Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablatives Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The Ablation and Oxidation Behaviors of SiC Coatings on Graphite Prepared by Slurry Sintering and Pack Cementation

SiC coatings were generated on graphite using slurry sintering (SS) and pack cementation (PC). The samples’ ablation features were assessed by an oxyacetylene torch. The rates of mass ablation of the PC–SiC and SS–SiC coatings were approximated 2.17 × 10{sup −3} and 9.52 × 10{sup −3} g s{sup −1}, respectively, decreased by 84.1 and 29.6% compared to the uncoated samples. It was mainly attributed to the formation of a SiO{sub 2} layer on the surface. The continuous SiO{sub 2} molten film formed via the PC–SiC oxidation generates a sealing mechanism which can be an obstacle against the oxygen diffusion and hinder more ablation. This is while discontinuous SiO{sub 2} film formed from the thin SS–SiC cannot protect the graphite effectively. The non-isothermal oxidation test shows that without the SiC coating, the sample weight is lost largely from 25 to 1500 °C, and its weight loss was 2.2% after the TGA. However, after coating, the samples possessed excellent oxidation protection and weight losses of SS–SiC and PC–SiC coatings are down to 1.3 and 0.6%, respectively. The more oxidation of the graphite substrate occurred due to the formation of macrocracks in the coating during the TGA and also the formation of holes on SiO{sub 2} glass layer owing to release of CO or CO{sub 2}.

36 MATERIALS SCIENCE↗

Experimental investigation of the pulsed electrothermal (PET) thruster

Burton et al. (1982) have discussed the theory of the Pulsed Electrothermal (PET) thruster, a device which in principle can operate with 70 percent efficiency at a specific impulse of 1000 seconds and higher. It is pointed out that this level of performance would be particularly attractive for orbit raising of large satellites and other near-earth missions, which cannot be easily accomplished by chemical propulsion. The present investigation is concerned with two PET thruster operating modes. A PET thruster was built and tested on a thrust stand. Exhaust velocities for polyethylene propellant vary from 20 to 27 km/sec. Single pulse specific impulse and efficiency measurements based on ablated mass show a thruster efficiency of 37-56 percent in the time range from 1000 to 1750 seconds. It is believed that an improved design with a thruster efficiency in the range from 70 to 80 percent might be possible.

Burton, R. L.↗

Concentrating Antarctic Meteorites on Blue ice Fields: The Frontier Mountain Meteorite Trap

The collection of meteorites in Antarctica has greatly stimulated advancement in the field of meteoritics by providing the community with significant numbers of rare and unique meteorites types and by yielding large numbers of meteorites that sample older infall epochs (Grady et al., 1998). The majority of Antarctic meteorites are found on blue ice fields, where they are thought to be concentrated by wind and glacial drift (cf. Cassidy et al., 1992). The basic "ice flow model" describes the concentration of meteorites by the stagnation or slowing of ice as it moves against a barrier located in a zone with low snow accumulation. However, our limited knowledge of the details of the actual concentration mechanisms prevents establishing firm conclusions concerning the past meteorite flux from the Antarctic record (Zolensky, 1998). The terrestrial ages of Antarctic meteorites indicate that their concentration occurs on time scales of tens to hundreds of thousands of years (Nishiizumi et al., 1989). It is a challenge to measure a mechanism that operates so slowly, and since such time scales can span more than one glacial epoch one cannot assume that the snow accumulation rates, ice velocities and directions, etc. that are measured today are representative of those extant over the age of the trap. Testing the basic "ice flow model" therefore requires the careful measurement of meteorite locations, glacialogical ice flow data, ice thicknesses, bedrock and surface topology, ice ablation and snow accumulation rates, and mass transport by wind over an extended period of time in a location where these quantities can be interpreted in the context of past glacialogical history.

Sandford, Scott A.↗

Effects of Nonequilibrium Chemistry and Darcy-Forchheimer Pyrolysis Flow for Charring Ablator

The fully implicit ablation and thermal response code simulates pyrolysis and ablation of thermal protection materials and systems. The governing equations, which include energy conservation, a three-component decomposition model, and a surface energy balance, are solved with a moving grid.This work describes new modeling capabilities that are added to a special version of code. These capabilities include a time-dependent pyrolysis gas flow momentum equation with Darcy-Forchheimer terms and pyrolysis gas species conservation equations with finite rate homogeneous chemical reactions. The total energy conservation equation is also enhanced for consistency with these new additions. Two groups of parametric studies of the phenolic impregnated carbon ablator are performed. In the first group, an Orion flight environment for a proposed lunar-return trajectory is considered. In the second group, various test conditions for arcjet models are examined. The central focus of these parametric studies is to understand the effect of pyrolysis gas momentum transfer on material in-depth thermal responses with finite-rate, equilibrium, or frozen homogeneous gas chemistry. Results indicate that the presence of chemical nonequilibrium pyrolysis gas flow does not significantly alter the in-depth thermal response performance predicted using the chemical equilibrium gas model.

