Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Prediction of human gait parameters from temporal measures of foot-ground contact

Investigation of the influence of human physical activity on bone functional adaptation requires long-term histories of gait-related ground reaction force (GRF). Towards a simpler portable GRF measurement, we hypothesized that: 1) the reciprocal of foot-ground contact time (1/tc); or 2) the reciprocal of stride-period-normalized contact time (T/tc) predict peak vertical and horizontal GRF, loading rates, and horizontal speed during gait. GRF data were collected from 24 subjects while they walked and ran at a variety of speeds. Linear regression and ANCOVA determined the dependence of gait parameters on 1/tc and T/tc, and prediction SE. All parameters were significantly correlated to 1/tc and T/tc. The closest pooled relationship existed between peak running vertical GRF and T/tc (r2 = 0.896; SE = 3.6%) and improved with subject-specific regression (r2 = 0.970; SE = 2.2%). We conclude that temporal measures can predict force parameters of gait and may represent an alternative to direct GRF measurements for determining daily histories of habitual lower limb loading quantities necessary to quantify a bone remodeling stimulus.

NASA Center ARC↗

Stabilization of posture by precision contact of the index finger

Postural sway during quiet stance increases if sight of the surroundings is denied. We studied how sensory-motor information about body displacement provided by contact of the index finger with a stationary bar can be used to stabilize balance in the absence of vision. Stabilization equivalent to the contribution conferred by vision was achieved at contact force levels less than 1 N. This value is much below that necessary to provide significant physical stabilization of the body. We interpret our findings in relation to tactile thresholds for motion detection, "precision grip," and proprioceptive and sensory-motor information about the configuration of the arm to the torso. In conditions allowing higher force levels at the fingertip (5-8 N), subjects assumed a passively stable state to stabilize their stance.

Non-NASA Center↗

'Contact' in Space Leads to New Lenses

While gravity has its advantages in keeping us balanced and grounded here on Earth, scientists often find that they are at a disadvantage when trying to conduct research under its powerful, pulling influence. In these instances, the scientists prefer performing their studies in the weightless atmosphere of microgravity, where gravity is greatly reduced and solids, liquids, and gases behave differently. In 1993, Paragon Vision Sciences, Inc., of Mesa, Arizona, participated in a research project with NASA's Langley Research Center to perfect a process for developing contact lenses. The project called for three experiments that would fly onboard the Space Shuttle over the course of three separate missions, from 1993 to 1996. By unleashing contact lens materials to the microgravity settings of space, scientists from NASA and Paragon hoped to better understand how polymers - large molecules that make up plastics - are formed.

Source record↗

Thermally Stable Ohmic Contacts on Silicon Carbide Developed for High- Temperature Sensors and Electronics

The NASA aerospace program, in particular, requires breakthrough instrumentation inside the combustion chambers of engines for the purpose of, among other things, improving computational fluid dynamics code validation and active engine behavioral control (combustion, flow, stall, and noise). This environment can be as high as 600 degrees Celsius, which is beyond the capability of silicon and gallium arsenide devices. Silicon-carbide- (SiC-) based devices appear to be the most technologically mature among wide-bandgap semiconductors with the proven capability to function at temperatures above 500 degrees Celsius. However, the contact metalization of SiC degrades severely beyond this temperature because of factors such as the interdiffusion between layers, oxidation of the contact, and compositional and microstructural changes at the metal/semiconductor interface. These mechanisms have been proven to be device killers. Very costly and weight-adding packaging schemes that include vacuum sealing are sometimes adopted as a solution.

Okojie, Robert S.↗

How Does a Liquid Wet a Solid? Hydrodynamics of Dynamic Contact Angles

A contact line is defined at the intersection of a solid surface with the interface between two immiscible fluids. When one fluid displaces another immiscible fluid along a solid surface, the process is called dynamic wetting and a "moving" contact line (one whose position relative to the solid changes in time) often appears. The physics of dynamic wetting controls such natural and industrial processes as spraying of paints and insecticides, dishwashing, film formation and rupture in the eye and in the alveoli, application of coatings, printing, drying and imbibition of fibrous materials, oil recovery from porous rocks, and microfluidics.

Rame, Enrique↗

Contact Angle of Drops Measured on Nontransparent Surfaces and Capillary Flow Visualized

The spreading of a liquid on a solid surface is important for various practical processes, and contact-angle measurements provide an elegant method to characterize the interfacial properties of the liquid with the solid substrates. The complex physical processes occurring when a liquid contacts a solid play an important role in determining the performance of chemical processes and materials. Applications for these processes are in printing, coating, gluing, textile dyeing, and adhesives and in the pharmaceutical industry, biomedical research, adhesives, flat panel display manufacturing, surfactant chemistry, and thermal engineering.

