Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Ground-Active Arthropod Diversity Under Energycane and Biomass Sorghum Production

Energycane and biomass sorghum are two of the most promising cellulosic energy crops in the southeastern US. Research on these two energy crops has focused mainly on biomass production, and there is a lack of knowledge on their ability to promote biodiversity and ecosystem services. This paper presents results from a comprehensive study on ground-active arthropod diversity in seven sites across five states in the southeastern US (Florida, Georgia, Louisiana, Mississippi, and Texas). Pitfall traps were deployed four times during each crop season for energycane, biomass sorghum, and a local reference conventional crop from 2020 to 2022. Arthropod abundance (individuals/(trap × day)) values were 4.9 ± 0.46, 3.7 ± 0.18, and 2.6 ± 0.16 (mean ± stderr) for conventional crops, biomass sorghum, and energycane, respectively, with a significant difference found only between conventional crops and energycane. Individuals were identified to arthropod orders, and Hill’s diversity indices were calculated based on the number of individuals in each arthropod order instead of the number of individuals in each arthropod species. Order-based arthropod richness values were 5.3, 5.2, and 4.8 for biomass sorghum, conventional crops, and energycane, with significant difference found only between biomass sorghum and energycane. There was no significant difference in the order-based Shannon diversity and Simpson diversity between the three crop types. The effective number of arthropod orders for the two energy crops decreased from 5.0 to 3.4 to 2.9 with increasing order of diversity from arthropod richness to Shannon diversity to Simpson diversity. The explained variability by environmental factors also decreased with increasing Hill’s order of diversity. The results from this study indicate no significant advantage in order-based arthropod diversity in growing biomass sorghum and energycane. This research fills a critical knowledge gap in understanding the impacts of cellulosic energy crop production on biodiversity and ecosystem services.

Yang, Yubin↗

STUDIES ON PIPELINE POLYETHYLENES IN HYDROGEN GAS ENVIRONMENTS USING IN-SITU AND EX-SITU CHARACTERIZATION METHODS

Polymeric materials are commonplace in the natural gas infrastructure as distribution pipes, coatings, seals, and gaskets. Under the auspices of the U.S. Department of Energy HyBlend program, one of the means to reduce greenhouse gas emissions is with replacing natural gas, either partially or completely, with hydrogen. This approach makes it imperative that we conduct near-term and long-term materials compatibility research in these relevant environments. Insights into the effects of hydrogen and hydrogen gas blends on polymer integrity can be gained through both ex-situ and in-situ analytical methods. Our work represented here highlights a study of the behavior of pipeline polyethylene (PE) materials, including HDPE (Dow 2490 and GDB50) and MDPE (Ineos and legacy Dupont Aldyl A), when exposed to hydrogen by means of in-situ X-ray scattering and ex-situ Raman spectroscopy techniques. Samples were tested in ex-situ hydrogen and argon gas environments and in-situ hydrogen environments to identify differences due to permeation and solubility of these gases. These methods complemented each other because Raman spectroscopy could capture permanent effects after materials were removed from gaseous environments, and in-situ X-ray scattering analysis collected real-time data to elucidate the impact of the gas environment on polymer microstructure. Data collected revealed that the aforementioned polymers did not show significant changes in crystallinity and microstructure under the exposure conditions tested. Our findings from these studies will help establish real-time effects caused by hydrogen gas transport through pipeline polyethylenes by way of its influence on polymer structure and chemistry, which is directly related to pipeline mechanical strength and longevity of service.

