Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Temperature Sensing to Above 1500 °C Using Y 2 SiO 5 :Er Phosphor Thermometry

A transition from metallic to ceramic turbine components that can operate at higher turbine engine temperatures will push component surface temperatures from below 1200 °C into a 1300 to 1500 °C temperature range that is much more challenging for phosphor thermometry measurements. To address this challenge, Y 2 SiO 5 :Er was selected for its high temperature sensing performance by both luminescence lifetime and luminescence intensity ratio (LIR) methods as well as its thermochemical compatibility with the current generation of rare earth silicate environmental barrier coatings (EBCs) that are required to protect SiC/SiC ceramic composite components. Lifetime measurements that monitor the Er3+ 4S3/2→4I15/2 emission decay at 542 nm exhibited a slow decrease in decay time with temperature up to 1300° C, above which the decay decreased steeply to provide good temperature sensitivity in the 1300 to 1500 °C range (Fig. 1). LIR images were obtained where each pixel represented the ratio I488/I561 (I488 and I561 are the detected 488 nm 4F7/2→4I15/2 and the 561 nm 4S3/2→4I15/2 emission band intensities, respectively). Good temperature sensitivity (Fig. 2) and signal-to-background ratios were observed to above 1500 °C. Contrary to conventional guidance on selecting phosphors for high temperature sensing, the detected emission band intensities and decay times exhibited remarkably slow decreases with temperature up into the 1300 to 1500 °C range despite high phonon energies (>900 cm-1) that allow the energy gap between the 4S3/2 emitting reservoir level and the 4F9/2 level below it to be bridged by as few as three phonons. The benefits of utilizing a thermographic phosphor at very high temperatures that exhibits strong nonradiative multiphonon relaxation even at room temperature is explained by a competition between spontaneous and stimulated multiphonon emission, and the more temperature-sensitive decay time above 1300 °C is explained by a transition from high to low effective phonon energies.

temperature measurement↗

Role of Chemical Disorder in High Temperature Dislocation Glide in Refractory Multi-principal Element Alloys

Refractory multi-principal element alloys (RMPEAs) combine a chemically disordered lattice with a structurally ordered, single‐phase body‐centered cubic (bcc) crystal structure. Chemical fluctuations in these alloys give rise to significant energy barriers that impede dislocation motion. In this study, we use phase field dislocation dynamics to examine how spatial temperature fluctuations compete with randomness in energy barriers to affect the motion of long screw dislocations in three equi-atomic MoNbTa‐based RMPEAs: MoNbTa, MoNbTaW, and MoNbTaVW. Over a wide range of homologous temperatures (T h ≈ 0–0.6), we determined a screw dislocation ‘flow stress’ as the minimum applied stress to sustain continuous motion over a long excursion distance within a fixed timeframe. All three RMPEAs exhibit temperature dependent flow stress with three characteristic glide regimes: at low homologous temperatures, flow stress drops sharply, and screw glide remains planar and rectilinear; at intermediate homologous temperatures, the flow stress levels off as glide becomes planar but wavy; and at high homologous temperatures, flow stress plateaus as screws exhibit nonplanar, three‐dimensional motion. Glide kinetics and transition temperatures are controlled by the chemically induced fluctuations in the energy landscape. The rectilinear to wavy transition temperature is controlled by statistically weakest local barriers in the glide plane, whereas the wavy to 3D transition temperature is governed by statistically strongest local barriers. At low and intermediate homologous temperatures, the relative spread in energy barriers governs glide behavior by controlling the local kinetics of kink pair formation and kink pinning. At high homologous temperatures, the average barrier height governs the glide behavior by controlling the number of out-of-plane excursions during 3D glide. These findings reveal how random chemical fluctuations determine screw‐driven plasticity in RMPEAs, providing critical insight for the design of high temperature structural alloys.

