Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “total correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Quantification of electron correlation for approximate quantum calculations

State-of-the-art many-body wave function techniques rely on heuristics to achieve high accuracy at an attainable computational cost to solve the many-body Schrödinger equation. By far, the most common property used to assess accuracy has been the total energy; however, total energies do not give a complete picture of electron correlation. In this work, we assess the von Neumann entropy of the one-particle reduced density matrix (1-RDM) to compare selected configuration interaction (CI), coupled cluster, variational Monte Carlo, and fixed-node diffusion Monte Carlo for benchmark hydrogen chains. A new algorithm, the circle reject method, is presented, which improves the efficiency of evaluating the von Neumann entropy using quantum Monte Carlo by several orders of magnitude. The von Neumann entropy of the 1-RDM and the eigenvalues of the 1-RDM are shown to distinguish between the dynamic correlation introduced by the Jastrow and the static correlation introduced by determinants with large weights, confirming some of the lore in the field concerning the difference between the selected CI and Slater–Jastrow wave functions.

Chemistry↗

The Non-Gaussian Nature of Prostate Motion Based on Real-Time Intrafraction Tracking

Purpose: The objective of this work is to test the validity of the Gaussian approximation for prostate motion through characterization of its spatial distribution. Methods and Materials: Real-time intrafraction prostate motion was observed using Calypso 4-dimensional (4D) nonradioactive electromagnetic tracking system. We report the results from a total of 1024 fractions from 31 prostate cancer patients. First, the correlation of prostate motion in right/left (RL), anteroposterior (AP), and superoinferior (SI) direction were determined using Pearson's correlation of coefficient. Then the spatial distribution of prostate motion was analyzed for individual fraction, individual patient including all fractions, and all patients including all fractions. The displacement in RL, AP, SI, oblique, or total direction is fitted into a Gaussian distribution, and a Lilliefors test was used to evaluate the validity of the hypothesis that the displacement is normally distributed. Results: There is high correlation in AP/SI direction (61% of fractions with medium or strong correlation). This is consistent with the longitudinal oblique motion of the prostate, and likely the effect from respiration on an organ confined within the genitourinary diaphragm with the rectum sitting posteriorly and bladder sitting superiorly. In all directions, the non-Gaussian distribution is more common for individual fraction, individual patient including all fractions, and all patients including all fractions. The spatial distribution of prostate motion shows an elongated shape in oblique direction, indicating a higher range of motion in the AP and SI directions. Conclusions: Our results showed that the prostate motion is highly correlated in AP and SI direction, indicating an oblique motion preference. In addition, the spatial distribution of prostate motion is elongated in an oblique direction, indicating that the organ motion dosimetric modeling using Gaussian kernel may need to be modified to account for the particular organ motion character of prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RELATION BETWEEN THE CORONAL MASS EJECTION ACCELERATION AND THE NON-THERMAL FLARE CHARACTERISTICS

We investigate the relationship between the main acceleration phase of coronal mass ejections (CMEs) and the particle acceleration in the associated flares as evidenced in Reuven Ramaty High Energy Solar Spectroscopic Imager non-thermal X-rays for a set of 37 impulsive flare-CME events. Both the CME peak velocity and peak acceleration yield distinct correlations with various parameters characterizing the flare-accelerated electron spectra. The highest correlation coefficient is obtained for the relation of the CME peak velocity and the total energy in accelerated electrons (c = 0.85), supporting the idea that the acceleration of the CME and the particle acceleration in the associated flare draw their energy from a common source, probably magnetic reconnection in the current sheet behind the erupting structure. In general, the CME peak velocity shows somewhat higher correlations with the non-thermal flare parameters than the CME peak acceleration, except for the spectral index of the accelerated electron spectrum, which yields a higher correlation with the CME peak acceleration (c Almost-Equal-To -0.6), indicating that the hardness of the flare-accelerated electron spectrum is tightly coupled to the impulsive acceleration process of the rising CME structure. We also obtained high correlations between the CME initiation height h{sub 0} and the non-thermal flare parameters, with the highest correlation of h{sub 0} to the spectral index {delta} of flare-accelerated electrons (c Almost-Equal-To 0.8). This means that CMEs erupting at low coronal heights, i.e., in regions of stronger magnetic fields, are accompanied by flares that are more efficient at accelerating electrons to high energies. In the majority of events ({approx}80%), the non-thermal flare emission starts after the CME acceleration, on average delayed by Almost-Equal-To 6 minutes, in line with the standard flare model where the rising flux rope stretches the field lines underneath until magnetic reconnection sets in. We find that the current sheet length at the onset of magnetic reconnection is 21 {+-} 7 Mm. The flare hard X-ray peaks are well synchronized with the peak of the CME acceleration profile, and in 75% of the cases they occur within {+-}5 minutes. Our findings provide strong evidence for the tight coupling between the CME dynamics and the particle acceleration in the associated flare in impulsive events, with the total energy in accelerated electrons being closely correlated with the peak velocity (and thus the kinetic energy) of the CME, whereas the number of electrons accelerated to high energies is decisively related to the CME peak acceleration and the height of the pre-eruptive structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Pion number fluctuations and correlations in a statistical system with fixed isospin

