Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LOSS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

An Initial Study of Using the 34-m Antenna for Lunar Missions Support

As a part of the long-range planning of future Mars and lunar missions, a rudimentary study has been made of a 34-m antenna system with differentially pointed multiple beams. The performance loss mechanisms of the differentially pointed multiple-beam systems were identified and quantified. The goal is to determine the feasibility of using the 34-m antenna to support widely separated elements associated with lunar missions.

lunar↗

Ion Acoustic Wave Frequencies and Onset Times During Type 3 Solar Radio Bursts

Conflicting interpretations exist for the low-frequency ion acoustic (S) waves often observed by ISEE 3 in association with intense Langmuir (L) waves in the source regions of type III solar radio bursts near 1 AU. Two indirect lines of observational evidence, as well as plasma theory, suggest they are produced by the electrostatic (ES) decay L yields L(PRIME) + S. However, contrary to theoretical predictions, an existing analysis of the wave frequencies instead favors the electromagnetic (EM) decays L yields T + S, where T denotes an EM wave near the plasma frequency. This conflict is addressed here by comparing the observed wave frequencies and onset times with theoretical predictions for the ES and EM decays, calculated using the time-variable electron beam and magnetic field orientation data, rather than the nominal values used previously. Field orientation effects and beam speed variations are shown analytically to produce factor-of-three effects, greater than the difference in wave frequencies predicted for the ES and EM decays; effects of similar magnitude occur in the events analyzed here. The S-wave signals are extracted by hand from a sawtooth noise background, greatly improving the association between S waves and intense L waves. Very good agreement exists between the time-varying predictions for the ES decay and the frequencies of most (but not all) wave bursts. The waves occur only after the ES decay becomes kinematically allowed, which is consistent with the ES decay proceeding and producing most of the observed signals. Good agreement exists between the EM decay's predictions and a significant fraction of the S-wave observations while the EM decay is kinematically allowed. The wave data are not consistent, however, with the EM decay being the dominant nonlinear process. Often the observed waves are sufficiently broadband to overlap simultaneously the frequency ranges predicted for the ES and EM decays. Coupling the dominance of the ES decay with this frequency overlap provides support for a previous suggestion that fundamental emission occurs when the EM decay is stimulated by the ES decay product waves. The periods in which the ES and EM decays produce observable S waves are consistent with the observed and (independently) predicted times of fundamental and harmonic radio emission. This supports interpretation of fundamental emission as stimulated EM decay and harmonic emission as the coalescence L + L(prime) yields T of beam-generated L waves and L(prime) waves produced by the ES decay, where T denotes an electromagnetic wave at twice the plasma frequency. Analysis of the electron beam data reveals that the time-varying beam speed is consistent with ballistic beam propagation with minimal energy loss, implying that the beam propagates in a state close to time- and volume-averaged marginal stability. This confirms a central tenet of the stochastic growth theory for type III bursts.

Cairns, Iver H.↗

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical and experimental investigation on magneto-hydrodynamics of plasma window

As a new device, plasma window has been designed to use plasma discharge to separate atmosphere from vacuum with high difference of pressure. It has many excellent properties, being able to be used as available passage for ion beam with negligible energy loss, also impervious to radiation damage and thermal damage. Normally beam focusing by accelerators is not that easy to achieve within channel of small cross section. 10 mm diameter plasma window's experimental realization could contribute to its further application in accelerator system. In this paper, 10 mm diameter 60 mm long plasma window has first been designed and managed to generate arc discharge with argon gas experimentally. The result proves that it has the ability to separate at least 28.8 kPa (not the upper limit) from 360 Pa with 50 A direct current and 2.5 kW power supplied. Current increase leads to linear inlet pressure increase obviously, while it has less impact on outlet pressure and voltage, coming to the conclusion that the higher current of plasma discharge, the larger pressure difference it creates. Theoretical analysis of 10 mm diameter plasma window in axis symmetrical configuration using argon also has been provided, in which a numerical 2D FLUENT-based magneto-hydrodynamic simulation model is settled. It has a good agreement with experimental result on voltage and mass flow rate when inlet pressure is increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Beam Diagnostics with Existing BPPMs via GPU-powered Multi-Particle Simulation

