Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Deliquescence of Eutectic LiCl-KCl Diluted with NaCl for Interim Waste Salt Storage

Molten eutectic LiCl-KCl salt is a widely used electrolyte for electrorefining uranium from spent nuclear fuel. Due to the hygroscopic nature of this salt, such operations must be performed under controlled atmospheric conditions, and waste salts require careful storage to avoid deliquescence and corrosion of container materials. This study investigated a potential processing path for reducing the degree of deliquescence through dilution to varying extents with NaCl. Here, the hydration behavior of LiCl-KCl salts diluted with NaCl was evaluated in terms of mass gain due to water absorption, degree of deliquescence (including first appearances of standing water), and evidence of corrosion to stainless steel containers in a humid air environment (40°C, 20% relative humidity). In this humid air environment, pure eutectic LiCl-KCl exhibited a 50 mass % increase due to water absorption and showed evidence of standing water after 24 h. Waste salt diluted with NaCl required loadings of 89 mass % NaCl in order to prevent deliquescence and exhibited a 3 mass % increase due to water absorption. After periodic observation for 48 h, standing water was observed near all ingots with the exception of the 89 mass % NaCl samples. Dilution with 89% NaCl was also found to reduce evidence of corrosion when stored in stainless steel crucibles. While dilution with NaCl greatly decreases steady-state hydration, the storage volume is increased ~10× through this procedure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geophysical and Mineralogical Controls on the Rheology of Fracture Slip and Seal Breaching (Final Report)

This work explores the geophysical and mineralogical controls on the rheology of fractures and faults to define the modes of permeability evolution and the potential for the breaching of seals for subsurface reservoirs. In particular, the work is arranged to determine the dynamic response of faults to shear reactivation (Parts I-III), their post slip and inter-seismic healing (Parts IV-V), their response to chemically reactive alteration (Parts VI-VII) and then upscaling via digital rock physics models (Parts IIX-XI). The work first defines the principal controls on frictional strength and stability in caprocks and unconventional reservoirs and their consequences for permeability evolution in shales (Part I). This linkage is extended to explore the impact of both mineralogy (Part II) and fracture roughness (Part III) on permeability evolution and to link this to the frictional and stability behavior of faults. The important impacts of post-slip healing during interseismic periods is then delineated (Part IV) and constrained using tightly controlled observations of reactivation displacements and permeability measurement (Part V). The role of corrosive fluids in both dissolving (Part VI) and transforming (Part VII) minerals within the fracture walls and cements is then explored, together with impacts on friction, stability and permeability. Finally, process-based models are applied to upscale the friction-stability-permeability response of both gouge-filled faults (Parts VIII and IX) and rough fractures (Part X) together with chemically-driven compaction impacting long-term interseismic sealing (Part XI).

58 GEOSCIENCES↗

Corrosion of metal samples rapidly measured

Corrosion of a large number of metal samples that have been exposed to controlled environment is accurately and rapidly measured. Wire samples of the metal are embedded in clear plastic and sectioned for microexamination. Unexposed wire can be included in the matrix as a reference.

Maskell, C. E.↗

Computational Materials Research

High temperature thermoplastic polyimide polymers are incorporated in engineering structures in the form of matrix materials in advanced fiber composites and adhesives in bonded joints. Developing analytical tools to predict long term performance and screen for final materials selection for polymers is the impetus for intensive studies at NASA and major industry based airframe developers. These fiber-reinforced polymeric composites (FRPCs) combine high strength with lightweight. In addition, they offer corrosion and fatigue resistance, a reduction in parts count, and new possibilities for control through aeroelastic tailoring and "smart" structures containing fully-integrated sensors and actuators. However, large-scale acceptance and use of polymer composites has historically been extremely slow. Reasons for this include a lack of familiarity of designers with the materials; the need for new tooling and new inspection and repair infrastructures; and high raw materials and fabrication costs.

