Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A Meso-Climatology Study of the High-Resolution Tower Network Over the Florida Spaceport

Forecasters at the US Air Force 45th Weather Squadron (45 WS) use wind and temperature data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria and to issue and verify temperature and wind advisories, watches, and warnings for ground operations. The Spaceflight Meteorology Group at the Johnson Space Center in Houston, TX also uses these data when issuing forecasts for shuttle landings at the KSC Shuttle Landing Facility. Systematic biases in these parameters at any of the towers could adversely affect an analysis, forecast, or verification for all of these operations. In addition, substantial geographical variations in temperature and wind speed can occur under specific wind directions. Therefore, the Applied Meteorology Unit (AMU), operated by ENSCO Inc., was tasked to develop a monthly and hourly climatology of temperatures and winds from the tower network, and identify the geographical variation, tower biases, and the magnitude of those biases. This paper presents a sub-set of results from a nine-year climatology of the KSC/CCAFS tower network, highlighting the geographical variations based on location, month, times of day, and specific wind direction regime. Section 2 provides a description of the tower mesonetwork and instrumentation characteristics. Section 3 presents the methodology used to construct the tower climatology including QC methods and data processing. The results of the tower climatology are presented in Section 4 and Section 5 summarizes the paper.

Case, Jonathan L.↗

Planck 2015 results: III. LFI systematic uncertainties

In this paper, we present the current accounting of systematic effect uncertainties for the Low Frequency Instrument (LFI) that are relevant to the 2015 release of the Planck cosmological results, showing the robustness and consistency of our data set, especially for polarization analysis. We use two complementary approaches: (i) simulations based on measured data and physical models of the known systematic effects; and (ii) analysis of difference maps containing the same sky signal (“null-maps”). The LFI temperature data are limited by instrumental noise. At large angular scales the systematic effects are below the cosmic microwave background (CMB) temperature power spectrum by several orders of magnitude. In polarization the systematic uncertainties are dominated by calibration uncertainties and compete with the CMB E-modes in the multipole range 10–20. Based on our model of all known systematic effects, we show that these effects introduce a slight bias of around 0.2σ on the reionization optical depth derived from the 70GHz EE spectrum using the 30 and 353GHz channels as foreground templates. At 30GHz the systematic effects are smaller than the Galactic foreground at all scales in temperature and polarization, which allows us to consider this channel as a reliable template of synchrotron emission. We assess the residual uncertainties due to LFI effects on CMB maps and power spectra after component separation and show that these effects are smaller than the CMB amplitude at all scales. We also assess the impact on non-Gaussianity studies and find it to be negligible. Finally, some residuals still appear in null maps from particular sky survey pairs, particularly at 30 GHz, suggesting possible straylight contamination due to an imperfect knowledge of the beam far sidelobes.

79 ASTRONOMY AND ASTROPHYSICS↗

Directional radiometric measurements of row-crop temperatures

The variability of directional sensor response for a cotton row crop in Phoenix, Arizona was measured for various solar zenith angles. The geometric structure of the canopy was described with regard to height, width, spacing, and shape of rows. In addition, radiometric temperature data were collected on four scene components: sunlit and shaded vegetation and sunlit and shaded soil. These data were used to test the predictions and assumptions of a modified version of the row crop model of Jackson et al. (1979), which predicts the thermal infrared response of a sensor as a function of sensor view angle, component temperature, and geometrical structure of the canopy. The field data showed sensor response differentials as great as 16.2 C when going from a zenith view angle of 0 deg to one of 80 deg normal to the row direction. The rms deviation between the predicted and measured sensor response for all measurement periods and view angles was 0.96 C.

Kimes, D. S.↗

Modelling of ionospheric temperature profiles

Ionosphere electron temperature data gathered by the AE-C, AEROS, Isis-1 and -2 spacecraft are employed to define linear models for the average conditions. Account is taken of evidence for seasonal, altitudinal, solar activity and density-temperature effects. Notably, use is made of the high negative correlations between the electron temperature and density, thereby allowing either to be calculated if data are available on the density.