Defects↗

Influence of ozone addition on the low-temperature oxidation of dimethyl ether in a jet-stirred reactor

The influence of ozone addition on the low-temperature oxidation of dimethyl ether (DME) was investigated experimentally in an atmospheric-pressure jet-stirred reactor, over the temperature range of 400–800 K. Detailed speciation information was obtained by employing synchrotron vacuum ultraviolet photoionization mass spectrometry. Experimental results revealed that the ozone addition had a positive influence on the production of the highly reactive intermediates. Moreover, the low-temperature reactivity of DME was significantly enhanced, which resulted in the broadening of the temperature window of fuel consumption and intermediates formation at lower temperatures. Therefore, novel experimental data of the low temperature regime (400–500 K) could be obtained. The data set of this special temperature regime yielded insights into the DME low-temperature kinetics, which were further supported with modeling analysis based on two existing DME models (Metcalfe et al., 2013; Wang et al., 2015) combined with an ozone sub-mechanism (Zhao et al., 2016). The analysis showed that temperature-sensitive reactions such as the second oxygen channel could be nearly “frozen” at this low temperature (T < 440 K). Furthermore, the production of some intermediates was found to be strongly governed by reaction pairs, such as CH 3 OCH 2 + O 2 = CH 3 OCH 2 O 2 and CH 3 OCH 2 + O 2 = 2 CH 2 O + OH for the CH 2 O formation. This finding could be useful for examining branching ratios in both models, and the analysis suggested the further modification of the branching ratios for the oxygen addition to CH 3 OCH 2 O 2 pathways and the CH 3 OCH 2 O 2 self-reactions were required. Finally, the influences of the O 3 addition in the sensitive reactions of the fuel initial low-temperature oxidation were investigated in this work. It was interesting to note that O 3 addition could change the dominating reactions in the initial low-temperature oxidation, by the addition of some O 3 -related pathways with relatively high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Applicability of Allen–Heine–Cardona Theory on MO x Metal Oxides and ABO 3 Perovskites: Toward High-Temperature Optoelectronic Applications [plus supplemental information]

We report characterizing the temperature-dependent electronic structures of optoelectronic materials is vital for their application in high-temperature processes. Allen–Heine–Cardona (AHC) theory is an established theory to determine the impact of electron–phonon coupling on the temperature renormalization of the electronic structure. A question of fundamental interest is how applicable this approach can be in a broad range of materials. Herein, we establish the consensus on the temperature dependence of band gaps between AHC predictions and experimental measurements, in a versatile set of nine MO x metal oxides and six ABO 3 perovskites that are utilized as gas sensors. Both calculations and measurements point to the appreciable band gap downshifts within the temperature range relevant to typical high-temperature applications in all examined materials. The correlation between the band gaps and temperatures was quantified at zero- and finite-temperature limits using the analytical parameters of the O’Donnell model. We found fairly comparative agreements between AHC- and experiment-derived parameters, especially for the parameters (S and $\langle\hbar$ω$\rangle$) defining the temperature dependence behavior of band gaps at the finite-temperature regime. Our findings provide important implications for the first-principles modeling of the electronic structures and their temperature dependency, which should be the focus toward high-temperature optoelectronic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inferring thermal ion temperature and residual kinetic energy from nuclear measurements in inertial confinement fusion implosions

In inertial con finement fusion implosion experiments, the presence of residual anisotropic fluid motion within the stagnating hot spot leads to signifi cant variations in ion-temperature measurements using neutron time- of-flight detectors along different lines of sight. The minimum ion-temperature measurement is typically used as representative of the thermal temperature. In the presence of isotropic flows, however, even the minimum DT neutron-inferred ion temperature can be well above the plasma thermal temperature. Using both DD and DT neutron-inferred ion-temperature measurements, we show that it is possible to determine the contribution of isotropic flows and infer the DT burn-averaged thermal ion temperature. The contribution of large isotropic flows on driving the ratio of DD to DT neutron-inferred ion temperatures well below unity and approaching the lower bound of 0.8 is demonstrated in multimode simulations. The minimum DD neutron- inferred ion temperature is determined from the velocity variance analysis, accounting for the presence of isotropic flows. Being close to the DT burn-averaged thermal ion temperature, the inferred DD minimum ion temperatures demonstrate a strong correlation with the experimental yields in the OMEGA implosion database. An analytical expression is also derived to explain the effect of mode ℓ = 1 ion-temperature measurement asymmetry on yield degradations caused by the anisotropic flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature distribution in a laser-heated diamond anvil cell as described by finite element analysis

