The Princeton Field-Reversed Configuration for Compact Nuclear Fusion Power Plants

The Princeton Field-Reversed Configuration (PFRC) nuclear fusion reactor concept is an innovative approach to fusion power generation prioritizing low neutron production and small size. Here, a combination of analytical modeling and numerical simulation shows that the novel heating approach generates an FRC with closed field lines. Simulation data from a single-particle Hamiltonian code predicts ms-scale plasma heating in reactor-scale conditions while PIC codes predict formation of warm FRC plasmas from initial mirror fields. The PFRC-1 and PFRC-2 experiments have heated electrons to energies well in excess of 100 eV and plasma durations to 300 ms, more than 10 4 times longer than the predicted tilt instability growth time. From these data, we have created a development plan and anticipated performance metrics for a fusion reactor based on the PFRC concept. The resulting 1–10 MW PFRC reactors would be suitable for diverse applications, from submarines to urban environments to space propulsion. PFRC is a steady-state, driven magnetic confinement device. Plasma, inside a cylindrical array of coils, is confined and heated by external RF antennae. PFRC would be ultra-low radiation due to both its fuel and small size. The choice of advanced fuels, deuterium and helium-3 (D– 3 He), may be enabled by the high-β FRC configuration. The small size of the reactor would enable rapid exhaust of the dangerous tritium ash. Low radiation would make the reactor safer to operate and, in combination with simple geometry and small size, dramatically lowers development and maintenance costs. This review paper gives an introduction to the physics of the PFRC and a summary of the PFRC-2 experiment results to date. It then discusses the future program plan and how PFRC reactors would be commercialized.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Polywell Revisited

The Polywell fusion concept, originally proposed by Robert W. Bussard in 1985, has been investigated for over four decades as a potential solution for achieving net fusion energy in a compact and economically viable reactor. It combines two distinct approaches: high-beta magnetic cusp confinement of electrons using polyhedral coil configurations and electrostatic ion confinement via a potential well formed by injected electron beams. While the hybrid nature of the Polywell system offers advantages in plasma stability and engineering simplicity, previous efforts have been limited by persistent challenges in achieving sufficient plasma confinement required to generate a net energy gain. Here, in this study, we examine previous works and identify limitations of several Polywell embodiments that have historically impeded progress. We present an updated Polywell physics model incorporating experimental findings and recent first-principles particle-in-cell simulations. This updated model outlines a credible path toward overcoming confinement losses and achieving net energy gain using deuterium-tritium (D-T) fuels. Our findings provide a renewed scientific basis for the continued development of the Polywell fusion concept as a practical and scalable approach to fusion energy.

Electrostatic potential well↗

A new discovery of edge localized modes suppression using ICRH

Here, the high-confinement mode (H-mode) is very important for the fusion performance of ITER and future fusion reactors. The H-mode pedestal is a region featuring strongly reduced turbulence and transport just inside the limiting flux surface with strong plasma gradients, which drive edge localized modes (ELMs) in tokamaks. The ELMs, however, are quasiperiodic relaxations of the pedestal, resulting in a series of hot plasma eruptions similar to magnetospheric substorms, solar and stellar flares, which could potentially damage the ITER divertor plates and first walls. To mitigate and suppress the ELMs in H-mode plasmas, the fusion community has tried to develop effective actuators over the past two decades. Two separate excellent inventions have been awarded to recognize their achievements. The 2018 APS excellence award in Plasma Physics Research was given to Drs. Todd E. Evans, Max E. Fenstermacher, and Richard Alan Moyer for their first experimental demonstration of the stabilization of ELMs in high-confinement diverted discharges by application of very small edge-resonant magnetic perturbations, which led to the adoption of suppression coils in the ITER design. The 2018 Fusion Technology Award from the IEEE’s Nuclear and Plasma Science Society (NPSS) was given to Dr. Larry Baylor for his work designing the fueling, pumping and disruption mitigation system for the US ITER Project and for the implementation of pellet ELM mitigation for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in Processing, Manufacturing, and Applications of Magnetic Materials

Magnetic materials are increasingly important for many green energy technologies. Probably, the best known of these are permanent magnets. They are used to supply a magnetic field and are widely used in actuators, motors, generators, data storage, and sensors. These are “hard magnets,” meaning that they retain a large permanent magnetization (difficult to be demagnetized), which is what makes them so useful in motors where an opposing magnetic field can be used to push against them. A coercivity (resistance to demagnetization) of ~400 Oe (32,000 A/m) or more is typically the threshold value for a hard magnet and is typical of isotropic sintered ferrite (SrFe 12 O 19 ) such as found in many “refrigerator magnets.” Comparably important soft magnets are useful for directing magnetic fields and can be very easily (de)magnetized. As such, they typically have a coercivity < 12.5 Oe (1000 A/m), and specialized very soft magnets can have coercivities < 0.00125 Oe (1 A/m). Some common applications include coil cores, transformer cores, and magnetic shielding. Additionally, they are important for many AC electrical applications such as inductors, filters, and resonators, particularly at high frequencies up to and including microwaves.