Hydrogen materials compatibility, Natural gas pipe↗

High-fidelity micromechanical modeling of the effects of defects on damage and creep behavior in single tow ceramic matrix composite

Despite the superior properties of ceramic matrix composites (CMCs), their fabrication process generates inevitable defects with high density that significantly influence material integrity and residual useful life. Recent efforts have focused on CMC property prediction and investigation of their different inelastic mechanisms, but very limited work exists on understanding the influence of defects on inelastic responses of CMCs. Here, we introduce a three-dimensional micromechanics computational framework that includes experimentally informed material microstructure and architectural variabilities to investigate CMC response in the presence of manufacturing-induced defects. A developed microstructure generation algorithm is used to generate the representative volume elements in the micromechanics models from complex material morphology information obtained from extensive characterization studies of C/SiNC and SiC/SiNC CMCs. A fracture mechanics-informed matrix damage model is reformulated, in which the model considers the growth of porosity and microcracks in the as-received material. A progressive fiber damage model as well as Orthotropic viscoplasticity creep formulation are also utilized for the study. This methodology is implemented within the micromechanics framework to investigate the complex temperature- and time-dependent load transfer and damage mechanisms of CMCs under operation loading conditions. The developed framework explores the influence of as-received defects on the damage and creep behavior in service conditions. It also provides new insights into the effect of size, shape, distribution, and location of these defects on material response. The framework is then calibrated with unidirectional CMC minicomposite results available in the literature.

36 MATERIALS SCIENCE↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Installation Assignment Durations and Patterns of Army Personnel

The purpose of this document is to report on the development of personnel assignment duration statistical metrics and statistical descriptions for groups of Army personnel aggregated by rank, career management field, and other descriptors for 32 Continental United States (CONUS) Army installations. This information can be used for generating evidence-based measures of personnel exposure times associated with environmental health considerations at the installation and career management field levels. Assignment duration statistical descriptions were developed to provide temporal metrics for groups of personnel at Army installations as foundational data to support a variety of assessments. Statistical results of personnel assignment durations at the installation level are provided in several formats. The 50th percentile assignment duration represents the median number of days personnel in groups aggregated by rank and career management field spend at the 32 CONUS Army installations in this study. Likewise, other duration percentiles (90th) and quartiles of assignment durations for groups aggregated by rank and career management field spend at each installation were developed. Assignment path analysis provide statistical descriptions of assignment durations at Army installations throughout increments of time (e.g., 5 years, 10 years). Key groupings of assignment paths were achieved by analyzing the duration of assignments at installations in chronological order from entry throughout specified increments of military service to generate the most common assignment paths across the 32 CONUS Army installations in this study. The developed assignment duration analytics and duration statistical descriptions provide foundational temporal metrics for groups of personnel at 32 CONUS Army installations to support a variety of assessments including those by human resource planners and environmental health specialists.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This National Energy Technology Laboratory (NETL) study addresses the conceptual design of greenfield pulverized coal (PC) plants intended for flexible rather than high capacity factor baseload operation. The United States has plentiful, low-cost natural gas resources - studies of aggressive decarbonization scenarios of the US energy sector suggest that the variability of carbon-free power can be economically addressed using dispatchable natural gas-fueled generation. Globally, natural gas resources are not as plentiful or low cost; consequently, some regions of the world are anticipated to continue to rely upon coal generation, even as they pursue decarbonization efforts. To support the increased utilization of variable renewable generation in these coal-dependent regions, plant designs must target low-capacity factor coal plants with increased emphasis on flexibility attributes such as start-up times, ramp rates, minimum load, and part-load heat rates. While much work has been performed on the improvement of the flexibility for existing coal plants originally designed for baseload service, little public literature exists on clean sheet design for flexible operation. This conceptual design study aims to define the features, performance characteristics, and costs for greenfield coal plants intended for flexible operation. Quantifying these characteristics provides critical information required by utility owners, grid planners, energy market modelers, and energy policy decision makers in coal-dependent regions of the world to better understand how coal-fired power plants can support a transition to low carbon generation.

20 FOSSIL-FUELED POWER PLANTS↗

Pumped Storage Hydropower Augmented with Pressurized Air: The Ground-Level Integrated Diverse Energy Storage (GLIDES) System — GLIDES System Configurations and Use Cases

Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.

