Supersymmetric discovery potential and benchmarks for early runs at {radical}(s)=7 TeV at the LHC

We carry out an analysis of the potential of the Large Hadron Collider (LHC) to discover supersymmetry in runs at {radical}(s)=7 TeV with an accumulated luminosity of (0.1-2) fb{sup -1} of data. The analysis is done with both minimal supergravity and supergravity models with nonuniversal soft breaking. Benchmarks for early discovery with (0.1-2) fb{sup -1} of data are given. We provide an update of b-tagging efficiencies in PGS 4 appropriate for LHC analyses. A large number of signature channels are analyzed, and it is shown that each of the models exhibited are discoverable at the 5{sigma} level or more above the standard model background in several signature channels which would provide cross checks for a discovery of supersymmetry. It is shown that some of the benchmarks are discoverable with 0.1 fb{sup -1} of data again with detectable signals in several channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Practical Introduction to Benchmarking and Characterization of Quantum Computers

Rapid progress in quantum technology has transformed quantum computing and quantum information science from theoretical possibilities into tangible engineering challenges. Breakthroughs in quantum algorithms, quantum simulations, and quantum error correction are bringing useful quantum computation closer to fruition. These remarkable achievements have been facilitated by advances in quantum characterization, verification, and validation (QCVV). QCVV methods and protocols enable scientists and engineers to scrutinize, understand, and enhance the performance of quantum information-processing devices. In this tutorial, we review the fundamental principles underpinning QCVV, and introduce a diverse array of QCVV tools used by quantum researchers. We define and explain QCVV’s core models and concepts—quantum states, measurements, and processes—and illustrate how these building blocks are leveraged to examine a target system or operation. We survey and introduce protocols ranging from simple qubit characterization to advanced benchmarking methods. Along the way, we provide illustrated examples and detailed descriptions of the protocols, highlight the advantages and disadvantages of each, and discuss their potential scalability to future large-scale quantum computers. This tutorial serves as a guidebook for researchers unfamiliar with the benchmarking and characterization of quantum computers, and also as a detailed reference for experienced practitioners.

open quantum systems & decoherence↗

A round-robin approach provides a detailed assessment of biomolecular small-angle scattering data reproducibility and yields consensus curves for benchmarking

Through an expansive international effort that involved data collection on 12 small-angle X-ray scattering (SAXS) and four small-angle neutron scattering (SANS) instruments, 171 SAXS and 76 SANS measurements for five proteins (ribonuclease A, lysozyme, xylanase, urate oxidase and xylose isomerase) were acquired. From these data, the solvent-subtracted protein scattering profiles were shown to be reproducible, with the caveat that an additive constant adjustment was required to account for small errors in solvent subtraction. Further, the major features of the obtained consensus SAXS data over the q measurement range 0–1 Å −1 are consistent with theoretical prediction. The inherently lower statistical precision for SANS limited the reliably measured q -range to <0.5 Å −1 , but within the limits of experimental uncertainties the major features of the consensus SANS data were also consistent with prediction for all five proteins measured in H 2 O and in D 2 O. Thus, a foundation set of consensus SAS profiles has been obtained for benchmarking scattering-profile prediction from atomic coordinates. Additionally, two sets of SAXS data measured at different facilities to q > 2.2 Å −1 showed good mutual agreement, affirming that this region has interpretable features for structural modelling. SAS measurements with inline size-exclusion chromatography (SEC) proved to be generally superior for eliminating sample heterogeneity, but with unavoidable sample dilution during column elution, while batch SAS data collected at higher concentrations and for longer times provided superior statistical precision. Careful merging of data measured using inline SEC and batch modes, or low- and high-concentration data from batch measurements, was successful in eliminating small amounts of aggregate or interparticle interference from the scattering while providing improved statistical precision overall for the benchmarking data set.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmark study of TRIPOLI-4 through experiment and MCNP codes