Chao, David F.↗

Contact transfer of anions from hands as a function of the use of hand lotions

Contact transfer of anions from human hands can result in contamination of materials, increasing their rate of corrosion. Two types of hand lotion were applied to the hands: one was specially formulated for cleanroom use and the other was a popular commercial lotion. The effect on contact transfer of anions was measured versus anion transfer from washed hands without lotions.

ESD contamination hand lotions↗

Carbon nanotube Schottky diodes using Ti-Schottky and Pt-ohmic contacts for high frequency applications

We have demonstrated Schottky diodes using semiconducting single-walled nanotubes (s-SWNTs) with titanium Schottky and platinum Ohmic contacts for high-frequency applications. The diodes are fabricated using angled evaporation of dissimilar metal contacts over an s-SWNT. The devices demonstrate rectifying behavior with large reverse bias breakdown voltages of greater than 15 V. To decrease the series resistance, multiple SWNTs are grown in parallel in a single device, and the metallic tubes are burnt-out selectively. At low biases these diodes showed ideality factors in the range of 1.5 to 1.9. Modeling of these diodes as direct detectors at room temperature at 2.5 terahertz (THz) frequency indicates noise equivalent powers (NEP) potentially comparable to that of the state-of-the-art gallium arsenide solid-state Schottky diodes, in the range of 10-13 W(square root)xHz.

semiconducting↗

Measurement of Creep Properties of Ultra-High-Temperature Materials by a Novel Non-Contact Technique

A non-contact technique for measuring the creep properties of materials has been developed and validated as part of a collaboration among the University of Massachusetts, NASA Marshall Space Flight Center Electrostatic Levitation Facility (ESL), and the University of Tennessee. This novel method has several advantages over conventional creep testing. The sample is deformed by the centripetal acceleration from the rapid rotation, and the deformed shapes are analyzed to determine the strain. Since there is no contact with grips, there is no theoretical maximum temperature and no concern about chemical compatibility. Materials may be tested at the service temperature even for extreme environments such as rocket nozzles, or above the service temperature for accelerated testing of materials for applications such as jet engines or turbopumps for liquid-fueled engines. The creep measurements have been demonstrated to 2400 C with niobium, while the test facility, the NASA MSFC ESL, has processed materials up to 3400 C. Furthermore, the ESL creep method employs a distribution of stress to determine the stress exponent from a single test, versus the many tests required by conventional methods. Determination of the stress exponent from the ESL creep tests requires very precise measurement of the surface shape of the deformed sample for comparison to deformations predicted by finite element models for different stress exponents. An error analysis shows that the stress exponent can be determined to about 1% accuracy with the current methods and apparatus. The creep properties of single-crystal niobium at 1985 C showed excellent agreement with conventional tests performed according to ASTM Standard E-139. Tests on other metals, ceramics, and composites relevant to rocket propulsion and turbine engines are underway.

Hyers, Robert W.↗

Near-Earth Asteroid 2005 CR37: Radar Images and Photometry of a Candidate Contact Binary

Arecibo (2380 MHz, 13 cm) radar observations of 2005 CR37 provide detailed images of a candidate contact binary: a 1.8-km-long, extremely bifurcated object. Although the asteroid's two lobes are round, there are regions of modest topographic relief, such as an elevated, 200-m-wide facet, that suggest that the lobes are geologically more complex than either coherent fragments or homogeneous rubble piles. Since January 1999, about 9% of NEAs larger than approx.200 m imaged by radar can be described as candidate contact binaries.

asteroids↗

Semiconductor ohmic contact

A semiconductor device has one surface of P type conductivity material having a wide energy bandgap and a large crystal lattice parameter. Applied to the P type surface of the semiconductor device is a degenerate region of semiconductor material, preferably a group III-V semiconductor material, having a narrower energy bandgap. The degenerate region is doped with tin to increase the crystal lattice of the region to more closely approximate the crystal lattice of the one surface of the semiconductor device. The degenerate region is compensatingly doped with a P type conductivity modifier. An electrical contact is applied to one surface of the degenerate region forming an ohmic contact with the semiconductor device.

Hawrylo, Frank Zygmunt↗

Ohmic contact for P type indium phosphide

A body including P type indium phosphide has an ohmic contact thereon of an alloy of by weight 81% to 86% gold (Au), 11% to 14% germanium (Ge) and 2% to 5% zinc (Zn). This contact has a low resistance and good adhesion to the indium phosphide body.

Hawrylo, Frank Z.↗

Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

Low leakage, non-contacting finger seals have potential to reduce gas turbine engine specific fuel consumption by 2 to 3 percent and to reduce direct operating costs by increasing the time between engine overhauls. A non-contacting finger seal with concentric lift-pads operating adjacent to a test rotor with herringbone grooves was statically tested at 300, 533, and 700 K inlet air temperatures at pressure differentials up to 576 kPa. Leakage flow factors were approximately 70 percent less than state-of-the-art labyrinth seals. Leakage rates are compared to first order predictions. Initial spin tests at 5000 rpm, 300 K inlet air temperature and pressure differentials to 241 kPa produced no measurable wear.

