Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Development of a MOOSE thermal model of the MPC-32 canister and HI-STORM overpack

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. Safe management of spent nuclear fuel (SNF) is a key aspect of the back end of the nuclear fuel cycle, and SNF dry storage systems are becoming a popular, effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution for maintaining SNF (~60 years) prior to final disposal. This project aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack, using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. This study will investigate and demonstrate the thermal-hydraulics capabilities of the MOOSE framework, including natural circulation, heat transfer, porous flows, etc. The ultimate goal of the project is to verify whether MOOSE tools (including Pronghorn) can be used to study the thermal performance of the SNF dry cask storage system. This study provides reliable and inclusive solving strategy for dry cask problems. The detailed information about the solving scheme and the governing equations related to the physics of the system is provided in the report. The results for thermal-hydraulic analysis of the HI-STORM system is produced with using open source modules of the MOOSE framework. This results highlights the flexibility and modularity of the MOOSE which makes it a unique candidate for the frameworks and code packages. Therefore, integration of the MOOSE to UNF ST&DARDS will improve the thermal-hydraulic capability of the system while providing distinctive features to users.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multilaminate Energy Storage Films from Entropy‐Driven Self‐Assembled Supramolecular Nanocomposites

Abstract Composite materials comprising polymers and inorganic nanoparticles (NPs) are promising for energy storage applications, though challenges in controlling NP dispersion often result in performance bottlenecks. Realizing nanocomposites with controlled NP locations and distributions within polymer microdomains is highly desirable for improving energy storage capabilities but is a persistent challenge, impeding the in‐depth understanding of the structure–performance relationship. In this study, a facile entropy‐driven self‐assembly approach is employed to fabricate block copolymer‐based supramolecular nanocomposite films with highly ordered lamellar structures, which are then used in electrostatic film capacitors. The oriented interfacial barriers and well‐distributed inorganic NPs within the self‐assembled multilaminate nanocomposites effectively suppress leakage current and mitigate the risk of breakdown, showing superior dielectric strength compared to their disordered counterparts. Consequently, the lamellar nanocomposite films with optimized composition exhibit high energy efficiency (>90% at 650 MV m −1 ), along with remarkable energy density and power density. Moreover, finite element simulations and statistical modeling have provided theoretical insights into the impact of the lamellar structure on electrical conduction, electric field distribution, and electrical tree propagation. This work marks a significant advancement in the design of organic–inorganic hybrids for energy storage, establishing a well‐defined correlation between microstructure and performance.

Li, He↗

Compressed Gas Energy Storage Integrated with Combined Heat and Power Plant

A new energy storage technology, Comrpessed Gas Energy Storage (CGES), seeks to achieve low-cost, long-duration eenrgy storage by combining mature commercially-available technology (compressors, high-pressure gas storage, expander generators) and utilizing existing infrastructure for transportation and distribution of industrial gases. CGES utilizes existing compressors to transform electricity into potential energy (pressure), existing pipelines or underground storage to store said potential energy, and adds new expander generators at pressure reduction points in the networkm to recover part of the energy used in compression and transform it into electricity. By adapting itself to widely available existing infrastructure, CGES recovers energy that is otherwise wasted in the gas value chain, reduces the cost of new facilities, and avoids many of the development huddles typically associated with other long-duration energy storage technologies (e.g., Compressed Air Energy Storage, CAES). This paper discusses the performance and economics associated with CGES as a standalone project and in combination with a thermal power plant, based on a concept for integration of the technology over an existing lateral pipeline transporting natural gas to an 85 MW combined heat and power plant that feeds power to a grid with increasing share of renewable power generation.