Veazie, David R.↗

Application of Emulsified Zero-Valent Iron to Marine Environments

Contamination of marine waters and sediments with heavy metals and dense non-aqueous phase liquids (DNAPLs) including chlorinated solvents, pesticides and PCBs pose ecological and human health risks through the contaminant's potential bioaccumulation in fish, shellfish and avian populations. The contaminants enter marine environments through improper disposal techniques and storm water run-off. Current remediation technologies for application to marine environments include costly dredging and off-site treatment of the contaminated media. Emulsified zero-valent iron (EZVI) has been proven to effectively degrade dissolved-phase and DNAPL-phase contaminants in freshwater environments on both the laboratory and field-scale level. However, the application to marine environments is only just being explored. This paper discusses the potential use of EZVI in brackish and saltwater environments, with supporting laboratory data detailed. Laboratory studies were performed in 2005 to establish the effectiveness of EZVI to degrade trichloroethylene (TCE) in saltwater. Headspace vials were setup to determine the kinetic rate of TCE degradation using EZVI in seawater. The reaction vials were analyzed by Gas Chromatographic/Flame Ionization Detection (GC/FID) for ethene production after a 48 day period using a GC/FID Purge and Trap system. Analytical results showed that EZVI was very effective at degrading TCE. The reaction by-products (ethene, acetylene and ethane) were produced at 71% of the rate in seawater as in the fresh water controls. Additionally, iron within the EZVI particles was protected from oxidation of the corrosive seawater, allowing EZVI to perform in an environment where zero-valent iron alone could not compete. Laboratory studies were also performed to establish the effectiveness of emulsified zero-valent metal (EZVM) to remove dissolved-phase cadmium and lead found in seawater. EZVM is comprised of a combination of magnesium and iron metal surrounded by the same oil/surfactant membrane used in EZVI. The removal of cadmium and lead from a seawater matrix is a unique challenge. It requires a system that is resistant to the corrosive nature of seawater while removing specific ions that are in a relatively low concentration compared to naturally occurring seawater salts. Laboratory studies conducted show greater than 99% removal of lead and 96% removal of cadmium from a seawater solution spiked at 5 mg/L that was treated with an Emulsified Zero-Valent Metal (EZVM). The cadmium and lead are removed from the solution as they transport across the emulsion membrane and plate out onto the zero-valent metal surface.

Brooks, Kathleen B.↗

Coupling of Nuclear Waste Form Corrosion and Radionuclide Transports in Presence of Relevant Repository Sediments

Assessments of waste form and disposal options start with the degradation of the waste forms and consequent mobilization of radionuclides. Long-term static tests, single-pass flow-through tests, and the pressurized unsaturated flow test are often employed to study the durability of potential waste forms and to help create models that predict their durability throughout the lifespan of the disposal site. These tests involve the corrosion of the material in the presence of various leachants, with different experimental designs yielding desired information about the behavior of the material. Though these tests have proved instrumental in elucidating various mechanisms responsible for material corrosion, the chemical environment to which the material is subject is often not representative of a potential radioactive waste repository where factors such as pH and leachant composition will be controlled by the near-field environment. Near-field materials include, but are not limited to, the original engineered barriers, their resulting corrosion products, backfill materials, and the natural host rock. For an accurate performance assessment of a nuclear waste repository, realistic waste corrosion experimental data ought to be modeled to allow for a better understanding of waste form corrosion mechanisms and the effect of immediate geochemical environment on these mechanisms. Additionally, the migration of radionuclides in the resulting chemical environment during and after waste form corrosion must be quantified and mechanisms responsible for migrations understood. The goal of this research was to understand the mechanisms responsible for waste form corrosion in the presence of relevant repository sediments to allow for accurate radionuclide migration quantifications. The rationale for this work is that a better understanding of waste form corrosion in relevant systems will enable increased reliance on waste form performance in repository environments and potentially decrease the need for expensive engineered barriers.Our current work aims are 1) quantifying and understanding the processes associated with glass alteration in contact with Fe-bearing materials; 2) quantifying and understanding the processes associated with glass alteration in presence of MgO (example of engineered barrier used in WIPP); 3) identifying glass alteration suppressants and the processes involved to reach glass alteration suppression; 4) quantifying and understanding the processes associated with Saltstone and Cast Stone (SRS and Hanford cementitious waste forms) in various representative groundwaters; 5) investigating positron annihilation as a new tool for the study of glass alteration; and 6) quantifying and understanding the processes associated with glass alteration under gamma irradiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controllable hydrothermal synthesis of rutile TiO{sub 2} hollow nanorod arrays on TiCl{sub 4} pretreated Ti foil for DSSC application