36 MATERIALS SCIENCE↗

Overview of recent progress in 3D field physics in KSTAR

Various 3D field physics challenges of magnetically confined plasmas arise when the driving source comes from either externally applied non-axisymmetric 3D magnetic perturbations or plasma instabilities inside the plasma. Recently, several key outstanding topics of 3D field physics have been extensively studied in the Korean Superconducting Tokamak Advanced Research (KSTAR), such as edge-localized-mode (ELM) control by resonant magnetic perturbation (RMP), error field (EF) control, 3D field effects on rotation and transport, and RMP-induced alteration of divertor heat flux and detachment. KSTAR has a few physically unique features (i.e., high rotation and long-pulse plasmas with a low intrinsic EF) and machine/diagnostic capabilities (i.e., 3-row in-vessel control coil and state-of-the-art 2D/3D imaging diagnostics), which have been taken advantage of until now to address critical 3D field physics issues relevant to ITER and K-DEMO. Among many remarkable achievements are the robust access to and control of n = 1 RMP ELM suppression, along with a development of its physics basis tools, parameter expansion, optimization, and long-pulse control techniques. Nonetheless, a series of unresolved 3D physics themes, as well as limited coverage of 3D field operating regimes, have also been identified as future works for the 3D field research in KSTAR. In this paper, we provide an overview about the recent progress of KSTAR 3D field physics and present future plans of KSTAR 3D research toward a future fusion reactor.

3D field physics↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Optimizing dynamic wireless charging for electric buses: A data-driven approach to infrastructure planning

The network configuration significantly impacts the performance of dynamic wireless charging (DWC) technology for electric buses. Here, this study presents a novel approach to planning charging infrastructure for public transit using data-driven nonconvex mixed-integer optimization. Integrating DWC and charging station technologies reveals a trade-off between enroute and stationary charging times. Our framework optimizes bus frequency settings and transmitter coil arrangements to minimize operational and infrastructure costs. A case study in Chattanooga, Tennessee, demonstrates the method's effectiveness in mitigating range anxiety and reducing charging expenses. This research implies that integrating DWC technology into public transit systems can enhance the feasibility and cost-effectiveness of electric bus operations, promoting sustainable urban mobility.

33 ADVANCED PROPULSION SYSTEMS↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

Performance of low-cost indoor air quality monitors for PM 2.5 and PM 10 from residential sources

Advances in particle sensor design and manufacturing have enabled the development of low-cost air quality monitors (LCMs). Here, the sensors use light scattering to estimate mass concentration and thus require evaluation for aerosols of varied composition and size distribution. We tested the performance of six LCMs designed for home use and having a retail price under US$300 in October 2018. We assessed their performance by comparing their output to reference PM 2.5 and PM 10 measurements from 21 common residential sources and from infiltrated outdoor PM 2.5 . Reference data were obtained by using gravimetric measurements to adjust time-resolved output from an aerosol spectrometer with both electrical mobility and optical particle sensors. Compared by linear regression to reference measurements, LCMs had negative intercepts and slopes of 1–2 for infiltrated outdoor PM 2.5 . Semi-quantitative responses (~50–200% of actual PM 2.5 ) were obtained for varied aerosols including minerals (ultrasonic humidifier, vacuuming, test dust); combustion products (incense, mosquito coil, extinguished candles); microwave popcorn; and cooking involving frying or grilling. LCMs had low or no response to sources for which all mass was in particles smaller than 0.25 μm, including steady candle flames and cooking without frying or grilling. PM 10 data from LCMs was more variable than PM 2.5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Xylan-cellulose core structure of oat water-extractable β-glucan macromolecule: Insight into interactions and organization of the cell wall complex

