Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time step”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A framework for multirate time integration of interface-coupled problems

The research described here was performed as part of the DOE SciDAC project Coupling Approaches for Next Generation Architectures (CANGA). A framework was developed for the derivation of novel algorithms for the multirate time integration of two-component systems coupled across an interface between spatial domains. The multirate aspect means that different time steps are allowed by each component integrator. The framework provides a way to construct multirate integrators with desirable properties related to stability, accuracy and preservation of system invariants. This report describes the framework and summarizes the major results, examples and research products.

97 MATHEMATICS AND COMPUTING↗

Sierra/SolidMechanics 5.16 Capabilities in Development Manual

This user’s guide documents capabilities in Sierra/SolidMechanics which remain “in-development” and thus are not tested and hardened to the standards of capabilities listed in Sierra/SM 5.16 User’s Guide. Capabilities documented herein are available in Sierra/SM for experimental use only until their official release. These capabilities include, but are not limited to, novel discretization approaches such as the conforming reproducing kernel (CRK) method, numerical fracture and failure modeling aids such as the extended finite element method (XFEM) and J-integral, explicit time step control techniques, dynamic mesh rebalancing, as well as a variety of new material models and finite element formulations.

97 MATHEMATICS AND COMPUTING↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Continued performance improvement and integration of MOOSE's thermal-hydraulics capabilities (M3 Milestone Report)

This work introduces performance, robustness and workflow improvements to Multiphysics Object-Oriented Simulation Environment (MOOSE)-based thermal-hydraulics solvers. It presents work related to the acceleration of segregated fluid dynamics algorithms, which show approximately a factor of 10 speedup compared to the preceding implementation. Additionally, we discuss approaches to use advanced, Schurr complement-based, field split preconditioners for monolithic solution algorithms relying on the finite volume method. The presence of the Rhie-Chow interpolation makes the utilization of this preconditioner challenging, but the results indicate that for a moderately large problem a factor of 3.4 speedup can be achieved in conjunction with a factor of 3.5 reduction in memory usage. Furthermore, we introduce several pseudo-time stepping approaches to MOOSE for the robust convergence to steady-state solutions when steady-state solves don't converge due to the initial guesses being too far from the solution in Newton's method. Every MOOSE-based application has access this algorithm and can benefit from its use. Moreover, several new avenues have been presented for importing meshes from commercial software which make meshing easier. Lastly, the Component system within the Thermal-Hydraulics Module (THM) of MOOSE is abstracted by separating geometry- and physics-related properties.

97 MATHEMATICS AND COMPUTING↗

Performance Results on CPU/GPU Exascale Architectures for OMEGA: The Ocean Model for E3SM Global Applications

The US Department of Energy (DOE) conducts climate simulations on some of the world’s largest supercomputers. These exascale machines use heterogeneous architectures with both CPUs and GPUs, and scientific codes must adapt to make full use of this computing power. Los Alamos National Lab is developing Omega: The Ocean Model for E3SM Global Applications, which is specifically designed for modern exascale computers. It uses external libraries that have been optimized for a variety of architectures to run on different supercomputers. Omega is an unstructured-mesh ocean model based on TRiSK numerical methods. It will be the new ocean component of the DOE’s Energy Exascale Earth System Model (E3SM). The algorithms in Omega follow those of the current ocean component, MPAS-Ocean, but it will be written in C++ rather than Fortran to take advantage of the Kokkos performance portability library. Omega spatial operators are written as Kokkos kernels to run efficiently on both CPUs and GPUs. Work on Omega began in 2023 with a new C++ framework for unstructured mesh partitioning, halo exchanges, parallel IO, and Kokkos interfaces. The current version, Omega-0, is being developed to solve the shallow water equations and at present includes all of the tendency terms but not time stepping. Here we share the results of Omega-0 verification and performance testing. Verification includes unit tests implemented with CTest as well as convergence tests in Polaris, an in-house python package with a large suite of test problems. Performance tests compare simulations conducted on CPUs versus GPUs and across different architectures: tests are run on Frontier, which has AMD “Optimized 3rd Gen EPYC” CPUs and AMD MI250X GPUs, as well as Perlmutter, which is composed of AMD EPYC 7763 CPUs and NVIDIA A100 GPUs.