Rutile TiO{sub 2} nanorod arrays (TNRs) were achieved by hydrothermal process on TiCl{sub 4} pretreated Ti foil. Subsequently, TNRs were hydrothermally etched in HCl solution to form hollow TiO{sub 2} nanorod arrays (H-TNRs). The TiCl{sub 4} pretreatment plays key roles in enhancement of Ti foil corrosion resistance ability and crystal nucleation introduction for TNRs growth. TNRs with desired morphology can be obtained by controlling TiCl{sub 4} concentration and the amount of tetrabutyl titanate (TTB) accordingly. TNRs with the length of ∼1.5 μm and diameter of ∼200 nm, obtained on 0.15 M TiCl{sub 4} pretreated Ti foil with 0.6 mL TTB, exhibits relatively higher photocurrent. The increased pore volume of the H-TNRs has contributed to the increased surface area which is benefit for Dye-Sensitized Solar Cells (DSSC) application. And the 180 °C-H-TNRs photoanode obtained from the 0.15-TiCl{sub 4}-TNRs sample demonstrated 128.9% enhancement of photoelectric efficiency of DSSC compared to that of the original TNR photoanode. - Graphical abstract: Rutile hollow TiO{sub 2} nanorod array photoanode obtained from original TiO{sub 2} nanorod array photoanode by hydrothermal etching demonstrates enhanced photoelectric efficiency of DSSC. - Highlights: • TiO{sub 2} nanorods are prepared via hydrothermal process on TiCl{sub 4}-pretreated Ti foil. • Hollow TiO{sub 2} nanorods are obtained by hydrothermal etching of TiO{sub 2} nanorods. • TiCl{sub 4} pretreatment plays a key role in protecting Ti foil from chemical corrosion. • Hollow TiO{sub 2} nanorods photoanode shows enhanced photoelectric efficiency for DSSC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Micro-arc Oxidation Coatings on 6N01 Aluminum Alloy Under Different Electrolyte Temperature Control Modes

The micro-arc oxidation coatings of 6N01 aluminum alloy produced under different control modes of the electrolyte temperature are discussed in detail. Compared to those coated by a thermostatically controlled treatment, the coatings had different surface characterizations when they were coated without controlling the electrolyte temperature, particularly after treatment involving boiling electrolytes. Scanning electron microscopy and confocal laser scanning microscopy were used to observe the morphology of the coatings. Energy-dispersive spectrometry and x-ray diffractometer were used to characterize their elemental and crystalline phase compositions. The results indicate that the treatment without a controlled electrolyte temperature ultimately led to a thicker and rougher film with a respectably thick inner barrier film, a lower content of γ-Al{sub 2}O{sub 3} and better corrosion resistance.

36 MATERIALS SCIENCE↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Investigation of Corrosion Behavior of Ti/TiN Multilayers on Al7075 Deposited by High-Vacuum Magnetron Sputtering in 3.5% NaCl Solution

