Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage regulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Implementing CubeSat Avionics Components to Full-Scale Capsule Return Missions

Returning samples from Low Earth Orbit (LEO) is no simple task. Whether the samples are scientific experiments or surveillance footage, engineers must overcome many challenges to achieve mission success. In August of 1960 the first payload recovered from LEO, the Corona capsule, carried “more photographic coverage of the Soviet Union than all previous U-2 missions”. The Corona program proved that re-turning surveillance footage from LEO is possible, the program is still referenced today when designing new sample return missions. Although there are many crucial subsystems that make up a sample return capsule, the avionics subsystem demands the most attention. This paper will discuss how current CubeSat avionics components can be applied to large sample return missions. One advantage of using CubeSat avionics components is that they can fit into a 1.5 U (10x10x15 cm) compartment, leaving more room for the payload. This paper is broken down as follows. First, the reader is introduced to the history of sample return projects. The major design strengths of previous projects are analyzed and applied to the current capsule design. Next, the typical trajectory of a capsule is presented along with mission requirements and operations. During the re-entry phase, the avionics subsystem is responsible for commanding the deployment of the parachute, back shell, and the heat shield. Next, the power subsystem is discussed in detail including a trade study on batteries and voltage regulators. Next, the interface between the Ground Support Equipment (GSE) and the avionics components is discussed. It is important that the capsule is able to provide avionics system state of health to ensure proper functionality before the capsule is launched. Next, an in-depth analysis of current TechEdSat avionics components, with proven flight history, are presented. The various avionics components including the radios, GPS, IMU, temperature sensors, altitude sensors, and ejectors are discussed. The application of cur-rent avionics components to a sample return projects are analyzed. After, the wiring diagram is presented along with a discussion of the design. Next, a summary of how the avionics components are tested and validated is pro-vided. Finally, this article will present current sample return missions TechEdSat avionics components are being applied to. CubeSat Avionics can be applied to almost all sample return missions due to their compact configuration and proven space flight heritage. The TechEdSat team is currently making great progress in returning samples from the International Space Station (ISS) and is excited to present how their avionics components can be applied to a full-scale sample return mission.

Hughes, Z. M.↗

Single-Event Latchup Measurements on COTS Electronic Devices for Use in ISS Payloads

This paper reports recent single-event latchup results for a variety of microelectronic devices that include an ADC, OpAmp, EEPROM, CPLD, PWM, transceiver, voltage regulator, digital signal processor, step-down converter, buck controller and supervisory circuits. The data were collected to evaluate these devices for possible use in NASA ISS payloads.

Irom, Farokh↗

Vorago RH-OBC-1 Single Event Effect Characterization Test Report

The Vorago Technologies RH-OBC-1 is a CubeSat Kit Bus compatible single board computer with a Vorago VA10820 ARM Cortex-M0 microcontroller at its core. The board also includes a set of common peripheral integrated circuits, like voltage regulators, non-volatile memories (NVM), an analog-to-digital converter (ADC), a watchdog/supervisor, and a Controller Area Network (CAN) bus transceiver. High-energy proton (200 MeV) testing was conducted at both board and component levels to investigate single-event effects.

CubeSat compatible board↗

Signal and Power Integrity Design Methodology for High-Performance Flight Computing Systems

Computing capabilities of space systems have in-creased onboard performance by orders of magnitude with the use of radiation-tolerant field-programmable gate arrays (FPGA)and processors. The incorporation of signal and power integrity analysis with printed circuit board (PCB) design in reliable computing architectures for space systems has become critical to enable future mission capabilities. Developers launch high-performance processors into a breadth of orbits and missions, running varying applications that create challenges for designing reliable computing hardware. Specifically, for these designs, academic and industry research has focused on component radiation performance, fault mitigation, and reliable architectures. How-ever, other design parameters including electromagnetic interference (EMI), PCB stackup, signal integrity (SI), voltage regulator module (VRM) design, and power distribution network (PDN)are often deprioritized or disregarded as the design matures. Since these characteristics are becoming more significant in high-performance processor designs, this research presents a hardware design and analysis methodology for high-performance, space-computing systems that focuses on a holistic design approach and PDN reliability. While these challenges exist across all space hardware, the reduced PCB dimensions imposed by SmallSats and CubeSats introduce additional hurdles, specifically to VRM and decoupling design. By examining the relationship between the PDN and radiation performance, an analytical relationship is developed that incorporates Total Ionizing Dose and Single-Event Transients to ensure reliability throughout the mission duration. The presented design methodology is applied to the SpaceCube v3.0 Mini, an FPGA-based on-board science data processing system developed at NASA Goddard Space Flight Center.