The statistical system of pions with zero total isospin is studied. The suppression effects for the average yields due to isospin conservation are the same for {pi}{sup 0}, {pi}{sup +}, and {pi}{sup -}. However, a behavior of the corresponding particle number fluctuations are different. For neutral pions there is the enhancement of the fluctuations, whereas for charged pions the isospin conservation suppresses fluctuations. The correlations between the numbers of charged and neutral pions are observed for finite systems. This causes a maximum of the total pion number fluctuations for small systems. The thermodynamic limit values for the scaled variances of neutral and charged pions are calculated. The enhancements of the fluctuations due to Bose statistics are found and discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MINUTE-SCALE RAPID VARIABILITY OF THE OPTICAL POLARIZATION IN THE NARROW-LINE SEYFERT 1 GALAXY PMN J0948+0022

We report on optical photopolarimetric results of the radio-loud narrow-line Seyfert 1 (RL-NLSy1) galaxy PMN J0948+0022 on 2012 December to 2013 February triggered by flux enhancements in the near infrared and γ-ray bands. With the one-shot polarimetry of the Hiroshima One-shot Wide field Polarimeter installed on the Kanata Telescope, we detected very rapid variability in the polarized-flux (PF) light curve on MJD 56281 (2012 December 20). The rise and decay times were about 140 s and 180 s, respectively. The polarization degree (PD) reached 36% ± 3% at the peak of the short-duration pulse, while the polarization angle remained almost constant. In addition, temporal profiles of the total flux and PD showed highly variable but well correlated behavior and discrete correlation function analysis revealed that no significant time lag of more than 10 minutes was present. The high PD and minute-scale variability in PF provides clear evidence of synchrotron radiation from a very compact emission region of ∼10{sup 14} cm size with a highly ordered magnetic field. Such micro-variability of polarization is also observed in several blazar jets, but its complex relation between total flux and PD are explained by a multi-zone model in several blazars. The implied single emission region in PMN J0948+0022 might reflect a difference of jets between RL-NLSy1s and blazars.

79 ASTRONOMY AND ASTROPHYSICS↗

Land-atmosphere coupling and climate prediction over the U.S. Southern Great Plains

Biases in land-atmosphere coupling in climate models can contribute to climate prediction biases, but land models are rarely evaluated in the context of this coupling. Here, we tested land-atmosphere coupling and explored effects of land surface parameterizations on climate prediction in a single-column version of the National Center for Atmospheric Research Community Earth System Model (CESM1.2.2) and an off-line Community Land Model (CLM4.5). The correlation between leaf area index (LAI) and surface evaporative fraction (ratio of latent to total turbulent heat flux) was substantially underpredicted compared to observations in the U.S. Southern Great Plains, while the correlation between soil moisture and evaporative fraction was overpredicted by CLM4.5. To estimate the impacts of these errors on climate prediction, we modified CLM4.5 by prescribing observed LAI, increasing soil resistance to evaporation, increasing minimum stomatal conductance, and increasing leaf reflectance. The modifications improved the predicted soil moisture-evaporative fraction (EF) and LAI-EF correlations in off-line CLM4.5 and reduced the root-mean-square error in summer 2 m air temperature and precipitation in the coupled model. The modifications had the largest effect on prediction during a drought in summer 2006, when a warm bias in daytime 2 m air temperature was reduced from +6°C to a smaller cold bias of -1.3°C, and a corresponding dry bias in precipitation was reduced from -111 mm to -23 mm. The role of vegetation in droughts and heat waves is underpredicted in CESM1.2.2, and improvements in land surface models can improve prediction of climate extremes.