This research aims to utilize the multi-particle code, High-Performance Simulator (HPSim), to realistically model the Side-Coupled-Cavity Linac (CCL) lattice of the LANSCE accelerator. This new model would allow us to predict the beam’s bunch length (the longitudinal spread), which is unavailable for individual accelerating modules or only accessible at the end of the linac. However, a correct bunch length is critical for the high-energy beam transport after the CCL. Its impact would be most significant in the Proton Storage Ring (PSR), where we should be able to reduce losses for the circulating beam. The PSR is scheduled to have a 25% current increase for the neutron spallation target upgrade at the Lujan Center. A highly bunched beam would be necessary to reduce the particle losses and lower the radiation levels produced from the ring. A realistic HPSim model with >1M macro-particles can help tackle the beam losses at the sub-percent level. This new work would also create a realistic surrogate model for future machine learning projects.

43 PARTICLE ACCELERATORS↗

Electron Excitation Cross Sections for the C II Transitions 2s(exp 2)2p P-2(exp 0) yields 2s2p(exp 2) P-4, D-2, and S-2

Experimental and theoretical excitation cross sections are reported for the transitions 2s(exp 2) 2p-2(exp 0) yield 2s2p(exp 2)P-4, D-2, and S-2 in C II. The transition wavelengths (energies) are 2324 A (5.34 eV), 1335 x (9.29 eV), and 1036 A (11.97 eV), respectively. Use is made of electron energy-loss and merged beams methods. The energy range covered is from below each threshold (4 - 11 eV) to 15-24 eV. As in previous work with O II, care was taken to assess and minimize the metastable fraction in the C II beam, to account for contributions from nearby energy-loss features, and to collect the full angular range of inelastically scattered electrons. A comparison is made for each transition between experiment and new 8-state R-matrix calculations. Subject headings: atomic data ultraviolet: general

Smith, Steven J.↗

Statistical Analysis of the Eigenmode Spectrum in the SRF Cavities with Mechanical Imperfections

The superconducting radio frequency (SRF) technology is progressing rapidly over last decades toward high accelerating gradients and low surface resistance making feasible the particle accelerators operation with high beam currents and long duty factors. However, the coherent RF losses due to high order modes (HOMs) excitation becomes a limiting factor for these regimes. In spite of the operating mode, which is tuned separately, the parameters of HOMs vary from one cavity to another due to finite mechanical tolerances during cavities fabrication. It is vital to know in advance the spread of HOM parameters in order to predict unexpected cryogenic losses, overheating of beam line components and to keep stable beam dynamics. In this paper we present the method of generating the unique cavity geometry with imperfections while preserving operating mode frequency and field flatness. Based on the eigenmode spectrum calculation of series of randomly generated cavities we can accumulate the data for the evaluation the HOM statistics. Finally, we describe the procedure for the estimation of the probability of the resonant HOM losses in the SRF resonators. The study of these effects leads to specifications of SC cavity and cryomodule and can significantly impact on the efficiency and reliability of the machine operation

43 PARTICLE ACCELERATORS↗

Alternative irradiation schemes for NIF and LMJ hohlraums

Here, we explore two alternative irradiation schemes for the large ('outer') and small ('inner') angle beams that currently illuminate National Ignition Facility (NIF) and Laser Mégajoule cavities. In the first, while the outer laser beams enter through the usual end laser entrance holes (LEH), the inner beams enter through slots along the cavity axis wall, illuminating the back wall of the cavity. This avoids the current interaction of the inner laser beams with the gold wall bubbles generated by the outer beams, which leads to large time-dependent changes in drive symmetry. Another scheme potentially useful for NIF uses only the outer beams. The radiative losses through the slots or from the use of outer beams only are compensated by using a smaller cavity and LEH.

42 ENGINEERING↗

Ion-beam-textured and coated surfaces experiment (S1003)

The objective of this LDEF experiment is to measure the effects of exposure to the shuttle launch and near Earth space environments on the optical properties of ion beam textured high absorptance solar thermal control surfaces, the optical and electrical properties of ion beam sputtered conductive solar thermal control surfaces, and the weight loss of ion beam deposited oxide polymer films. The various types of surfaces to be tested include six major categories: (1) ion beam textured surfaces suitable for space solar thermal (solar concentration) application; (2) painted and/or state of the art solar thermal surfaces; (3) ion beam sputtered conductive coatings for thermal and space charge control (e.g., indium-oxide coated metalized FEP Teflon); (4) ion beam sputtered conductive coated solar sail materials for space charge control and cooling through emittance; (5) micrometeoroid sensitive samples whose optical properties change only as a result of micrometeoroid impact; and (6) Kapton coated with oxide polymer films to minimize oxygen degradation at near Earth orbit altitudes.

