Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Experimentally Measured Interfacial Area during Gas Injection into Saturated Porous Media: An Air Sparging Analogy

The amount of interfacial area (awn) between air and subsurface liquids during air-sparging can limit the rate of site remediation. Lateral movement within porous media could be encountered during air-sparging operations when air moves along the bottom of a low-permeability lens. This study was conducted to directly measure the amount of awn between air and water flowing within a bench-scale porous flow cell during the lateral movement of air along the upper edge of the cell during air injections into an initially water-saturated flow cell. Four different cell orientations were used to evaluate the effect of air injection rates and porous media geometries on the amount of awn between fluids. Air was injected at flow rates that varied by three orders of magnitude, and for each flow cellover this range of injection rates little change in awn was noted. A wider variation in awn was observed when air moved through different regions for the different flow cell orientations. These results are in good agreement with the experimental findings of Waduge et al. (2007), who performed experiments in a larger sand-pack flow cell, and determined that air-sparging efficiency is nearly independent of flow rate but highly dependent on the porous structure. By directly measuring the awn, and showing that awn does not vary greatly with changes in injection rate, we show that the lack of improvement to remediation rates is because there is a weak dependence of the awn on the air injection rate.

58 GEOSCIENCES↗

Open-air Demolition: Validation of EPA Approved Alternative Method for Emission Estimation - 19397

Emissions from open-air demolition of US Department of Energy (DOE) facilities are regulated by the US Environmental Protection Agency (EPA) under 40 CFR 61 subpart H. This regulation requires that facilities estimate emissions using an EPA approved method from activities such as open-air demolition prior to commencing the activity. Should those emissions exceed certain thresholds, the facility may be required to obtain an Approval to Construct or Modify the facility and/or installed monitoring methods meeting methods acceptable to EPA. There are no EPA approved methods that are specific to open-air demolition methods. For this project the DOE and CH2M Hill BWXT elected to prepare an alternative method specific to open-air demolition. EPA conditionally approved the method but required validation of the method during the demolition of the Vitrification Facility at the West Valley Demonstration Project (WVDP) before use for open-air demolition at other WVDP structures. The validation method included detailed source characterization, close-in ambient samplers, and a comparison of measured results to predicted emissions using AERMOD (American Meteorological Society (AMS) and U.S. Environmental Protection Agency (EPA) Regulatory Model). The methods evaluated include hydraulic hammers, mechanical shears, load out of waste and handling of the debris piles. The validation method involved the collection and analysis of ambient air samples from air samplers located at strategic locations within the projected plume path of the demolition activities. The analytical results from the air samplers were then compared to ambient air concentrations predicted at the sampler locations with the EPA model AERMOD. The input to the AERMOD software is a source term developed weekly using the alternative method and material at risk disturbed during each week. To account for the building wake effects of the surrounding structures, virtual point sources were developed in the AERMOD model and placed at the locations of the demolition, debris piles, debris handling and load out areas. It was found that the factors used for hydraulic hammering were extremely conservative and that emissions from the debris pile were not only the primary emission source, but that the moisture content of the debris pile and the wind speed were critical factors that must be considered in future open-air demolition projects. Based on the results of the validation process, adjustments were made to the alternative method. The final validated alternative method provides an approach for estimating airborne emissions from open-air demolition methods and techniques. The method will be used in lieu of 40 CFR 61 Appendix D to estimate emissions from future open-air demolition projects at the WVDP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $\$$50-$\$$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Air Velocity Distribution in Three Sizes of Commercial Broiler Houses During Tunnel Ventilation