54 ENVIRONMENTAL SCIENCES↗

Debris Disk Results from the Gemini Planet Imager Exoplanet Survey's Polarimetric Imaging Campaign

We report the results of a ∼4 yr direct imaging survey of 104 stars to resolve and characterize circumstellar debris disks in scattered light as part of the Gemini Planet Imager (GPI) Exoplanet Survey. We targeted nearby (≲150 pc), young (≲500 Myr) stars with high infrared (IR) excesses (L {sub IR}/L {sub ⋆} > 10{sup −5}), including 38 with previously resolved disks. Observations were made using the GPI high-contrast integral field spectrograph in H-band (1.6 μm) coronagraphic polarimetry mode to measure both polarized and total intensities. We resolved 26 debris disks and 3 protoplanetary/transitional disks. Seven debris disks were resolved in scattered light for the first time, including newly presented HD 117214 and HD 156623, and we quantified basic morphologies of five of them using radiative transfer models. All of our detected debris disks except HD 156623 have dust-poor inner holes, and their scattered-light radii are generally larger than corresponding radii measured from resolved thermal emission and those inferred from spectral energy distributions. To assess sensitivity, we report contrasts and consider causes of nondetections. Detections were strongly correlated with high IR excess and high inclination, although polarimetry outperformed total intensity angular differential imaging for detecting low-inclination disks (≲70°). Based on postsurvey statistics, we improved upon our presurvey target prioritization metric predicting polarimetric disk detectability. We also examined scattered-light disks in the contexts of gas, far-IR, and millimeter detections. Comparing H-band and ALMA fluxes for two disks revealed tentative evidence for differing grain properties. Finally, we found no preference for debris disks to be detected in scattered light if wide-separation substellar companions were present.

79 ASTRONOMY AND ASTROPHYSICS↗

Initial correlations in open-systems dynamics: The Jaynes-Cummings model

Employing the trace distance as a measure for the distinguishability of quantum states, we study the influence of initial correlations on the dynamics of open systems. We concentrate on the Jaynes-Cummings model for which the knowledge of the exact joint dynamics of system and reservoir allows the treatment of initial states with arbitrary correlations. As a measure for the correlations in the initial state we consider the trace distance between the system-environment state and the product of its marginal states. In particular, we examine the correlations contained in the thermal equilibrium state for the total system, analyze their dependence on the temperature and on the coupling strength, and demonstrate their connection to the entanglement properties of the eigenstates of the Hamiltonian. A detailed study of the time dependence of the distinguishability of the open system states evolving from the thermal equilibrium state and its corresponding uncorrelated product state shows that the open system dynamically uncovers typical features of the initial correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An ab initio study of the electronic structure and optical properties of CdS{sub 1-x}Te{sub x} alloys

The structural, electronic and optical properties of cubic CdS{sub 1-x}Te{sub x} alloys, with Te-concentrations varying from 0% up to 100% are investigated. The calculations are based on the total-energy calculations using the full potential-linearized augmented plane wave (FP-LAPW) method. The exchange and correlation potential is treated by the generalized-gradient approximation (GGA) for the total-energy calculations, while for electronic properties in addition to that the Engel-Vosko (EV-GGA) formalism was also applied. The ground state properties for all Te-concentrations are presented. The optical dielectric constant is also determined for both the binary and their related ternary alloys. (author)

36 MATERIALS SCIENCE↗

An alpha-synuclein MRM assay with diagnostic potential for Parkinson's disease and monitoring disease progression