Although Al 7075 has many favorable mechanical properties such as the large strength-to-weight ratio, the relatively poor corrosion resistance has restricted industrial applications. In this work, Ti/TiN as hard multilayered and nanostructured coatings are deposited on the relatively soft Al 7075 structure by high-vacuum radio-frequency magnetron sputtering and the phase, structure, and morphology are investigated in details. The corrosion behavior is evaluated by electrochemical impedance spectroscopy in 3.5% NaCl at a pH of 7.5 for 1, 6, 12, 24, 36, 48, 60, and 72 h. At time points of 1, 6, 12, and 24 h, primary oxide layers and double layers are formed, but the corrosive medium penetrates the primary titanium nitride columnar structure. At longer time points of 24, 36, 48, 60, and 72 h, formation of stronger oxide and double layers leads to better corrosion resistance which is 14.8 times better than that observed from the uncoated substrate after immersion for 36 h. According to R{sub ct}, the corrosion resistances of the short and long immersion groups are 808.5-1984 and 808.5-1248 kΩ cm{sup 2}, respectively, thereby confirming the effectiveness of the Ti/TiN coating against corrosion in comparison with the corrosion resistance of 84.3 kΩ cm{sup 2} observed from the uncoated Al 7075. The smallest corrosion resistance of 808.5 kΩ cm{sup 2} observed at the time point of 24 h is 9.6 times that of the uncoated substrate. Graphical Abstract: A 1.4-µm-thick Ti/TiN hard nanostructured coating comprising six layers is deposited on the relatively soft Al 7075 substrate by high-vacuum radio-frequency magnetron sputtering at 100 °C. The first layer of the intermediate Ti layer cannot improve the corrosion resistance of the TiN super hard coating with a columnar structure. The second and third intermediate Ti layers play an important role in improving the corrosion resistance of Al 7075 by obstructing defects and coating damage from aggressive Cl{sup −} ions and penetration of water. The mechanism involves self-healing of defects by oxide formation and Warburg resistance by diffusion control. .

36 MATERIALS SCIENCE↗

Surface Self-nanocrystallization in Copper Electroforming

The coarse columnar grain layer generated on top of electroforming deposits leads to low surface strength and poor global performance of deposits. Here, we introduce a particle abrasive-induced surface self-nanocrystallization process, which is a part of the electroforming process rather than involving complex poststeps using special equipment. It can generate a thickness-controllable surface nanocrystalline layer on top of copper deposits for performance enhancement. In this study, surface nanocrystalline layers of 10, 20, 50 and 120 μm were fabricated on top of 500-μm-thick copper deposits. The tensile strength of copper deposits increases from 234 to 246, 330, 383 and 421 MPa, with a corresponding decrease in elongation from 26 to 25, 24, 15 and 6%, respectively. The moderately thick surface nanocrystalline layer makes the copper deposits exhibit good comprehensive mechanical properties. In addition, the surface self-nanocrystallization also makes the copper deposits show a better corrosion resistance in a neutral aqueous 0.1 M NaCl solution. This study aims to promote a convenient, controllable and reliable surface self-nanocrystallization process in electroforming for improving the global performance of deposits.

36 MATERIALS SCIENCE↗

ToF-SIMS depth profiling of altered glass

Glass and mineral corrosion usually leads to the formation of morphologically and compositionally complex surface layers that can be characterized by various analytical techniques to infer rate control mechanisms. In this study, we investigate the capabilities and limitations of time-of-flight secondary ion mass spectrometry (ToF-SIMS) to better understand chemical processes of glass corrosion. In particular, we focus on the potential impact of the ToF-SIMS ion beam on the distribution of several elements of interest in alteration layers formed on International Simple Glass, a six-oxide reference glass altered in a solution enriched in alkalis and spiked with H 2 18 O. A thin flake of glass partially altered on both sides is analyzed entirely from one side to the other to determine whether atoms weakly bonded to the solid are displaced by the beams. We highlight the beam effect on cations weakly bonded to the silicate network (Li, Na, K, and B, Ca, Cs to a lesser extent) affecting the profile shape of these elements. No impact is observed on 18 O and H, but it is demonstrated that quantification of isotopic ratios is possible only for a limited range of isotopic enrichment.