58 GEOSCIENCES↗

Implementation of Detailed Polyethylene Pyrolysis Kinetics into CFD Simulations using Machine Learning

Municipal solid waste (MSW) and waste plastics have received significant attention due to the issues of waste generation and storage, as well as their potential as an energy resource. High-density polyethylene (HDPE) makes up a large portion of plastic waste and has been the subject of several conversion studies. However, the mechanisms associated with converting HDPE through pyrolysis and gasification are extensive and complex making them difficult to implement into high-fidelity computational fluid dynamic (CFD) simulations. For this project, a primary pyrolysis mechanism containing 42 unique species and 737 heterogeneous reactions was used to generate kinetic data over a range of operating conditions. A machine learning (ML) model was developed to replicate the results of the detailed pyrolysis mechanism while significantly increasing the computational efficiency. A deep operator network (DeepONet) architecture was adopted to train the model using time steps relevant to CFD simulations. The ML used physics-based loss functions to ensure mass conservation. The ML model has been deployed in simple MFiX CFD simulations, single particle, and an experimental drop tube reactor, and has shown promising performance compared to the original scheme.

Houston, Ross↗

Development of a machine learning model for polyethylene pyrolysis using a detailed reaction mechanism

Waste plastics have recently received significant attention as the issue of waste generation continues to increase. Thermal conversion processes, such as pyrolysis and gasification, are attractive potential technologies for utilizing waste plastics and reducing overall waste generation. Efficient utilization of plastics requires a detailed understanding of the conversion process such as pyrolysis and gasification. However, a mechanistic understanding of these processes lead to large and complex kinetic schemes that are not suited for large-scale and long-time simulation methods. Currently, most modeling approaches for pyrolysis and gasification rely on globally lumped, simplified kinetic schemes that provide results that are classified by their product type and not individual species, which limit the level of fidelity achieved via modeling. A machine learning (ML) model has been developed for the primary reactions of high-density polyethylene (HDPE) in an attempt to increase computational efficiency while still maintaining a high level of detail and accuracy. The ML model is trained on a detailed reaction mechanism containing 42 total species and 737 chemical reactions. A DeepONet branch and trunk architecture was adopted to train the model using time-steps relevant to computational fluid dynamics simulations. The ML used physics-informed loss functions to ensure mass conservation. The surrogate model has been deployed in simple MFiX CFD simulations, single particle and an experimental drop tube reactor, and has shown promising performance compared to the original scheme.

Houston, Ross↗

Improving North American Wildfire Prediction by Integrating a Machine-Learning Fire Model in a Land Surface Model

Wildfires have shown increasing trends in both frequency and severity across the Contiguous United States (CONUS). However, process-based fire models have difficulties in accurately simulating the burned area over the CONUS due to a simplification of the physical process and cannot capture the interplay among fire, ignition, climate, and human activities. The deficiency of burned area simulation deteriorates the description of fire impact on energy balance, water budget, and carbon fluxes in the Earth System Models (ESMs). Alternatively, machine learning (ML) based fire models, which capture statistical relationships between the burned area and environmental factors, have shown promising burned area predictions and corresponding fire impact simulation. We develop a hybrid framework (ML4Fire-XGB) that integrates a pretrained eXtreme Gradient Boosting (XGBoost) wildfire model with the Energy Exascale Earth System Model (E3SM) land model (ELM) version 2.1. A Fortran-C-Python deep learning bridge is adapted to support online communication between ELM and the ML fire model. Specifically, the burned area predicted by the ML-based wildfire model is directly passed to ELM to adjust the carbon pool and vegetation dynamics after disturbance, which are then used as predictors in the ML-based fire model in the next time step. Evaluated against the historical burned area from Global Fire Emissions Database 5 from 2001-2020, the ML4Fire-XGB model outperforms process-based fire models in terms of spatial distribution and seasonal variations. Sensitivity analysis confirms that the ML4Fire-XGB well captures the responses of the burned area to rising temperatures. The ML4Fire-XGB model has proved to be a new tool for studying vegetation-fire interactions, and more importantly, enables seamless exploration of climate-fire feedback, working as an active component in E3SM.