Finite element analysis (FEA) is a powerful tool for numerically solving partial differential equations over complex geometries and is thus useful for analyzing heat transport in laser-heated diamond anvil cell (LHDAC) experiments. Our models expand on previously published simulations by calculating the volume-averaged temperatures of both the sample and insulation/pressure media under steady-state heating to determine the thermal pressure of the hot sample. Our goal is to produce an accurate relationship between the measured surface temperature of the absorbing sample and the temperature of the transparent insulating media, which is used to determine thermal pressure but susceptible to steep temperature gradients. We find that in doing so, our FEA models of temperature within the pressure/insulation media can differ from simplified estimates of temperature gradients by more than a factor of 2. We also explore temperature-dependent and temperature-independent thermal conductivity models and find that the volume-averaged temperatures differ by up to a factor of 1.3, forcing the predicted thermal pressures determined to also differ by up to a factor of 1.5 at a temperature of 2000 K at 50 GPa for neon. Higher temperatures exacerbate this difference. We also find that unintentional asymmetric sample insertion and sample heating, which are common in LHDAC experiments, do not have a first-order effect on volume-averaged temperatures. The FEA models, available in both Python and FlexPDE, are versatile across different sample geometries, materials, and heat source laser shapes.

Farah, Frederick↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gradient Amine Sorbents for Low Vacuum Swing CO 2 Capture at Ambient Temperature

The growing concerns over CO 2 emissions have led to the development of various methods for CO 2 capture. CO 2 capture by amine-based sorbents has been achieved by temperature (thermal) swing adsorption (TSA) process, pressure swing adsorption (PSA) process, and temperature pressure or vacuuming swing adsorption (TPSA or TVSA) process for CO 2 capture. Amine sorbents for energy-efficient TSA, PSA, VSA, TPSA or TVSA CO 2 capture should possess a capability which allow adsorbed CO 2 to desorb and amine sorbent to be regenerated at low temperatures or low vacuums. Development of such amine sorbents would significantly decrease energy consumption and sorbent degradation during the regeneration step. The objective of this project is to develop a low vacuum swing adsorption (VSA) process for the capture of CO 2 from air. The focus is on the development of amine sorbent which allows CO 2 to adsorb in the form of weakly adsorbed CO 2 . The weakly adsorbed CO 2 species can be collected from the sorbent by applying a low vacuum at ambient temperature. Specifically, no heating (i.e., thermal energy) is needed for regeneration of amine sorbents. This novel sorbent allows VSA to be operated at ambient temperature without a significant energy demand. This process eliminates the energy-intensive heating and cooling process in temperature swing adsorption (TSA) process. Ambient temperature operation could prolong the lifetime of sorbent and minimize the maintenance cost. Extensive sorbent studies with in-situ infrared spectroscopy have revealed the modifications of conventional amine sorbents with additives can increase the fraction of weakly adsorbed CO 2 . The amine sorbents with loaded CO 2 can be regenerated in part by the following approaches: (i) mild heating to temperatures below 70 °C, (ii) flowing purging gas over modified amine sorbents at temperatures below 40 °C, (iii) vacuuming at pressure below 0.2 atm and temperatures below 40 °C. The performance of these modified amine sorbents has been tested in a 60 grams VSA unit at ambient temperatures. The results show that weakly adsorbed CO 2 which can be desorbed from modified amine sorbents with purging gas at 100 cc/min can also be evacuated at a vacuum of 1 psia at room temperature. A preliminary techno- economic analysis indicates the major cost of the VSA process with modified amine sorbents stems from the operation of vacuum pumps. Thus, developing an excellent sealing with minimum leakage for the VSA unit is the most critical task for further the development of this VSA technology.