Proctor, Margaret P.↗

Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

Low leakage, non-contacting finger seals have potential to reduce gas turbine engine specific fuel consumption by 2 to 3 percent and to reduce direct operating costs by increasing the time between engine overhauls. A non-contacting finger seal with concentric lift-pads operating adjacent to a test rotor with herringbone grooves was statically tested at 300, 533, and 700 K inlet air temperatures at pressure differentials up to 576 kPa. Leakage flow factors were approximately 70 percent less than state-of-the-art labyrinth seals. Leakage rates are compared to first order predictions. Initial spin tests at 5000 rpm, 300 K inlet air temperature and pressure differentials to 241 kPa produced no measurable wear.

Proctor, Margaret P.↗

Non-Contact Measurement of Density and Thickness Variation in Dielectric Materials

This non-contact, single-sided terahertz electromagnetic measurement and imaging method characterizes micro structural (e.g., spatially-lateral density) and thickness variation in dielectric (insulating) materials. This method was demonstrated for space shuttle external tank sprayed-on foam insulation and has been designed for use as an inspection method for current and future NASA thermal protection systems and other dielectric material inspection applications where no contact can be made with the sample due to fragility and it is impractical to use ultrasonic methods

Roth, Ron↗

Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications

The purpose of this study was to determine the effect of atomic oxygen (AO) exposure on the hydrophilicity of nine different polymers for biomedical applications. Atomic oxygen treatment can alter the chemistry and morphology of polymer surfaces, which may increase the adhesion and spreading of cells on Petri dishes and enhance implant growth. Therefore, nine different polymers were exposed to atomic oxygen and water-contact angle, or hydrophilicity, was measured after exposure. To determine whether hydrophilicity remains static after initial atomic oxygen exposure, or changes with higher fluence exposures, the contact angles between the polymer and water droplet placed on the polymer s surface were measured versus AO fluence. The polymers were exposed to atomic oxygen in a 100-W, 13.56-MHz radio frequency (RF) plasma asher, and the treatment was found to significantly alter the hydrophilicity of non-fluorinated polymers. Pristine samples were compared with samples that had been exposed to AO at various fluence levels. Minimum and maximum fluences for the ashing trials were set based on the effective AO erosion of a Kapton witness coupon in the asher. The time intervals for ashing were determined by finding the logarithmic values of the minimum and maximum fluences. The difference of these two values was divided by the desired number of intervals (ideally 10). The initial desired fluence was then multiplied by this result (2.37), as was each subsequent desired fluence. The flux in the asher was determined to be approximately 3.0 x 10(exp 15) atoms/sq cm/sec, and each polymer was exposed to a maximum fluence of 5.16 x 10(exp 20) atoms/sq cm.

deGroh, Kim↗

Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

The baseline non-contacting finger seal is a NASA patented design. The primary difference between it and Gul Aroras design patented by AlliedSignal is that there are no lift pads on the high pressure fingers. The baseline non-contacting finger seal is comprised of a back plate, aft spacer, aft (or low pressure) finger element, forward (or high pressure) finger element, forward spacer, and front plate. The components are held together with 20 flat head screws. A typical seal would have a back plate of approximately the same thickness as the front plate and would be riveted together. The thicker back plate allows use of threaded fasteners so that different finger elements can be tested without having to replace all the individual seal components. The finger elements are essentially washers made of thin sheet stock with multiple curved slots machined around the inner diameter to form the fingers. They are clocked so that the fingers of one cover the slots of the other. The aft finger element fingers have axial extensions or "lift pads" at the seal id that are concentric to the rotor. The fingers act as cantilever beams and flex in response to rotor dynamic motion and radial growth of the rotor due to centrifugal or thermal forces.

Proctor, Margaret P.↗

Better Back Contacts for Solar Cells on Flexible Substrates

Improved low-resistance, semitransparent back contacts, and a method of fabricating them, have been developed for solar photovoltaic cells that are made from thin films of I-III-VI2 semiconductor materials on flexible, high-temperatureresistant polyimide substrates or superstrates. The innovative aspect of the present development lies in the extension, to polyimide substrates or superstrates, of a similar prior development of improved low-resistance, semitransparent back contacts for I-III-VI2 solar cells on glass substrates or superstrates. A cell incorporating this innovation can be used either as a stand-alone photovoltaic device or as part of a monolithic stack containing another photovoltaic device that utilizes light of longer wavelengths.

Woods, Lawrence M.↗