed worldwide at the end of 2019. Globally there are over 7,000 MW in planning and permitting phases of development, with the first commercial-scale projects expected to be operational in 2024. This study provides site-specific cost and performance data for floating offshore wind to inform California’s long-term energy planning. The identification of new resources to meet California’s policy goals at least cost is part of the Integrated Resource Planning (IRP) process, which is coordinated by the California Public Utilities Commission (CPUC). In 2019–2020 IRP modeling, offshore wind was included for the first time as a candidate resource in some sensitivity cases (CPUC 2019). The data and information presented in this report can be used to update offshore wind inputs in future IRP cycles. The authors conducted a geospatial cost analysis over portions of the offshore wind resource area of California. The analyzed spatial domain includes sites with a mean wind speed of at least 7 meters per second and water depths between 40 meters (m) and 1,300 m. Costs and energy production vary across this analysis domain. We calculated these parameters on a grid layout with over 750 sites, with each site representing a 1,000-MW commercial offshore wind power plant. Levelized cost of energy (LCOE) was calculated at each site over the analysis domain. The resulting variation in LCOE across the analysis domain is illustrated through heat maps in this report. Five study areas were selected within the analysis domain where more detailed cost analysis was conducted and cost parameters, such as annual energy production, capital cost expenditures (CapEx), operational cost expenditures (OpEx), and net capacity factors are reported. These five study areas include Morro Bay, Diablo Canyon, Humboldt, Cape Mendocino and Del Norte.

17 WIND ENERGY↗

Electrical Infrastructure Cost Model for Marine Energy Systems

The National Renewable Energy Laboratory's Electrical Infrastructure Cost Model is an Excel-based tool designed to estimate the electrical infrastructure costs of marine energy components and subsystems. It incorporates data collected from offshore wind projects, utility projects, and other relevant sources to provide accurate and comprehensive cost projections. With its user-friendly interface, the model allows users to input various parameters related to the system array, electrical cables, and substations. By leveraging industry data, cost trends, and technological advancements, the model generates outputs that include system array sizing, electrical cable specifications and costs, substation specifications and costs, and total electrical infrastructure costs. One of the notable strengths of the model is its flexibility in covering multiple-orders-of-magnitude scaled systems, accommodating projects ranging from proof-of-concept or pilot-scale installations to large-scale offshore systems. By collecting data largely from offshore wind reports and utility projects, the model incorporates real-world conditions and accounts for industry-specific factors. It incorporates cost trends and sizing relationships to deliver cost estimations for electrical infrastructure components, such as electrical cables and substation equipment.

16 TIDAL AND WAVE POWER↗

Future Wind Energy Resources and Cost Uncertainties Across the United States

This dataset contains results estimating projections of change of annual capacity factors and levelized cost of energy for several turbine technologies in the 2024 Annual Technology Baseline (ATB). Projections of change are based on downscaled earth system model (ESM) data from Sup3rCC. There has been evidence of reductions in average wind speeds over land in North America since the 1980s, and several models project that average wind speeds will continue to decrease. Concurrently, the cost of wind energy systems in the United States has been decreasing since around 2010, a trend also projected to continue. There is considerable uncertainty in these future projections, with quantitative estimates of future wind resource and system costs varying widely. To study this, we run land-based wind energy models with a range of possible future system costs, turbine designs, and meteorological inputs from multiple downscaled earth system models over the contiguous United States to estimate critical system performance metrics such as annual energy production (AEP) and levelized cost of energy. Where multiple earth system models agree, changes in mean AEP from the time period 2000-2019 to 2040-2059 can be as high as +10% in South Texas or as low as -20% in Iowa. Several additional states in the Midwest that currently have considerable wind generation capacity show the possibility of substantial decreases in AEP by mid-century. Larger turbines and moderate reductions in system costs can offset even the largest projected decreases in wind resource, but much uncertainty remains in the extent to which wind resources will actually change into the future and to what extent wind energy systems can drive down future costs. An analysis of variance shows, in several states in the Midwest, the uncertainty in future wind resource can be almost as important for future changes in the cost of wind energy as the uncertainty in future system costs.