Reliability on simulation results is essential in nuclear physics. Although MCNP5 and MCNPX are the world widely used 3D Monte Carlo radiation transport codes, alternative Monte Carlo simulation tools exist to simulate neutral and charged particles' interactions with matter. Therefore, benchmark are required in order to validate these simulation codes. For instance, TRIPOLI-4.7, developed at the French Alternative Energies and Atomic Energy Commission for neutron and photon transport, now also provides the user with a full feature electron-photon electromagnetic shower. Whereas the reliability of TRIPOLI-4.7 for neutron and photon transport has been validated yet, the new development regarding electron-photon matter interaction needs additional validation benchmarks. We will thus demonstrate how accurately TRIPOLI-4's 'deposited spectrum' tally can simulate gamma spectrometry problems, compared to MCNP's 'F8' tally. The experimental setup is based on an HPGe detector measuring the decay spectrum of an {sup 152}Eu source. These results are then compared with those given by MCNPX 2.6d and TRIPOLI-4 codes. This paper deals with both the experimental aspect and simulation. We will demonstrate that TRIPOLI-4 is a potential alternative to both MCNPX and MCNP5 for gamma-electron interaction simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tube Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.

60 APPLIED LIFE SCIENCES↗

QASMBench: A Low-Level Quantum Benchmark Suite for NISQ Evaluation and Simulation

The rapid development of quantum computing (QC) in the NISQ era urgently demands a low-level benchmark suite and insightful evaluation metrics for characterizing the properties of prototype NISQ devices, the efficiency of QC programming compilers, schedulers and assemblers, and the capability of quantum system simulators in a classical computer. In this work, we fill this gap by proposing a low-level, easy-to-use benchmark suite called QASMBench based on the OpenQASM assembly representation. It consolidates commonly used quantum routines and kernels from a variety of domains including chemistry, simulation, linear algebra, searching, optimization, arithmetic, machine learning, fault tolerance, cryptography, and so on, trading-off between generality and usability. To analyze these kernels in terms of NISQ device execution, in addition to circuit width and depth, we propose four circuit metrics including gate density, retention lifespan, measurement density, and entanglement variance, to extract more insights about the execution efficiency, the susceptibility to NISQ error, and the potential gain from machine-specific optimizations. Applications in QASMBench can be launched and verified on several NISQ platforms, including IBM-Q, Rigetti, IonQ and Quantinuum. For evaluation, we measure the execution fidelity of a subset of QASMBench applications on 12 IBM-Q machines through density matrix state tomography, comprising 25K circuit evaluations. In addition we also compare the fidelity of executions among the IBM-Q machines, the IonQ QPU and the Rigetti Aspen M-1 system.

97 MATHEMATICS AND COMPUTING↗

MCS solutions for the TVA Watts Bar Unit 1 multi-physics depletion benchmark

The high-fidelity solution for exercises 1-3 of the recently developed TVA Watts Bar Unit 1 multi-physics and multi-cycle depletion benchmark using MCS was coupled with two different thermal-hydraulics (TH) codes: TH1D and COBRA-TF (CTF), and their solutions were compared. The solutions from MCS/CTF and MCS/TH1D for typical Pressurized Water Reactor (PWR) problems are quite close. And to evaluate MCS solutions for the benchmark, their results were also compared against measured data as well as publicly available high-fidelity solutions. The MCS criticality solutions at Hot Zero Power (HZP) deviate within 50 pcm against the reference solutions. While for the critical boron concentration (CBC) search calculations, the difference on the MCS calculated CBC is about 7 ppm, and the root-mean-squared (RMS) errors for the assembly power distribution and outlet coolant temperature are less than 0.5% and 1 Celsius degree respectively. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An iron evaluation story: from TALYS model parameters to validation on the ASPIS benchmark with the Monte-Carlo code TRIPOLI-4

