An overview of how parity-violating electron scattering experiments are performed at CEBAF

Parity-violating electron-scattering experiments represent an important focus of the nuclear physics experimental program at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. These experiments pose significant challenges because the scattering asymmetries can be very small, of the order parts-per-million and smaller. To succeed, the properties of the electron beam such as current, position, size and energy, must be very nearly identical in the two electron-polarization spin states (parallel and anti-parallel relative to the direction of beam motion at the scattering target). This paper describes the origins of unwanted helicity-correlated beam asymmetries present on the electron beam and methods to minimize them to acceptable levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflections

Flash radiography is a much used diagnostic technique for high-explosively driven hydrodynamic experiments. Two linear-induction electron accelerators (LIAs) at the Los Alamos Dual Axis Radiography of Hydrodynamic Tests (DARHT) facility provide the source spots for point projection radiography of exceptionally large and dense experiments. In these LIAs, the beam acceleration is provided by high-voltage pulses applied to a number of inductively isolated gaps. The high-voltage pulses are produced by remotely located pulsedpower generators and delivered to the gaps by long highvoltage cables. For Scorpius, these pulse generators are called line replacement units (LRUs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic hydrogen-cyclotron wave emission below the hydrogen-cyclotron frequency in the auroral acceleration region

A mechanism is suggested for the excitation of electrostatic ion-cyclotron waves at frequencies below the ion-cyclotron frequency in the midst of the auroral acceleration region, which is assumed to consist of downward moving double layers. The mechanism involves upward flowing ions interacting with a downward flowing background plasma. The upward flowing ions are the ion beams accelerated by the double layer. The downward motion of the background plasma corresponds to a plasma expansion into the density cavity that develops in connection with double layer formation in the acceleration region. The ion-cyclotron waves excited by the counterstreaming flows are doppler shifted to frequencies below the harmonics of the ion cyclotron frequency. It is suggested that such wave emissions could account for some very narrow-banded waves at frequencies below the hydrogen cyclotron frequency that were observed by the S3-3 satellite.

Singh, N.↗

Development of a Positron Source for JLab at the IAC

We report on the research performed towards the development of a positron sour for Jefferson Lab's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, VA. The first year of work was used to benchmark the predictions of our current simulation with positron production efficiency measurements at the IAC. The second year used the benchmarked simulation to design a beam line configuration which optimized positron production efficiency while minimizing radioactive waste as well as design and construct a positron converter target. The final year quantified the performance of the positron source. This joint research and development project brought together the experiences of both electron accelerator facilities. Our intention is to use the project as a spring board towards developing a program of accelerator based research and education which will train students to meet the needs of both facilities as well as provide a pool of trained scientists.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector development for Jefferson Lab's 12GeV Upgrade

Jefferson Lab will soon finish its highly anticipated 12 GeV Upgrade. With doubled maximum energy, Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new experimental program with substantial discovery potential, addressing important topics in nuclear, hadronic and electroweak physics. In order to take full advantage of the high energy, high luminosity beam, new detectors are being developed, designed and constructed to fit the needs of different physics topics. The paper will give an overview of various new detector technologies to be used for 12 GeV experiments. It will then focus on the development of two solenoid-based spectrometers, the GlueX and SoLID spectrometers. The GlueX experiment in Hall D will study the complex properties of gluons through exotic hybrid meson spectroscopy. The GlueX spectrometer, a hermetic detector package designed for spectroscopy and the associated partial wave analysis, is currently in the final stage of construction. Hall A, on the other hand, is developing the SoLID spectrometer to capture the 3D image of the nucleon from semi-inclusive processes and to study the intrinsic properties of quarks through mirror symmetry breaking. Such a spectrometer will have the capability to handle very high event rates while still maintaining a large acceptance in the forward region.