17 WIND ENERGY↗

Much Lower Launch Costs Make Resupply Cheaper than Recycling for Space Life Support

The development of commercial launch vehicles by SpaceX has greatly reduced the cost of launching mass to Low Earth Orbit (LEO). Reusable launch vehicles may further reduce the launch cost per kilogram. The new low launch cost makes open loop life support much cheaper than before. Open loop systems resupply water and oxygen in tanks for crew use and provide disposable lithium hydroxide (LiOH) in canisters to remove carbon dioxide. Short human space missions such as Apollo and shuttle have used open loop life support, but the long duration International Space Station (ISS) recycles water and oxygen and removes carbon dioxide with a regenerative molecular sieve. These ISS regenerative and recycling life support systems have significantly reduced the total launch mass needed for life support. But, since the development cost of recycling systems is much higher than the cost of tanks and canisters, the relative cost savings have been much less than the launch mass savings. The Life Cycle Cost (LCC) includes development, launch, and operations. If another space station was built in LEO, resupply life support would be much cheaper than the current recycling systems. The mission most favorable to recycling would be a long term lunar base, since the resupply mass would be large, the proximity to Earth would reduce the need for recycling reliability and spares, and the launch cost would be much higher than for LEO due to the need for lunar transit and descent propulsion systems. For a ten-year lunar base, the new low launch costs make resupply cheaper than recycling systems similar to ISS life support.

launch costs↗

A Higher Fidelity Cost Analysis of Wind and Uranium from Seawater Acquisition symbiotic Infrastructure

The vastness of the worlds oceans makes the low concentration of naturally existing uranium, 3.3 ppb, appealing as a recoverable natural resource. Although ample uranium is available currently through conventional means, uranium from seawater is a widely studied topic due to the long term security it can assure the nuclear fuel cycle. It is important to mention that seawater uranium is not meant to act as a direct competitor to terrestrial uranium, but instead create a cost ceiling that provides economic stability and potential savings. Additionally, seawater uranium could circumvent some of the environmental impacts associated with recovery of any land based resource. The system currently studied by a nation-wide consortium of national lab and university partners involves the passive recovery of uranium using polymer based adsorbents. High Density Polyethylene fibers undergo a radiation induced graft co-polymerization process involving amidoxime, to attract uranium, and a polar co-monomer to increase hydrophilicity. After further chemical conditioning adsorbent fibers are braided into 60 meter strands for marine deployment. Braids are moored to the ocean floor for the duration of their soaking campaign. After sufficient seawater exposure they are winched up so the adsorbed uranium may be eluted off the braids. This deployment and elution process is repeated multiple times before the adsorbent's ultimate disposal, where its lifetime is dictated by the degradation it suffers with each re-cycle. Previous economic analyses have identified the adsorbent production and mooring as the most expensive components of the recovery process. Therefore, a later publication by Picard et al. proposed an alternative deployment method in an effort to reduce seawater uranium production cost. The Wind and Uranium from Seawater Acquisition symbiotic Infrastructure (WUSABI) couples uranium recovery with off shore wind to reduce mooring capital cost. The uranium harvesting structure attached to the underwater base of the wind turbine supports elution tanks and an adsorbent pulley system. This allows for a nearly autonomous mooring and elution procedure as adsorbent is in constant motion, reaching the elution tanks at the end of its soaking campaign. Although the original publication did include a short economic section, further analysis was carried out to provide a higher fidelity production cost estimate for uranium recovered by this system. Sufficient detail was provided regarding the capital and operating costs of the novel uranium harvesting units. The adsorbent production and uranium elution and purification steps however were estimated by simpler methods, for example applying a previously reported cost for producing a unit mass of adsorbent. This methodology, although satisfactory for the zeroth-order approximation desired in the original publication, overlooks many of the complexities and feedbacks embedded in the full cost model, which are necessary to provide a more accurate estimate. Perhaps more importantly, given the constant updates regarding adsorbent synthesis and performance this value quickly become outdated. Syncing an improved estimate for the WUSABI harvesting units with the existing economic analysis for adsorbent production and elution, which evolves in tandem with the technology, provides a more robust production cost estimate that will remain current over time. In addition to the updates and higher level of detail provided in this independent analysis, consistency in methodology allows for accurate comparison of uranium production costs across recovery methods. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

