Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Thermal elastohydrodynamic lubrication of spur gears

An analysis and computer program called TELSGE were developed to predict the variations of dynamic load, surface temperature, and lubricant film thickness along the contacting path during the engagement of a pair of involute spur gears. The analysis of dynamic load includes the effect of gear inertia, the effect of load sharing of adjacent teeth, and the effect of variable tooth stiffness which are obtained by a finite-element method. Results obtained from TELSGE for the dynamic load distributions along the contacting path for various speeds of a pair of test gears show patterns similar to that observed experimentally. Effects of damping ratio, contact ratio, tip relief, and tooth error on the dynamic load were examined. In addition, two dimensionless charts are included for predicting the maximum equilibrium surface temperature, which can be used to estimate directly the lubricant film thickness based on well established EHD analysis.

Wang, K. L.↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Industrial Load Flexibility, the U.S. Power Grid and Ammonia

A variable renewable power grid is a new technological regime that involves real time harvesting and low-cost availability of energy resources coupled with storage to meet additional needs. Decarbonization through electrification of end uses formerly met by combustion processes will be a concurrent trend. Taken together, these two changes may make flexibility on the demand side more valuable to the grid and to industrial users. Industry accounted for 26% of US power demand in 2021. Traditionally, industrial processes for producing ammonia and other basic materials have been optimized for a system based on fossil resources, where energy can be called upon according to needs. Large capital expenditures as well as safety considerations have favored plants running at steady state at close to their maximum capacity. It is possible, however, that the renewable energy transition will offer opportunities to sectors that can operate in a more flexible manner. Innovations that make use of flexibility to enhance their business model to move forward, individuals and groups active in their development, use and regulation, together with institutions and infrastructures, can be considered as a technological innovation system (TIS). Beyond economic and technical factors on their own, the TIS is an important analysis framework for studying the development and diffusion of technologies. This work attempts to map the TIS of flexible industrial loads and their interaction with electric power in the US, with a particular focus on ammonia as a case study. We have conducted interviews with stakeholders involved in ammonia projects, working in system operators, trade groups, regulators and utilities. We assess to what extent a technological innovation system is functioning and document characteristics that allow industries to operate flexibly.

ammonia↗

Development of a Non-Iterative Balance Load Prediction Algorithm for the NASA Ames Unitary Plan Wind Tunnel

A non-iterative load prediction algorithm for strain-gage balances was developed for the NASA Ames Unitary Plan Wind Tunnels that computes balance loads from the electrical outputs of the balance bridges and a set of state variables. A state variable could be, for example, a balance temperature difference or the bellows pressure of a flow-through balance. The algorithm directly uses regression models of the balance loads for the load prediction that were obtained by applying global regression analysis to balance calibration data. This choice greatly simplifies both implementation and use of the load prediction process for complex balance configurations as no load iteration needs to be performed. The regression model of a balance load is constructed by using terms from a total of nine term groups. Four term groups are derived from a Taylor Series expansion of the relationship between the load, gage outputs, and state variables. The remaining five term groups are defined by using absolute values of the gage outputs and state variables. Terms from these groups should only be included in the regression model if calibration data from a balance with known bi-directional outputs is analyzed. It is illustrated in detail how global regression analysis may be applied to obtain the coefficients of the chosen regression model of a load component assuming that no linear or massive near-linear dependencies between the regression model terms exist. Data from the machine calibration of a six-component force balance is used to illustrate both application and accuracy of the non-iterative load prediction process.

Ulbrich, Norbert M.↗

Forte: An Interactive Visual Analytic Tool for Trust-Augmented Net-Load Forecasting

Accurate net-load forecasting is vital for energy planning, aiding decisions on trade and load distribution. However, assessing the performance of forecasting models across diverse input variables, like temperature and humidity, remains challenging, particularly for eliciting a high degree of trust in the model outcomes. In this context, there is a growing need for data-driven technological interventions to aid scientists in comprehending how models react to both noisy and clean input variables, thus shedding light on complex behaviors and fostering confidence in the outcomes. In this paper, we present Forte, a visual analytics-based application to explore deep probabilistic net-load forecasting models across various input variables and understand the error rates for different scenarios. With carefully designed visual interventions, this web-based interface empowers scientists to derive insights about model performance by simulating diverse scenarios, facilitating an informed decision-making process. We discuss observations made using Forte and demonstrate the effectiveness of visualization techniques to provide valuable insights into the correlation between weather inputs and net-load forecasts, ultimately advancing grid capabilities by improving trust in forecasting models.

Bhattacharjee, Kaustav↗

Probabilistic Assessment of Adaptive Space Truss Configurations for Thermal Buckling Resistance

A three-bay, cantilever truss of a type typically used in space structures, is probabilistically evaluated to configure adaptive/smart/intelligent behavior for resisting thermal buckling. This buckling is due to nonuniform thermal loads and a combination of these loads with applied loads and moments (mechanical loads). For each behavior the scatter (ranges) in buckling loads and member axial forces are probabilistically determined. Sensitivities associated with uncertainties in the structural and material variables that describe the truss, as well as scatter in mechanical and thermal loads, are determined for different probabilities. The relative magnitude of these sensitivities are used to identify significant truss variables that control/classify the truss behavior and cause it to respond as an adaptive/smart/ intelligent structure. Results show that the probabilistic buckling loads increase for adaptive and intelligent truss classifications, with a substantial increase for intelligent trusses. Similarly, the probabilistic member axial forces decrease for each truss classification.

