Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmissive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

High-Power and Flexible Low-Frequency AC Transmission for Renewable Integration

This project develops a steady-state, dynamic, and production cost models of a multi-terminal, high-power, flexible low-frequency ac (LF-HVac) transmission system with grid-forming converters. Through both numerical analysis and EMTP simulation, the project goal is to demonstrate the feasibility of such an innovative and transformative LF-HVac system to support bulk integration of large-scale, cheap, and steady renewable resources from remote locations such as offshore wind farms to meet recent clean energy goals from DOE. The proposed adoption of low-frequency ac transmission aims to improve power transfer capability for remote large-scale renewable integration. In addition, the control for power electronics converters provides grid-support functions to improve the flexibility and resilience the existing 60-Hz HVac system. Future projects on this topic can be supported by both Energy Efficiency and Renewable Energy (DOEEE) and Office of Electricity Delivery & Energy Reliability (DOEOE) offices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: 2024 Edition, Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2023 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require projects seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. The amount of new electric capacity in these queues is growing dramatically, with nearly 2,600 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). However, most projects that apply for interconnection are ultimately withdrawn, and those that are built are taking longer on average to complete the required studies and become operational. Data from these queues nonetheless provide a general indicator for mid-term trends in developer interest.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transforming Regional Transmission Planning: FERC Order 1920 Explained [Slides]

This presentation presents the key topics from FERC Order 1920: Building for the Future Through Electric Regional Transmission Planning and Cost Allocation. It breaks down and summarizes the main reforms from the regulation including comments from diverse perspectives on how the new rules may be implemented. This presentation can serve as a resource for diverse stakeholders including policymakers, utilities, industry, and researchers who seek to understand how the new ruling may impact regional transmission planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Transmission Planning Study - Chapter 5: Stress Analysis for 2035 Scenarios

The National Transmission Planning Study (NTP Study) is presented as a collection of six chapters, each of which is listed next. The NTP Study was led by the U.S. Department of Energy's Grid Deployment Office, in partnership with the National Renewable Energy Laboratory and Pacific Northwest National Laboratory. Chapter 5: Stress Analysis for 2035 Scenarios (this chapter) outlines how the future transmission expansions perform under stress tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Ready Flexible Transformers for Resilient Transmission Networks

Today’s transmission networks extend for hundreds of kilometers, transferring significant amounts of electrical energy. For every country, there are sort of “back- bone” lines, where a massive failure of transformers would create serious challenges to sustain a reliable energy supply. Natural phenomena and human driven actions could be triggers of such catastrophic events. For large utilities, or groups of utilities, it would be highly convenient to count with “flexible transformers”, which could be used as replacements for different voltage levels and with impedance adjustable to match optimum local requirements of impacted substations. Currently applied “emergency transformers” are fixed-impedance devices. In this contribution, a new concept of flexible, “future-grid ready” type of power transformers, specially devised for transmission networks is explained. This transformer has adjustable impedance features, which could be on-line operated. The concept has been proven to be functional and stable in the factory lab and in the field, by means of a prototype autotransformer of of 100 MVA, 165/69 Kv.

impedance of transformers↗

Solar PV Transmission Setbacks: Ordinances (2022) and Extrapolated Trends

This dataset represents solar energy setback requirements from transmission. A setback requirement is a minimum distance from transmission infrastructure that an energy project may be developed. As of April 2022, no ordinances were discovered for any counties. Such ordinances are likely to arise as regulations continue to expand. Therefore, this dataset applies a 30-meter setback, sourced from trends in other infrastructure. A TIF data file and a PNG map of the data are provided, showing areas where solar energy is prohibited or permitted across the contiguous United States. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Array↗

Predicting beam transmission using 2-dimensional phase space projections of hadron accelerators

We present a method to compress the 2D transverse phase space projections from a hadron accelerator and use that information to predict the beam transmission. This method assumes that obtaining at least three projections of the 4D transverse phase space is possible and that an accurate simulation model is available for the beamline. Using a simulated model, we show that—a computer can train a convolutional autoencoder to reduce phase-space information which can later be used to predict the beam transmission. Finally, we argue that although using projections from a realistic nonlinear distribution produces less accurate results, the method still generalizes well.