03 NATURAL GAS↗

Viability of S3 Object Storage for the ASC Program at Sandia

Recent efforts at Sandia such as DataSEA are creating search engines that enable analysts to query the institution’s massive archive of simulation and experiment data. The benefit of this work is that analysts will be able to retrieve all historical information about a system component that the institution has amassed over the years and make better-informed decisions in current work. As DataSEA gains momentum, it faces multiple technical challenges relating to capacity storage. From a raw capacity perspective, data producers will rapidly overwhelm the system with massive amounts of data. From an accessibility perspective, analysts will expect to be able to retrieve any portion of the bulk data, from any system on the enterprise network. Sandia’s Institutional Computing is mitigating storage problems at the enterprise level by procuring new capacity storage systems that can be accessed from anywhere on the enterprise network. These systems use the simple storage service, or S3, API for data transfers. While S3 uses objects instead of files, users can access it from their desktops or Sandia’s high-performance computing (HPC) platforms. S3 is particularly well suited for bulk storage in DataSEA, as datasets can be decomposed into object that can be referenced and retrieved individually, as needed by an analyst. In this report we describe our experiences working with S3 storage and provide information about how developers can leverage Sandia’s current systems. We present performance results from two sets of experiments. First, we measure S3 throughput when exchanging data between four different HPC platforms and two different enterprise S3 storage systems on the Sandia Restricted Network (SRN). Second, we measure the performance of S3 when communicating with a custom-built Ceph storage system that was constructed from HPC components. Overall, while S3 storage is significantly slower than traditional HPC storage, it provides significant accessibility benefits that will be valuable for archiving and exploiting historical data. There are multiple opportunities that arise from this work, including enhancing DataSEA to leverage S3 for bulk storage and adding native S3 support to Sandia’s IOSS library.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

Historical Hydropower Operations and Economic Value

This report on historical hydropower operations and economic value focuses primarily on addressing HydroWIRES Objective 1.3: Advance valuation of conventional and pumped-storage hydropower assets. It is informed by previous work performed by Argonne and other national laboratories on the modeling and analysis of value of pumped storage and conventional hydropower. The results from this report will feed into the new projects that are planned under the HydroWIRES initiative and that will examine hydropower’s value in providing grid reliability and resilience, as well as in improving the modeling and representation of hydropower in power system models. Other relevant DOE efforts include various WPTO-funded projects, such as the Beyond Levelized Cost of Energy Project and Integrated Hydropower and Storage Systems, that are currently addressing similar challenges associated with defining grid service values that arise from hydropower machine capabilities.

13 HYDRO ENERGY↗

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Optimal Sizing and Dispatch of Solar Power with Storage

Designers of utility-scale solar plants with storage, seeking to maximize some aspect of plant performance, face multiple challenges. In many geographic locations, there is significant penetration of photovoltaic generation, which depresses energy prices during the hours of solar availability. An energy storage system affords the opportunity to dispatch during higher-priced time periods, but complicates plant design and dispatch decisions. Solar resource variability compounds these challenges, because determining optimal system sizes requires simultaneously considering how the plant will be operated under the imposed market and weather conditions. We develop an approach to analyze the economic performance of hybrid and single-technology solar power plants, which incorporates optimal dispatch, and considers the expected electricity market and weather conditions. We utilize the System Advisor Model software package to simulate the operation of multiple renewable generation and energy storage technologies, in conjunction with hourly-fidelity generation decisions determined by a revenue-maximizing, mixed-integer linear program. We show that, under our assumed market and weather conditions, the lifetime benefit-to-cost ratio can be improved by 6 to 19 percent, relative to a baseline design without optimizing, and that a concentrating solar power with thermal energy storage design produces significantly more energy per year, but is less profitable under our cost assumptions.

black-box optimization↗

Early Battery Performance Prediction for Mixed Use Charging Profiles Using Hierarchal Machine Learning

A key step limiting how fast batteries can be deployed is the time necessary to provide evaluation and validation of performance. Using data analysis approaches, such as machine learning, the validation process can be accelerated. However, questions on the validity of projecting models trained on limited data or simple cycling profiles, such as constant current cycling, to real-world scenarios with complex loads remains. Here, we present the ability to predict performance with less than 1.2% mean absolute percent error when trained on cells aged using complex electric vehicle discharge profiles, and either AC Level 2 charge or DC Fast charge profiles, using only the first 45 cycles, namely 5% of the total testing time. While error is low across the projections, this study also highlights that battery lifetime analysis using only cycling data may not extrapolate safely to certain real-world conditions due to the impact of calendar degradation.