Aim: The alpha-synuclein (α-syn) level in human cerebrospinal fluid (CSF), as measured by immunoassays, is promising as a Parkinson’s disease (PD) biomarker. However, the levels of total α-syn are inconsistent among studies with large cohorts and different measurement platforms. Total α-syn level also does not correlate with disease severity or progression. Here, we developed a highly sensitive Multiple Reaction Monitoring (MRM) method to measure absolute CSF α-syn peptide concentrations without prior enrichment or fractionation, aiming to discover new candidate biomarkers. Results: Six peptides covering 73% of protein sequence were reliably identified, and two were consistently quantified in cross-sectional and longitudinal cohorts. Absolute concentration of α-syn in human CSF was determined to be 2.1ng/mL. A unique α-syn peptide, TVEGAGSIAAATGFVK (81-96), displayed excellent correlation with previous immunoassay results in two independent PD cohorts (p < 0.001), correlated with disease severity, and its changes significantly tracked the disease progression longitudinally. Conclusions: An MRM assay to quantify human CSF α-syn was developed and optimized. Sixty clinical samples from cross-sectional and longitudinal PD cohorts were analyzed with this approach. Although further larger-scale validation is needed, the results suggest that α-syn peptide could serve as a promising biomarker in PD diagnosis and progression.

60 APPLIED LIFE SCIENCES↗

Correlation of Peripheral Vein Tumour Marker Levels, Internal Iliac Vein Tumour Marker Levels and Radical Prostatectomy Specimens in Patients with Prostate Cancer and Borderline High Prostate-Specific Antigen: A Pilot Study

PurposeTo correlate prostate-specific antigen (PSA), free to total PSA percentage (fPSA%) and prostatic acid phosphatase (PAP) levels from peripheral and pelvic venous samples with prostatectomy specimens in patients with prostate adenocarcinoma and borderline elevation of PSA.Materials and MethodsIn this prospective institutional review board approved study, 7 patients with biopsy proven prostate cancer had a venous sampling procedure prior to prostatectomy (mean 3.2 days, range 1–7). Venous samples were taken from a peripheral vein (PVS), the right internal iliac vein, a deep right internal iliac vein branch, left internal iliac vein and a deep left internal iliac vein branch. Venous sampling results were compared to tumour volume, laterality, stage and grade in prostatectomy surgical specimens.ResultsMean PVS PSA was 4.29, range 2.3–6 ng/ml. PSA and PAP values in PVS did not differ significantly from internal iliac or deep internal iliac vein samples (p > 0.05). fPSA% was significantly higher in internal iliac (p = 0.004) and deep internal iliac (p = 0.003) vein samples compared to PVS. One of 7 patients had unilateral tumour only. This patient, with left–sided tumour, had a fPSA% of 6, 6, 6, 14 and 12 in his peripheral, right internal iliac, deep right internal iliac branch, left internal iliac and deep left internal iliac branch samples respectively. There were no adverse events.ConclusionfPSA%, unlike total PSA or PAP, is significantly higher in pelvic vein compared to peripheral vein samples when prostate cancer is present. Larger studies including patients with higher PSA values are warranted to further investigate this counterintuitive finding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An assessment of the safety, hemodynamic response, and diagnostic accuracy of commonly used vasodilator stressors in patients with severe aortic stenosis