The economic and environmental costs and benefits of the renewable fuel standard

Abstract Mandates, like the renewable fuel standard (RFS), for biofuels from corn and cellulosic feedstocks, impact the environment in multiple ways by affecting land use, nitrogen (N)-leakage, and greenhouse gas (GHG) emissions. We analyze the differing trade-offs these different types of biofuels offer among these multi-dimensional environmental effects and convert them to a monetized value of environmental damages (or benefits) that can be compared with the economic costs of extending these mandates over the 2016–2030 period. The discounted values of cumulative net benefits (or costs) are then compared to those with a counterfactual level of biofuels that would have been produced in the absence of the RFS over this period. We find that maintaining the corn ethanol mandate at 56 billion l till 2030 will lead to a discounted cumulative value of an economic cost of $199 billion over the 2016–2030 period compared to the counterfactual scenario; this includes $109 billion of economic costs and $85 billion of net monetized environmental damages. The additional implementation of a cellulosic biofuel mandate for 60 billion l by 2030 will increase this economic cost by $69 billion which will be partly offset by the net discounted monetized value of environmental benefits of $20 billion, resulting in a net cost of $49 billion over the 2016–2030 period. We explore the sensitivity of these net (economic and environmental) costs to alternative values of the social costs of carbon and nitrogen and other technological and market parameters. We find that, unlike corn ethanol, cellulosic biofuels can result in positive net benefits if the monetary benefits of GHG mitigation are valued high and those of N-damages are not very high.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen Production Cost with Alkaline Electrolysis

Rigorous stakeholder-vetted techno-economic analysis was performed to assess the cost of hydrogen (H 2 ) produced using state-of-the-art Liquid Alkaline (LA) electrolysis. Projected high-volume, untaxed levelized cost of hydrogen (LCOH) range from 2020US $\$ 1.84$ to $\$ 2.88$/kg-H 2 depending on technology year, process design, and electrolyzer project scale, assuming an electricity price of $\$ 0.03$/kWh. The total installed capital cost for a LA electrolysis plant was estimated from bottom-up stack and installed cost models that account for purchased equipment, installation costs, site preparation, and general overhead costs. For this study, the LA electrolysis plant is assumed to be a stick-built, greenfield project developed by an EPC firm with electrolysis stacks purchased directly from an electrolysis stack manufacturer. The price of the electrolysis stacks is based on a bottom-up cost assessment with business markup for the electrolysis company fabricator. Methods from the Hydrogen Analysis (H 2 A) production model, a peer-reviewed national laboratory-developed discounted cash flow model, were used to calculate the LCOH production in 2020$/kg-H 2 . The baseline electricity price case ($\$ 0.03$/kWh) corresponds to average wholesale electricity prices currently possible in U.S. markets with plentiful wind. Similar low-cost electricity pricing is possible from solar Power Purchase Agreements (PPA) although these prices are typically limited by renewable energy capacity factors.

08 HYDROGEN↗

Cost‐Responsive Optimization of Nickel Nanoparticle Synthesis

Abstract Early‐stage cost evaluation during catalyst development holds the potential to accelerate the commercialization and deployment of advanced catalytic materials for sustainable chemical processes. The modeling and assessment of manufacturing costs as early as the laboratory synthesis scale, for example, focusing on materials costs and synthesis performance metrics, can support the development of an experimental–economic feedback loop that enables rapid insight into cost drivers associated with catalyst synthesis and highlights areas that require focused research and development effort. Ultimately, this feedback loop supports the realization of an economic understanding of the overall synthetic process and highlights opportunities to reduce costs, serving as the foundation for the scale‐up of catalyst manufacturing. Herein, a case study is presented utilizing CatCost, a free and publicly available estimation tool for the evaluation of catalyst manufacturing costs, to perform a cost‐responsive optimization of the synthesis of nickel nanoparticles (Ni NPs). It is demonstrated that reagent substitutions with more cost‐effective analogs, coupled with stoichiometric optimization, afford a 58% reduction in raw materials cost without changing the product yield or properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The differential impact of low-carbon technologies on climate change mitigation cost under a range of socioeconomic and climate policy scenarios.