25 ENERGY STORAGE↗

Modeling Impacts of Resilience Architectures for Extreme-Scale Storage Systems

The Scientific Modeling and Simulation of Storage project focused on improving our ability to store information reliably. The project, done jointly at the University of Wisconsin-Madison, Los Alamos National Laboratories, and Sandia National Laboratories, had the main goal of transforming the art of reliable storage system construction into a more precise science. Along those lines, the project developed numerous tools to expose problems in existing systems; these tools, when applied to the state of the art, uncovered numerous flaws in existing approaches, showing that they both are error prone and in some cases contain serious design flaws. The project also led to the creation of new approaches in reliable system construction. One such approach shows how a storage system can adapt its behavior on the fly to deliver higher performance when there are few underlying failures, but then act more conservatively when more failures are occurring to ensure the safe storage of user data. Another approach develops a storage system consistency model which both delivers high performance but high levels of reliability, a significant advance over previous approaches. Overall, the tools developed within the project advanced the science of reliable storage design, and the new approaches that resulted advanced the science of storage system construction.

97 MATHEMATICS AND COMPUTING↗

Idaho Falls Power Black Start Field Demonstration (Preliminary Outcomes Paper)

This April 2021 field demonstration builds upon a 2017 field demonstration in which it was determined IFP’s HPPs, on their own, can support islanded black start and operation up to 2.5 MW loading. Modeling and hardware-in-the-loop testing was used in the intervening period to design an energy storage solution, specifically using ultracapacitors, to reduce likelihood of generators tripping during the field demonstration. Overall, the 2021 field demonstration tested three different options for meeting IFP’s requirements: innovating the hydropower controls, synchronizing multiple HPPs on the system, and integrating an ultracapacitor energy storage system. This report documents the testing performed. Follow-on analysis will provide additional insights, for example, including a complete table of comparative results between the tests and scenarios. The analysis will also propose a refined design for an energy storage system to meet IFP’s grid islanded needs.

13 HYDRO ENERGY↗

Formal Definitions and Performance Comparison of Consistency Models for Parallel File Systems

The semantics of HPC storage systems are defined by the consistency models to which they abide. Storage consistency models have been less studied than their counterparts in memory systems, with the exception of the POSIX standard and its strict consistency model. The use of POSIX consistency imposes a performance penalty that becomes more significant as the scale of parallel file systems increases and the access time to storage devices, such as node-local solid storage devices, decreases. While some efforts have been made to adopt relaxed storage consistency models, these models are often defined informally and ambiguously as by-products of a particular implementation. Here in this work, we establish a connection between memory consistency models and storage consistency models and revisit the key design choices of storage consistency models from a high-level perspective. Further, we propose a formal and unified framework for defining storage consistency models and a layered implementation that can be used to easily evaluate their relative performance for different I/O workloads. Finally, we conduct a comprehensive performance comparison of two relaxed consistency models on a range of commonly seen parallel I/O workloads, such as checkpoint/restart of scientific applications and random reads of deep learning applications. We demonstrate that for certain I/O scenarios, a weaker consistency model can significantly improve the I/O performance. For instance, in small random reads that are typically found in deep learning applications, session consistency achieved a 5x improvement in I/O bandwidth compared to commit consistency, even at small scales.