36 MATERIALS SCIENCE↗

High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines (Final Report)

This is the final report for project DE-FE0031924 titled “High-temperature seals for supercritical carbon-dioxide (sCO 2 ) turbines.” The report provides a summary of the entire project efforts from October 2020 through December 2024 including the high-temperature commercial dry gas seal (DGS) tests and thermal modeling of Task 2, as well as the high-temperature, large-diameter seal design and high-temperature tests of large-diameter seals in Task 3. A key outcome of Task 2 was the testing completion of specially instrumented commercial DGS in the GE-SwRI Apollo sCO 2 compressor (27,000 rpm). Test data from the DGS showed elevated temperatures upwards of 350 o F, which are close to the higher operating temperature limit of the DGS. The temperature measurements provide insight into the expected thermal loads on DGS operating in high-speed sCO 2 compressor and provided test data for validation of an in-house thermal model of the compressor/seal. Under Task 2.0, this report also presents the development of a steady-state conjugate heat-transfer model of the DGS operating in the sCO 2 compressor – a first of its kind model for modeling heat transfer of sCO 2 in an actual operating compressor. The findings of the thermal model show a reasonable match between temperature predictions of the model and the measured temperature data, also pointing out the validity of the approach and assumptions made in modeling the flows, heat transfer coefficients and windage modeling in the rig. Under Task 3.0, this report presents the preliminary design of a large-diameter hybrid face seal (14 inch and 26-inch diameter) for field testing in a land-based GE turbine. The preliminary seal design effort presented in this report under project DE-FE0031924 builds on the development and successful laboratory testing for such large diameter hybrid face seal under the prior DE-FE0024007 project. Key aspects of seal fluid analyses with CFD, mechanical design considerations and assembly considerations in a land-based turbine are presented. Finally, under Task 3.0, this report also presents the continued high-temperature testing of the 14-inch diameter hybrid face seal developed previously under the DE-FE0024007 program. Specifically, test data demonstrating successful non-contact seal operation and seal effective leakage of 0.001-inch with seal inlet temperatures above 700 o F are presented in this report. Successful hybrid seal operation in a laboratory environment for a large diameter (14-inch) seal at temperatures above 700 o F is a major technological milestone for this technology.

01 COAL, LIGNITE, AND PEAT↗

High temperature sensor/microphone development for active noise control

The industrial and scientific communities have shown genuine interest in electronic systems which can operate at high temperatures, among which are sensors to monitor noise, vibration, and acoustic emissions. Acoustic sensing can be accomplished by a wide variety of commercially available devices, including: simple piezoelectric sensors, accelerometers, strain gauges, proximity sensors, and fiber optics. Of the several sensing mechanisms investigated, piezoelectrics were found to be the most prevalent, because of their simplicity of design and application and, because of their high sensitivity over broad ranges of frequencies and temperature. Numerous piezoelectric materials are used in acoustic sensors today; but maximum use temperatures are imposed by their transition temperatures (T(sub c)) and by their resistivity. Lithium niobate, in single crystal form, has the highest operating temperature of any commercially available material, 650 C; but that is not high enough for future requirements. Only two piezoelectric materials show potential for use at 1000 C; AlN thin film reported to be piezoactive at 1150 C, and perovskite layer structure (PLS) materials, which possess among the highest T(sub c) (greater than 1500 C) reported for ferroelectrics. A ceramic PLS composition was chosen. The solid solution composition, 80% strontium niobate (SN) and 20% strontium tantalate (STa), with a T(sub c) approximately 1160 C, was hot forged, a process which concurrently sinters and renders the plate-like grains into a highly oriented configuration to enhance piezo properties. Poled samples of this composition showed coupling (k33) approximately 6 and piezoelectric strain constant (d33) approximately 3. Piezoactivity was seen at 1125 C, the highest temperature measurement reported for a ferroelectric ceramic. The high temperature piezoelectric responses of this, and similar PLS materials, opens the possibility of their use in electronic devices operating at temperatures up to 1000 C. Concurrent with the materials study was an effort to define issues involved in the development of a microphone capable of operation at temperatures up to 1000 C; important since microphones capable of operation above 260 C are not generally available. The distinguishing feature of a microphone is its diaphragm which receives sound from the atmosphere: whereas, most other acoustic sensors receive sound through the solid structure on which they are installed. In order to gain an understanding of the potential problems involved in designing and testing a high temperature microphone, a prototype was constructed using a commercially available lithium niobate piezoelectric element in a stainless steel structure. The prototype showed excellent frequency response at room temperature, and responded to acoustic stimulation at 670 C, above which temperature the voltage output rapidly diminished because of decreased resistivity in the element. Samples of the PLS material were also evaluated in a simulated microphone configuration, but their voltage output was found to be a few mV compared to the 10 output of the prototype.

