Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spallation source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Advances in utilizing event based data structures for neutron scattering experiments

This article strives to expand on existing work to demonstrate advancements in data processing made available using event mode measurements. Most spallation neutron sources in the world have data acquisition systems that provide event recording. The new science that is enabled by utilizing event mode has only begun to be explored. In the past, these studies were difficult to perform because histograms forced dealing with either large chunks of time or a large number of files. With event based data collection, data can be explored and rebinned long after the measurement has completed. This article will review some of the principles of event data and how the method opens up new possibilities for in situ measurements, highlighting techniques that can be used to explore changes in the data. We also demonstrate the statistical basis for determining data quality and address the challenge of determining how long to measure mid-measurement. Lastly, we demonstrate a model independent method of grouping data via hierarchical clustering methods that can be used to improve calibration, reduction, and data exploration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

43 PARTICLE ACCELERATORS↗

3D-printed B 4 C collimation for neutron pressure cells

A design for an incident-beam collimator for the Paris–Edinburgh pressure cell is described here. This design can be fabricated from reaction-bonded B 4 C but also through fast turnaround, inexpensive 3D-printing. 3D-printing thereby also offers the opportunity of composite collimators whereby the tip closest to the sample can exhibit even better neutronic characteristics. Here, we characterize four such collimators: one from reaction-bonded B 4 C, one 3D-printed and fully infiltrated with cyanoacrylate, a glue, one with a glue-free tip, and one with a tip made from enriched 10 B 4 C. The collimators are evaluated on the Spallation Neutrons and Pressure Diffractometer of the Spallation Neutron Source and the Wide-Angle Neutron Diffractometer at the High Flux Isotope Reactor, both at Oak Ridge National Laboratory. This work clearly shows that 3D-printed collimators perform well and also that composite collimators improve performance even further. Beyond use in the Paris–Edinburgh cell, these findings also open new avenues for collimator designs as clearly more complex shapes are possible through 3D printing. An example of such is shown here with a collimator made for single-crystal samples measured inside a diamond anvil cell. These developments are expected to be highly advantageous for future experimentation in high pressure and other extreme environments and even for the design and deployment of new neutron scattering instruments.

47 OTHER INSTRUMENTATION↗

Methods for neutron diffraction studies on hydride superconductors and other metal hydrides

High-pressure neutron diffraction is an extremely useful technique in the quest for making and understanding novel hydride superconductors. Neutron diffraction can be used to directly determine elemental stoichiometries and atomic positions of many light elements such as hydrogen or deuterium, even in the presence of heavy elements such as rare-earth metals. In this work, we report on the current status and ongoing developments on high-pressure neutron diffraction for hydride superconductors and other metal hydrides with a special focus on current advancements at the Spallation Neutrons and Pressure (SNAP) beamline of the Spallation Neutron Source at Oak Ridge National Laboratory. For broader context, an overview of high-pressure neutron diffractometers and pressure cells is included together with insight into critical sample considerations. There, attention is given to the requirements for powdered hydride samples and the need for deuterium rather than hydrogen. Additionally, the advantages of angular access and data representation as possible at SNAP are described. We demonstrate the current capability for high-pressure neutron diffraction on two different samples created via hydrogen gas loading, specifically pure deuterium and nickel-deuteride. The deuterium example highlights the usefulness of adding sample materials that facilitate the formation of a good powder while the nickel-deuteride example demonstrates that atomic deuterium positions and stoichiometry can be directly determined. Both examples highlight the importance of large scattering apertures. These enable investigation of the data resolved by scattering angle that is needed to identify parasitic peaks and background features. Finally, future directions beyond current high-pressure neutron powder diffraction are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Magnetic pair distribution function data using polarized neutrons and ad hoc corrections

Here, we report the first example of magnetic pair distribution function (mPDF) data obtained through the use of neutron polarization analysis. Using the antiferromagnetic semiconductor MnTe as a test case, we present high-quality mPDF data collected on the HYSPEC instrument at the Spallation Neutron Source using longitudinal polarization analysis to isolate the magnetic scattering cross section. Clean mPDF patterns are obtained for MnTe in both the magnetically ordered state and the correlated paramagnet state, where only short-range magnetic order is present. We also demonstrate significant improvement in the quality of high-resolution mPDF data through the application of ad hoc corrections that require only minimal human input, minimizing potential sources of error in the data processing procedure. We briefly discuss the current limitations and future outlook of mPDF analysis using polarized neutrons. Overall, this work provides a useful benchmark for mPDF analysis using polarized neutrons and provides an encouraging picture of the potential for routine collection of high-quality mPDF data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementation of a laser–neutron pump–probe capability for inelastic neutron scattering

Knowledge about nonequilibrium dynamics in spin systems is of great importance to both fundamental science and technological applications. Inelastic neutron scattering (INS) is an indispensable tool to study spin excitations in complex magnetic materials. However, conventional INS spectrometers currently only perform steady-state measurements and probe averaged properties over many collision events between spin excitations in thermodynamic equilibrium, while the exact picture of re-equilibration of these excitations remains unknown. In this paper, we report on the design and implementation of a time-resolved laser–neutron pump–probe capability at hybrid spectrometer (beamline 14-B) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. This capability allows us to excite out-of-equilibrium magnons with a nanosecond pulsed laser source and probe the resulting dynamics using INS. Here, we discussed technical aspects to implement such a capability in a neutron beamline, including choices of suitable neutron instrumentation and material systems, laser excitation scheme, experimental configurations, and relevant firmware and software development to allow for time-synchronized pump–probe measurements. We demonstrated that the laser-induced nonequilibrium structure factor is able to be resolved by INS in a quantum magnet. In conclusion, the method developed in this work will provide SNS with advanced capabilities for performing out-of-equilibrium measurements, opening up an entirely new research direction to study out-of-equilibrium phenomena using neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A convergence metric for counting statistics in time-resolved small angle neutron scattering