Iron is a widespread structural material in nuclear applications. However some benchmark studies show that for many libraries, including TENDL-2019, producing good iron evaluations is still an open challenge. This work aims at improving TENDL-2019 {sup 56}Fe and {sup 54}Fe evaluations through feedbacks from experimental data and Monte Carlo results of the iron benchmark ASPIS. Part of the T6 code infrastructure was used to produce the evaluations. In the new evaluations, particular attention to resonance parameters and formalism was paid to address the importance of elastic scattering. The total inelastic scattering and inelastic continuum cross sections were shaped by modifying the input parameters of TALYS, one of the T6 codes. Additionally, it was necessary to normalise some reaction channels to those of JENDL-4.0. With the new files ASPIS results, obtained with the Monte Carlo code TRIPOLI-4, improved noticeably compared to TENDL 2019. The evaluations and parameter setting modifications are to be included into TENDL-2021. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Setup and verification of a SCALE/KENO platform for generic FHR benchmark calculations

The work presented in this article is preliminary to downstream analysis of a generic fluoride salt-cooled high-temperature reactor (gFHR) core performed by the University of Tennessee in collaboration with Kairos Power (KP). A Monte Carlo transport model of the publicly available gFHR equilibrium core is developed in SCALE/KENO with multigroup energy treatment. Several output quantities of interest are used to verify the simulations against a benchmark model developed by KP using the continuous energy Monte Carlo code Serpent 2. Good agreement is seen in flux and fission rate profiles with a maximum relative difference of 1.4% and 2.8% respectively. Furthermore, an effective multiplication factor bias of 44 pcm was observed between the two simulations. The fuel temperature reactivity coefficient calculated with SCALE is within uncertainty to the reference model. This verification acts as a publicly reproducible benchmark for the gFHR in SCALE/KENO. A simplified depletion model is also presented where a single fuel pebble is depleted to discharge burnup through the equilibrium core while the equilibrium core is assumed to be invariant. This method produces results that intercept the equilibrium core concentrations in every case, however, an interesting artifact of this particular depletion model is uncovered. The phenomenon is shown to be a fundamental feature of the differential rate equations and inspires questions about how this system behaves when the time evolution of the equilibrium core is considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TRIPOLI-4 neutronics calculations for IAEA-CRP benchmark of CEFR start-up tests using new libraries JEFF-3.3 and ENDF/B-VIII

Sodium-cooled Fast Reactors (SFR) are one of the promising Generation IV fast reactors. The China Experimental Fast Reactor (CEFR) is a 65 MWth pool-type SFR with a high neutron leakage core using high enriched uranium oxide fuel. The CEFR start-up tests in 2010 consist of series of neutronics experiments. Essential experimental data are available from the 2018 IAEA-CEFR-CRP benchmark document and useful for the validation of neutron transport codes and nuclear data libraries. The TRIPOLI-4 Monte Carlo transport code is a general-purpose neutronics code using continuous-energy nuclear data libraries. It has a rich validation database covering different computational and experimental benchmark data sets to assure the accuracy and credibility of numerical studies. Previous TRIPOLI-4 SFR core physics calculations used mainly MOX fuels. SFR control rod worth studies with TRIPOLI-4 were mainly on big-size cores. To test the modeling capability of TRIPOLI-4 on fuel loading patterns and on variable control rods positions for SFRs and to check recent nuclear data libraries, it is interesting to investigate the CEFR start-up tests in this work, including core states from subcritical to supercritical, control rods and rod group worth, point kinetics parameters, and radial foil activation measurements. TRIPOLI-4 calculation results using new data libraries JEFF-3.3, ENDF/B-VIII, and those of ENDF/B-VII.1 for different CEFR core states are reported here. By means of different options of TRIPOLI-4, control-rod SAs reactivity worth, point kinetics parameters, and radial {sup 237}Np(n,f) fission rate distribution were successfully evaluated. Both ENDF/B-VIII and JEFF-3.3 nuclear data libraries provided reliable results with a difference of 170 +/- 11 pcm in k{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation of neutron flux spectra of the VVER-1000 mock-up shielding benchmark with Monte Carlo code MCS utilizing mesh-based weight window