Background: Increasing numbers of patients are undergoing transcatheter aortic valve replacement, which often involves assessment of coronary artery disease ischemic burden. The safety and diagnostic accuracy of vasodilator stress agents in patients with severe aortic stenosis (AS) undergoing SPECT myocardial perfusion imaging (MPI) has not been established. Methods: Patients with severe AS (valve area <1 cm{sup 2}) on echocardiography who underwent vasodilator stress SPECT MPI at two centers were identified. Patients with aortic valve intervention prior to MPI or who underwent concurrent exercise during stress testing were excluded. AS patients were matched to controls without AS based on age, gender, BMI, ejection fraction, and stress agent. Symptoms, serious adverse events, hemodynamic response, and correlation to invasive angiography were assessed. Results: A total of 95 cases were identified with 45% undergoing regadenoson, 31% dipyridamole, and 24% adenosine stress. A significant change in systolic blood pressure (BP), cases vs controls, was observed with adenosine [−17.9 ± 20.1 vs −2.6 ± 24.9 P = .03)], with a trend toward significance with regadenoson [−16.8 ± 20.3 vs −9.4 ± 17.9 (P = .08)] and dipyridamole [−17.8 ± 20.6 vs -9.0 ± 12.1 (P = .05)]. The change in heart rate was significantly different only for adenosine [5.3 ± 16.8 vs 14.2 ± 10.8 (P = .04)]. Overall, 45% of cases vs 24% of controls (P = .004) had a >20 mmHg decrease in systolic BP. Age, BMI, and resting systolic BP were related to a >20 mmHg decrease in systolic BP on univariate analysis, although only higher resting systolic BP was a predictor on multivariate analysis. In 33 patients who underwent angiography, the sensitivity, specificity, and diagnostic accuracy of vasodilator stress MPI was 77%, 69%, and 73%, respectively. No serious adverse events occurred in the severe AS patients. Conclusion: Severe AS patients are more likely to have a hemodynamically significant decrease in systolic BP with vasodilator stress. There were no serious adverse events in this severe AS cohort with good diagnostic performance of MPI compared to angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theory of four-dimensional fractional quantum Hall states

We propose a pseudo-potential Hamiltonian for the Zhang-Hu's generalized fractional quantum Hall states to be the exact and unique ground states. Analogously to Laughlin's quasi-hole (quasi-particle), the excitations in the generalized fractional quantum Hall states are extended objects. They are vortex-like excitations with fractional charges +(-)1/m{sup 3} in the total configuration space CP{sup 3}. The density correlation function of the Zhang-Hu states indicates that they are incompressible liquid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvements to sample processing and measurement to enable more widespread environmental application of tritium

Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.

low background↗

A study on the entrainment and mixing process in the continental stratocumulus clouds measured during the RACORO campaign

Entrainment and mixing processes and their effects on cloud microphysics in the continental stratocumulus clouds observed in Oklahoma during the RACORO campaign are analyzed in the frame of homogeneous and inhomogeneous mixing concepts by combining the approaches of microphysical correlation, mixing diagram, and transition scale (number). A total of 110 horizontally penetrated cloud segments is analyzed in this paper. Mixing diagram and cloud microphysical relationship analyses show homogeneous mixing trait of positive relationship between liquid water content (L) and mean volume of droplets (V) (i.e., smaller droplets in more diluted parcel) in most cloud segments. Relatively small temperature and humidity differences between the entraining air from above the cloud top and cloudy air and relatively large turbulent dissipation rate are found to be responsible for this finding. The related scale parameters (i.e., transition length and transition scale number) are relatively large, which also indicates high likelihood of homogeneous mixing. Finally, clear positive relationship between L and vertical velocity (W) for some cloud segments is suggested to be evidence of vertical circulation mixing, which may further enhance the positive relationship between L and V created by homogeneous mixing.

54 ENVIRONMENTAL SCIENCES↗

Susceptibility to quantum dot induced lung inflammation differs widely among the Collaborative Cross founder mouse strains

Quantum dots (QDs) are engineered semiconductor nanoparticles with unique physicochemical properties that make them potentially useful in clinical, research and industrial settings. However, a growing body of evidence indicates that like other engineered nanomaterials, QDs have the potential to be respiratory hazards, especially in the context of the manufacture of QDs and products containing them, as well as exposures to consumers using these products. The overall goal of this study was to investigate the role of mouse strain in determining susceptibility to QD-induced pulmonary inflammation and toxicity. Male mice from 8 genetically diverse inbred strains (the Collaborative Cross founder strains) were exposed to CdSe–ZnS core–shell QDs stabilized with an amphiphilic polymer. QD treatment resulted in significant increases in the percentage of neutrophils and levels of cytokines present in bronchoalveolar lavage fluid (BALF) obtained from NOD/ShiLtJ and NZO/HlLtJ mice relative to their saline (Sal) treated controls. Cadmium measurements in lung tissue indicated strain-dependent differences in disposition of QDs in the lung. Total glutathione levels in lung tissue were significantly correlated with percent neutrophils in BALF as well as with lung tissue Cd levels. Our findings indicate that QD-induced acute lung inflammation is mouse strain dependent, that it is heritable, and that the choice of mouse strain is an important consideration in planning QD toxicity studies. These data also suggest that formal genetic analyses using additional strains or recombinant inbred strains from these mice could be useful for discovering potential QD-induced inflammation susceptibility loci. - Highlights: • Quantum dot acute lung inflammation was evaluated in a multi-strain mouse model. • QD disposition differed across 8 Collaborative Cross (CC) founder strains. • Neutrophil and cytokine levels in BALF were also mouse strain dependent. • NOD/ShiLtJ, NZO/HlLtJ, and A/J were more sensitive to QDs than C57BL/6J mice. • The cytokines KC and Mip1α were strongly correlated with Cd and BALF neutrophils.