97 MATHEMATICS AND COMPUTING↗

Progress on Advancing the Robotic Air-slot Volumetric Inspection System (RAVIS) for Hanford Under-tank Inspection - 20519

The 27 in-service double-shell tank (DST) systems at Hanford provide interim storage for nearly 56 million gallons of nuclear and hazardous chemical legacy waste. The safe and reliable storage of the waste is critical to the site's extended cleanup mission. While in service, the leak integrity of the DSTs must be demonstrated to satisfy the Washington Administrative Code, inform decisions on tank management, and gauge fitness for continued service beyond originally intended design lives. The carbon steel plates and welds that comprise DST primary tank sidewalls and lower knuckles are routinely 'sampled' for volumetric non-destructive testing using ultrasonic inspection technology to determine whether corrosion pitting, cracking, or general corrosion are occurring that could compromise tank leak integrity. However, the carbon steel plates and welds that comprise the bottoms of primary tanks have not been thoroughly inspected since the DSTs were constructed (i.e., since 1968-1986) due to limited physical access to the exterior tank bottoms. The Robotic Air-slot Volumetric Inspection System, or 'RAVIS,' is being engineered to overcome the challenge of tank bottom in-service inspection. The system will be deployed under primary tanks within the small cooling channels/air-slots in the refractory pads upon which the tanks rest and will use ultrasonic guided wave inspection technology to volumetrically inspect physically inaccessible regions that make up ∼90% of a tank bottom, as well as regions that are physically accessible from the air-slots but comprise only ∼10% of a tank bottom. This paper describes the air-slot sensor and robotic deployment system and focuses on the testing approach and methods that are being applied to support (1) design feedback and performance acceptance (requirement verification) and (2) performance repeatability/reliability assessments (qualification) to ensure the RAVIS is prepared for successful inservice inspections of primary tank bottoms. Test progress made against the test plan, the results of 2019 testing, and the future outlook are included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Functional Surface Coating to Enhance the Stability of LiNi 0.6 Mn 0.2 Co 0.2 O 2

Parasitic reactions are responsible for continuous performance loss during the normal operation and storage of lithium-ion batteries, particularly for those using nickel-rich cathode materials. Among many contributors, residual Li 2 CO 3 on the surface of nickel-rich cathodes plays a detrimental role in promoting parasitic reactions, and hence accelerates the performance loss of those cathode materials. In this work, a wet impregnation process was utilized to convert the detrimental Li 2 CO 3 and LiOH impurities into a beneficial functional surface coating comprising phosphates. Specifically, hydro-phosphates were used as the functional surface modification agents to mitigate the detrimental effect of surface residuals. The best electrochemical performance was achieved by modifying LiNi 0.6 Mn 0.2 Co 0.2 O 2 with a diluted dihydro-phosphate solution (pKa = 7.2), while the metal cation had a negligible impact on the electrochemical performance. This work provides a cheap and simple method for enabling the high performance of nickel-rich cathodes.

25 ENERGY STORAGE↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Achieving extraordinary thermal stability of salt hydrate eutectic composites by amending crystallization behaviour with thickener

Commercial thermal energy storage (TES) systems necessitate reliable thermal performance throughout their operational lifetime. Repeated volume changes of the phase change materials (PCMs) during thermal cycling disengages thermal contacts between the conductive fillers like expanded graphite (EG) in TES composites, causing unstable thermal conductivity (k) that fades with cycling. Our in-operando crystallization studies on eutectic PCM made of zinc nitrate hexahydrate (ZNH) and KNO 3 revealed that the thermal stability of PCM composites can be considerably degraded by the formation of large and sharp-cornered PCM crystals during the freezing cycle. While the crystals can push EG particles, disengaging thermal contacts between them, we have newly discovered that carboxymethyl cellulose (CMC) can be used to retain the thermal contacts by forming networks of smaller PCM crystals. Furthermore, the scalable synthesis methodology of EG/ZNH eutectic composites was introduced. Here, in this study, EG particles were strongly connected into a matrix via a stable, corrosion resistant polydimethylsiloxane (PDMS) binder, stabilizing thermal networks and thereby maintaining k up to 1000 melt/freeze cycles. The thermal conductivity of our 25 vol% EG sample (13.3 W m -1 K -1 ) is more than 48% higher than other salt hydrate eutectic composites reported in the literature. We expect this study to provide insights on cooperative interaction between different components of TES systems (PCM, filler, thickener, binder) for exceptionally robust thermal properties.

36 MATERIALS SCIENCE↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