Abstract. Convective cooling is a critical management strategy for maintaining an environment that promotes production efficiency, thermal comfort, and animal well-being in commercial broiler houses. Variations in house size, design, and equipment configuration contribute greatly to the air velocity distribution within the facility. This study assessed total airflow, air velocity distribution, and quantified the floor area in three facilities experiencing insufficient air velocity for maintenance of production efficiency, thermal comfort, and animal well-being. Test facility 1 was an 18.3 × 170.7 m solid side-wall broiler house, test facility 2 was a 15.24 × 144.8 m solid side-wall broiler house, and test facility 3 was a 12.19 × 121.9 m curtain side-wall broiler house. Total airflow of each facility, measured with a Fan Assessment and Numeration System, was 512,730, 389,495, and 329,270 m 3 h -1 for test facilities 1, 2, and 3, respectively. Air velocity distribution patterns were characterized in each house with a Scalable Environment Assessment System (SEAS) and spatial statistics. The air velocity distributions within the test facilities were variable, with notable maxima immediately downstream of the tunnel inlets, which serve as a well-defined vena contracta, and local minima near the leading end of the evaporative pads and the exhaust fans. Equipment within the facilities had an impact on the air velocity distribution by creating reduced cross-sectional areas that resulted in localized increases in air velocity. The percentage of total bird-level floor area in each facility experiencing air velocities below 1.5 m s -1 was 14.3%, 20.7%, and 10.0% for test facilities 1, 2, and 3, respectively. The effective design velocity (V ed ) was calculated from total airflow using the measured building cross-sectional area. The V ed measured 2.97, 2.45, and 2.34 m s -1 for test facilities 1, 2, and 3, respectively. Mean cross-sectional air velocity (V cs ) was calculated from SEAS data and normalized using each facility’s V ed to account for differences in building size for comparison. Test facility 1, the largest of the three houses, generated substantially higher V cs /V ed than test facilities 2 and 3. Test facilities 2 and 3 maintained a larger proportion of V cs above V ed than test facility 1. Test facility 1 showed 26.5% of the total house length below V ed , while test facilities 2 and 3 had only 20.8% and 17.5%, respectively, of the total house length below V ed . The lower-velocity regions were due to the length of the evaporative cooling pad inlet and the use of tunnel doors, and the exhaust fan placement on the side-walls in test facility 1 created an additional pronounced low-velocity area. Placement of tunnel ventilation fans on the end-wall of the facility, rather than the side-wall, eliminated the low-velocity region at the exhaust end of the facility. Modifications to current practices for broiler production facility construction and evaporative cooling pad inlet installation would be required to minimize the low-velocity region at the inlet end of these facilities. Consideration of house width and physical arrangement of the air inlets, tunnel fans, and internal equipment are critical for improving the uniformity of air velocity in commercial broiler houses. Keywords: Air velocity, Anemometer, Broiler house, FANS, Tunnel ventilation.

Agriculture↗

DUS II Soil Gas Sampling and Air Injection Test Results

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

54 ENVIRONMENTAL SCIENCES↗

Remote Sensing and Spatial Growth Modeling Coupled with Air Quality Modeling to Assess the Impact of Atlanta, Georgia on the Local and Regional Environment

The growth of cities, both in population and areal extent, appears as an inexorable process. Urbanization continues at a rapid rate, and it is estimated that by the year 2025, 80 percent of the world s population will live in cities. Directly aligned with the expansion of cities is urban sprawl. Urban expansion has profound impacts on a host of biophysical, environmental, and atmospheric processes. A reduction in air quality over cities is a major result of these impacts. Strategies that can be directly or indirectly implemented to help remediate air quality problems in cities and that can be accepted by political decision makers and the general public are now being explored to help bring down air pollutants and improve air quality. The urban landscape is inherently complex and this complexity is not adequately captured in air quality models, particularly the Community Multiscale Air Quality (CMAQ) model that is used to assess whether urban areas are in attainment of EPA air quality standards, primarily for ground level ozone. This inadequacy of the CMAQ model to sufficiently respond to the heterogeneous nature of the urban landscape can impact how well the model predicts ozone pollutant levels over metropolitan areas and ultimately, whether cities exceed EPA ozone air quality standards. We are exploring the utility of high-resolution remote sensing data and urban spatial growth modeling (SGM) projections as improved inputs to the meteorology component of the CMAQ model focusing on the Atlanta, Georgia metropolitan area as a case study. These growth projections include "business as usual" and "smart growth" scenarios out to 2030. The growth projections illustrate the effects of employing urban heat island mitigation strategies, such as increasing tree canopy and albedo across the Atlanta metro area, which in turn, are used to model how ozone and air temperature can potentially be moderated as impacts on elevating ground-level ozone, as opposed to not utilizing heat island mitigation strategies. The National Land Cover Dataset at 30m resolution is being used as the land use/land cover input and aggregated to the 4km scale for the MM5 mesoscale meteorological model and the (CMAQ) modeling schemes. Use of these data have been found to better characterize low density/suburban development as compared with USGS 1km land use/land cover data that have traditionally been used in modeling. Air quality prediction for future scenarios to 2030 is being facilitated by land use projections using a spatial growth model. Land use projections were developed using the 2030 Regional Transportation Plan developed by the Atlanta Regional Commission, the regional planning agency for the area. This allows the State Environmental Protection agency to evaluate how these transportation plans will affect future air quality. The coupled SGM and air quality modeling approach provides insight on what the impacts of Atlanta s growth will be on the local and regional environment and exists as a mechanism that can be used by policy makers to make rationale decisions on urban growth and sustainability for the metropolitan area in the future.