Water-extractable β-glucan with high molar mass (HM) determines health benefits of oat food. Oat β-glucan was extracted by a standardized in vitro digestion method and co-existing water-extractable polysaccharide (WEP) fraction and its HM-arabinoxylan (HM-AX) subfraction were isolated to identify their highly acid-resistant subunit and investigate molecular interactions between constituent polymers. The WEP and HM-AX samples consisted of arabinoxylans (AXs) (74 and 76 %, respectively), however, cellulose constituted the secondary component (6.6 and 12.8 %, respectively). Multi-detection HPSEC along with specific enzymatic hydrolysis of AXs revealed the presence of the HM-xylan domain (16 and 34 %, respectively) built of numerous single- and multi-component populations with random coil and rod-like conformations, which were embedded in a xylan matrix with spherical conformation and controlled the macromolecular shape. Unlike single-component populations, the multi-component ones were resistant to hydrolytic action of AX-hydrolyzing enzymes and represented the subunits that anchor matrix polysaccharides onto cellulose surface. These results indicate that water-extractable β-glucan macromolecule comprises as integral element a cellulose core with two linking populations, HM-xylan and low molar mass glucomannan, which are surrounded by a feruloylated AX-arabinan-arabinogalactan composite and next laminated by β-glucan matrix. Here, the stiff cellulose-xylan backbone is the basis of HM β-glucan organization, controlled by its cellulose-like segments.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative analysis of temperature dependent properties of commercial nuclear fuel pellet and surrogates undergoing cracking: A review

A variety of normal and accident scenarios can generate thermal stresses enough to cause cracking in light water reactor (LWR) fuel. To better understand this behavior, cracking experiments have been carried out to induce thermal gradients in fuel pellets via induction heating and direct resistance heating. In this study, Ceria (CeO 2 ) and yttria stabilized zirconia (YSZ) pellets were chosen as a surrogate fuel material for uranium dioxide (UO 2 ). Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was achieved by passing current through the specimen using a DC power supply to introduce volumetric heating to replicate reactor operating conditions. Simultaneous real-time dual imaging of the ceria pellet surface has been designed using optical and infra-red camera system to capture images of cracks and full-field temperature gradients on pellet. It was observed that YSZ pellets need a much higher voltage-current for volumetric heating and do not exhibit the cracking pattern as ceria and UO 2 , hence YSZ was ruled out for further consideration. Ceria was found to be an appropriate surrogate for UO 2 . Furthermore, the experimental set up and test conditions demand the need to primarily understand the thermo-physical, mechanical and optical properties of UO 2 and the surrogates. Thus, it is essential to have an in-depth knowledge about the various temperature dependent properties of UO 2 and CeO 2 for establishing a comparative analysis between the surrogate and UO 2 for conducting experiments.

36 MATERIALS SCIENCE↗

Numerical simulation for the design of induction heating based radio frequency reactor for ethylene production

Ethylene is a vital petrochemical compound produced in vast amounts yearly by manufacturers that have enough scale to overcome the inherent thermodynamic inefficiencies of the process. In order to address the inefficiencies that prevent smaller scale or intermittent production ethylene, investigation of new production methods are required. In this work, we investigate the use of a radio frequency (RF) based reactor system that generates heat internally as opposed to applying heat externally via steam or direct combustion of fossil fuels. In order to guide the design of an electromagnetic based reactor system, we have created a macroscale model capable of capturing heat generation at the susceptors from a produced electromagnetic field and subsequent chemical reactions. Several susceptor and induction coil designs were investigated to better understand the performance of the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ThinCurr: An open-source 3D thin-wall eddy current modeling code for the analysis of large-scale systems of conducting structures

In this paper we present a new thin-wall eddy current modeling code, ThinCurr, for studying inductively-coupled currents in 3D conducting structures -- with primary application focused on the interaction between currents flowing in coils, plasma, and conducting structures of magnetically-confined plasma devices. The code utilizes a boundary finite element method on an unstructured, triangular grid to accurately capture device structures. The new code, part of the broader Open FUSION Toolkit, is open-source and designed for ease of use without sacrificing capability and speed through a combination of Python, Fortran, and C/C++ components. Scalability to large models is enabled through use of hierarchical off-diagonal low-rank compression of the inductance matrix, which is otherwise dense. Ease of handling large models of complicated geometry is further supported by automatic determination of supplemental elements through a greedy homology approach. Here, a detailed description of the numerical methods of the code and verification of the implementation of those methods using cross-code comparisons against the VALEN code and Ansys commercial analysis software is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.