Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control of Distributed Energy Resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A Novel Multiagent Resource Sharing Algorithm for Control of Advanced Energy Systems

This paper implements a novel resource sharing control strategy on a fuel cell–gas turbine hybrid power system at the National Energy Technology Laboratory’s Hybrid Performance Facility (Hyper). In a fuel cell–gas turbine hybrid power system, the simultaneous interaction of the gas turbine and the fuel cell creates a tightly coupled environment characterized by conflicting dynamics. In this paper, a model-free control approach is applied to solve the tightly coupled control problem posed by this challenging environment. Specifically, this control problem is presented as a resource sharing problem that can be solved using a resource sharing algorithm that is defined based on the distribution construction concept. This algorithm creates computational agents and solves the problem through the distribution and redistribution of shared resources defined as blocks. Furthermore, two agents were created; the first agent (agent 1) controls the gas turbine speed by adjusting the electric load, and the second agent (agent 2) controls the cathode mass flow through the fuel cell using the cold-air bypass valve. A parametric study was performed over the course of 15 experimental tests for both agents 1 and 2 through an evaluation of the responses based on setpoint changes. The algorithm was shown to have behavior comparable to a previously implemented multi-input multioutput state-space controller, which was designed through a model-based control approach. The resource sharing algorithm was able to find stable performance during run-time operations without any prior system knowledge identification on the power plant and without creating models used in traditional control strategies.

25 ENERGY STORAGE↗

Approximate Dynamic Programming With Enhanced Off-Policy Learning for Coordinating Distributed Energy Resources

Herein this paper proposes an innovative approximate dynamic programming (ADP) method for distributed energy resource coordination with the loss of life of battery energy storage system (BESS) explicitly modeled. The dispatch policy is designed to account for both calendrical and cyclical aging effects on BESS, explicitly modeling the impacts of ambient temperature on BESS lifespan. The proposed ADP employs an adaptive critic method and enhanced off-policy deterministic policy gradient (DPG) strategy, addressing the limitations of the on-policy gradient-based ADP approaches, including inadequate exploration, low data usage, and computational complexity. In particular, a customized policy is proposed to guide the algorithm to explore some promising decisions and thereby improve exploration capability and learning efficiency compared to conventional DPG-based learning approaches, which may struggle to find a global optimum due to random noisy action-based exploration or require expert demonstration with extra effort. The proposed method is illustrated using the IEEE 123-node system and compared with the existing ADP methods to prove solution accuracy and demonstrate the effects of incorporating degradation models into control design. Case studies showed that the proposed ADP effectively coordinates DERs with a 10 times smaller optimization gap compared to existing methods, and the incorporation of the BESS life loss model ensures the expected lifespan and results in significant cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

Experimental-based mechanistic study and optimization of hydrothermal liquefaction of anaerobic digestates

Valorization of agricultural and food waste digestates is crucial for sustainable waste management to reduce environmental impacts and improve the economics of commercial farms. Hydrothermal liquefaction (HTL) of anaerobic digestates was evaluated to recover resources by converting them into carbon-dense biocrude oil and a nutrient-rich HTL aqueous phase (HTL-AP) coproduct. The effects of HTL temperature (280–360 °C), reaction time (10–50 min), feedstock pH (2.5–8.5), digestate salt content (1–5 wt%), and digestate cellulose-to-lignin ratio (0.2–1.8) on energy and nutrient recovery were systematically investigated in a set of well-designed experiments following a half-fractional central composite protocol. Response surface analysis combined with HTL product characterization and comparative literature study produced a comprehensive reaction pathway for HTL of anaerobic digestates. Moreover, this analysis revealed the importance of acidic feedstocks (pH 3.00–5.53), high reaction temperatures (337–360 °C), and reaction times <45 or 45–50 min for digestates with Cel/Lig >1 or <1, for maximizing the energy recovered in biocrude (high carbon yield and low heteroatom content) and the amounts of P, NH 3 –N, and Mg distributed in the HTL-AP. Acidic conditions catalyzed biocrude production, inhibited the Maillard reaction (lowering the nitrogen content in biocrude), and partitioned nutrients into the HTL-AP. Higher reaction temperatures coupled with longer reaction times activated hydro-denitrogenation and deoxygenation reactions to improve biocrude quality. Finally, this work provides not only validated methods to achieve targeted resource recovery for specific feedstock compositions using HTL, but also a comprehensive mechanistic understanding of the HTL of biomass waste for controlling target product characteristics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cyber Physical Subsystems under Adverse Conditions

The United States power grid is built upon complex cyber-physical systems (CPS), including many distributed energy resources (DERs) and microgrid structures. Due to cross-disciplinary domains that govern the interplay between cyber and physical technologies that sustain DERs, it is difficult to confidently predict how these systems will react under adverse conditions such as faults and cyberattacks. This project utilized power hardware in the loop (PHiL) to gain system behavior knowledge and robust understanding through experimentation and observational science. It also produced a large volume of datasets to feed into other efforts to advance high-fidelity model simulations and to support the design of novel control approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security assessment and impact analysis of cyberattacks in integrated T&D power systems

In this paper, we examine the impact of cyberattacks in an integrated transmission and distribution (T&D) power grid model with distributed energy resource (DER) integration. We adopt the OCTAVE Allegro methodology to identify critical system assets, enumerate potential threats, analyze and prioritize risks for threat scenarios. Based on the analysis, attack strategies and exploitation scenarios are identified which could lead to system compromise. Specifically, we investigate the impact of data integrity attacks in inverted-based solar PV controllers, control signal blocking attacks in protective switches and breakers, and coordinated monitoring and switching time-delay attacks. Index Terms—Cyberattacks, security assessment, impact analysis, case studies, integrated power systems.

