Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A short pulse (7 {mu}s FWHM) and high repetition rate (dc-5kHz) cantilever piezovalve for pulsed atomic and molecular beams

In this paper we report on the design and operation of a novel piezovalve for the production of short pulsed atomic or molecular beams. The high speed valve operates on the principle of a cantilever piezo. The only moving part, besides the cantilever piezo itself, is a very small O-ring that forms the vacuum seal. The valve can operate continuous (dc) and in pulsed mode with the same drive electronics. Pulsed operation has been tested at repetition frequencies up to 5 kHz. The static deflection of the cantilever, as mounted in the valve body, was measured as a function of driving field strength with a confocal microscope. The deflection and high speed dynamical response of the cantilever can be easily changed and optimized for a particular nozzle diameter or repetition rate by a simple adjustment of the free cantilever length. Pulsed molecular beams with a full width at half maximum pulse width as low as 7 {mu}s have been measured at a position 10 cm downstream of the nozzle exit. This represents a gas pulse with a length of only 10 mm making it well matched to for instance experiments using laser beams. Such a short pulse with 6 bar backing pressure behind a 150 {mu}m nozzle releases about 10{sup 16} particles/pulse and the beam brightness was estimated to be 4x10{sup 22} particles/(s str). The short pulses of the cantilever piezovalve result in a much reduced gas load in the vacuum system. We demonstrate operation of the pulsed valve with skimmer in a single vacuum chamber pumped by a 520 l/s turbomolecular pump maintaining a pressure of 5x10{sup -6} Torr, which is an excellent vacuum to have the strong and cold skimmed molecular beam interact with laser beams only 10 cm downstream of the nozzle to do velocity map slice imaging with a microchannel-plate imaging detector in a single chamber. The piezovalve produces cold and narrow ({Delta}v/v=2%-3%) velocity distributions of molecules seeded in helium or neon at modest backing pressures of only 6 bar. The low gas load of the cantilever valve makes it possible to design very compact single chamber molecular beam machines with high quality cold and intense supersonic beams. The high speed cantilever piezovalve may find broad applicability in experiments where short and strong gas pulses are needed with only modest pumping, the effective use of (expensive) samples, or the production of cold atomic and molecular beams.

43 PARTICLE ACCELERATORS↗

Recent operation status of Japan Proton Accelerator Research Complex H{sup -} ion source

A cesium-free H{sup -} ion source driven with a LaB{sub 6} filament is being operated at the Japan Proton Accelerator Research Complex for approximately three years without any serious trouble. In the beam commissioning or supply runs, the ion source has been operated in two different modes such as low current mode of 5 mA and high current mode of 30 mA. The total interruption time during the runs due to the ion source failure is approximately 50 h, which correspond to the ion source availability of 99%. After a long-term operation, the surface of the filament and the plasma electrode become discolored with dark partially. The result of surface analysis with field emission scanning electron microscope showed that most of the dark material is formed with boron. At the beam test performed in the interval of the run, we demonstrated that the H{sup -} current increased by miniaturizing the LaB{sub 6} filament.

43 PARTICLE ACCELERATORS↗

Recent results of the laser ion source facility at INFN-LNS and applications to nuclear and applied research

A pulsed neodymium-doped yttrium aluminum garnet laser ion source has been used as proton beams generator. The laser wavelength is 1064 nm, the pulse duration is 9 ns and the intensity reaches 10{sup 10} W/cm{sup 2}. Laser irradiates hydrogenated polymers targets located in a chamber at 10{sup -7} mbar. The ions are post-accelerated in a suitable chamber by 30 kV of voltage between the target, positively biased, and the following ground electrode. The extracted beams is characterized through a time-of-flight technique. Possible applications to the field of nuclear physics, such as nuclear excitation and de-excitations, nuclear reactions and nuclear fusion, will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Portable emittance measurement device

In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.

43 PARTICLE ACCELERATORS↗

The third generation superconducting 28 GHz electron cyclotron resonance ion source VENUS (invited)

VENUS is a third generation electron cyclotron resonance (ECR) ion source, which incorporates a high field superconducting NbTi magnet structure, a 28 GHz gryotron microwave source and a state of the art closed cycle cryosystem. During the decade from initial concept to regular operation, it has demonstrated both the feasibility and the performance levels of this new generation of ECR ion sources and required innovation on magnet construction, plasma chamber design, and beam transport. In this paper, the development, performance, and major innovations are described as well as a look to the potential to construct a fourth generation ECR ion source.