60 APPLIED LIFE SCIENCES↗

Electronic Energies Are Not Enough: An Ion Mobility-Aided, Quantum Chemical Benchmark Analysis of H + GPGG Conformers

Peptides and proteins exist not as single, lowest energy structures but as ensembles of states separated by small barriers. In order to study these species we must be able to correctly identify their gas phase conformational distributions, and ion mobility spectrometry (IMS) has arisen as an experimental method for assessing the gas phase energetics of flexible peptides. Here, we present a thorough exploration and benchmarking of the low energy conformers of the small, hairpin peptide H+ GPGG with the aid of ion mobility spectrometry against a wide swath of density functionals (35 dispersion-corrected and uncorrected functionals represented by 21 unique exchange–correlation functionals) and wave function theory methods (15 total levels of theory). The three experimentally resolved IMS peaks were found to correspond to three distinct pairs of conformers, each pair composed of species differing only by the chair or boat configuration of the proline. Two of the H+ GPGG conformer pairs possess a cis configuration about the Pro–Gly1 peptide bond while the other adopts a trans configuration. While the experimental spectrum reports a higher intensity for the cis-1 conformer than the trans conformer, 13 WFT levels of theory, including a complete basis set CCSD(T) extrapolation, obtain trans to be favored in terms of the electronic energy. This same effect is seen in 14 of the 18 dispersion-corrected density functionals studied, whereas the remaining 17 functionals show more variety. Only when Gibbs free energies are considered do the WFT methods and dispersion-corrected functionals reflect the experimental distribution. CAM-B3LYP-D3BJ emerges as the best-performing density functional, matching the experimental distribution and the CCSD(T)/CBS relative energies within 6%. Further analysis reveals the trans conformer to be favored electronically, but entropically disfavored, leading to the experimental preference of the cis-1 conformer. Furthermore, these results highlight the danger in considering only the electronic energies, which is common practice in electronic structure theory predictions of conformational energy distributions. Additionally, the effects of temperature and scaling of the frequencies used in obtaining the Gibbs free energies are explored.

Energy↗

Photon Counting Data Analysis: Application of the Maximum Likelihood and Related Methods for the Determination of Lifetimes in Mixtures of Rose Bengal and Rhodamine B

It is often convenient to know the minimum amount of data needed in order to obtain a result of desired accuracy and precision. It is a necessity in the case of subdiffraction-limited microscopies, such as stimulated emission depletion (STED) microscopy, owing to the limited sample volumes and the extreme sensitivity of the samples to photobleaching and photodamage. We present a detailed comparison of probability-based techniques (the maximum likelihood method and methods based on the binomial and the Poisson distributions) with residual minimization-based techniques for retrieving the fluorescence decay parameters for various two-fluorophore mixtures, as a function of the total number of photon counts, in time-correlated, single-photon counting experiments. The probability-based techniques proved to be the most robust (insensitive to initial values) in retrieving the target parameters and, in fact, performed equivalently to 2-3 significant figures. This is to be expected, as we demonstrate that the three methods are fundamentally related. Furthermore, methods based on the Poisson and binomial distributions have the desirable feature of providing a bin-by-bin analysis of a single fluorescence decay trace, which thus permits statistics to be acquired using only the one trace for not only the mean and median values of the fluorescence decay parameters but also for the associated standard deviations. Lastly, these probability-based methods lend themselves well to the analysis of the sparse data sets that are encountered in subdiffraction-limited microscopies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