Quattrochi, Dale A.↗

An Investigation of the Icing and Heated-air De-icing Characteristics of the R-2600-13 Induction System

A laboratory investigation was made on a Holley 1685-HB carburetor mounted on an R-2600-13 supercharger assembly to determine the icing characteristics and the heated-air de-icing requirements of this portion of the B-25D airplane induction system. Icing has been found to be most prevalent at relatively small throttle openings and, consequently, all runs were made at simulated 60-percent normal rated power condition. Icing characteristics were determined during a series of 15-minute runs over a range of inlet-air conditions. For the de-icing investigation severe impact ice was allowed to form in the induction system and the time required for the recovery of 95 percent of the maximum possible air flow at the original throttle setting was then determined for a range of wet-bulb temperatures. Results of these runs showed that ice on the walls of the carburetor adapter and on the rim of the impeller-shroud portion of the supercharger diffuser plate did not affect engine operation at 60-percent normal rated power. Ice that adversely affected the air flow and the fuel-air ratio was formed only on the central web of the carburetor and then only when the inlet air was saturated or contained free moisture in excess of saturation. No serious ice formations were observed at inlet-air temperatures above 66 0 F or with an inlet-air enthalpy greater than 34 Btu per pound. The maximum temperature at. which any trace of icing could be detected was 1110 F with a relative humidity of approximately 28 percent, The air-flow recovery time for emergency de-icing was 0.3 minute for.an enthalpy of 35 Btu per pound or wet-bulb temperature of 68 0 F. Further increase in enthalpy and wet-bulb temperature above these values resulted in very slight improvement in recovery time. The fuel-air ratio restored by a 5-Minute application of heated air was approximately 7 percent less than the initial value for cold-air conditions.

Chapman, Gilbert E.↗

SpaceX Dragon Air Circulation System

The Dragon capsule is a reusable vehicle being developed by Space Exploration Technologies (SpaceX) that will provide commercial cargo transportation to the International Space Station (ISS). Dragon is designed to be a habitable module while it is berthed to ISS. As such, the Dragon Environmental Control System (ECS) consists of pressure control and pressure equalization, air sampling, fire detection, illumination, and an air circulation system. The air circulation system prevents pockets of stagnant air in Dragon that can be hazardous to the ISS crew. In addition, through the inter-module duct, the air circulation system provides fresh air from ISS into Dragon. To utilize the maximum volume of Dragon for cargo packaging, the Dragon ECS air circulation system is designed around cargo rack optimization. At the same time, the air circulation system is designed to meet the National Aeronautics Space Administration (NASA) inter-module and intra-module ventilation requirements and acoustic requirements. A flight like configuration of the Dragon capsule including the air circulation system was recently assembled for testing to assess the design for inter-module and intra-module ventilation and acoustics. The testing included the Dragon capsule, and flight configuration in the pressure section with cargo racks, lockers, all of the air circulation components, and acoustic treatment. The air circulation test was also used to verify the Computational Fluid Dynamics (CFD) model of the Dragon capsule. The CFD model included the same Dragon internal geometry that was assembled for the test. This paper will describe the Dragon air circulation system design which has been verified by testing the system and with CFD analysis.