Chen, Yih-Kanq↗

3D-MAT Multi-rate Thermal Expansion and Restrained Thermal Growth

In an effort to characterize 3D Multifunctional Ablative Thermal Protection System (3D-MAT), a quartz fiber / cyanate ester composite for NASA’s Orion Multipurpose Crew Vehicle, Southern Research carried out multiple test efforts. Southern Research evaluated the coefficient of free thermal expansion at multiple heating rates in the X, Y and Z directions. To further understand the results, we further evaluated the material via Restrained Thermal Growth (RTG) in the X direction. The RTG test series involved testing via multiple procedures, resulting in an iterative process and a final conclusion.

Jay D Feldman↗

Real-Time Inhibitor Recession Measurements in the Space Shuttle Reusable Solid Rocket Motors

Real-time char line recession measurements were made on propellant inhibitors of the Space Shuttle Reusable Solid Rocket Motor (RSRM). The RSRM FSM-8 static test motor propellant inhibitors (composed of a rubber insulation material) were successfully instrumented with eroding potentiometers and thermocouples. The data was used to establish inhibitor recession versus time relationships. Normally, pre-fire and post-fire insulation thickness measurements establish the thermal performance of an ablating insulation material. However, post-fire inhibitor decomposition and recession measurements are complicated by the fact that most of the inhibitor is back during motor operation. It is therefore a difficult task to evaluate the thermal protection offered by the inhibitor material. Real-time measurements would help this task. The instrumentation program for this static test motor marks the first time that real-time inhibitors. This report presents that data for the center and aft field joint forward facing inhibitors. The data was primarily used to measure char line recession of the forward face of the inhibitors which provides inhibitor thickness reduction versus time data. The data was also used to estimate the inhibitor height versus time relationship during motor operation.

McWhorter, Bruce B.↗

Isolating and quantifying cross-beam energy transfer in direct-drive implosions on OMEGA and the National Ignition Facility

The angularly resolved mass ablation rates and ablation-front trajectories for Si-coated CH targets were measured in direct-drive inertial confinement fusion experiments to quantify cross-beam energy transfer (CBET) while constraining the hydrodynamic coupling. A polar-direct-drive laser configuration, where the equatorial laser beams were dropped and the polar beams were repointed from a symmetric direct-drive configuration, was used to limit CBET at the pole while allowing it to persist at the equator. The combination of low- and high-CBET conditions observed in the same implosion allowed for the effects of CBET on the ablation rate and ablation pressure to be determined. Hydrodynamic simulations performed without CBET agreed with the measured ablation rate and ablation-front trajectory at the pole of the target, confirming that the CBET effects on the pole are small. The simulated mass ablation rates and ablation-front trajectories were in excellent agreement with the measurements at all angles when a CBET model based on Randall's equations [C. J. Randall et al., Phys. Fluids 24, 1474 (1981)] was included into the simulations with a multiplier on the CBET gain factor. These measurements were performed on OMEGA and at the National Ignition Facility to access a wide range of plasma conditions, laser intensities, and laser beam geometries. The presence of the CBET gain multiplier required to match the data in all of the configurations tested suggests that additional physics effects, such as intensity variations caused by diffraction, polarization effects, or shortcomings of extending the 1-D Randall model to 3-D, should be explored to explain the differences in observed and predicted drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microelectromechanical Systems (MEMS) Broadband Light Source Developed

A miniature, low-power broadband light source has been developed for aerospace applications, including calibrating spectrometers and powering miniature optical sensors. The initial motivation for this research was based on flight tests of a Fabry-Perot fiberoptic temperature sensor system used to detect aircraft engine exhaust gas temperature. Although the feasibility of the sensor system was proven, the commercial light source optically powering the device was identified as a critical component requiring improvement. Problems with the light source included a long stabilization time (approximately 1 hr), a large amount of heat generation, and a large input electrical power (6.5 W). Thus, we developed a new light source to enable the use of broadband optical sensors in aerospace applications. Semiconductor chip-based light sources, such as lasers and light-emitting diodes, have a relatively narrow range of emission wavelengths in comparison to incandescent sources. Incandescent light sources emit broadband radiation from visible to infrared wavelengths; the intensity at each wavelength is determined by the filament temperature and the materials chosen for the filament and the lamp window. However, present commercial incandescent light sources are large in size and inefficient, requiring several watts of electrical power to obtain the desired optical power, and they emit a large percentage of the input power as heat that must be dissipated. The miniature light source, developed jointly by the NASA Glenn Research Center, the Jet Propulsion Laboratory, and the Lighting Innovations Institute, requires one-fifth the electrical input power of some commercial light sources, while providing similar output light power that is easily coupled to an optical fiber. Furthermore, it is small, rugged, and lightweight. Microfabrication technology was used to reduce the size, weight, power consumption, and potential cost-parameters critical to future aerospace applications. This chip-based light source has the potential for monolithic fabrication with on-chip drive electronics. Other uses for these light sources are in systems for vehicle navigation, remote sensing applications such as monitoring bridges for stress, calibration sources for spectrometers, light sources for space sensors, display lighting, addressable arrays, and industrial plant monitoring. Two methods for filament fabrication are being developed: wet-chemical etching and laser ablation. Both yield a 25-mm-thick tungsten spiral filament. The proof-of-concept filament shown was fabricated with the wet etch method. Then it was tested by heating it in a vacuum chamber using about 1.25 W of electrical power; it generated bright, blackbody radiation at approximately 2650 K. The filament was packaged in Glenn's clean-room facilities. This design uses three chips vacuum-sealed with glass tape. The bottom chip consists of a reflective film deposited on silicon, the middle chip contains a tungsten filament bonded to silicon, and the top layer is a transparent window. Lifetime testing on the package will begin shortly. The emitted optical power is expected to be approximately 1.0 W with the spectral peak at 1.1 mm.