Bilitza, D.↗

Evaluation, construction and endurance testing of compression sealed pyrolytic boron nitride slot insulation

A high-temperature statorette, consisting of an iron-27 percent cobalt magnetic lamination stack and nickel-clad silver conductors, was tested with pyrolytic boron nitride slot insulation. Temperatures were measured in each test to determine characteristics of slot linear heat conductance from statorette conductors. Testing was carried out to temperatures of approximately 1500 F in a vacuum environment of 10-8 torr. Three assemblies were built and tested, each having a different room temperature slot clearance. The final statorette assembly was subjected to a 100-hour vacuum aging test at 1400 F followed by 25 thermal cycles. Temperature data from the three assemblies showed that decreasing slot clearance and increasing compression loading did enhance heat transfer. The temperature difference between slot and lamination at 1400 F increased 4 F during the thermal aging and an additional 10 F during the 25 thermal cycles.

Grant, W. L.↗

Millimeter-Wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms

This document describes the final report of the Millimeter-wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms. Volumes of radiometric data have been collected using airborne MIR measurements during a series of field experiments since May 1992. Calibrated brightness temperature data in MIR channels are now available for studies of various hydrological parameters of the atmosphere and Earth's surface. Water vapor retrieval algorithms using multichannel MIR data input are developed for the profiling of atmospheric humidity. The retrieval algorithms are also extended to do three-dimensional mapping of moisture field using continuous observation provided by airborne sensor MIR or spaceborne sensor SSM/T-2. Validation studies for water vapor retrieval are carried out through the intercomparison of collocated and concurrent measurements using different instruments including lidars and radiosondes. The developed MIR water vapor retrieval algorithm is capable of humidity profiling under meteorological conditions ranging from clear column to moderately cloudy sky. Simulative water vapor retrieval studies using extended microwave channels near 183 and 557 GHz strong absorption lines indicate feasibility of humidity profiling to layers in the upper troposphere and improve the overall vertical resolution through the atmosphere.

Chang, L. Aron↗

Room Temperature Characterization of a Magnetic Bearing for Turbomachinery

Open loop, experimental force and power measurements of a three-axis, radial, heteropolar magnetic bearing at room temperature for rotor speeds up to 20,000 RPM are presented in this paper. The bearing, NASA Glenn Research Center's and Texas A&M's third generation high temperature magnetic bearing, was designed to operate in a 1000 F (540 C) environment and was primarily optimized for maximum load capacity. The experimentally measured force produced by one C-core of this bearing was 630 lb. (2.8 kN) at 16 A, while a load of 650 lbs (2.89 kN) was predicted at 16 A using 1D circuit analysis. The maximum predicted radial load for one of the three axes is 1,440 lbs (6.41 kN) at room temperature. The maximum measured load of an axis was 1050 lbs. (4.73 kN). Results of test under rotating conditions showed that rotor speed has a negligible effect on the bearing's load capacity. A single C-core required approximately 70 W of power to generate 300 lb (1.34 kN) of magnetic force. The room temperature data presented was measured after three thermal cycles up to 1000 F (540 C), totaling six hours at elevated temperatures.

Montague, Gerald↗

Inverse Determination of Aeroheating and Charring Ablator Response

The Mars Science Laboratory (MSL) was protected during its Mars atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA). PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). These measurements have been widely used in the literature as a validation benchmark for state-of-the-art ablation codes. The objective of this work is to perform an inverse estimate of the MSL heatshield material properties and aerothermal environment during Mars entry from the MISP flight data.