Hernandez, Brenda↗

Assimilation of Quality Controlled AIRS Temperature Profiles using the NCEP GFS

We have previously conducted a number of data assimilation experiments using AIRS Version-5 quality controlled temperature profiles as a step toward finding an optimum balance of spatial coverage and sounding accuracy with regard to improving forecast skill. The data assimilation and forecast system we used was the Goddard Earth Observing System Model , Version-5 (GEOS-5) Data Assimilation System (DAS), which represents a combination of the NASA GEOS-5 forecast model with the National Centers for Environmental Prediction (NCEP) operational Grid Point Statistical Interpolation (GSI) global analysis scheme. All analyses and forecasts were run at a 0.5deg x 0.625deg spatial resolution. Data assimilation experiments were conducted in four different seasons, each in a different year. Three different sets of data assimilation experiments were run during each time period: Control; AIRS T(p); and AIRS Radiance. In the "Control" analysis, all the data used operationally by NCEP was assimilated, but no AIRS data was assimilated. Radiances from the Aqua AMSU-A instrument were also assimilated operationally by NCEP and are included in the "Control". The AIRS Radiance assimilation adds AIRS observed radiance observations for a select set of channels to the data set being assimilated, as done operationally by NCEP. In the AIRS T(p) assimilation, all information used in the Control was assimilated as well as Quality Controlled AIRS Version-5 temperature profiles, i.e., AIRS T(p) information was substituted for AIRS radiance information. The AIRS Version-5 temperature profiles were presented to the GSI analysis as rawinsonde profiles, assimilated down to a case-by-case appropriate pressure level p(sub best) determined using the Quality Control procedure. Version-5 also determines case-by-case, level-by-level error estimates of the temperature profiles, which were used as the uncertainty of each temperature measurement. These experiments using GEOS-5 have shown that forecasts resulting from analyses using the AIRS T(p) assimilation system were superior to those from the Radiance assimilation system, both with regard to global 7 day forecast skill and also the ability to predict storm tracks and intensity.

Susskind, Joel↗

Improving AIRS NRT Imagery for the Enhancement of Visualization Services in LANCE

The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of processing, archiving, and distribution services for data from the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002. AIRS provides data enabling global observations of the atmospheric state. The GES DISC provides service to both AIRS standard products and Near Real-time (NRT) products. The AIRS NRT product is one important element in the Land, Atmosphere Near real-time Capability for EOS (LANCE). The LANCE processing of the AIRS NRT product and the generation of the imagery are performed at the GES DISC. The AIRS NRT imagery are generated by mosaicking and mapping the available AIRS 6-minute retrieval granules to a global cylindrical projection. The images are constantly refreshed when new granules are produced. The AIRS NRT Viewer and LANCE Worldview provide visualization services to online users for AIRS NRT imagery. The imagery include atmospheric temperature, humidity, precipitation, Dust Score, CO, and SO2. The AIRS Applications Development Team at NASA JPL developed a new orbit-based algorithm and software to improve the AIRS NRT imagery. The GES DISC is collaborating with the AIRS Applications Development Team for the implementation of the new algorithm and software. The improvements include image quality, new color palettes, and variable changes. In this presentation, we will detail the improvements and demonstrate visualization of the new imagery.

Ding, Feng↗

Supporting Global Air Quality Management Needs With A Flexible Data Fusion Tool for Estimation and Forecasting in Google Earth Engine