43 PARTICLE ACCELERATORS↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

The Hubble Space Telescope PanCET Program: An Optical to Infrared Transmission Spectrum of HAT-P-32Ab

We present a 0.3−5 μm transmission spectrum of the hot Jupiter HAT-P-32Ab observed with the Space Telescope Imaging Spectrograph and Wide Field Camera 3 instruments mounted on the Hubble Space Telescope, combined with Spitzer Infrared Array Camera photometry. The spectrum is composed of 51 spectrophotometric bins with widths ranging between 150 and 400 Å, measured to a median precision of 215 ppm. Comparisons of the observed transmission spectrum to a grid of 1D radiative-convective equilibrium models indicate the presence of clouds/hazes, consistent with previous transit observations and secondary eclipse measurements. To provide more robust constraints on the planet’s atmospheric properties, we perform the first full optical to infrared retrieval analysis for this planet. The retrieved spectrum is consistent with a limb temperature of 1248{sub −92}{sup +92} K, a thick cloud deck, enhanced Rayleigh scattering, and ∼10× solar H{sub 2}O abundance. We find log(Z/Z {sub ⊙}) = 2.41{sub −0.07}{sup +0.06}, and compare this measurement with the mass–metallicity relation derived for the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

An Unusual Transmission Spectrum for the Sub-Saturn KELT-11b Suggestive of a Subsolar Water Abundance

We present an optical-to-infrared transmission spectrum of the inflated sub-Saturn KELT-11b measured with the Transiting Exoplanet Survey Satellite (TESS), the Hubble Space Telescope (HST) Wide Field Camera 3 G141 spectroscopic grism, and the Spitzer Space Telescope (Spitzer) at 3.6 μm, in addition to a Spitzer 4.5 μm secondary eclipse. The precise HST transmission spectrum notably reveals a low-amplitude water feature with an unusual shape. Based on free-retrieval analyses with varying molecular abundances, we find strong evidence for water absorption. Depending on model assumptions, we also find tentative evidence for other absorbers (HCN, TiO, and AlO). The retrieved water abundance is generally ≲0.1× solar (0.001–0.7× solar over a range of model assumptions), several orders of magnitude lower than expected from planet formation models based on the solar system metallicity trend. We also consider chemical-equilibrium and self-consistent 1D radiative-convective equilibrium model fits and find that they, too, prefer low metallicities ([M/H] ≲ -2, consistent with the free-retrieval results). However, all of the retrievals should be interpreted with some caution because they either require additional absorbers that are far out of chemical equilibrium to explain the shape of the spectrum or are simply poor fits to the data. Finally, we find that the Spitzer secondary eclipse is indicative of full heat redistribution from KELT-11b’s dayside to nightside, assuming a clear dayside. These potentially unusual results for KELT-11b’s composition are suggestive of new challenges on the horizon for atmosphere and formation models in the face of increasingly precise measurements of exoplanet spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining Mornings and Evenings on Distant Worlds: A new Semianalytical Approach and Prospects with Transmission Spectroscopy