Mirtich, M. J., Jr.↗

Dielectric Studies on Swift Heavy Ions and Electron Irradiated Organic Single Crystal

Single crystals of 1-(4-methylphenyl)-3-(4,N,N-dimethylamino phenyl)-2-propen-1-one were irradiated with 72 MeV swift heavy ions of C-12 with different fluencies 5x10{sup 11}, 1x10{sup 12} and electrons with energy 8 MeV for a dose of 2.25 kGy. The changes in the dielectric properties of these crystals have been studied. The study shows that the dielectric constant increases first and then decreases with the increase of fluence. This variation has been discussed and possible explanations are given. The variation of dielectric loss and the ac conductivity indicates that there is some structural modification within the crystal due to irradiation. The electron irradiation induced ionic polarizibility within the crystal along the electron path, which is reflected in increase in dielectric constant and hence the conductivity.

36 MATERIALS SCIENCE↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy

Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound imaging. This acoustic range verification approach could offer the possibility of combining anatomical ultrasound and Bragg peak imaging, but further studies are required for translation of these findings to clinical application.

07 ISOTOPE AND RADIATION SOURCES↗

LAMP Emittance Budget, Rev. 1

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). This brief report summarizes the emittance budget for the LANSCE Modernization Project (LAMP). While the project Key Performance Parameters (KPPs) specify threshold and objective requirements for charge delivered to each experimental area, no upper limits on beam emittances are specified. To maintain low losses in the high-energy section of the LANSCE linac and hands-on maintenance, some upper limits on beam emittance need to be specified for the new LAMP front-end performance. The scope of the LAMP project replaces the injector section and drift-tube linac (DTL) up to 100 MeV of the existing LANSCE linac. This new design replacement will be integrated with the remaining coupled cavity linac (CCL) which makes up most of the accelerator at LANSCE and accelerates the beam to a final energy of 800 MeV. The initial approach that has been used to define an emittance budget for the new LAMP front end is based on recent and historical measured beam emittances at 100 MeV for the three beam types accelerated at LANSCE: H+ (protons for isotope production), LBEG (H- beam for delivery to proton radiography and to the Lujan neutron spallation target, and MPEG (H- beam for delivery to the Weapons Neutron Research facility). The emittance budget (upper limit) for each beam type has been selected to maintain the losses in the CCL to a level approximately equivalent to those observed in present operations to first order. However, the goal of the LAMP project is to improve the quality of the beams injected into the CCL, if possible, thus allowing for higher average current operation while also lowering beam losses and activation at high beam energies. The table below summarizes the beam measurements evaluated and used to establish a conservative emittance budget for LAMP based on known historical beam losses and activation. However, based on estimates of the CCL admittance and the Isotope Production Facility (IPF) beamline acceptance, a more relaxed transverse emittance upper limit of 0.095 π-cm-mrad, rms, normalized may be acceptable at 100 MeV while still meeting the LAMP performance requirements for charge delivery to each LANSCE experimental area and maintaining hands-on maintenance. This upper limit is supported by a recent analysis of operational data. Additionally, the present conceptual LAMP front-end design meets this requirement.

43 PARTICLE ACCELERATORS↗

Recent developments in deuterated scintillators for neutron measurements at low-energy accelerators

Deuterated ( 2 H-based) organic scintillators, unlike conventional 1 H-based scintillators can generate pulse-shape gated neutron energy spectra 1 to 30 MeV without need for time-of-flight (ToF). They are especially appropriate for measurements at high-intensity, low-energy accelerators where a pulsed beam is not available. Even when the latter is available, the loss in effective beam intensity combined with the need for suitable long-path ToF measurements can be very inefficient. In contrast, as we demonstrate, arrays of d- benzene scintillators (NE230, BC537, EJ315) and recently xylene-d10 (EJ301D) together with related digital signal processing (DSP) can provide highly efficient neutron energy measurements w/o n-ToF. Lastly, we also report the recent synthesis and initial testing of crystalline d-stilbene as a neutron detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of TlCaBaCuO 30 GHz 64 element antenna array

A 64-element, 30-GHz microstrip antenna array with corporate feed network was designed and built on a 0.254-mm (10-mil) thick lanthanum aluminate substrate. One antenna pattern was fabricated from gold film, and a second pattern used TlCaBaCuO high-temperature superconductor. Both antennas used gold ground planes deposited on the reverse side of the substrate. Gain and radiation patterns were measured for both antennas at room temperature and at cryogenic temperatures. Observations agree well with simple models for loss and microwave beam width, with a gain on boresight of 20.3 dB and beam width of 15 deg for the superconducting antenna. The antenna loss is only 1.9 dB.