High spatial and temporal resolution air quality estimation and forecasting can be enhanced by combining global data sources, like chemical transport models and satellite remote sensing, with local information from regulatory and low-cost air quality monitors. Successful integration of data from these diverse sources is complicated by many factors, however, including differences in spatial and temporal resolution, data availability and latency issues, varying data quality, and large computational and data storage requirements. This presentation will provide an overview of a NASA-funded effort to develop the foundation for future operationalization of air quality forecasting for world-wide end-users and integration into their air quality management decision processes, which will be achieved in future phases of this multi-year project. We will summarize our progress in developing a data fusion system using the Google Earth Engine platform which can integrate model, satellite, and surface-level monitoring datasets to enhance estimation and forecasting of air-quality-relevant pollutants at sub-daily and sub-city scales. The tool is being developed in close cooperation with several city- and regional-level air quality managers in the USA and around the world. Our end-goal is to provide these air quality managers with the information they need to assess and anticipate the impacts of poor air quality, track changes in air quality due to ongoing mitigation efforts and land use changes, and identify ways to improve their air quality monitoring strategies. This presentation will focus on recent advances achieved through the project, including integration of multiple air quality datasets in a prototype data fusion system in Google Earth Engine, the quantification of uncertainties associated with our data fusion approach, and the development of user interfaces and visualization tools to convey air quality information in a way which best meets end-user needs.

Carl Malings↗

Supporting Global Air Quality Management Needs With A Flexible Data Fusion Tool for Estimation and Forecasting in Google Earth Engine

High spatial and temporal resolution air quality estimation and forecasting can be enhanced by combining global data sources, like chemical transport models and satellite remote sensing, with local information from regulatory and low-cost air quality monitors. Successful integration of data from these diverse sources is complicated by many factors, however, including differences in spatial and temporal resolution, data availability and latency issues, varying data quality, and large computational and data storage requirements. This presentation will provide an overview of a NASA-funded effort to develop the foundation for future operationalization of air quality forecasting for world-wide end-users and integration into their air quality management decision processes, which will be achieved in future phases of this multi-year project. We will summarize our progress in developing a data fusion system using the Google Earth Engine platform which can integrate model, satellite, and surface-level monitoring datasets to enhance estimation and forecasting of air-quality-relevant pollutants at sub-daily and sub-city scales. The tool is being developed in close cooperation with several city- and regional-level air quality managers in the USA and around the world. Our end-goal is to provide these air quality managers with the information they need to assess and anticipate the impacts of poor air quality, track changes in air quality due to ongoing mitigation efforts and land use changes, and identify ways to improve their air quality monitoring strategies. This presentation will focus on recent advances achieved through the project, including integration of multiple air quality datasets in a prototype data fusion system in Google Earth Engine, the quantification of uncertainties associated with our data fusion approach, and the development of user interfaces and visualization tools to convey air quality information in a way which best meets end-user needs.

Carl Malings↗

Health and air pollutant emission impacts of net zero CO2 by 2050 scenarios from the energy modeling forum 37 study

Carbon dioxide and non-greenhouse gas air pollutants are emitted from many of the same sources. Decarbonization actions thus typically yield air pollutant emission reductions, resulting in significant air quality benefits. Although several studies have highlighted this connection, including in the context of net zero carbon emission targets, substantial uncertainty remains regarding how alternative technological pathways to this goal will affect the spatial distribution and magnitude of air pollutants. Comprehensive multi-model and multi-scenario analyzes are needed to explore the relative impacts of alternative pathways. Here, our study begins to address this gap by leveraging the results from the recent Energy Modeling Forum 37 inter-model comparison exercise on U.S. decarbonization pathways. Comparing the results of the six teams who submitted air pollutant emissions suggests that strategies that target net zero U.S. carbon emissions would yield significant reductions in many air pollutants, and that this finding is generally robust across pathways. However, some energy sources, such as biomass and fossil fuels with carbon capture, will emit air pollutants and can potentially influence the magnitude, spatial distribution, and even sign of localized air pollutant emission changes. In the second part of this analysis, a simplified air quality and health impacts screening model is used to evaluate the air quality impacts in 2035 of sectoral emission changes from the three models that provided sectoral detail. Relative to a reference scenario, a net zero pathway is estimated to reduce fine particulate matter concentrations across the contiguous U.S., with health benefits from reduced mortality ranging from $\$$65 billion to $\$$250 billion in 2035 alone (2023$\$$s). These benefits would be expected to grow over time as the net zero trajectory becomes more stringent. Both the magnitude of potential benefits and the substantial variation of the projections across models underscore the need for an EMF-like inter-model comparison exercise focused on air quality.