36 MATERIALS SCIENCE↗

In-situ fabrication of 3D flower-like NH4NiPO4 on Ni foam without nickel salts added for high sensitive nonenzymatic glucose detection

Highlights: • The 3D-flowerlike NH{sub 4}NiPO{sub 4} grown directly on the Ni foam without nickel salts added. • The 3D-flowerlike NH{sub 4}NiPO{sub 4} assembled by sheet-like crystals (stacked by nanoflakes). • The NH{sub 4}NiPO{sub 4/}Ni foam exhibited a low detection limit of 0.015 μM. • The electrode showed high sensitivity (6135 and 2205 μA mM{sup −1} cm{sup -2}). - Abstract: The 3D flower-like NH{sub 4}NiPO{sub 4} was successfully fabricated on nickel foam via one-step hydrothermal route without nickel salts added. In our design, nickel ions were originated from the acid corrosion of nickel foam, which decreased the concentration of nickel ion in the solution and effectively control the environmental pollution. The 3D flowers-like NH{sub 4}NiPO{sub 4} was arranged on the Ni foam, and the 3D flower-like structures were assembled by sheet-like crystals with an average thickness of 380 nm. Furthermore, the sheet-like crystals are also stacked by many layers of nanoflakes. The 3D flower-like NH{sub 4}NiPO{sub 4} modified Ni foam can be used as a binder-free electrode for non-enzymatic glucose detection. And the electrode exhibits excellent electrochemical properties with high sensitivity (6135 μA mM{sup −1} Cm{sup -2} and 2205 μA mM{sup −1} Cm{sup −2}), wide linear range (covered from 0.001–1 mM and 2–5 mM) and a low detection limit of 0.015 (3S/N) at an applied bias of 0.5 V vs. Ag/AgCl.

36 MATERIALS SCIENCE↗

A Preliminary Analysis of Dose Rates Associated with ITER CVCS Equipment/Area Location

A preliminary analysis of the ITER Chemical and Volume Control System (CVCS) Area was performed to assess dose rates outside the walls and ceiling of the facility after 1.5 years of operation at shutdown, 2 days, and 10 days after shutdown. For this purpose a simplified Monte Carlo computer model was developed using the MCNP (MCNP5 Ver. 1.51) code. Two components are included: the smaller filter tank and the larger ion exchanger. These pieces of equipment are associated with the Integrated Blanket ELM Divertor Primary Heat Transfer System, which will have the largest dose rates associated with activated corrosion products during operation in comparison with other systems. The ion exchanger contained two source regions, a 1.2-m-thick resin bed above a 0.55 m-thick skirt, and a 0.8-m-thick water region. The filter constituted an additional source. Thus the model consisted of three sources (filter, resin, water), homogeneously distributed within the appropriate source regions. However, much of the results (that address individual isotopes) are presented with the two sources in the ion exchanger combined. In these cases the sources are referred to as the 'ion exchanger source' and the 'filter source.' Dimensions for the facility and components, as well as source isotopes and strengths, and material densities, were supplied by US ITER. Because of its simplification, the model does not contain pipes. Consequently, radiation streaming through pipe penetrations, radiation emanating from the pipes, and shielding from the pipes were not considered in this analysis. Dose rates on the outside of two walls and the ceiling were calculated. The two walls are labeled as the 'long' wall (aligned with the X-axis) and the 'short' wall (aligned with the Y-axis). These walls and ceiling were nominally set to 30-cm-thick concrete. In the original analysis, standard concrete (2.3 g/cc density) was used. In addition to the shielding walls/ceiling, a floor and an additional wall opposite the long wall were added for photon scattering contributions. These were both 10-cm-thick, standard concrete structures. Other components (tanks, pipes, etc.), that were not included in the model, would potentially add additional scattering and shielding. Possibly these additional effects will be addressed in a later, more detailed analysis. The room was 29.6 m in length (X-axis), but was limited to 15 m in the model. The inside width (Y axis) and height (Z axis) were 4 m and 3.4 m, respectively. The origin for the model was located inside the room at the corner opposite the long wall and adjacent to the short wall at the floor level. The room was filled with air at standard temperature and pressure. The stainless steel (SS304) wall thicknesses for the ion exchanger and filter were 2.2 cm and 0.8 cm, respectively. The axial center of the filter was located 140 cm from the short wall and 100 cm from the long wall (outer surface). The axial center of the ion exchanger was located 440 cm from the short wall and 250 cm from the long wall (inner surface). The resin was assumed to be a homogeneous mixture of equal atom density fractions of hydrogen and carbon* at a specified density of 1.136 g/cc. The filter material was assumed to be homogeneous carbon at a specified density of 1.8 g/cc. If the filter media were stainless steel and the accumulated activity were the same, the dose rate outside the filter would be lower, provided the density of the stainless steel sintered filter material is significantly higher than 1.8g/cc. The densities of the water and air were assumed to be 1.0 g/cc and 1.096E-3 g/cc, respectively. The model included 10 small volumes placed outside the model adjacent to the wall at locations where the dose rates were expected to be highest and which showed to a degree the fall-off of the dose rate with distance along a particular wall or ceiling. These 'tally cells' are shown in Fig. 2 and are described in Table 1. Each cell had dimensions of 50 cm x 50 cm x 1 cm and was oriented so that the 1-cm-thick dimension was perpendicular to the wall against which the cell was located. Also, smaller tally volumes were placed at 5 cm (updated model), 30 cm, 50 cm, and 100 cm from each source, both radially from the outside of each component at the height of each source mid-plane, and vertically, along the axial centerline, above the ion-exchanger and below the filter. (For the ion exchanger, the vertical distance was limited to 75 cm because of interference from the ceiling.) These tally regions can be seen in Fig. 3. Each cell had dimensions of 5 cm x 5 cm x 1 cm, oriented so that the 1-cm-thick dimension was perpendicular to the X, Y or Z axis.