This paper considers the effect of several key parameters of low carbon energy technologies on the cost of abatement. A methodology for determining the minimum level of performance required for a parameter to have a statistically significant impact on CO2 abatement cost is developed and used to evaluate the impact of eight key parameters of low carbon energy supply technologies on the cost of CO2 abatement. The capital cost of nuclear technology is found to have the greatest impact of the parameters studied. The cost of biomass and CCS technologies also have impacts, while their efficiencies have little, if any. Sensitivity analysis of the results with respect to population, GDP, and CO2 emission constraint show that the minimum performance level and impact of nuclear technologies is consistent across the socioeconomic scenarios studied, while the other technology parameters show different performance under higher population, lower GDP scenarios. Solar technology was found to have a small impact, and then only at very low costs. These results indicate that the cost of nuclear is the single most important driver of abatement cost, and that trading efficiency for cost may make biomass and CCS technologies more competitive.

climate change↗

Probabilistic cost estimation methods for treatment of water extracted during CO 2 storage and EOR

Extraction and treatment of in situ water can minimize risk for large-scale CO 2 injection in saline aquifers during carbon capture, utilization, and storage (CCUS), and for enhanced oil recovery (EOR). Additionally, treatment and reuse of oil and gas produced waters for hydraulic fracturing will conserve scarce fresh-water resources. Each treatment step, including transportation and waste disposal, generates economic and engineering challenges and risks; these steps should be factored into a comprehensive assessment. We expand the water treatment model (WTM) coupled within the sequestration system model CO 2 -PENS and use chemistry data from seawater and proposed injection sites in Wyoming, to demonstrate the relative importance of different water types on costs, including little-studied effects of organic pretreatment and transportation. We compare the WTM with an engineering water treatment model, utilizing energy costs and transportation costs. Specific energy costs for treatment of Madison Formation brackish and saline base cases and for seawater compared closely between the two models, with moderate differences for scenarios incorporating energy recovery. Transportation costs corresponded for all but low flow scenarios (<5000 m 3 /d). Some processes that have high costs (e.g., truck transportation) do not contribute the most variance to overall costs. Other factors, including feed-water temperature and water storage costs, are more significant contributors to variance. These results imply that the WTM can provide good estimates of treatment and related process costs (AACEI equivalent level 5, concept screening, or level 4, study or feasibility), and the complex relationships between processes when extracted waters are evaluated for use during CCUS and EOR site development.

20 FOSSIL-FUELED POWER PLANTS↗

Refueling-station costs for metal hydride storage tanks on board hydrogen fuel cell vehicles

Refueling costs account for much of the fuel cost for light-duty hydrogen fuel-cell electric vehicles. We estimate cost savings for hydrogen dispensing if metal hydride (MH) storage tanks are used on board instead of 700-bar tanks. Here, we consider a low-temperature, low-enthalpy scenario and a high-temperature, high-enthalpy scenario to bracket the design space. The refueling costs are insensitive to most uncertainties. Uncertainties associated with the cooling duty, coolant pump pressure, heat exchanger (HX) fan, and HX operating time have little effect on cost. The largest sensitivities are to tank pressure and station labor. The cost of a full-service attendant, if the refueling interconnect were to prevent self-service, is the single largest cost uncertainty. MH scenarios achieve 0.71–0.75/kg-H 2 savings by reducing compressor costs without incurring the cryogenics costs associated with cold-storage alternatives. Practical refueling station considerations are likely to affect the choice of the MH and tank design.