Air pollutants↗

Effect of Intake Air Filter Condition on Vehicle Fuel Economy

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy and the U.S. Environmental Protection Agency (EPA) jointly maintain a fuel economy website (www.fueleconomy.gov), which helps fulfill their responsibility under the Energy Policy Act of 1992 to provide accurate fuel economy information [in miles per gallon (mpg)] to consumers. The site provides information on EPA fuel economy ratings for passenger cars and light trucks from 1985 to the present and other relevant information related to energy use such as alternative fuels and driving and vehicle maintenance tips. In recent years, fluctuations in the price of crude oil and corresponding fluctuations in the price of gasoline and diesel fuels have renewed interest in vehicle fuel economy in the United States. (User sessions on the fuel economy website exceeded 20 million in 2008 compared to less than 5 million in 2004 and less than 1 million in 2001.) As a result of this renewed interest and the age of some of the references cited in the tips section of the website, DOE authorized the Oak Ridge National Laboratory (ORNL) Fuels, Engines, and Emissions Research Center (FEERC) to initiate studies to validate and improve these tips. This report documents a study aimed specifically at the effect of engine air filter condition on fuel economy. The goal of this study was to explore the effects of a clogged air filter on the fuel economy of vehicles operating over prescribed test cycles. Three newer vehicles (a 2007 Buick Lucerne, a 2006 Dodge Charger, and a 2003 Toyota Camry) and an older carbureted vehicle were tested. Results show that clogging the air filter has no significant effect on the fuel economy of the newer vehicles (all fuel injected with closed-loop control and one equipped with MDS). The engine control systems were able to maintain the desired AFR regardless of intake restrictions, and therefore fuel consumption was not increased. The carbureted engine did show a decrease in fuel economy with increasing restriction. However, the level of restriction required to cause a substantial (10-15%) decrease in fuel economy (such as that cited in the literature) was so severe that the vehicle was almost undrivable. Acceleration performance on all vehicles was improved with a clean air filter. Once it was determined how severe the restriction had to be to affect the carbureted vehicle fuel economy, the 2007 Buick Lucerne was retested in a similar manner. We were not able to achieve the level of restriction that was achieved with the 1972 Pontiac with the Lucerne. The Lucerne's air filter box would not hold the filter in place under such severe conditions. (It is believed that this testing exceeded the design limits of the air box.) Tests were conducted at a lower restriction level (although still considerably more severe than the initial clogged filter testing), allowing the air filter to stay seated in the air box, and no significant change was observed in the Lucerne's fuel economy or the AFR over the HFET cycle. Closed-loop control in modern fuel injected vehicle applications is sophisticated enough to keep a clogged air filter from affecting the vehicle fuel economy. However for older, open-loop, carbureted vehicles, a clogged air filter can affect the fuel economy. For the vehicle tested, the fuel economy with a new air filter improved as much as 14% over that with a severely clogged filter (in which the filter was so clogged that drivability was impacted). Under a more typical state of clog, the improvement with a new filter ranged from 2 to 6%.

02 PETROLEUM↗

The role of Health Impact Assessment in the setting of air quality standards: An Australian perspective

The approaches used for setting or reviewing air quality standards vary from country to country. The purpose of this research was to consider the potential to improve decision-making through integration of HIA into the processes to review and set air quality standards used in Australia. To assess the value of HIA in this policy process, its strengths and weaknesses were evaluated aligned with review of international processes for setting air quality standards. Air quality standard setting programmes elsewhere have either used HIA or have amalgamated and incorporated factors normally found within HIA frameworks. They clearly demonstrate the value of a formalised HIA process for setting air quality standards in Australia. The following elements should be taken into consideration when using HIA in standard setting. (a) The adequacy of a mainly technical approach in current standard setting procedures to consider social determinants of health. (b) The importance of risk assessment criteria and information within the HIA process. The assessment of risk should consider equity, the distribution of variations in air quality in different locations and the potential impacts on health. (c) The uncertainties in extrapolating evidence from one population to another or to subpopulations, especially the more vulnerable, due to differing environmental factors and population variables. (d) The significance of communication with all potential stakeholders on issues associated with the management of air quality. In Australia there is also an opportunity for HIA to be used in conjunction with the NEPM to develop local air quality standard measures. The outcomes of this research indicated that the use of HIA for air quality standard setting at the national and local levels would prove advantageous. -- Highlights: • Health Impact Assessment framework has been applied to a policy development process. • HIA process was evaluated for application in air quality standard setting. • Advantages of HIA in the air quality standard setting process are demonstrated.