14 SOLAR ENERGY↗

Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability

In fall 2019, the National Association of Regulatory Utility Commissioners (NARUC) and the National Association of State Energy Officials (NASEO) initiated a joint Microgrids State Working Group (MSWG), funded by the U.S. Department of Energy (DOE) Office of Electricity (OE). The MSWG aims to bring together NARUC and NASEO members to explore the capabilities, costs, and benefits of microgrids; discuss barriers to microgrid development; and develop strategies to plan, finance, and deploy microgrids to improve resilience. This report, Clean Energy Microgrids: Considerations for State Energy Offices and Public Utility Commissions to Increase Resilience, Reduce Emissions, and Improve Affordability, focuses specifically on how clean energy microgrids can achieve both resilience and clean energy benefits. The paper provides an overview of the challenges faced by clean energy microgrids, outlines benefits that clean energy microgrids can provide, and details economic and cost considerations for the development of clean energy microgrid projects. Outlined in the paper are the necessary technological components of a clean energy microgrid, including generation, storage, energy efficiency measures, and smart controls. Current technologies are highlighted, along with potential configurations of clean technologies that are approaching cost competitiveness with commercially available options. The paper concludes with both policy and regulatory considerations for State Energy Offices and Public Utility Commissions to enhance the development and deployment of clean energy microgrids. Although it touches on the clean energy microgrids’ role in integrating distributed energy resources (DERs) into the larger grid, this is not the focus of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

controller hardware-in-the-loop↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensing Electrical Networks Securely & Economically (SENSE)

The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sequential Perturbation-based FDIA Detection using DERs for Unbalanced Distribution System

The power distribution system with its reliance on automated monitoring and control infrastructure makes it a complicated cyber-physical system and vulnerable to various cyber-attacks. This paper proposes a moving target defense inspired false data injection attack (FDIA) detection mechanism for an unbalanced distribution system. In the proposed grid diagnosis service framework, the distribution system operator judiciously manipulates power outputs of a subset of inverter-based distribution energy resources (DERs) to create secret low magnitude voltage perturbations which are inconsequential to the normal operation of the grid. A mixed-integer-linear-programming algorithm is developed to select the optimal set of DERs that can create a voltage perturbation signal of the required magnitude at each sensor location at a minimum cost. Then, a sequential detector is applied that detects for the FDIA as measurements are received from individual sensors. The performance of the proposed perturbation-based FDIA detection framework is demonstrated via simulation of the IEEE 123 bus test system.

Attack Detection↗

A Case Study about Energy and Cost Impacts for Different Community Scenarios Using a Community-Scale Building Energy Modeling Tool

The United States building sector consumed approximately 75% of electricity in 2019. By implementing renewable energy technologies and control strategies into buildings, future buildings will serve as energy generators as well as consumers. To accommodate this transition, communications among buildings and between buildings and the grid could provide more possibilities to optimize the energy performance of buildings. This paper develops a community-scale building energy model tool and conducts a case study adopting behind-the-meter distributed energy resources, sharing energy in different buildings, and using different electricity tariff structures. Three scenarios are studied: (1) electricity only supplied by the grid, (2) photovoltaic (PV) panels installed on and available to some but not all buildings, and (3) a connected community. To consider the impacts of locations and energy tariffs, this paper selects four cities and three electricity tariffs to evaluate the energy and cost performances of these three scenarios. The results show that the PV panels in Scenario 2 reduce 25% to 33% of the community-level electricity consumption and 20% to 30% of the community-level electricity cost compared with Scenario 1 in all studied locations and energy tariffs. By considering power management in the connected community (Scenario 3), the electricity consumption and cost can be further reduced by 6% to 7% and 5% to 11%, respectively, compared with Scenario 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interoperable, Inverter - Based Distributed Energy Resources Enable 100% Renewable and Resilient Utility Microgrids

As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.

battery energy storage↗

FY2021 Isolated Grids and Grid-Connected Turbine Reference Systems

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. However, there are technical barriers to realizing the market value and resilience benefits of distributed wind, and there is little to no ability to quantify those benefits so that stakeholders can compare grid investment options. The central aims of this report are: (1) to drive technology transfer of the methods and technologies developed under the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project and (2) increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply. We achieve this aim by applying three major methods developed under MIRACL to two real-world distributed wind reference systems. The two real-world distributed wind reference systems are the isolated grid of St. Mary’s, Alaska, and the two 10.5-megawatt (MW) front-of-the-meter wind turbine deployments owned and operated by Iowa Lakes Electric Cooperative (ILEC).

17 WIND ENERGY↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