Lewis, L. L.↗

Low energy beam transport system developments

For high brightness beam production it is important to preserve the brightness in the low energy beam transport system (LEBT) used to transport and match the ion beams to the next stage of acceleration, usually an RFQ. While electrostatic focusing can be problematic for high current beam transport, reliable electrostatic LEBT operation has been demonstrated with H{sup −} beams up to 60 mA. Now, however, it is commonly accepted that an optimal LEBT for high current accelerator applications consists of focusing solenoids with space charge compensation. Two-solenoid LEBTs are successfully used for high current (>100 mA) proton beam transport. Preservation of low emittances (~0.15 π mm-mrad) requires the addition of a heavy gas (Xe, Kr), which causes ~5% of proton loss in a 1 m long LEBT. Similar Xe densities would be required to preserve low emittances of H{sup −} beams, but such gas densities cause unacceptably high H{sup −} beam losses. A short LEBT with only one short solenoid, movable for RFQ matching, can be used for reduced negative ion stripping. A strong electrostatic-focusing LEBT has been successfully adopted for transport of high current H{sup −} beams in the SNS Front End. Some modifications of such electrostatic LEBTs are expected to improve the reliable transport of intense positive and negative ion beams without greatly degrading their low emittances. We concentrate on processes that determine the beam brightness degradation and on their prevention. Proposed improvements to the SNS electrostatic LEBT are discussed.

43 PARTICLE ACCELERATORS↗

Identification of the Elusive Methyl-Loss Channel in the Crossed Molecular Beam Study of Gas-Phase Reaction of Dicarbon Molecules (C 2 ; X 1 Σ g + /a 3 Π u ) with 2-Methyl-1,3-butadiene (C 5 H 8 ; X 1 A')

The crossed molecular beams technique was utilized to explore the reaction of dicarbon C 2 (X 1 Σ g + /a 3 Π u ) with 2-methyl-1,3-butadiene (isoprene, CH 2 C(CH 3 )CHCH 2 ; X 1 A') at a collision energy of 28 ± 1 kJ mol⁻¹ using a supersonic dicarbon beam generated via photolysis (248 nm) of helium-seeded tetrachloroethylene (C 2 Cl 4 ). Here, experimental data combined with previous ab initio calculations provide evidence of the detection of the hitherto elusive methyl elimination channels leading to acyclic resonantly stabilized hexatetraenyl radicals: 1,2,4,5-hexatetraen-3-yl (CH 2 CC•CHCCH 2 ) and/or 1,3,4,5-hexatetraen-3-yl (CH 2 CHC•CCCH 2 ). These pathways are exclusive to the singlet potential energy surface, with the reaction initiated by the barrierless addition of dicarbon to one of the carbon-carbon double bonds in the diene. In combustion systems, both hexatetraenyl radicals can isomerize to the phenyl radical (C 6 H 5 ) through a hydrogen atom assisted isomerization – the crucial reaction intermediate and molecular mass growth species step toward the formation of polycyclic aromatic hydrocarbons (PAHs) and soot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of the communications impact of a low power arcjet thruster

The interaction of a 1 kW arcjet thruster plume with a communications signal is evaluated. A two-parameter, source flow equation has been used to represent the far flow field distribution of the arcjet plume in a realistic spacecraft configuration. Modelling the plume as a plasma slab, the interaction of the plume with a 4 GHz communications signal is then evaluated in terms of signal attenuation and phase shift between transmitting and receiving antennas. Except for propagation paths which pass very near the arcjet source, the impacts to transmission appear to be negligible. The dominant signal loss mechanism is refraction of the beam rather than absorption losses due to collisions. However, significant reflection of the signal at the sharp vacuum-plasma boundary may also occur for propagation paths which pass near the source.

Carney, Lynnette M.↗