54 ENVIRONMENTAL SCIENCES↗

A practical method to obtain kinetic data from $\mathrm{TGA}$ (thermogravimetric analysis) experiments to build an air injection model for enhanced oil recovery

To build an air injection model for enhanced oil recovery, it is necessary to obtain the kinetic data from thermal experiments. For TGA (thermogravimetry analysis) experiments, fitting the weight loss data using different forms of the Arrhenius Equation is practiced to obtain a single set of kinetic data which are used for the whole temperature range. The problem is that the kinetic data changes with the test temperature, oil composition, etc. Therefore, the obtained kinetic data do not represent the actual physics. Here this paper presents a detailed practical method to obtain kinetic data from TGA experiments to build an air injection model. The air injection model contains two parts. One part is to define fluid pseudo-components and their physical properties. The other part is to define oxidation reaction and the corresponding kinetic data. In order to validate the air injection model, both air purging TGA experiments and nitrogen purging TGA experiments are conducted. The fluid model (pseudo-components and their properties) is validated by matching model results with the nitrogen purging TGA experiments. Then, the kinetic data are obtained by matching the model results with the air purging TGA experiments. To verify the above approach to build an air injection model, TGA experiments using a pure hydrocarbon C20 and a Wolfcamp crude oil were conducted. The pure hydrocarbon C20 is used to verify the approach. Then seven oxidation reactions of seven pseudo components are utilized to define the air injection model for the Wolfcamp crude oil. The selection of the pseudo components was validated with the nitrogen purging TGA experiments and the oxidation reactions were validated with the air purging TGA experiments. The result shows that the combination of isomerization reactions and oxygen addition reactions can perfectly simulate a light oil air injection process in the low temperature region. This paper shows that an air injection model can be built using the kinetic data by analyzing TGA experiments.

42 ENGINEERING↗

Dosimetry of a Small Air Cavity for Clinical Electron Beams: A Monte Carlo Study

This study investigated dosimetric changes in a water phantom when a small air cavity was presented at the central axis of a clinical electron beam. We used 6-, 9-, and 16-MeV electron beams with a 10 x 10 cm{sup 2} applicator and cutout produced by a Varian 21 EX linear accelerator. Percentage depth doses (PDDs) for different depths (0.5-7 cm), thicknesses (2-10 mm), and widths (1-5 cm) of air cavities were calculated using Monte Carlo simulations (EGSnrc code) validated by film measurements. By comparing PDDs of phantoms with and without the air cavity, it was found that when the depth or thickness of cavity was changed, the PDD curve below the cavity was shifted with a distance equal to the thickness of the cavity. However, when the width of the air cavity was changed, both the PDD curve and its slope within and below the cavity were changed. A larger width of the air cavity resulted in a shallower PDD curve within the cavity. The slope of the PDD curve below the cavity tended towards a value as the width of the air cavity was increased to 3-5 cm for the 6-, 9-, and 16-MeV electron beams. The dependence of the depth dose on the width of the air cavity is a result of the contribution of the electron side scattering in the water surrounding the cavity. The change in depth dose resulting from the presence of an air cavity can cause discrepancies between the calculated and actual dose during radiotherapy, unless the effects of the air cavity are properly characterized during treatment planning. From the dosimetry data in this study, neglecting an air cavity of 1-cm thickness in the build-up region of a 6-MeV electron beam resulted in a delivered dose 10-12% larger than the original prescription. Delivered doses 3% and 6% higher than the prescribed dose were observed when doses were prescribed at R{sub 80} for a 16-MeV electron beam. These results were obtained by neglecting air cavities with thicknesses equal to 2 and 4 mm, respectively, at a depth of 5 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