43 PARTICLE ACCELERATORS↗

Enhancement in ion beam current with layered-glows in a constricted dc plasma ion source

High current mode has been discovered and investigated in a constricted dc plasma ion source. As discharge currents exceed a certain threshold, voltage to sustain the constricted dc plasma suddenly falls down to almost half of the value. In this sense, constricted dc plasmas can be sustained at much higher current than in conventional mode operation at a fixed discharge voltage. Phenomenally, several discrete layered-glows are created between an anode glow and a cathode glow. The layers are thin and divided by dark spaces where charged particles can be accelerated. In this high current mode, ion beam current density is about 100 times higher than in conventional mode at the same voltage. It is noteworthy that lower gas pressure is desirable to sustain the layered-glow mode, which is also profitable for ion source in terms of differential pumping. Ion current density exceeds 300 mA/cm{sup 2} at low discharge power of 175 W where ion density of plasma ball is estimated to be over 3.7x10{sup 12} cm{sup -3}.

43 PARTICLE ACCELERATORS↗

Emittance estimation by an ion optical element with variable focusing strength and a viewing target

The emittance of an extracted ion beam can be estimated to first order by a series of three linear independent profile measurements. This estimation is restricted to the evaluation of an upper limit of the emittance value for a homogeneous, nonfilamented beam. The beam is assumed to be round, respectively elliptical, without any structure of the intensity distribution, no space charge has been assumed for the drifting beam, and the optics is assumed to be linear. Instead of using three different drift sections, a linear focusing element with three different focusing strengths can be used. Plotting the beam radius as function of focusing strength, three independent solutions can be used to calculate the Twiss parameters {alpha}, {beta}, and {gamma} and furthermore the emittance {epsilon}. Here we describe the measurements which have been performed with the SECRAL ion source at Institute of Modern Physics Lanzhou.

43 PARTICLE ACCELERATORS↗

New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)

Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e {mu}A of {sup 129}Xe{sup 43+}, 22 e {mu}A of {sup 209}Bi{sup 41+}, and 1.5 e {mu}A of {sup 209}Bi{sup 50+}. To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e {mu}A of {sup 129}Xe{sup 27+} and 152 e {mu}A of {sup 129}Xe{sup 30+}, although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and {sup 129}Xe{sup 27+}, {sup 78}Kr{sup 19+}, {sup 209}Bi{sup 31+}, and {sup 58}Ni{sup 19+} beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.

43 PARTICLE ACCELERATORS↗

Investigations of the emittance and brightness of ion beams from an electron beam ion source of the Dresden EBIS type

We have characterized ion beams extracted from the Dresden EBIS-A, a compact room-temperature electron beam ion source (EBIS) with a permanent magnet system for electron beam compression, using a pepper-pot emittance meter. The EBIS-A is the precursor to the Dresden EBIS-SC in which the permanent magnets have been replaced by superconducting solenoids for the use of the source in high-ion-current applications such as heavy-ion cancer therapy. Beam emittance and brightness values were calculated from data sets acquired for a variety of source parameters, in leaky as well as pulsed ion extraction mode. With box shaped pulses of C{sup 4+} ions at an energy of 39 keV root mean square emittances of 1-4 mm mrad and a brightness of 10 nA mm{sup -2} mrad{sup -2} were achieved. The results meet the expectations for high quality ion beams generated by an electron beam ion source.

43 PARTICLE ACCELERATORS↗

High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

43 PARTICLE ACCELERATORS↗

Gallium ion extraction from a plasma sputter-type ion source

A broad mixed ion beam containing positive ions of gallium (Ga) was produced with a plasma sputter-type ion source. Liquid Ga was suspended on a tungsten reservoir to be sputtered and postionized in argon (Ar) plasma excited by a radio frequency (rf) power at 13.56 MHz. Optical emission spectra from the plasma near the Ga sputtering target had indicated that the release of Ga into plasma increased with increasing negative bias to the sputtering target. The ratio of Ga{sup +} current to Ar{sup +} current was measured to be about 1% with a quadrupole mass analyzer at 100 V extraction voltage for incident rf power as low as 30 W. Ions in the plasma were extracted through a pair of multiaperture electrodes. The homogeneity of Ga flux was examined by making a Ga deposition pattern on a glass substrate located behind the extractor electrodes.

43 PARTICLE ACCELERATORS↗

Response-time improved hydrothermal-method-grown ZnO scintillator for soft x-ray free-electron laser timing-observation

For pump and probe experiments in x-ray free-electron laser (XFEL) facilities, accurate timing synchronization between short-wavelength femtosecond pulses from XFELs and short optical pulses from other light sources is required. For this purpose, the response time of a hydrothermal-method-grown ZnO is improved by over one order of magnitude via intentional iron ion doping. The fluorescence rise- and decay-time constants are measured to be less than 10 and 100 ps, respectively. Owing to its intense fluorescence even for single pulse XFEL excitation, the timing jitter of the soft x-ray pulse and timing electronics are evaluated to be less than 70 ps.