08 HYDROGEN↗

Cost Analysis of Complex Radiation Therapy for Patients With Head and Neck Cancer

Purpose: This cost analysis aimed to prospectively assess differences in costs between TomoTherapy and volumetric modulated arc therapy (VMAT) in patients with head and neck cancer. Methods and Materials: Economic data were gathered from a multicenter study. However, randomization was not possible due to the availability of equipment. Costs were calculated using the microcosting technique from the hospital's perspective (in 2013 euros), and the time horizon was radiation therapy. Only resources that entered the hospital production process and which were likely to vary between the strategies being compared were considered. Acute adverse events observed within the time horizon were also assessed. Results: The cost analysis was based on a total of 173 patient treatments given between 2010 and 2012 in 14 French cancer centers: 73 patients were treated with TomoTherapy, 92 with VMAT RapidArc, and 8 with VMAT SmartArc. Estimated costs of SmartArc were removed from the comparison due to the small sample size. The mean ± SD cost per patient of the treatment planning phase was €314 (±€214) for TomoTherapy and €511 (±€590) for RapidArc. Mean costs ± SD per patient of irradiation reached €3144 (±€565) for TomoTherapy and €1350 (±€299) for RapidArc. The most sensitive parameter of irradiation was the annual operating time of accelerators. Ninety-five percent confidence intervals for the mean costs of irradiation were €3016 to €3272 for TomoTherapy and €1281 to €1408 for RapidArc. The number of acute adverse events during radiation therapy was not significantly different between strategies. Conclusions: TomoTherapy appeared to be more expensive than RapidArc mainly due to the higher price of the accelerator, the higher costs of maintenance, and the longer duration of treatment sessions. Because strategies were not significantly different in clinical effect, RapidArc appeared to be the strategy to be recommended at this stage of knowledge.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost estimates of production scale semitransparent organic photovoltaic modules for building integrated photovoltaics

Building integrated photovoltaics (BIPVs) are attached to commercial and residential structures to enable solar energy harvesting. While conventional Si photovoltaics (PVs) are dominant in the current market, second and third generation thin film solar cells based on amorphous Si, CdTe, CIGS, perovskites or organic photovoltaics (OPVs) are often considered as an alternative for BIPV applications since they may offer reduced costs compared to Si PVs. Indeed, recent advances in performance suggest that lightweight, flexible and visibly transparent OPVs can potentially be integrated into windows or other applications to which Si PVs are less well suited. Here, we estimate the cost of high efficiency, semitransparent OPVs (ST-OPVs) based on solution processing in a roll-to-roll (R2R) manufacturing line. Assuming modules with 10% power conversion efficiency (PCE), a 70% geometric fill factor (GFF), and 95% inverter efficiency, we anticipate a %1.6 per Wp module manufacturing cost that includes the cost of the microinverter to condition the OPV dc output to be compatible with the ac line voltage of the building. The materials and inverter cost comprise ~90% of the total module cost. Hence, with simplified material synthesis and a lower inverter cost, including marginally improved PCE and GFF, we expect the cost can be as low as $0.47 per Wp. Here, while the module costs ~60% of the average (uninstalled) double-pane window, we expect the payback period can be as short as 2 to 6 years, suggesting that OPVs can be an economic and attractive candidate for BIPV applications.

14 SOLAR ENERGY↗

Optimal strategies for a cost-effective and reliable 100% renewable electric grid

This paper explores cost-optimal pathways to 100% renewable power systems for the U.S. building stock. We show that long-duration misalignments of supply and demand, spanning from multi-day to seasonal timescales, present a dominant challenge that must be addressed to meet real-time 100% renewable targets. While long-duration misalignments can be addressed through energy storage, we show that alternative and readily available solutions that are more cost-effective should be considered first. Through a techno-economic analysis, we identify cost-optimal, region-dependent, supply-side, and demand-side strategies that reduce, and in some U.S. regions eliminate, the otherwise substantial capacities and associated costs of long-duration energy storage. Investigated supply-side strategies include optimal mixes of renewable portfolios and oversized generation capacities. Considered demand-side strategies include building load flexibility and building energy efficiency investments. Our results reveal that building energy efficiency measures can reduce long-duration storage requirements at minimum total investment costs. In addition, oversizing and diversifying renewable generation can play a critical role in reducing storage requirements, remaining cost effective even when accounting for curtailed generation. We identify regionally dependent storage cost targets and show that for emerging long-duration energy storage innovations to achieve broad adoption, their costs will need to compete with the decreasing cost of renewables. The findings of this research are particularly important given that most long-duration storage technologies are currently either uneconomical, geologically constrained, or still underdeveloped.