54 ENVIRONMENTAL SCIENCES↗

Creation of a Weather Drivers Test Suite for Inclusion in ASHRAE Standard 140

Weather conditions are an important boundary condition for building performance simulation (BPS) calculations. For existing test cases in ASHRAE Standard 140 "Method of Test for Evaluating Building Performance Simulation Software" (ANSI/ASHRAE 2020), it was assumed that the software being tested could adequately read and interpret the weather data in the provided standard weather files. As differences between the programs have been reduced and as more programs have shifted to sub-hourly time steps this assumption has become more stretched. To address these concerns a new test suite testing a program's ability to read and interpret the data from a standard weather file was developed. The purpose of the test suite is to test the use of the typical data used from standard weather files.

54 ENVIRONMENTAL SCIENCES↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selective mass scaling for single-layer thick shell elements in DYNA3D

Hexahedral elements can be adapted to model thin and moderately thick structures by neglecting the coupling of through-thickness stress, resulting in a fully three-dimensional, but simplified, state of stress. These specialized elements, often referred to as “thick” or “solid” shells, are generally employed to model thin-walled structures using continuum mechanics-based material models. In explicit dynamics simulations, where computational speed is important, these elements are integrated with a single quadrature point and a set of anti-hourglassing (stabilizing) forces. Thick shells, by definition, have a thickness dimension smaller than their in-plane dimensions, and this small thickness often determines the stable time step size in simulations, despite the mechanics being approximated. To alleviate this limitation while retaining the relevant dynamics of thin-walled structures, selective mass scaling (SMS), or selective mass “augmentation,” has been proposed in the literature. In this technical report, we explore the application of SMS to single-layer thick shells in the simulation software DYNA3D.

42 ENGINEERING↗

2024 Incubator Final Report: Active Hybrid Mooring

This Incubator project has defined and developed a representation of an active hybrid mooring (AHM) system in Simulink to assess whether the speed and accuracy of AHM is sufficient to warrant further investigation in a larger project. We first built a representative mooring system for the VolturnUS-S 15MW floating offshore wind turbine (FOWT) in 1,000-meter water depth to provide baseline loads and displacements needed in the AHM system, with the results showing off-the-shelf actuators would be practical. We then defined model configurations for the numerical and physical substructures, using standalone MoorDyn v2 with a novel input strategy and chained hydraulic actuators represented in Simulink Simscape, respectively. The remainder of the project has focused on verifying the existing models for speed and accuracy against OpenFAST simulations, increasing their complexity to enable six degree of freedom (6DOF) operation, and connecting the numerical and physical substructures into a single holistic model. The verification phase of the project has shown promising results, though further refinement is needed to resolve accuracy discrepancies and for robust performance across a wider range of metocean conditions. The numerical model we developed is computationally stable and operates faster than real time using a time step of 0.01 seconds or shorter, indicating the model is likely fast enough for our AHM design to operate successfully. Additionally, the Simscape model of a hydraulic actuator operates with less than 0.3% relative error when actuating mooring loads from an OpenFAST simulation of the VolturnUS-S 1,000-meter mooring system. The aforementined refinements will be performed in the next year as a Continuing Incubator, with key remaining tasks include programming the predictor-corrector loop to minimize movement error, testing against more complex nonlinear wave cases, and expanding to enable loads from connected shared mooring lines.

17 WIND ENERGY↗

Open library of g-functions for 34,321 configurations

Thermal response functions, known as g-functions, are commonly used in ground heat exchanger design tools and whole building energy simulation programs to simulate the ground heat exchanger performance. Calculation of g-functions can be quite computationally time-consuming, particularly as the number of boreholes gets large. However, once the g-function is computed, the actual simulation time can be quite short, particularly if a hybrid time-step (Cullin and Spitler 2011) approach is used. Because of this, pre-computed g-function libraries are commonly used in design tools and building simulation tools. This paper describes development of a new, publicly available library containing g-functions for 34,321 borehole field configurations; for each configuration, gfunctions are provided for 5 depths to allow interpolation between different borehole-to-height ratios. The available configurations include configurations in standard shapes: lines, rectangles, open rectangles, L-shapes, and U-shapes. It also includes new configurations: C-shapes, lopsided-U-shapes, and zoned rectangles, which are rectangular configurations with different interior and perimeter spacing of the boreholes.

Spitler, Jeffery↗