Shrout, Thomas R.↗

Method development for compensating temperature effects in pressure sensitive paint measurements

Pressure sensitive luminescent paints (PSP) have recently emerged as a viable technique for aerodynamic pressure measurements. The technique uses a surface coating which contains probe molecules that luminesce when excited by light of an appropriate wavelength. The photoluminescence of these materials is known to be quenched by the presence of molecular oxygen. Since oxygen is a fixed mole fraction of the air, the coating's luminescence intensity varies inversely with air pressure. Digital imaging of the luminescence varying across a coated surface produces a pressure distribution map over that surface. One difficulty encountered with this technique is the temperature effect on the luminescence intensity. Present PSP formulations have significant sensitivity to temperature. At the moment, the most practical way of correcting for temperature effects is to calibrate the paint in place at the operating temperatures by using a few well-placed pressure taps. This study is looking at development of temperature indicating coatings that can be applied and measured concurrently with PSP, and use the temperature measurement to compute the correct pressure. Two methods for this dual paint formulation are proposed. One method will use a coating that consists of temperature sensitive phosphors in a polymer matrix. This is similar in construction to PSP, except that the probe molecules used are selected primarily for their temperature sensitivity. Both organic phosphors (e.g., europium thenoyltrifluoroacetonate, bioprobes) and inorganic phosphors (e.g., Mg4(F)GeO6:Mn, La2O2S:Eu, Radelin Type phosphors, Sylvania Type phosphors) will be evaluated for their temperature sensing potential. The next method will involve a novel coating composing of five membered heterocyclic conducting polymers which are known to show temperature dependent luminescence (e.g., poly(3-alkylthiopene), poly(3-alkylselenophene), poly(3-alkylfuran)). Both methods will involve applying a bottom layer of temperature sensitive coating followed by a top coating of PSP. An oxygen-impermeable polymer can be used as the temperature sensitive coating matrix, or it can be layered in between the coatings to prevent oxygen quenching of the bottom coating's luminescence. The probe molecules of the coatings will be excited by a broad band of light, with the different emissions detected and measured at their distinct wavelengths. Developmental research of these coatings is still in progress; however, preliminary results look very promising.

Demandante, Carlo Greg N.↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents a theory that explains low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Oscillations of the CC temperature with amplitudes on the order of tens of degrees Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There are presently no satisfactory explanations for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator heat load, sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. The proposed new theory describes why low frequency, high amplitude oscillations may occur when the LHP has a low evaporator power, a low heat sink temperature (below ambient temperature), and a large thermal mass attached to the evaporator. When this condition prevails, there are some complex interactions between the CC, condenser, thermal mass and ambient. The temperature oscillation is a result of the large movement of the vapor front inside the condenser, which is caused by a change in the net evaporator power modulated by the large thermal mass through its interaction with the sink and CC. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.

Ku, Jentung↗

Wide-Range Temperature Sensors with High-Level Pulse Train Output

Two types of temperature sensors have been developed for wide-range temperature applications. The two sensors measure temperature in the range of -190 to +200 C and utilize a thin-film platinum RTD (resistance temperature detector) as the temperature-sensing element. Other parts used in the fabrication of these sensors include NPO (negative-positive- zero) type ceramic capacitors for timing, thermally-stable film or wirewound resistors, and high-temperature circuit boards and solder. The first type of temperature sensor is a relaxation oscillator circuit using an SOI (silicon-on-insulator) operational amplifier as a comparator. The output is a pulse train with a period that is roughly proportional to the temperature being measured. The voltage level of the pulse train is high-level, for example 10 V. The high-level output makes the sensor less sensitive to noise or electromagnetic interference. The output can be read by a frequency or period meter and then converted into a temperature reading. The second type of temperature sensor is made up of various types of multivibrator circuits using an SOI type 555 timer and the passive components mentioned above. Three configurations have been developed that were based on the technique of charging and discharging a capacitor through a resistive element to create a train of pulses governed by the capacitor-resistor time constant. Both types of sensors, which operated successfully over the wide temperature range, have potential use in extreme temperature environments including jet engines and space exploration missions.