Tuma, Margaret L.↗

Development of the C{sup 6+} laser ablation ion source for the KEK digital accelerator

A laser ion source that provides a fully ionized carbon ion beam is under joint development at the High Energy Accelerator Research Organization and Brookhaven National Laboratory. Long-pulse (6 ns) and short-pulse (500 ps) laser systems were tested by using them to irradiate a graphite target. Notable differences between the systems were observed in these experiments. Preliminary experimental results, such as the charge-state spectrum, beam intensity, and stability, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Ablation (MWA) for the Treatment of a Solitary, Chemorefractory Testicular Cancer Liver Metastasis

We present a case of a patient with stage IIIC metastatic seminoma with a persistent chemorefractory liver lesion. The patient was deemed a poor surgical candidate due to the tumor’s aggressive biology with numerous other liver lesions treated with chemotherapy and a relatively high probability for additional recurrences. Further chemotherapy with curative intent was not a feasible option due to the fact that the patient had already received second-line high-dose chemotherapy and four cycles of third-line treatment complicated by renal failure, refractory thrombocytopenia, and debilitating neuropathy. After initial failure of laser, microwave ablation of the chemorefractory liver metastasis resulted in prolonged local tumor control and rendered the patient disease-free for more than 35 months, allowing him to regain an improved quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relief Zones Enhance the Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) use ultrathin (≤15 μm-thick) polymer electrolyte membranes, susceptible to mechanical degradation from stress concentrations arising from device-level integration. Herein, relief zones were developed to mitigate mechanical degradation by alleviating excess and nonuniform compression across active areas. Relief zones, created through ablation of carbonaceous diffusion media, enable seamless adaptation across MEA dimensions without need for hardware modifications. Demonstrated using fuel cells as a case study, accelerated stress tests revealed a 6-fold lifetime improvement (∼1500 h) compared to conventional edge-protected MEAs, decoupling device-level engineering effects from material limitations.

accelerated stress test↗

A comparison of non-local electron transport models for laser-plasmas relevant to inertial confinement fusion

Here, we compare the reduced non-local electron transport model developed to Vlasov-Fokker-Planck simulations. Two new test cases are considered: the propagation of a heat wave through a high density region into a lower density gas, and a one-dimensional hohlraum ablation problem. We find that the reduced model reproduces the peak heat flux well in the ablation region but significantly over-predicts the coronal preheat. The suitability of the reduced model for computing non-local transport effects other than thermal conductivity is considered by comparing the computed distribution function to the Vlasov-Fokker-Planck distribution function. It is shown that even when the reduced model reproduces the correct heat flux, the distribution function is significantly different to the Vlasov-Fokker-Planck prediction. Two simple modifications are considered which improve agreement between models in the coronal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an On-board Failure Diagnostics and Prognostics System for Solid Rocket Booster

We develop a case breach model for the on-board fault diagnostics and prognostics system for subscale solid-rocket boosters (SRBs). The model development was motivated by recent ground firing tests, in which a deviation of measured time-traces from the predicted time-series was observed. A modified model takes into account the nozzle ablation, including the effect of roughness of the nozzle surface, the geometry of the fault, and erosion and burning of the walls of the hole in the metal case. The derived low-dimensional performance model (LDPM) of the fault can reproduce the observed time-series data very well. To verify the performance of the LDPM we build a FLUENT model of the case breach fault and demonstrate a good agreement between theoretical predictions based on the analytical solution of the model equations and the results of the FLUENT simulations. We then incorporate the derived LDPM into an inferential Bayesian framework and verify performance of the Bayesian algorithm for the diagnostics and prognostics of the case breach fault. It is shown that the obtained LDPM allows one to track parameters of the SRB during the flight in real time, to diagnose case breach fault, and to predict its values in the future. The application of the method to fault diagnostics and prognostics (FD&P) of other SRB faults modes is discussed.

