Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This presentation describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

electrified aircraft propulsion↗

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This paper describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

Electrified powertrain↗

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Evaluation of Centralized Model-Based FLISR in a Lab Setup: Preprint

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

OT Operational Anomaly Detection (OAD) T&D + DER

The growth of utility-scale renewable energy resources, distributed energy resources (DER), and transportation electrification has increased uncertainty and cybersecurity risks in power grids. The Purdue Enterprise Reference Architecture model which is widely adopted by the utility industry is now insufficient to protect the power grid against cyber-attacks. There is a need to identify what cybersecurity model is effective on Energy Management System (EMS), Advanced Distribution Management System (ADMS), and DER Management System (DERMS) to address the fundamental cybersecurity challenges in the age of increasing renewable energy and DER share as well as consumer participation in the electric energy industry. The next generation of cybersecurity model for OT network should be able to detect inside attackers, mitigate the cybersecurity risks arising from the new grid participants including DER aggregators, electric vehicle owners, and behind-the-meter consumers outside the utility company, and develop the strategy to trust consumer measurement data. This panel will discuss the challenges and pathways for the development of an ensemble cybersecurity model based on predictive state estimation to detect cybersecurity anomalies in OT network including EMS, ADMS, and DERMS.

cybersecurity↗

Local and utility-wide cost allocations for a more equitable wildfire-resilient distribution grid

Climate-induced extreme weather conditions make electricity infrastructure more vulnerable. They increase the risk of power-line-ignited wildfires which can, in turn, jeopardize electric power delivery. Here, leveraging machine learning, we show that lower-income communities in California not only have lower fractions of power distribution lines undergrounded, but overhead lines and poles in their neighbourhoods are also more vulnerable to wildfires. Should they bear the cost of undergrounding fire-prone lines themselves, they would have to pay a disproportionately higher cost per household. We propose a cost allocation scheme with an income threshold below which the cost is borne by utility-wide ratepayers and above which the cost is borne locally. This scheme can not only minimize the average of undergrounding costs per household as a share of income, but also homogenize such cost–income ratios across communities. Furthermore, our research demonstrates the opportunity to appropriately integrate existing policies to make electricity infrastructure affordable, equitable and reliable amidst climate change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The use of price-based demand response as a resource in electricity system planning

Utilities have conducted IRP for decades to consider both supply- and demand-side resources to meet bulk power system needs. More recently, an increasing number of states are requiring regulated utilities to file plans that identify distribution system needs, including DERs that can avoid or defer certain types of traditional utility investments cost-effectively. Price-based demand response (DR) is an underutilized resource that could substantially contribute to load flexibility. We find that evaluation of price-based DR as a solution to meet identified electricity system needs is uncommon at both planning processes. Where price-based DR is considered as a solution, methodologies are often deficient in the characterization and treatment of this resource. Based on our analysis of utility filings and state requirements, this brief provides recommendations for improving consideration of price-based DR in the context of long-term planning for bulk power and distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

DGaaS: GPU as a Service on Distributed Computing System

In the rapidly evolving landscape of scientific computing, Graphics Processing Units (GPUs) have become indispensable for their unparalleled ability to handle parallel tasks in complex calculations, simulations, and data analysis. Their utility is further magnified in machine learning and AI applications, where they significantly accelerate model training and predictive analytics. Within this context, the Triton Inference Server emerges as a pivotal open-source tool, specializing in AI inferencing and optimizing GPU utilization across various platforms and frameworks. This paper presents an in-depth study on distributed High Throughput Computing (HTC), specifically focusing on the HTCondor framework and its resource provisioning tools, GlideinWMS and HEPCloud. These systems enable large-scale scientific experiments like CMS and DUNE to efficiently access and utilize vast computational resources. The paper explores the core architectural components of GlideinWMS, including jobs, user pools, and worker nodes, and discusses their integration with GPUs and the Triton server. The primary aim of this research is to develop a solution that optimizes GPU utilization by leveraging Glideins and containers. This approach allows computational jobs, particularly those involving AI models, to use GPUs only when essential, thereby facilitating efficient sharing of limited GPU resources. To validate this architecture, the study conducted three key tests involving custom scripts, container-based servers, and Triton server deployments. However, the study faces challenges, notably in locating the Triton server and ensuring secure remote access. To address these issues, future work will focus on developing a proxy mechanism and enhancing security protocols. In conclusion, this study offers a comprehensive roadmap for effective and efficient GPU utilization in distributed High Throughput Computing. It aims to contribute significantly to the scientific community by solving pressing problems and implementing robust solutions in collaboration with the GlideinWMS and HEPCloud teams. The research sets the stage for a more efficient, scalable, and cost-effective paradigm in scientific computing.

97 MATHEMATICS AND COMPUTING↗

A Decision Support Tool for Distributed Solar and Storage Investments: A Case Study in Austin, TX

This study builds a decision support tool to evaluate when it is a good economic decision (least cost with minimum discomfort) for the residential customer to invest in distributed energy resources (DERs) based on different electricity rate structures, DER ownership frameworks, and DER rebates offered by electric utilities. Here, the tool is demonstrated using empirical electricity consumption data from Pecan Street Inc. (a non-profit entity based on Austin, Texas), residential rates from Austin Energy (the municipal electric utility in Austin, Texas), DER ownership costs from various nationwide pilot programs, and incentives offered by electric utilities in the United States. Results show that for constant electricity rates, the overall expenditure is least when the customer owns solar panels without storage, while for time-varying pricing structures, the least expensive scenario is one where the customer does not own any DERs. As the capital costs for DERs decline, utilities incentivize customer ownership of DERs, and more residential customers face the decision of whether to invest in DERs, this study aims to be a key tool in aiding that decision-making process.