The measurements of neutron spectra compiled inside the NEA-1517/82 package from the Shielding Integral Benchmark Archive and Database (SINBAD) are chosen as benchmark cases to validate the variance reduction technique based on weight window in Monte Carlo Code MCS. A full 3D model for fixed source mode calculation with hexagonal lattice source definition is developed to simulate total of 6 points of measurements at the vicinity of the reactor and the reactor pressure vessel region. A code/code comparison against MCNP6 code is first conducted as verification element for the mesh-based weight window capability in MCS. Finally, the validation results are presented against measurements. The verification against MCNP6 code gives good agreement in addition of the insight to the importance of user understanding to determine proper reference point and reference lower weight bound for scaling which is not required in MCS code due to its capability of automatic scaling. The comparison of neutron spectra between MCS and measurements shows good agreement within 3 standard deviations for all of six detector positions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactor physics benchmark of Westinghouse PWR core design suite for high burnup/high enrichment fuel - Part 1: Pin and lattice

Westinghouse has performed a comprehensive set of code-to-code benchmark comparisons to corroborate application of its state-of-the-art NEXUS-based code suite to high burnup and high enrichment (HB/HE) fueled PWR core design and reload analysis. This paper focuses on analysis of the predictions for pin and lattice designs representative of HB/HE core reloads from the Westinghouse advanced lattice code PARAGON2, the Monte-Carlo code SERPENT2 and MPACT, the deterministic neutronic component of VERA. A companion paper presented at this conference analyzes results obtained with the Westinghouse ANC9 core simulator, using lattice data provided by PARAGON2 with the NEXUS cross-section methodology, and MPACT for 2D and 3D core configurations incorporating HB/HE fuel reloads to achieve cycle length extension to 24-month in high-power density PWRs. The results of the pin and lattice benchmark presented in this paper show that the neutronic predictions from PARAGON2 for HB/HE fueled PWRs are in remarkable agreement with predictions from both SERPENT2 and MPACT including for depletion to high fuel burnup values, and employing a set of challenging lattices which feature combined use of burnable absorbers to obtain the required reactivity hold-down to support PWR transition to HB/HE fuel and 24-month operational cycles. As corroborated by this analysis and the analysis contained in the companion paper, the Westinghouse NEXUS-based PWR core analysis package can be confidently applied by industry for design analysis of PWR core reloads adopting HB/HE fuel and properly support the industry commercialization plans for in-reactor deployment. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adding ($\mathcal{α}$,n) Emission to an Existing Subcritical Benchmark Statistical Uncertainty Method

Subcritical measurements often use radiation detectors to infer parameters related to the physics of a measured system. One type of subcritical measurements typically performed are called neutron noise measurements. These types of measurements utilize the fact that prompt neutrons are produced from fission immediately after a fission event and are therefore correlated in time. Subcritical benchmarks require evaluation of the statistical and systematic uncertainties of a measurement. Previous work established methods for determining statistical and systematic uncertainties in subcritical benchmarks. The data were analyzed using the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. The previous work made an assumption that the ($\mathcal{α}$,n) emission rate was negligible. This assumption was used because the previous work focused on systems with metal Plutonium. This work extends the existing statistical uncertainty method to include ($\mathcal{α}$,n) emissions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison and validation of HEU and LEU modeling results to HEU experimental benchmark data for the Massachusetts Institute of Technology MITR reactor.