08 HYDROGEN↗

Augmented Monitoring and Condition Assessment Program for SNF Wet Storage Life Extension - 20489

Approximately 27 MTHM of spent nuclear fuel (SNF) owned and managed by the U.S. Department of Energy, Office of Environmental Management is stored in the L Basin at the Savannah River Site (SRS). This 'DOE SNF' is comprised of approximately 12,000 aluminum-clad, aluminum-based fuel assemblies (∼7 MTHM), and approximately 2000 non-aluminum fuel assemblies (∼20 MTHM). A program is in progress to perform Non-Destructive Examination (NDE) of the fuel and their storage containers to characterize the materials' condition, and to evaluate the effects of service to enable continued safe wet storage of the SNF. The Augmented Monitoring and Condition Assessment Program (AMCAP), a two-part program to develop and implement remote underwater Non-Destructive Examination of the aluminum SNF, and of the containers of the non-aluminum SNF, respectively, is aimed at the characterization and evaluation of corrosion degradation of aluminum fuel and container materials. The predominant design of the aluminum SNF (ASNF) stored in L Basin is the Materials Test Reactor (MTR) equivalent design, a plate fuel design. These SNF are stored in 5'' diameter tubes or 5'' x 5'' squares (called bundles) that are nominally 12' or up to 14' long. The SNF is de-bundled and inspected using a custom-designed MTR Fuel Inspection Table. The inspection table provides for indexed fuel positioning for a video camera examination with controlled lighting. A total of 10 of the SNF originating from foreign research and test reactors were selected for examination based on burnup, enrichment, and prior damage caused by service/storage history. A special inspection campaign of these 10 assemblies is in progress. The observed corrosion damage included minor to moderate attack from general corrosion, pitting, crevice, end grain and galvanic corrosion. Example results from the completed inspections are shown and discussed. The focus is a comparison of the as-received condition versus the as-found current storage condition that will serve to validate Water Chemistry and Corrosion Monitoring Programs. The non-aluminum SNF (NASNF) stored in L Basin are of diverse design that includes various geometries with claddings of stainless steel, Zircaloy, and Hastelloy. The fuel core materials include uranium alloys, oxides/mixed oxides, and carbides. These SNF materials, originating from early experimental and test reactors, are in various physical forms including single fuel elements and cut pieces. The fuel is stored in L Basin in various configurations including in direct bundled storage in aluminum tubes and in isolation cans that are in the bundles or in a larger over-size storage container (OSC). Concern with inside-out corrosion and the potential loss of configuration control and ability to handle the storage containers prompted the development of remote NDE methods that include visual and UT technologies to assess the condition of the containers. Candidate stored materials were selected for a special inspection campaign; the development of the NDE methods for the inspection for galvanic, crevice and sediment-induced corrosion (inside-out) are discussed. A summary of the SNF storage in L Basin at the SRS, and an overview of the AMCAP to enable continued safe storage of DOE SNF are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutronic Analysis of an Advanced Fuel Design Concept for the High Flux Isotope Reactor