Smelyanskiy, Vadim N.↗

NASA's Innovative Entry Systems and TPS Technologies Enabling Commercial Space Missions

For over six decades, the NASA Ames Entry Systems and Technology Division has been a cornerstone of U.S. space exploration, delivering critical atmospheric entry solutions since Project Mercury and now increasingly supporting the commercial space sector. The Division provides reliable entry system solutions through a unique blend of expertise, national facilities, and systems integration knowledge, a combination that is difficult to replicate outside a dedicated government entity. Consistently successful, the TS Division remains central to NASA’s exploration objectives and significantly contributes to the transfer of technology to the commercial space sector, supporting more than ten commercial space companies and supplying flight heatshields to three of them in the past five years. Its strengths in Thermal Protection System (TPS) materials, aerothermodynamics, ground test facilities, and Entry, Descent, and Landing (EDL) systems engineering drive rapid development and sustained U.S. competitiveness in space. The Division's expertise in reusable and ablative thermal protection systems, as well as mechanically deployable entry systems primarily developed for NASA missions, now benefits commercial space missions. This presentation will highlight the vision and needs of these commercial space companies, how NASA-invented technologies meet mission requirements, and how these technologies enable and distinguish their efforts.

Ethiraj Venkatapathy↗

Infrared Observations of the Orion Capsule During EFT-1 Hypersonic Reentry

High-resolution infrared observations of the Orion capsule during its atmospheric reentry on December 5, 2015 were made from a US Navy NP-3D. This aircraft, equipped with a long-range optical sensor system, tracked the capsule from Mach 10 to 7 from a distance of approximately 60 nmi. Global surface temperatures of the capsule's thermal heatshield were derived from near infrared intensity measurements. The global surface temperature measurements complemented onboard instrumentation and were invaluable to the interpretation of the in-depth thermocouple measurements which rely on inverse heat transfer methods and material response codes to infer the desired surface temperature from the sub-surface measurements. The full paper will address the motivations behind the NASA Engineering Safety Center sponsored observation and highlight premission planning processes with an emphasis on aircraft placement, optimal instrument configuration and sensor calibrations. Critical aspects of mission operations coordinated from the NASA Johnson Spaceflight Center and integration with the JSC Flight Test Management Office will be discussed. A summary of the imagery that was obtained and processed to global surface temperature will be presented. At the capsule's point of closest approach relative to the imaging system, the spatial resolution was estimated to be approximately 15-inches per pixel and was sufficient to identify localized temperature increases associated with compression pad support hardware on the heatshield. The full paper will discuss the synergy of the quantitative imagery derived temperature maps with in-situ thermocouple measurements. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented. The two complimentary measurements serve as an example of the effective leveraging of resources to advance the understanding of high Mach number environments associated with an ablated heatshield and provide unique data for the validation of design tools and numerical flight simulation techniques. Collaborative opportunities and technology investments in support of planned observations of NASA's next Orion flight test in 2018 will be explored in the full manuscript.

Horvath, Thomas J.↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Time-of-flight spectroscopy of the energy distribution of laser-ablated atoms and ions

The growth of ultrathin films, deposited by laser ablation, crucially depends on the energy of the ablated species. Therefore, a time-of-flight (TOF) spectrometer has been constructed and measurements have been carried out in order to determine the energy distribution of laser-ablated Fe and Pt atoms and ions in the plasma created by nanosecond pulses of a frequency-doubled neodymium doped yttrium aluminum garnet laser. The experiments have been performed in ultrahigh vacuum at relatively low laser power. For measuring the spectra of the neutrals, a cross-beam electron source for postionization and electric as well as magnetic fields for repelling the ions are employed. Nevertheless, measurements of neutral particles are restricted to low plasma densities due to electrostatic shielding within the plasma, leading to an inefficient deflection of charged particles by electrostatic and magnetic fields. Test measurements have been performed by utilizing the TOF spectrometer as a pressure gauge and also by chopping the electron beam, running the TOF spectrometer as a residual gas mass spectrometer. The spectra of the laser-ablated plasmas have shown plasma conditions with a Debye length of approximately 10{sup -4} m, densities of 10{sup 15}-10{sup 16} m{sup -3} and ion energies up to 150 eV. Neutral spectra have shown an unexpectedly low fraction of neutrals (10{sup -3}-10{sup -4}) and hyperthermal energies up to several 10 eV, possibly contributed by recombination of ions and electrons in the plasma. Even though gas spectra had demonstrated the expected sensitivity of the TOF spectrometer for low-energy neutrals, no thermally evaporated neutral atoms could be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