43 PARTICLE ACCELERATORS↗

Polarization observables 𝑇 and 𝐹 in the 𝛾⁢𝑝→𝜋 0 ⁢𝑝 reaction at CLAS

Pion photoproduction in the $\vec{γ}$$\vec{p}$ → π 0 p reaction has been measured in the FROzen Spin Target (FROST) experiment at the Thomas Jefferson National Accelerator Facility. In this experiment, circularly polarized photons with energies up to 3.082 GeV impinged on a transversely polarized frozen-spin target. Final-state protons were detected in the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer. The polarization observables T and F have been extracted for W from 1445 to 2525 MeV, of which the energy range is much broader, and the precision is better than the existing measurements in higher W ranges. The data generally agree with predictions of present partial-wave analyses but also show marked differences for higher W ranges. By incorporating the present data into the databases, the Scattering Analysis Interactive Data (SAID) fits have been improved with relatively small χ 2 and significant changes in the parameters of the (1910)1/2 + and N(2190)7/2 − have been found with the JüBo model.

particle production↗

Deeply Virtual Compton Scattering at Hall A, Jefferson Lab

The Standard Model of particle physics de?nes quarks and leptons as the basic building blocks of all matter. The interaction between them are mediated by force carrying gauge bosons. Quantum Chromo Dynamics (QCD), the theory that explains the strong interaction is still not complete enough to derive the physical observables of a Quark-Gluon system from the fundamental degrees of freedom of its constituents. Experimentally observable single particle densities provide important insights into our understanding of the quark-gluon system and hence help fill in the gaps of QCD. Generalized Parton Distributions (GPDs) provide simultaneous information of both spacial and longitudinal momentum distributions of constituents of a quark-gluon system. Deeply Virtual Compton Scattering (DVCS) is understood to be the simplest and cleanest process to access GPDs. Even though the exclusive DVCS is simple to understand, the experimental process however, is complex with the Bethe-Heitler and e + p ? e + ? + N? being in the mix of the electron proton scattering e+p ? e+?+X. Over the years, 3 generations of DVCS experiments have been conducted in the Experimental Hall-A of Thomas Jefferson National Accelerator Facility (JLab). This thesis presents the extraction of DVCS cross section in 9 total kinematic points from the 3rd generation experiment (DVCS3) conducted after the 12 GeV upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) of JLab during Fall 2014 - Fall 2016.

Hashir Rashad, Mohamed Nuhman↗

High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems related to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization preservation and control in a figure-8 ring

We present a complete scheme for managing the polarization of ion beams in Jefferson Lab's proposed Medium-energy Electron-Ion Collider (MEIC). It provides preservation of the ion polarization during all stages of beam acceleration and polarization control in the collider's experimental straights. We discuss characteristic features of the spin motion in accelerators with Siberian snakes and in accelerators of figure-8 shape. We propose 3D spin rotators for polarization control in the MEIC ion collider ring. We provide polarization calculations in the collider with the 3D rotator for deuteron and proton beams. The main polarization control features of the figure-8 design are summarized.

Derbenev, Yaroslav S.↗

Evaluation of a High-Power Target Design for Positron Production at CEBAF

A source for polarized positron beams at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is being designed. The Polarized Electrons for Polarized Positrons (PEPPo) concept is used to produce polarized e$^+$e$^-$-pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. The scheme under consideration includes a 4 mm thick tungsten target that absorbs 17 kW deposited by a 1 mA continuous-wave electron beam with an energy of 120 MeV. The concept of a rotating tungsten rim mounted on a water-cooled copper disk was explored. The results of ANSYS thermal and mechanical analyses are discussed together with FLUKA evaluations of the radiation damages.

Ushakov, A.↗

Evaluation of a High-Power Target Design for Positron Production at CEBAF

A source for polarized positron beams at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is being designed. The Polarized Electrons for Polarized Positrons (PEPPo) concept is used to produce polarized e$^+$e$^-$-pairs from the bremsstrahlung radiation of a longitudinally polarized electron beam interacting within a high-Z conversion target. The scheme under consideration includes a 4 mm thick tungsten target that absorbs 17 kW deposited by a 1 mA continuous-wave electron beam with an energy of 120 MeV. The concept of a rotating tungsten rim mounted on a water-cooled copper disk was explored. The results of ANSYS thermal and mechanical analyses are discussed together with FLUKA evaluations of the radiation damages.