This study presents the neutronic analysis of an advanced fuel design concept for the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) that could significantly extend the current fuel cycle length under the existing design and safety criteria. A key advantage of the fuel design herein proposed is that it would not require structural changes to the present HFIR core, in other words, maintaining the same rated power and fuel geometry (i.e., fuel plate thickness and coolant channel dimensions). Of particular practical importance, as well, is the fact that the proposed change could be justified within the bounds of the existing nuclear safety basis. The simulations herein reported employed transport theory-based and exposure-dependent eigenvalue characterization to help improve the prediction of key fuel cycle parameters. These parameters were estimated by coupling a benchmarked three-dimensional MCNP5 model of the HFIR core to the depletion code ORIGEN via the MONTEBURNS interface. The design of an advanced HFIR core with an improved fuel loading is an idea that evolved from early studies by R. D. Cheverton, formerly of ORNL. This study contrasts a modified and increased core loading of 12 kg of 235U against the current core loading of 9.4 kg. The simulations performed predict a cycle length of 39 days for the proposed fuel design, which represents a 50% increase in the cycle length in response to a 25% increase in fissile loading, with an average fuel burnup increase of {approx}23%. The results suggest that the excess reactivity can be controlled with the present design and arrangement of control elements throughout the core's life. Also, the new power distribution is comparable or even improved relative to the current power distribution, displaying lower peak to average fission rate densities across the inner fuel element's centerline and bottom cells. In fact, the fission rate density in the outer fuel element also decreased at these key locations for the proposed design. Overall, it is estimated that the advanced core design could increase the availability of the HFIR facility by {approx}50% and generate {approx}33% more neutrons annually, which is expected to yield sizeable savings during the remaining life of HFIR, currently expected to operate through 2014. This study emphasizes the neutronics evaluation of a new fuel design. Although a number of other performance parameters of the proposed design check favorably against the current design, and most of the core design features remain identical to the reference, it is acknowledged that additional evaluations would be required to fully justify the thermal-hydraulic and thermal-mechanical performance of a new fuel design, including checks for cladding corrosion performance as well as for industrial and economic feasibility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Localized Deformation as a Primary Cause of Irradiation Assisted Stress Corrosion Cracking

The objective of this project is to determine whether deformation mode is a primary factor in the mechanism of irradiation assisted intergranular stress corrosion cracking of austenitic alloys in light watert reactor core components. Deformation mode will be controlled by both the stacking fault energy of the alloy and the degree of irradiation. In order to establish that localized deformation is a major factor in IASCC, the stacking fault energies of the alloys selected for study must be measured. Second, it is completely unknown how dose and SFE trade-off in terms of promoting localized deformation. Finally, it must be established that it is the localized deformation, and not some other factor that drives IASCC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

UPT scenarios: Implications for system reliability

The objective of this project was to examine the corrosion resistance of 316L stainless steel in several urine pre-treat solutions. Four solutions were examined: untreated urine (control); urine pretreated with oxone (potassium peroxymonosulfate sulfate); urine pretreated with sodium hypochlorite (NaOCl); and urine pretreated with ozone (O3). In accordance with current procedures, all solutions but the control were acidified to a pH of 2.5 using sulfuric acid--this suppresses the generation of ammonia in the solutions and is intended to limit microbial growth. Welded and unwelded coupons were exposed to each solution. In addition, Titanium coupons (welded and unwelded) were exposed to biologically active environmental control and life support system (ECLSS) water. Microbial attachment and biofilm growth were monitored. Ozone was examined as a biocide/oxidizer/corrosion preventative (simultaneous addition) and as a remediation method (added one week after exposure). In an unrelated effort, HP 9-4-30 coupons were exposed to biologically active solutions. Corrosion rates for welded and unwelded samples were determined--results were correlated to the ongoing HP 9-4-30 weldment stress corrosion study.

Walsh, Daniel W.↗