Advanced avionics↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Upgrade of the Klystron Modulator at SLAC

The SLAC National Accelerator Laboratory employs 244 klystron modulators on its two-mile-long linear accelerator that has been operational since the early days of the SLAC establishment in the sixties. Each of these original modulators was designed to provide 250 kV, 262 A and 3.5 {mu}S at up to 360 pps using an inductance-capacitance resonant charging system, a modified type-E pulse-forming network (PFN), and a pulse transformer. The modulator internal control comprised of large step-start resistor-contactors, vacuum-tube amplifiers, and 120 Vac relays for logical signals. A major, power-component-only upgrade, which began in 1983 to accommodate the required beam energy of the SLAC Linear Collider (SLC) project, raised the modulator peak output capacity to 360 kV, 420 A and 5.0 {mu}S at a reduced pulse repetition rate of 120 pps. In an effort to improve safety, performance, reliability and maintainability of the modulator, this recent upgrade focuses on the remaining three-phase AC power input and modulator controls. The upgrade includes the utilization of primary SCR phase control rectifiers, integrated fault protection and voltage regulation circuitries, and programmable logic controllers (PLC) -- with an emphasis on component physical layouts for safety and maintainability concerns. In this paper, we will describe the design and implementation of each upgraded component in the modulator control system. We will also report the testing and present status of the modified modulators.

43 PARTICLE ACCELERATORS↗

Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control

GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

ARPA-E↗

Studying the Impact of Distributed Solar PV on Power Systems using Integrated Transmission and Distribution Models: Preprint

This paper presents the results of a distributed solar PV impact assessment study that was performed using a synthetic integrated transmission (T) and distribution (D) model. The primary objective of the study was to present a new approach for distributed solar PV impact assessment, where along with detailed models of transmission and distribution networks, consumer loads were modeled using the physics of end-use equipment, and distributed solar PV was geographically dispersed and connected to the secondary distribution networks. The highlights of the study results were (i) increase in the Area Control Error (ACE) at high penetration levels of distributed solar PV; and (ii) differences in distribution voltages profiles and voltage regulator operations between integrated T&D and distribution only simulations.

14 SOLAR ENERGY↗

Predictive Analytics for Coordinated Optimization in Distribution Systems

This talk will present NREL's work on developing predictive analytics that enables the optimal coordination of all the available resources in distribution systems to achieve the control objectives of system operators. Two projects will be presented. One focuses on developing short-term state forecasting-based optimal voltage regulation in distribution systems; and the other one focuses on actively engaging electricity consumers to benefit distribution system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quasi-Static Times Series PV Hosting Capacity Methodology and Metrics: Preprint

Distributed photovoltaic systems (DPV) can cause adverse grid impacts, including voltage or thermal violations. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current methods for determining hosting capacity tend to be conservative by either only considering infrequent worst-case snapshots in time and/or only capturing coarse time and spatial resolution. Additionally, current hosting capacity methods do not accurately capture the time-dependence making them unable to capture the behavior of voltage regulating equipment and of some advanced controls mitigations. This can trigger delays from unnecessary engineering analysis or deter solar installations in areas that are actually suitable. We propose a quasi-static-timeseries (QSTS) based PV hosting capacity methodology to address these issues. With this approach, we conduct power flow analysis over the course of a full year, to capture time-varying parameters and control device actions explicitly. We show that this approach can more fully capture grid impacts of DPV than traditional methods.

14 SOLAR ENERGY↗

Distributed Cooperative Control of Hybrid AC/DC Microgrid: Preprint

This paper presents a distributed cooperative control-based power management algorithm for a hybrid AC/DC microgrid. The proposed algorithm for a hybrid microgrid system controls the power flow through the interface converter between the AC and DC microgrids. This algorithm allows power sharing between the distributed generators in the microgrid according to their power ratings. Moreover, it enables the fixed scheduled power delivery through the interface converters in both directions at different operating conditions while maintaining voltage regulation and improving the frequency profile. The effectiveness of the controller is confirmed by simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protective Relaying for Distribution and Microgrids Evolving from Radial to Bi-Directional Power Flow

As distributed energy resources (DER) achieve higher penetration levels in distribution systems, the normal flow of power (and fault current) is no longer unidirectional, from substation source to load (or fault). The increased importance of DER has also led to pending revisions in the DER interconnection standards, particularly voltage regulation and ride-through, with publication of a new IEEE Standard 1547 expected in early 2018. These changes have complicated normal distribution system operation, and they will also complicate distribution system protection. The U. S. Department of Energy undertook a review of protection state-of-the-art for this new environment in order to identify gaps and propose near-term solutions.

McDermott, Tom↗

Distributed Cooperative Control of Hybrid AC/DC Microgrid

This paper presents a distributed cooperative control-based (DCC) power management algorithm for a hybrid AC/DC microgrid. The proposed algorithm for a hybrid microgrid system controls the power flow through the interface converter between the AC and DC microgrids. This algorithm allows power sharing between the distributed generators in the microgrid according to their power ratings. Moreover, it enables the fixed scheduled power delivery through the interface converters in both directions at different operating conditions while maintaining voltage regulation and improving the frequency profile.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow: Preprint

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Grid Code Essentials and Streamlining Process for Interconnections

This presentation was part of a webinar entitled "A Practitioner's Guide to Implementing Solar Rooftop Programs and Navigating Net-Metering Policies," hosted by USAID Clean Power Asia and included speakers the Hawaii Natural Energy Institute as well as NREL. This presentation outlines grid codes in general, and IEEE Std 1547-2018 specifically, and discusses their adoption into interconnection requirements. Key capabilities, now enabled by IEEE Std 1547-2018, such as voltage regulation and frequency ride-through are described.

DER↗

VOLTTRON™ Agent Development for Enabling Reactive Power Support of Non-Utility DERs by Integrating Transactive Energy Approach

To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.

Kritprajun, Paychuda↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