Aeroheating↗

Towards the Prediction of the Mars 2020 Heatshield Material Response

Introduction: NASA’s next mission to Mars, the Mars 2020, will use the same heatshield of the Mars Science Laboratory (MSL) for thermal protection during entry, descent and landing. The heatshield is a tiled system made of Phenolic Impregnated Carbon Ablators (PICA) blocks [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to compare the thermal response of the MSL heatshield to the MISP flight data. In preparation to Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against MEDLI flight data.

heatshield↗

Heatshield Entry Modeling Using a Design, Analysis, and Optimization Toolbox

The Mars Science Laboratory (MSL) was protected during its Mars atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA). PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase the capability of the Design, Analysis, and Optimization of Thermal Protection Materials (DAOTPM) software. DAO-TPM is a Python based framework that works as a link between mission design, aerothermal and radiative environment computation, Thermal Protection Systems (TPS) microstructure analysis, material response and optimization tools. The toolbox has a Graphical User Interface (GUI) that allows the user to build as well as run the various software and utilities used to design, analyze and optimize a heatshield during atmospheric entry.

Meurisse, Jeremie B. E.↗

Time spectral analysis of midlatitude disturbances in the Martian atmosphere

Time-spectral and cross-spectral analyses are used to investigate synoptic pressure variations in the Viking-2 pressure, wind, and temperature data for selected portions of the Mars fall, winter, and spring seasons. Estimates of the phase relationships between the highly coherent pressure, wind, and temperature oscillations are obtained, and found to be very similar to those expected for baroclinic waves and to those obtained from terrestrial surface data. Phase speeds and zonal wavenumbers are inferred by interpreting the pressure and meridional wind variations in terms of eastward-traveling quasi-geostrophic waves.

Barnes, J. R.↗

Quantifying changes in climate variability and extremes: Pitfalls and their overcoming

Hot temperature extremes have increased substantially in frequency and magnitude over past decades. A widely used approach to quantify this phenomenon is standardizing temperature data relative to the local mean and variability of a reference period. Here we demonstrate that this conventional procedure leads to exaggerated estimates of increasing temperature variability and extremes. For example, the occurrence of “two-sigma extremes” would be overestimated by 48.2% compared to a given reference period of 30 years with time-invariant simulated Gaussian data. This corresponds to an increase from a 2.0% to 2.9% probability of such events. We derive an analytical correction revealing that these artifacts prevail in recent studies. Our analyses lead to a revision of earlier reports: For instance, we show that there is no evidence for a recent increase in normalized temperature variability. In conclusion, we provide an analytical pathway to describe changes in variability and extremes in climate observations and model simulations.

54 ENVIRONMENTAL SCIENCES↗

X-band atmospheric noise temperature statistics at Goldstone DSS 13, 1975 - 1976

X-band noise temperature data were taken at Goldstone DSS 13 for the period August 1975 through January 1977. A description of the experiment is given along with probability density functions for zenith noise temperature increase during all year quarters and day quarters. Elevation angle modeling of the data is described along with a discussion of the problems associated with relating wide beamwidth statistics to narrow beamwidth antennas.

Slobin, S.↗

Fault detection in PV systems

A practical fault detection approach for PV systems intended for online implementation is developed. The fault detection model here is built using artificial neural network. initially the photovoltaic system is simulated using MATLAB software and output power is collected for various combinations of irradiance and temperature. Data is first collected for normal operating condition and then four types of faults are simulated and data are collected for faulty conditions. Four faults are considered here and they are: Line to Line faults with a small voltage difference, Line to line faults with a large voltage difference, degradation fault and open-circuit fault. This data is then used to train the neural network and to develop the fault detection model. The fault detection model takes irradiance, temperature and power as the input and accurately gives the type of fault in the PV system as the output. This system is a generalized one as any PV module datasheet can be used to simulate the Photovoltaic system and also this fault detection system can be implemented online with the use of data acquisition system.