100% renewable↗

Least-cost targets and avoided fossil fuel capacity in India’s pursuit of renewable energy

India has set aggressive targets to install more than 400 GW of wind and solar electricity generation by 2030, with more than two-thirds of that capacity coming from solar. This paper examines the electricity and carbon mitigation costs to reliably operate India’s grid in 2030 for a variety of wind and solar targets (200 GW to 600 GW) and the most promising options for reducing these costs. We find that systems where solar photovoltaic comprises only 25 to 50% of the total renewable target have the lowest carbon mitigation costs in most scenarios. This result invites a reexamination of India’s proposed solar-majority targets. We also find that, compared to other regions and contrary to prevailing assumptions, meeting high renewable targets will avoid building very few new fossil fuel (coal and natural gas) power plants because of India’s specific weather patterns and need to meet peak electricity demand. However, building 600 GW of renewable capacity, with the majority being wind plants, reduces how often fossil fuel power plants run, and this amount of capacity can hold India’s 2030 emissions below 2018 levels for less than the social cost of carbon. With likely wind and solar cost declines and increases in coal energy costs, balanced or wind-majority high renewable energy systems (600 GW or ≈ 45% share by energy) could result in electricity costs similar to a fossil fuel-dominated system. As an alternative strategy for meeting peak electricity demand, battery storage can avert the need for new fossil fuel capacity but is cost effective only at low capital costs (≈ USD 150 per kWh).

14 SOLAR ENERGY↗

Characteristics of a cost-effective blood test for colorectal cancer screening

Background: Blood-based biomarker tests can potentially change the landscape of colorectal cancer (CRC) screening. We characterize the conditions under which blood test screening would be as effective and cost-effective as annual fecal immunochemical testing or decennial colonoscopy. Methods: We used the 3 Cancer Information and Surveillance Modeling Network–Colon models to compare scenarios of no screening, annual fecal immunochemical testing, decennial colonoscopy, and a blood test meeting Centers for Medicare & Medicaid (CMS) coverage criteria (74% CRC sensitivity and 90% specificity). We varied the sensitivity to detect CRC (74%-92%), advanced adenomas (10%-50%), screening interval (1-3 years), and test cost ($25-$500). Primary outcomes included quality-adjusted life-years (QALY) gained from screening and costs for a US average-risk cohort of individuals aged 45 years. Results: Annual fecal immunochemical testing yielded 125-163 QALY gained per 1000 at a cost of 3811-5384 dollars per person, whereas colonoscopy yielded 132-177 QALY gained at a cost of 5375-7031 dollars per person. A blood test with 92% CRC sensitivity and 50% advanced adenoma sensitivity yielded 117-162 QALY gained if used every 3 years and 133-173 QALY gained if used every year but would not be cost-effective if priced above $$125 per test. If used every 3 years, a $500 blood test only meeting CMS coverage criteria yielded 83-116 QALY gained at a cost of $8559-$9413 per person. Conclusion: Blood tests that only meet CMS coverage requirements should not be recommended to patients who would otherwise undergo screening by colonoscopy or fecal immunochemical testing because of lower benefit. Blood tests need higher advanced adenoma sensitivity (above 40%) and lower costs (below $125) to be cost-effective.

60 APPLIED LIFE SCIENCES↗

Utility-Scale Lithium-Ion Storage Cost Projections for Use in Capacity Expansion Models

This work presents U.S. utility-scale battery storage cost projections for use in capacity expansion models. We create battery cost projections based on a survey of literature cost projections of battery packs and balance of system costs, with a focus on lithium-ion batteries. Low, mid, and high cost trajectories are created for the overnight capital costs and the operating and maintenance costs. We then demonstrate the impact of these cost projections in the Regional Energy Deployment System (ReEDS) capacity expansion model. We find that under reference scenario conditions, lower battery costs can lead to increased penetration of variable renewable energy, with solar photovoltaics (PV) seeing the largest increase. We also find that additional storage can reduce renewable energy curtailment, although that comes at the expense of additional storage losses.

25 ENERGY STORAGE↗