The technique of transmission spectroscopy—the variation of a planetary radius with wavelength due to opacity sources in the planet’s terminator region—has been one of the most successful in the characterization of exoplanet atmospheres to date, providing key insights into the composition and structure of these distant worlds. A common assumption made when using this technique, however, is that the variations are the same in the entire terminator region. In reality, the morning and evening terminators might have distinct temperature, pressure, and thus compositional profiles due to the inherent 3D nature of the planet, which would, in turn, give rise to different spectra on each side of it. Constraining those might be fundamental for our understanding of not only the weather patterns in these distant worlds but also the planetary formation signatures that might only be possible to extract once these features are well understood. Motivated by this physical picture, in this work, we perform a detailed study of the observational prospects of detecting this effect. We present an open-source semianalytical framework with which this information can be extracted directly from transit light curves and perform a detailed study of the prospects of detecting the effect with current missions, such as TESS, and upcoming ones, such as JWST. Our results show that these missions show great promise for the detection of this effect. Transmission spectroscopy studies with JWST, in particular, could provide spectra of each of the limbs, allowing us to convey 3D information previously accessible only via phase curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rethinking the Role of Financial Transmission Rights in Wind-Rich Electricity Markets in the Central U.S.

Transmission congestion can cause a divergence between wholesale power prices at the individual pricing nodes where power is generated and the more-liquid trading hubs where that power is often delivered and sold. This nodal price difference is commonly referred to as the “locational basis” (or just “basis”). Because the basis varies over time, it can—if not hedged—unpredictably affect a wind plant’s revenue and/or value, which increases investor risk and potentially slows deployment. We find wind plants typically face a larger and more-negative basis than do thermal generators, and hence are more-negatively impacted by congestion. Moreover, while most thermal generators can effectively hedge basis risk by purchasing conventional fixed-volume financial transmission rights (FTRs), these fixed-volume FTRs do not effectively hedge basis risk for variable wind generation. More-effective hedging mechanisms may be required to support those generators most-impacted by congestion, and to promote continued investment in variable generation resources in congested markets.

17 WIND ENERGY↗

(abstract) Atmospheric Transmission Model Through Autonomous Visibility Measurement

Performance of deep space optical communications is impacted by atmospheric outages. By monitoring known stellar objects with calibrated telescopes, atmospheric attenuation statistics can be recorded. This paper describes a program to develop an atmospheric transmission model for optical communications by making automous visibility measurements of known stellar objects from three locations in the southwestern US. The data will be correlated and infused with weather data to establish the atmospheric transmission model. This model will be sent in link margin analysis for optical communications channels. The statistics will be updated on a quarterly basis and calibrated using data taken over a long period of time. This calibration is expected to allow extrapolation to other ground-based locations through use of global weather databases.

attenuation model↗

Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex, heavy and most importantly costly. This presentation paper presents a concept which overcomes these detrimental attributes by eliminating all of the phase array backend (including phase shifters). Instead, a wave velocity reconfigurable transmission line is used in a series fed array arrangement to allow phase shifting with one small (100mil) mechanical motion. Different configurations of the reconfigurable wave velocity transmission line are discussed and simulated and experimental results are presented.

Beam Scanning↗

Evaluation of MEMS-Based Wireless Accelerometer Sensors in Detecting Gear Tooth Faults in Helicopter Transmissions

The diagnostics capability of micro-electro-mechanical systems (MEMS) based rotating accelerometer sensors in detecting gear tooth crack failures in helicopter main-rotor transmissions was evaluated. MEMS sensors were installed on a pre-notched OH-58C spiral-bevel pinion gear. Endurance tests were performed and the gear was run to tooth fracture failure. Results from the MEMS sensor were compared to conventional accelerometers mounted on the transmission housing. Most of the four stationary accelerometers mounted on the gear box housing and most of the CI's used gave indications of failure at the end of the test. The MEMS system performed well and lasted the entire test. All MEMS accelerometers gave an indication of failure at the end of the test. The MEMS systems performed as well, if not better, than the stationary accelerometers mounted on the gear box housing with regards to gear tooth fault detection. For both the MEMS sensors and stationary sensors, the fault detection time was not much sooner than the actual tooth fracture time. The MEMS sensor spectrum data showed large first order shaft frequency sidebands due to the measurement rotating frame of reference. The method of constructing a pseudo tach signal from periodic characteristics of the vibration data was successful in deriving a TSA signal without an actual tach and proved as an effective way to improve fault detection for the MEMS.