Four-Circular-Coil Systems
Turns-ratio and flux density parameters for four circular coil systems
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Turns-ratio and flux density parameters for four circular coil systems
Magnetic field intensity and field gradients for four octagonal coil systems
Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.
The combination of block copolymer (BCP) thin film self-assembly and selective infiltration synthesis of inorganic materials into one BCP block provides access to various organic–inorganic hybrids. Here, we apply sequential infiltration synthesis, a vapor-phase hybridization technique, to selectively introduce ZnO into the organic microdomains of silicon-containing rod-coil diblock copolymers and a triblock terpolymer, polydimethylsiloxane (PDMS)-b-poly{2,5-bis[(4-methoxyphenyl)-oxycarbonyl]styrene} (PDMS-b-PMPCS) and PDMS-b-polystyrene-b-PMPCS (PDMS-b-PS-b-PMPCS), in which the PMPCS rod block is a liquid crystalline polymer. The in-plane cylindrical PDMS-b-PMPCS and core–shell cylindrical and hexagonally perforated lamellar PDMS-b-PS-b-PMPCS films were infiltrated with ZnO with high selectivity to the PMPCS. The etching contrast between PDMS, PS and the ZnO-infused PMPCS enables the fabrication of ZnO/SiO x binary composites by plasma etching and reveals the core–shell morphology of the triblock terpolymer.
RF cavities are used to re-accelerate muons that have been cooled by absorbers that are in low beta regions of a muon ionization cooling channel. A superconducting coupling magnet (or magnets) are around or among the RF cavities of a muon ionization-cooling channel. The field from the magnet guides the muons so that they are kept within the iris of the RF cavities that are used to accelerate the muons. This report compares the use of a single short coupling magnet with an extended coupling magnet that has one or more superconducting coils as part of a muon-cooling channel of the same design as the muon ionization cooling experiment (MICE). Whether the superconducting magnet is short and thick or long and this affects the magnet stored energy and the peak field in the winding. The magnetic field distribution also affects is the muon beam optics in the cooling cell of a muon cooling channel.
In this paper we present a finite element model using the commercial COMSOL software package for calculating the ac loss in bifilar stacks of high temperature superconducting tape. In the model, the current-voltage relationship characterizing the superconducting properties is assumed to follow a power law. The calculations were performed for infinite bifilar stacks with different values of layer-to-layer separation D. With appropriate settings for the boundary conditions, the numerical results agree well with the analytical data obtained from a recently proposed model [J. R. Clem, Phys. Rev. B 77, 134506 (2008)]. The numerical approach was also used to investigate the end effects in a bifilar stack to answer the following question: how many layers away from the end of a stack are required before the environment of a given layer is identical to that in an infinite stack? We find that the answer to this question depends strongly on the value of D. Based on this study, a model for calculating the ac loss in bifilar noninductively wound coils with a finite number of turns is proposed.
The modified Rogowski sine-coil (MRSC) has been designed and implemented for the plasma column horizontal displacement measurements on small IR-T1 tokamak. MRSC operation has been examined on test assembly and tokamak. Obtained results show high sensitivity to the plasma column horizontal displacement and negligible sensitivity to the vertical displacement; linearity in wide, {+-}0.1 m, range of the displacements; and excellent, 1.5%, agreement with the results of numerical solution of Biot-Savart and magnetic flux equations.
The primary structural component of the cable-in-conduit conductor (CICC) magnets, such as the ITER TF coils is the conduit. This function creates requirements for 4 K strength, toughness, fatigue crack resistance, and ductility after exposure to the superconductor's reaction heat treatment. The tensile ductility of a steel is a quality factor related to fatigue and fracture resistance that can be evaluated more economically with tensile tests rather than fatigue and fracture tests. We subject 316LN modified base metal and welds to a range of cold work from 0% to 20% and a subsequent Nb 3 Sn reaction heat treatment to evaluate the effects on the tensile properties. With the addition of cold work, the 4 K yield strength increases while tensile elongation decreases in both the base metal and weld. Our results are compared to previously published data on the same alloy to evaluate the use of tensile ductility parameters as a materials qualification specification in magnet design.
The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.
The first MICE Coupling Coil has been tested in a conduction-cooled environment in the new Solenoid Test Facility at Fermilab. We present an overview of the power and quench protection scheme, and report on the electrical and quench performance results obtained during cold power tests of the magnet.
The Next Generation Nuclear Plant project is aimed at the research and development of a helium-cooled high-temperature gas reactor that could generate both electricity and process heat for the production of hydrogen. The heat from the high-temperature primary loop must be transferred via an intermediate heat exchanger to a secondary loop. Using RELAP5-3D, a model was developed for two of the heat exchanger options a printed-circuit heat exchanger and a helical-coil steam generator. The RELAP5-3D models were used to simulate an exponential decrease in pressure over a 20 second period. The results of this loss of coolant analysis indicate that heat is initially transferred from the primary loop to the secondary loop, but after the decrease in pressure in the primary loop the heat is transferred from the secondary loop to the primary loop. A high-temperature gas reactor model should be developed and connected to the heat transfer component to simulate other transients.
The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers with a focus on ductless hydronic delivery systems that utilize water-to-air terminal units in each zone. Results indicate that annual heating and cooling energy use can be reduced by up to 27% assuming replacement of the conventional 13 SEER heat pump and coil with a similarly rated air-to-water heat pump.
Since claims of ultra-high (up to ~ 1.5 kiloTesla) magnetic fields appeared in the scientific literature, it became necessary to conduct controlled experiments to determine the validity of these claims and assess the real capability of laser-driven coils (LDCs) to produce high B-field to be used in HEDP (high energy density physics) experiments. This project assessed the viability of generating magnetic fields using LDCs. This was accomplished with a thorough analysis of several focused experiments on the OMEGA EP laser at LLE designed to measure the magnetic field inside LDCs. We demonstrated how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.
This archive contains data related to the paper, "A framework for discrete optimization of stellarator coils", published in Nuclear Fusion (https://doi.org/10.1088/1741-4326/adbb02). Included are data plotted in the figures, as well as scripts for reproducing the results in the paper.
Modulation of spinning coil electromotive force by magnetic signal
Computer analysis of problems of four circular- coil system