The Massachusetts Institute of Technology Reactor (MITR-II) is a research reactor in Cambridge, Massachusetts designed primarily for experiments using neutron beam and in-core irradiation facilities. It delivers a neutron flux comparable to current LWR power reactors in a compact 6 MW core using Highly Enriched Uranium (HEU) fuel. In the framework of its non-proliferation policies, the international community presently aims to minimize the amount of nuclear material available that could be used for nuclear weapons. In this geopolitical context, most research and test reactors both domestic and international have started a program of conversion to the use of Low Enriched Uranium (LEU) fuel. A new type of LEU fuel based on an alloy of uranium and molybdenum (UMo) is expected to allow the conversion of U.S. domestic high performance reactors like the MITR-II reactor. Towards this goal, comparisons of MCNP5 Monte Carlo neutronic modeling results for HEU and LEU cores have been performed. Validation of the model has been based upon comparison to HEU experimental benchmark data for the MITR-II. The objective of this work was to demonstrate a model which could represent the experimental HEU data, and therefore could provide a basis to demonstrate LEU core performance. This report presents an overview of MITR-II model geometry and material definitions which have been verified, and updated as required during the course of validation to represent the specifications of the MITR-II reactor. Results of calculations are presented for comparisons to historical HEU start-up data from 1975-1976, and to other experimental benchmark data available for the MITR-II Reactor through 2009. This report also presents results of steady state neutronic analysis of an all-fresh LEU fueled core. Where possible, HEU and LEU calculations were performed for conditions equivalent to HEU experiments, which serves as a starting point for safety analyses for conversion of MITR-II from the use of HEU fuel to the use of UMo LEU fuel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking Heavy Ion Transport Codes FLUKA, HETC-HEDS MARS15, MCNPX, and PHITS

Powerful accelerators such as spallation neutron sources, muon-collider/neutrino facilities, and rare isotope beam facilities must be designed with the consideration that they handle the beam power reliably and safely, and they must be optimized to yield maximum performance relative to their design requirements. The simulation codes used for design purposes must produce reliable results. If not, component and facility designs can become costly, have limited lifetime and usefulness, and could even be unsafe. The objective of this proposal is to assess the performance of the currently available codes PHITS, FLUKA, MARS15, MCNPX, and HETC-HEDS that could be used for design simulations involving heavy ion transport. We plan to access their performance by performing simulations and comparing results against experimental data of benchmark quality. Quantitative knowledge of the biases and the uncertainties of the simulations is essential as this potentially impacts the safe, reliable and cost effective design of any future radioactive ion beam facility. Further benchmarking of heavy-ion transport codes was one of the actions recommended in the Report of the 2003 RIA R&D Workshop".

43 PARTICLE ACCELERATORS↗

Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems, Using a Bottom-Up Approach and Installer Survey – Second Edition

This report presents results from the second U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs -- often referred to as 'business process' or 'soft' costs -- for U.S. residential and commercial photovoltaic (PV) systems. In service to DOE's SunShot Initiative, annual expenditure and labor-hour-productivity data are analyzed to benchmark 2012 soft costs related to (1) customer acquisition and system design (2) permitting, inspection, and interconnection (PII). We also include an in-depth analysis of costs related to financing, overhead, and profit. Soft costs are both a major challenge and a major opportunity for reducing PV system prices and stimulating SunShot-level PV deployment in the United States. The data and analysis in this series of benchmarking reports are a step toward the more detailed understanding of PV soft costs required to track and accelerate these price reductions.

14 SOLAR ENERGY↗

Select Transient Metallic Fuel Bison Benchmarks

To explore the current capabilities of Bison with respect to transient metallic fuel modeling, four transient experiments are compared with their respective Bison model. The four experiments are the OPT-1 experiment of the Experimental Breeder Reactor II~(EBR-II) and the M5, M6, and M7 experiments of the Transient Reactor Test facility (TREAT). Each benchmark is a 2D-RZ geometry of a single pin employing coupled multiphysics. Bison models of the benchmark agree well and illustrate areas needing development. The areas of suggested development deal with better material models, better coolant channel module for transients, proper treatment of material melting, improved feedback with failure models, and an ability to set initial conditions from post irradiation examination (PIE) data. Two Fast Flux Test Facility (FFTF) pins are also modeled with M7 transient conditions to illustrate Bison being applied to investigate potential experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