13 HYDRO ENERGY↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensemble Manufacturing Techniques for Steam Turbine Components Across Length Scales

Faster design to manufacturing requirements were sought for steam turbine components to meet the changing demands of today’s power grid of improved efficiency through operating temperature increases and enhanced operational flexibility from baseload to cyclic operations. Advances in multiple advanced manufacturing (AM) process enabled redesign of turbine components for extreme environments with the potential to reduce cost. AM is of particular interest to improve component functionality, higher temperature capability, and superior durability in large scale steam turbine applications. AM methods have an immense potential to open-up the design space by working directly with the 3D model to produce near-net shapes, enable fast design-manufacturing iterations, thereby significantly reducing product cost and lead-time up to 25 % from current baseline. However, these benefits cannot be fully realized due to the potential for unknown AM processing defects and their resultant effect upon component performance in service. Siemens is partnering with Oak Ridge National Laboratory (ORNL), Electric Power Research Institute (EPRI), and Connecticut Center for Advanced Technology (CCAT) to advance the knowledge of complex process-material interactions for desired microstructures and properties that are closely interlinked to component geometries across different length scales. The proposed program utilized an ensemble of multidisciplinary technologies to accelerate the development of materials, high-throughput experiments for their qualification, and design flexibility/topology optimization for repair/redesign of components to address critical failure mechanisms for improved performance and increased reliability of existing power plant components. The proposed activities, if successfully demonstrated for identified components, will enable paradigm shift in customized manufacturing and accelerated qualification/certification towards increased steam turbine component durability, increased turbine efficiency, and reduced CO 2 emissions in load-following environments compared to today’s technology. Technology maturation is built into the project as successful research will include customized process-component down-selection enabling AM methodologies to be incorporated directly into the existing supply chain. The specific activities of the proposed effort are: 1. Topology optimization of down-selected steam turbine parts that are amenable to additive and hybrid manufacturing for cost/performance improvement. 2. Process-structure-property relationships for five AM processes for steam turbine materials of interest to compare with conventional materials. 3. Perform part/assembly build process using advanced additive/hybrid machine tools followed by quality inspection of the built components for insight into qualification for production scale-up. Steam turbine rig testing of printed components under targeted, well monitored and characterized environmental conditions of for performance comparison of baseline and redesigned components.

36 MATERIALS SCIENCE↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

A Convergence of Public-Private Benefits in Denver: Surveys and Analyses to Inform Urban Mobility-, Energy-, Infrastructure- and Behavior-Related Innovation: Preprint

Cities, public transit agencies, and new private ride hailing services seek to understand emerging traveler dynamics, the shifting demographics of urban travelers,and new energy-efficient mobility opportunities. This includes exploring how new infrastructure investments, public and private mobility services, and smart-phone mobility apps are reshaping behaviors, demands (e.g. mobility-on-demand services), travel experiences and energy-efficient urban travel preferences. Currently, cities and metropolitan regions are providing and experimenting with many new mobility options, technologies, and personalized information services at the intersection of urban mobility, energy, and infrastructure systems (e.g., new commuter rail). To date, technology alone has not been able to crack the nut of 'creating faster trip times, less congestion, safer streets, and cleaner air for its citizens through fewer cars on the road'. This paper focuses on this gap by offering new concepts and potential for integrated approaches. Accommodating more vehicles miles traveled in cities, without increases in person miles traveled (PMT), could be costly, generating: 1) tremendous demands for new infrastructure, land, road space, materials, and energy; 2) higher traffic fatality risks; and 3) worsening air quality. Therefore, this study focuses on reducing single occupancy vehicle use by enhancing integrated mobility, helping transit and ridehailing increase occupancy in ways that also reduce energy use, and improve quality of life for urban travelers and communities. This study focuses on a survey of urban travelers in Denver, as a representative case study for metropolitan regions experiencing rapid growth, ageing populations, increased urban sprawl, traffic-related delays, and inefficient energy use per PMT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The role of ternary alloying elements in eutectoid transformation of U-10Mo alloy part II. In and Ex-situ Neutron diffraction-based assessment of eutectoid phase transformation kinetics in U-9.8Mo-0.2X alloy (X = Cr, Ni or Co)