43 PARTICLE ACCELERATORS↗

High Power Operation of the THz FEL at ISIR, Osaka University

The free-electron laser based on the L-band electron linac is under development to generate high power radiation in the THz region. Recent results of the development are presented, including the wavelength spectra and the output power vs. wavelength from 25 to 110 {mu}m.

43 PARTICLE ACCELERATORS↗

Performance of the AILES THz-Infrared beamline at SOLEIL for High resolution spectroscopy

The new THz beamline (AILES) located at the third generation Synchrotron Radiation source SOLEIL is now operating for applications in a wide variety of research themes. In particular, this source with its adapted optics allows high resolution spectroscopic measurements of molecules in the entire infrared and THz range. This presentation focuses on the performances concerning flux, spectral range and stability for molecular spectroscopy. Thanks to these performances, the coupling of synchrotron radiation from a highly stable third generation source with high resolution FTIR spectrometer and with a long path cell (150 m or more) can be particularly advantageous. This fact is related to the optics of the beamline permitting the entire source to be used without aperture stop (entrance iris), even for measurements at highest-resolution of approx0.1 mueV (10{sup -3} cm{sup -1}).

43 PARTICLE ACCELERATORS↗

Development of a multipurpose vacuum chamber for serial optical and diffraction experiments with free electron laser radiation

In this paper we present a development of a multipurpose vacuum chamber which primal function is to be used in pump/probe experiments with free electron laser (FEL) radiation. The chamber is constructed for serial diffraction and serial spectroscopy allowing a fast exchange of samples during the measurement process. For the fast exchange of samples, liquid jet systems are used. Both applications, utilizing soft x-ray FEL pulses as pump and optical laser pulses as probe and vice versa are documented. Experiments with solid samples as well as the liquid jet samples are presented. When working with liquid jets, a system of automatically refilled liquid traps for capturing liquids has been developed in order to ensure stable vacuum conditions. Differential pumping stages are placed in between the FEL beamline and the experimental chamber so that working pressure in the chamber can be up to four orders of magnitude higher than the pressure in the FEL beamline.

43 PARTICLE ACCELERATORS↗

Elementary Ion Optics with Applications to Electromagnetic Spectrometers

This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

43 PARTICLE ACCELERATORS↗

Absolute calibration of LIDAR Thomson scattering systems by rotational Raman scattering

Absolute calibration of LIDAR Thomson scattering systems on large fusion devices may be achieved using rotational Raman scattering. The choice of calibrating gas molecule presents different options and design trade-offs and is likely to be strongly dependent on the laser wavelength selected. Raman scattering of hydrogenic molecules produces a very broad spectrum, however, with far fewer scattered photons than scattering from nitrogen or oxygen at the same gas pressure. Lower laser wavelengths have the advantage that the Raman cross section increases, {sigma}{sub Raman}{proportional_to}1/{lambda}{sub 0}{sup 4}, but the disadvantage that the spectral width of the scattered spectrum decreases, {Delta}{lambda}{sub Raman}{proportional_to}{lambda}{sub 0}{sup 2}. This narrower spectrum makes measurement closer to the laser wavelength necessary. The design of the calibration technique presents a number of challenges. Some of these challenges are generic to all Thomson scattering systems. These include detecting a sufficient number of photoelectrons and designing filters that measure close to the laser wavelength while simultaneously achieving adequate blocking of the laser wavelength. An issue specific to LIDAR systems arises since the collection optics operates over a wide range of depth of field. This wide depth of field has the effect of changing the angle of light incident on the optical interference filter with plasma major radius. The angular distribution then determines the effective spectral transmission function of the interference filter and hence impacts on the accuracy of the absolute calibration. One method that can be used to increase absolute calibration accuracy is collecting both Stokes and anti-Stokes lines with optical filter transmission bands specifically designed to reduce systematic uncertainty.

43 PARTICLE ACCELERATORS↗

The extreme ultraviolet split and femtosecond delay unit at the plane grating monochromator beamline PG2 at FLASH

An extreme ultraviolet split and femtosecond delay unit based on grazing incidence Mach-Zehnder geometry has been designed and implemented on the plane grating monochromator beamline PG2 at FLASH, the Free Electron Laser at DESY. This device splits the FLASH radiation into two beams, which can independently be steered, filtered and temporally delayed between -5.1 and +5.1 ps with uncertainty in the temporal accuracy of 210 as. To demonstrate the performance of this device, we have performed longitudinal coherence studies of FLASH radiation as well as measured the pulse length by nonlinear two-photon double-ionization in helium.

43 PARTICLE ACCELERATORS↗