14 SOLAR ENERGY↗

Finite temperature properties of uranium mononitride

Uranium mononitride (UN) is a promising nuclear fuel that combines the advantageous properties of readily used UO 2 and uranium alloys, such as high melting temperature and high uranium density, and thermal conductivity, respectively. A better understanding of UN behavior at operating temperatures can be obtained from finite temperature data, such as elastic properties. To get this information, ab initio molecular dynamics (AIMD) simulations were performed at five different temperatures using constant volume (NVT) and constant pressure (NPT) ensembles. Initially, the performance of PBE functional in reproducing experimental crystallographic properties and magnetic ordering is assessed. The finite temperature phonon dispersions are calculated using NVT simulation results, which show a softening of the phonon modes with increasing temperature. The NPT results are used to obtain the thermal expansion of UN and finite temperature electronic properties. The calculated thermal expansion is compared with our measurements using neutron diffraction. Additionally, the temperature dependent elastic properties of UN are evaluated using the strain-stress method in AIMD simulations, indicating that UN becomes softer and more compressible with increasing temperature. Also, the calculated Young’s modulus slope is in very good agreement with the experiment. The finite temperature heat capacity and electronic thermal conductivity are calculated from AIMD simulations, which are in better agreement with the experiment than the heat capacity and thermal conductivity calculated using the structures relaxed at 0K. Finally, the thermal diffusivity from AIMD has opposite temperature dependence compared to experimental results, which we argued comes from the underestimated electronic thermal conductivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of a Heat Balance Experiment in the TREAT Reactor with SPARTA and OpenMC

This article presents the interpretation of a heat balance experiment in TREAT using the SPARTA methodology and an OpenMC model. The study examines the effects of control rods and temperature variations on the effective multiplication factor ($k_{\rm eff}$) and correction factors. Results indicate that both core temperature and rod positions have a linear effect on $k_{\rm eff}$ and correction factors in the upper-west channel. A critical hypothesis of SPARTA was validated: reactivities and correction factors can be obtained by linearly combining individual effects. The previously considered negligible effect of temperature on correction factors was found to be significant, necessitating updates to the SPARTA methodology. By fitting an exponential curve to mean temperature data, SPARTA's accuracy and convergence have been improved. Comparisons between SPARTA and OpenMC showed consistent reactivity removal due to temperature increase. While SPARTA effectively interprets complex transients, simpler methods may suffice when correction factors have minimal influence on reactivity calculations.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Speed of sound in methane under conditions of planetary interiors

We present direct observations of acoustic waves in warm dense matter. We analyze wave-number- and energy-resolved x-ray spectra taken from warm dense methane created by laser heating a cryogenic liquid jet. X-ray diffraction and inelastic free-electron scattering yield sample conditions of 0.3 ± 0.1 eV and 0.8 ± 0.1 g/ cm − 3 , corresponding to a pressure of ∼ 13 GPa. Inelastic x-ray scattering was used to observe the collective oscillations of the ions. With a highly improved energy resolution of ∼ 50 meV, we could clearly distinguish the Brillouin peaks from the quasielastic Rayleigh feature. Data at different wave numbers were utilized to derive a sound speed of 5.9 ± 0.5 km/s, marking a high-temperature data point for methane and demonstrating consistency with Birch's law in this parameter regime. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ORNL Package Testing Program Software Quality Assurance Plan

The Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP) uses commercial off-the-shelf (COTS) software in performing data collection of thermal test results for package designs that contain radioactive materials. Specifically, this software is used to collect temperature data from the furnace, packages, and ambient air to prepare and execute the thermal test specified in 10 CFR 71.73, “Thermal Test.” This software quality assurance (SQA) plan sets forth the guidelines, standards, and procedures that shall be used to provide SQA for PTP software applications. This is a living document that will be maintained for the lifecycle of the PTP program. The SQA plan follows the requirements set forth in ORNL Standards Based Management System (SBMS): Information Technology; Subject Area: Software Quality Assurance. When applicable to the requirements as described in ORNL SBMS, Software Quality Assurance, the software shall be listed in the ORNL Software Registration System (SRS). Exemptions to this SBMS are COTS and firmware that are not modified; spreadsheet applications and personal productivity tools that do not have a utility or safety application, research applications, legacy software, system software, vendor-supplied software used to interface with the vendor’s services, software used within the organization to facilitate processing or management of information, and software developed for applications not specific to the US Department of Energy (DOE).

97 MATHEMATICS AND COMPUTING↗