HExploring the effects of minor ternary alloying additions, typically impurity elements, on the phase stability of U-10Mo is important for preventing undesirable phase decomposition during processing or during service. This work examines the influence small ternary additions of Cr, Ni, and Co. Both in-situ and ex-situ neutron diffraction measurements made during and after high temperature (450 – 525°C) exposures were used to better define the influence of these elements on the time-temperature-transformation (TTT) behavior of U-10Mo, providing information which is complementary to electron microscopy investigations of the same alloy systems performed in the first part of this work. Minor additions of Ni and Co decrease the ?-phase stability at all temperatures investigated. Signatures of U6X (X = Ni or Co) compounds were shown to be present in amounts of up to 6 wt% in the heat treated alloys, suggesting that the initial precipitation of this phase may catalyze further ?-phase decomposition. On the other hand, the Cr containing alloys were observed to have nearly the same, and in some cases slower, phase transformation kinetics when compared to the binary U-10Mo control samples. The results of the study have enabled preliminary estimates of the TTT curves for the ternary alloys.

phase transformation, kinetics, discontinuous prec↗

Redesign of the Timeline Generator at Fermilab using a web-based Flutter application, GraphQL API and an IOC

The control system at Fermilab is undergoing an evolution with a shift towards web-based applications with connections to the EPICS infrastructure. The Timeline Generator (TLG) is an application that serves to coordinate events across the lab using different timing links. These links include the Tevatron clock (TCLK), a 10 MHz serial link with events encoded at 20Hz and Machine Data (MDAT), a communication link with states encoded at 720Hz. This paper covers the redesign of the major components of the TLG. This includes a web-based Flutter application for building timelines. A placement service is in use that has a GraphQL interface and uses a timeline input to compute a schedule of events and states. The Flutter application sends this computed schedule to the TLG IOC via a GraphQL interface to the Data Pool Manager (DPM). The TLG IOC runs on an Arria FPGA, the Accelerator Clock Generator (ACLK-GEN), which is responsible for writing the events and states on to the different timing links.

Carmichael, Linden [Fermilab]↗

Effect of temperature curing on properties and hydration of wollastonite blended magnesium potassium phosphate cements

K-struvite, the main hydrate of magnesium potassium phosphate (MKP) cements, dehydrates at ~50 °C, thus elevated temperatures at service conditions could affect cement properties and durability. In this study, properties and hydration of MKP cement without and with wollastonite were investigated at 20 and 50 °C. In hydrated pure MKP cement K-struvite decomposes progressively over time to MgKPO{sub 4}·H{sub 2}O at 50 °C, which leads to a strong reduction of solid volume and severe strength loss. The presence of wollastonite significantly slows down the decomposition rate of K-struvite, which is still observed after 393 days at 50 °C. K-struvite together with amorphous hydroxyapatite, M-(C)-S-H and CaK{sub 3}H(PO{sub 4}){sub 2} from the wollastonite reaction result in a cement with good short and long-term strength at both 20 and 50 °C.

36 MATERIALS SCIENCE↗

Collaborative Distribution System Restoration Planning and Real-Time Dispatch Considering Behind-the-Meter DERs

Modern distribution systems are becoming more resilient against power outages thanks to the flexible generation capacity provided by the increasing integration of distributed energy resources (DERs). Compared to utility-scale DERs, which can be directly controlled by system operators, small-scale, behind-the-meter DERs are much more difficult to coordinate despite being the vast majority. Two major obstacles to the implementation of DERs for service restoration are the coordination of behind-the-meter DERs and the management of uncertainty. In this paper, a novel distribution system restoration strategy is proposed to overcome these two obstacles. The flexibility of be-hind-the-meter DERs is quantified and integrated into the restoration planning models within a hierarchical structure. The model predictive control technique is employed to enable adaptive restoration planning solution adjustments to accommodate fault scenarios and forecast errors. Besides, real-time power dispatch models are proposed to maintain power balance using available DER capability. Comprehensive integration of adaptive restoration planning schemes and real-time dispatch results are achieved through a collaborative restoration framework. Finally, the effectiveness of the proposed restoration strategy is verified through a modified IEEE 123-bus system and a real-world utility system.

24 POWER TRANSMISSION AND DISTRIBUTION↗