14 SOLAR ENERGY↗

Estimated Probability of a Cervical Spine Injury During an ISS Mission

Introduction: The Integrated Medical Model (IMM) utilizes historical data, cohort data, and external simulations as input factors to provide estimates of crew health, resource utilization and mission outcomes. The Cervical Spine Injury Module (CSIM) is an external simulation designed to provide the IMM with parameter estimates for 1) a probability distribution function (PDF) of the incidence rate, 2) the mean incidence rate, and 3) the standard deviation associated with the mean resulting from injury/trauma of the neck. Methods: An injury mechanism based on an idealized low-velocity blunt impact to the superior posterior thorax of an ISS crewmember was used as the simulated mission environment. As a result of this impact, the cervical spine is inertially loaded from the mass of the head producing an extension-flexion motion deforming the soft tissues of the neck. A multibody biomechanical model was developed to estimate the kinematic and dynamic response of the head-neck system from a prescribed acceleration profile. Logistic regression was performed on a dataset containing AIS1 soft tissue neck injuries from rear-end automobile collisions with published Neck Injury Criterion values producing an injury transfer function (ITF). An injury event scenario (IES) was constructed such that crew 1 is moving through a primary or standard translation path transferring large volume equipment impacting stationary crew 2. The incidence rate for this IES was estimated from in-flight data and used to calculate the probability of occurrence. The uncertainty in the model input factors were estimated from representative datasets and expressed in terms of probability distributions. A Monte Carlo Method utilizing simple random sampling was employed to propagate both aleatory and epistemic uncertain factors. Scatterplots and partial correlation coefficients (PCC) were generated to determine input factor sensitivity. CSIM was developed in the SimMechanics/Simulink environment with a Monte Carlo wrapper (MATLAB) used to integrate the components of the module. Results: The probability of generating an AIS1 soft tissue neck injury from the extension/flexion motion induced by a low-velocity blunt impact to the superior posterior thorax was fitted with a lognormal PDF with mean 0.26409, standard deviation 0.11353, standard error of mean 0.00114, and 95% confidence interval [0.26186, 0.26631]. Combining the probability of an AIS1 injury with the probability of IES occurrence was fitted with a Johnson SI PDF with mean 0.02772, standard deviation 0.02012, standard error of mean 0.00020, and 95% confidence interval [0.02733, 0.02812]. The input factor sensitivity analysis in descending order was IES incidence rate, ITF regression coefficient 1, impactor initial velocity, ITF regression coefficient 2, and all others (equipment mass, crew 1 body mass, crew 2 body mass) insignificant. Verification and Validation (V&V): The IMM V&V, based upon NASA STD 7009, was implemented which included an assessment of the data sets used to build CSIM. The documentation maintained includes source code comments and a technical report. The software code and documentation is under Subversion configuration management. Kinematic validation was performed by comparing the biomechanical model output to established corridors.

Brooker, John E.↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DoCeph: DPU-Offloaded Messaging in Ceph for Reduced Host CPU Utilization

Ceph is a widely used distributed object store, but its messenger layer imposes substantial CPU overhead on the host. To address this limitation, we propose DoCeph, a DPU-offloaded storage architecture for Ceph that disaggregates the system by offloading the communication-intensive messaging component to the DPU while retaining the storage backend on the host. The DPU efficiently manages communication, using lightweight RPC for metadata operations and DMA for data transfer. Moreover, DoCeph introduces a pipelining technique that overlaps data transmission with buffer preparation, mitigating hardware-imposed transfer size limitations. We implemented DoCeph on a Ceph cluster with NVIDIA BlueField-3 DPUs. Evaluation results indicate that DoCeph cuts host CPU usage by up to 92% while sustaining stable throughput and providing larger performance benefits for object writes over 1 MB.

Park, Kuri [Sogang University]↗

Concept for a distributed processor computer

Future generation computer utilizes cell of single metal oxide semiconductor wafer containing general purpose processor section and small memory of approximately 512 words of 16 bits each. Cells are organized into groups and groups interconnected to form computer.

Bogue, P. N.↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of an approach and landing system model to the space shuttle orbiter vehicle

An analytic model and procedure are described which can be used to estimate probability distributions of touchdown conditions, without utilizing a Monte Carlo simulation. Example applications are presented, including one-step and two-step flare strategies for the space shuttle orbiter. The computed probability distributions for the two-step flare are compared with the corresponding histograms from an independent Monte Carlo simulation of the same situation. The computed distributions are very good fits to the Monte-Carlo-generated histograms for pertinent longitudinal and lateral variables at three points (including touchdown) along the vehicle's final approach trajectory. The model, thus verified, has more inherent power for assessing the effects of system element changes than conventional Monte Carlo techniques.

Johnson, W. A.↗

C Language Integrated Production System, Version 5.0

CLIPS 5.0 provides cohesive software tool for handling wide variety of knowledge with support for three different programming paradigms: rule-based, object-oriented, and procedural. CLIPS 5.0 available in version for IBM Personal Computer (MSC-21916), in one for Macintosh computer (MSC-21927), and in one for DEC VAX computer (MSC-21929). Computer Software Management and Information Center (COSMIC) offers five distribution versions of CLIPS 5.0. Executable files, source code, utilities, and examples included on program medium. All distribution versions include identical source code for command-line version of CLIPS 5.0. Source code compatible with ANSI C and compilable on any computer with ANSI C compiler. Only Macintosh version of CLIPS 5.0 includes window interface.

Riley, Gary↗