Hammoud, Ahmad↗

Projections of Temperature-Attributable Premature Deaths in 209 U.S. Cities Using a Cluster-Based Poisson Approach

Background: A warming climate will affect future temperature-attributable premature deaths. This analysis is the first to project these deaths at a near national scale for the United States using city and month-specific temperature-mortality relationships. Methods: We used Poisson regressions to model temperature-attributable premature mortality as a function of daily average temperature in 209 U.S. cities by month. We used climate data to group cities into clusters and applied an Empirical Bayes adjustment to improve model stability and calculate cluster-based month-specific temperature-mortality functions. Using data from two climate models, we calculated future daily average temperatures in each city under Representative Concentration Pathway 6.0. Holding population constant at 2010 levels, we combined the temperature data and cluster-based temperature-mortality functions to project city-specific temperature-attributable premature deaths for multiple future years which correspond to a single reporting year. Results within the reporting periods are then averaged to account for potential climate variability and reported as a change from a 1990 baseline in the future reporting years of 2030, 2050 and 2100. Results: We found temperature-mortality relationships that vary by location and time of year. In general, the largest mortality response during hotter months (April - September) was in July in cities with cooler average conditions. The largest mortality response during colder months (October-March) was at the beginning (October) and end (March) of the period. Using data from two global climate models, we projected a net increase in premature deaths, aggregated across all 209 cities, in all future periods compared to 1990. However, the magnitude and sign of the change varied by cluster and city. Conclusions: We found increasing future premature deaths across the 209 modeled U.S. cities using two climate model projections, based on constant temperature-mortality relationships from 1997 to 2006 without any future adaptation. However, results varied by location, with some locations showing net reductions in premature temperature-attributable deaths with climate change.

Schwartz, Joel D.↗

Temperature Structure in the Perseus Cluster Core Observed with Hitomi

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8-20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region _ 7′ in diameter. The SXS was operated with an energy resolution of _5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components

Aharonian, Felix↗

Temperature Fluctuations and Boundary Layer Turbulence as seen by Mars Exploration Rovers Miniature Thermal Emission Spectrometer

The Mini-TES spectrometer carried by Spirit and Opportunity is a unique instrument that enabled vertical temperature profiles to be retrieved at high frequency (every 2 s, or “ICK”). Observations obtained from this instrument provide information on boundary layer activity. As an extension of previous work, we have retrieved ICK-by-ICK vertical temperature profiles to characterize turbulent behavior at each rover site for up to two Mars Years. We have also retrieved ICK-by-ICK near-surface (1.1 m) atmospheric temperatures and surface temperatures from dedicated atmospheric observations as well as geologic observations that extend the coverage of near-surface observations. The extension and increased frequency of retrievals as well as the additional observations provide a more complete view of the vertical and temporal variation of temperature fluctuations within the PBL. Temperature fluctuations are assessed using detrended temperature time-series data. The results show fluctuations can be as large as 10 K at the surface and 8 K aloft with timescales on the order of minutes. We have calculated the peak-to-peak amplitudes of temperature fluctuations and the corresponding timescales over which they occur. Spirit and Opportunity temperature fluctuation amplitudes decrease in magnitude vertically, where higher atmospheric levels show smaller fluctuations in amplitudes than at the surface. The magnitude of temperature fluctuations changes with the difference in surface and air temperature. This difference varies little as a function of season at both rover sites. Fluctuations are observed to quickly decrease in the late afternoon reaching a minimum near 17:00 LTST followed by moderately increased activity near sunset caused by forced convection. There is no significant change in the observed convective activity as a function of dust optical depth during regional dust storms. The few large temperature fluctuations that are concurrent with dust events are likely the result of large-scale systems.

Mars, atmosphere↗