Pai, Shantaram S.↗

An Atmospheric Variability Model for Venus Aerobraking Missions

Aerobraking has proven to be an enabling technology for planetary missions to Mars and has been proposed to enable low cost missions to Venus. Aerobraking saves a significant amount of propulsion fuel mass by exploiting atmospheric drag to reduce the eccentricity of the initial orbit. The solar arrays have been used as the primary drag surface and only minor modifications have been made in the vehicle design to accommodate the relatively modest aerothermal loads. However, if atmospheric density is highly variable from orbit to orbit, the mission must either accept higher aerothermal risk, a slower pace for aerobraking, or a tighter corridor likely with increased propulsive cost. Hence, knowledge of atmospheric variability is of great interest for the design of aerobraking missions. The first planetary aerobraking was at Venus during the Magellan mission. After the primary Magellan science mission was completed, aerobraking was used to provide a more circular orbit to enhance gravity field recovery. Magellan aerobraking took place between local solar times of 1100 and 1800 hrs, and it was found that the Venusian atmospheric density during the aerobraking phase had less than 10% 1 sigma orbit to orbit variability. On the other hand, at some latitudes and seasons, Martian variability can be as high as 40% 1 sigmaFrom both the MGN and PVO mission it was known that the atmosphere, above aerobraking altitudes, showed greater variability at night, but this variability was never quantified in a systematic manner. This paper proposes a model for atmospheric variability that can be used for aerobraking mission design until more complete data sets become available.

Tolson, Robert T.↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗

The effect of initial imperfections on shell stability: An updated review

The development of the Delft Interactive Shell Design Code (DISDECO) is described. The purpose is to make the accumulated theoretical, numerical, and practical knowledge of the last years readily accessible to users interested in the analysis of buckling sensitive structures. With this open ended, hierarchical, interactive computer code, the user can access workstation programs of increasing complexity. As a first update of DISDECO, the computational modules of the initial level were modified so as to handle combined loads consisting of axial compression, internal and external pressure, and clockwise or counter clockwise torque. The applied load is assumed to have a uniform spatial distribution and is divided into a fixed and a variable part. The magnitude of the variable part is allowed to vary in proportion to a load parameter Lambda. This leads to an eigenvalue problem for the critical lambda sub C.

Arbocz, J.↗

A synthetic building operation dataset

Abstract This paper presents a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years’ historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants’ diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

An extended model for determining dynamic loads in spur gearing

In this study a large scale digitized approach is used for an uninterrupted static and dynamic analysis of spur gearing. An interactive method was developed to calculate directly the variable gear mesh stiffness as a function of transmitted load, gear profile errors, gear tooth deflections and gear hub torsional deformation, and position of contacting profile points. The developed methods are applicable to both the normal and high contact ratio gearing. Certain types of simulated sinusoidal profile errors and pitting can cause interruptions of the normal gear mesh stiffness function and, thus, increase the dynamic loads in gearing.

Kasuba, R.↗

Life Predicted in a Probabilistic Design Space for Brittle Materials With Transient Loads

Analytical techniques have progressively become more sophisticated, and now we can consider the probabilistic nature of the entire space of random input variables on the lifetime reliability of brittle structures. This was demonstrated with NASA s CARES/Life (Ceramic Analysis and Reliability Evaluation of Structures/Life) code combined with the commercially available ANSYS/Probabilistic Design System (ANSYS/PDS), a probabilistic analysis tool that is an integral part of the ANSYS finite-element analysis program. ANSYS/PDS allows probabilistic loads, component geometry, and material properties to be considered in the finite-element analysis. CARES/Life predicts the time dependent probability of failure of brittle material structures under generalized thermomechanical loading--such as that found in a turbine engine hot-section. Glenn researchers coupled ANSYS/PDS with CARES/Life to assess the effects of the stochastic variables of component geometry, loading, and material properties on the predicted life of the component for fully transient thermomechanical loading and cyclic loading.

Nemeth, Noel N.↗

Crustal Displacements Due to Continental Water Loading

The effects of long-wavelength (> 100 km), seasonal variability in continental water storage on vertical crustal motions are assessed. The modeled vertical displacements (delta-r(sub M)) have root-mean-square (RMS) values for 1994-1998 as large as 8 mm with ranges up to 30 mm, and are predominantly annual in character. Regional strains are on the order of 20 nanostrain for tilt and 5 nanostrain for horizontal deformation. We compare delta-r(sub M) with observed Global Positioning System (GPS) heights (delta-r(sub O)) (which include adjustments to remove estimated effects of atmospheric pressure and annual tidal and non-tidal ocean loading) for 147 globally distributed sites. When the delta-r(sub O) time series are adjusted by delta-r(sub M), their variances are reduced, on average, by an amount equal to the variance of the delta-r(sub M). Of the delta-r(sub O) time series exhibiting a strong annual signal, more than half are found to have an annual harmonic that is in phase and of comparable amplitude with the annual harmonic in the delta-r(sub M). The delta-r(sub M) time series exhibit long-period variations that could be mistaken for secular tectonic trends or post-glacial rebound when observed over a time span of a few years.

vanDam, T.↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