Ushakov, A.↗

Radioisotope replacement with compact electron linear accelerators

The replacement of radioactive sources with alternative technologies has been identified as a priority by international authorities, due to the risk of accidents and diversion by terrorists for use in Radiological Dispersal Devices. Many of these sources can be replaced with the X-rays produced by electron beams accelerated to MeV energies. However, the size, weight and costs of electron linacs must be significantly reduced to be considered for radioisotope replacement. RadiaBeam Technologies, LLC is developing a series of inexpensive compact electron accelerators in the 1–10 MeV range for radioisotope replacement such as Ir-192, Cs-137 and Co-60 for various applications. The dramatic level of miniaturization and cost-reduction was achieved thanks to the implementation of such innovative technologies as high-frequency magnetrons, split accelerating structure fabrication technology and solid-state Marx modulators. Here, in this paper, we overview RadiaBeam's compact linac developments, discuss the enabling technologies, and report on the current progress.

43 PARTICLE ACCELERATORS↗

Automating Anomaly Detection for Target systems at Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, produces the world’s most intense pulse neutrons beams. An accelerated proton beam is directed into a mercury target to generate neutrons via spallation. The target system accounted for over 40% of the overall downtime of the facility in 2022. Thus, early detection in anomalies in the target systems can enable taking corrective actions to avoid failures and reduce downtime. Fault prognostics and anomaly detection in accelerators, both at SNS and outside, has largely focused on the beam side. This paper presents one the first studies exploring leveraging machine learning to automate the detection of anomalies in the target system. The target system consists of over 30 different interconnected subsystems, and the present work focuses on the mercury process system as a use case. Analyzing data from 28 process variables from 2022 and 2023, tree-based and reconstruction-based algorithms are employed to detect anomalies in archived data. The algorithms detected previously unreported anomalies, several of which were deemed alert worthy by human experts, particularly those found by reconstruction-based algorithms. Using data from each production run in the accelerator increased the generalizability of the models in time. Efforts are now underway to implement a workflow for incorporating human feedback to update the models and evaluating performance on unseen data. The models will eventually be integrated into the existing System Tracking and Reliability system with a web interface for automated anomaly detection and reporting along with a pathway for incorporating human feedback for model updates.

Raj, Anant [ORNL] (ORCID:0000000306711244)↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Probing Proton Spin Structure: A Measurement of g 2 at Four-momentum Transfer of 2 to 6 GeV 2

The Spin Asymmetries of the Nucleon Experiment investigated the spin structure of the proton via inclusive electron scattering at the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory in Newport News, VA. A double-polarization measurement of polarized asymmetries was performed using the University of Virginia solid polarized ammonia target with target polarization aligned longitudinal and near transverse to the electron beam, allowing the extraction of the spin asymmetries A 1 and A 2 , and spin structure functions g 1 and g 2 . Polarized electrons of energies of 4.7 and 5.9 GeV were scattered to be viewed by a novel, non-magnetic array of detectors observing a four-momentum transfer range of 2 to 6 GeV 2 . This document addresses the extraction of the spin asymmetries and spin structure functions, with a focus on spin structure function g 2 , which we have measured as a function of x and W in four Q 2 bins.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam correction for multi-pass arcs in FFA@CEBAF: status update

This work examines the multi-pass steering of six electron beams in an FFA arc ranging from approximately 10.5 GeV to 22 GeV. Shown here is an algorithm based on singular value decomposition (SVD) to successfully steer all six beams through the arc given precise knowledge of all beam positions at each of one hundred and one diagnostic locations with one hundred individual corrector magnets: that is successive application of SVD to different 100 × 101 response matrices—one for each beam energy. Further, a machine learning scheme is developed which only requires knowledge of the energy-averaged beam position at each location to provide equivalent steering. Extension of this scheme to other beam optics quantities as well as transverse and longitudinal coupling is explored.

Accelerator Physics↗

Final Conversion of the Spallation Neutron Source Extraction Kicker Pulse Forming Network to a High Voltage Solid-State Switch

The Spallation Neutron Source (SNS) extraction kicker 60Hz pulsed system uses 14 Blumlein pulse-forming network (PFN) modulators that require timing synchronization with stable rise times. A replacement design has been investigated and the kickers have been converted over to use a solid-state switch design, eliminating the lifetime and stability issues associated with thyratrons and subsequent maintenance costs. All kickers have been converted, preventing thyratron jitter from impacting the beam performance and allowing higher-precision target impact. This paper discusses the completion of the conversion of the high-voltage switch from a thyratron to a solid-state switch with improved stability of the extraction system and associated accelerator beam stability.

Morris, B↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