Here, this work introduces a model-independent, dimensionless metric for predicting optimal measurement duration in time-resolved small-angle neutron scattering using early-time data. Built on a Gaussian process regression framework, the method reconstructs scattering profiles with quantified uncertainty, even from sparse or noisy measurements. Demonstrated on the EQ-SANS instrument at the Spallation Neutron Source, the approach generalizes to general SANS instruments with a two-dimensional detector. A key result is the discovery of a dimensionless convergence metric revealing a universal power-law scaling in profile evolution across soft matter systems. When time is normalized by a system-specific characteristic time t*, the variation in inferred profiles collapses onto a single curve with an exponent between −2 and −1. This trend emerges within the first ten time steps, enabling early prediction of measurement sufficiency. The method supports real-time experimental optimization and is especially valuable for maximizing efficiency in low-flux environments such as compact accelerator-based neutron sources.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

An algebraic convolution formulation for multiple-scattering correction in small-angle neutron scattering

Multiple scattering in small-angle neutron scattering (SANS) redistributes spectral weight and distorts structural interpretation, particularly for thick or strongly scattering samples. We develop a finite-dimensional spectral desmearing framework that corrects multiple scattering without resorting to integral transforms or model-dependent extrapolation. The primary intensity is expanded in an orthonormal basis adapted to the isotropic transverse-momentum measure, under which convolution reduces to a recursive tensor contraction, allowing the Poisson-weighted multiple-scattering series to be evaluated directly in a finite-dimensional basis representation. This formulation yields a stable forward–inverse mapping between apparent and primary spectra. Numerical tests demonstrate convergence under repeated convolution and accurate recovery of the single-scattering intensity. Application to SANS measurements collected at multiple neutron facilities, including the Spallation Neutron Source, the High Flux Isotope Reactor, and the Institut Laue-Langevin, shows the quantitative reconstruction of the underlying primary spectrum across a wide range of transmission conditions, including strongly attenuating samples. Here, the method provides a stable, model-agnostic framework for multiple-scattering correction in SANS and enables consistent structural interpretation across instruments and scattering regimes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Methodology for Generating Covariance Data of Thermal Neutron Scattering Cross Sections

This paper details and implements a framework for evaluating thermal neutron scattering cross sections that provide S(α,β) data and covariance data for hydrogen in light water. This methodology involves perturbing model parameters of molecular dynamics potentials and fitting the simulation results to experimental data. The framework is general and can be applied to any material or simulation method. The fit is made using the Unified Monte Carlo method to experimentally measure double-differential scattering cross sections of light water at the Spallation Neutron Source at Oak Ridge National Laboratory. Mean values and covariance data were generated for model parameters, phonon density of states, double-differential cross sections, and total scattering cross sections. These posterior parameter values were very similar to their prior values with a maximum relative error of 0.54%. This falls within in the Unified Monte Carlo–calculated uncertainties on the order of 2.7%. Additionally, posterior double-differential cross sections agree favorably with ENDF/B-VIII.0 cross sections. The new thermal scattering law was tested by comparing it against benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook, which showed a slight improvement over the ENDF/B-VIII.0 library. Additionally, the covariance matrix of the phonon density of states was validated to confirm that the spread of k eff from the density of states used to generate the covariance matrix was similar to the spread of k eff from the density of states of the sampled covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗

Wide-angle diamond cell for neutron scattering

Here, a new diamond cell with extreme apertures is described. It is tailored for a large variety of neutron scattering techniques such as inelastic neutron scattering and single-crystal diffraction both at the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Simple springs enable forces of over 10 metric tons to be clamped in for low-temperature measurements. At present, low-cost polycrystalline diamond (Versimax ® ) pressure anvils are used. We predict a routine pressure regime up to 20 GPa with sample volumes of ~0.5 mm3. Future use of large CVD single-crystal diamond anvils will significantly expand this pressure range. We show examples for measurements at the SNAP, VISION and CORELLI beamlines of the SNS.

42 ENGINEERING↗

Modified Bridgman anvils for high pressure synthesis and neutron scattering

A simple modified Bridgman design for large volume pressure anvils usable in the Paris-Edinburgh (PE) press has been demonstrated at Oak Ridge National Laboratory Spallation Neutron Source. The design shows advantages over the toroidal anvils typically used in the PE press, mainly rapid compression/decompression rates, complete absence of blow-outs upon drastic phase transitions, simplified cooling, high reliability, and relative low loads (~40 tons) corresponding to relatively high pressures (~20 GPa). It also shows advantages over existing large-volume diamond cells as sample volumes of ~2-3 mm 3 can be easily and rapidly synthesized. The anvils thus allow sample sizes sufficient for in situ neutron diffraction as well as rapid synthesis of adequate amounts of new materials for ex situ analysis via total neutron scattering and neutron spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic ordering in rare earth metal dysprosium revealed by neutron diffraction studies in a large-volume diamond anvil cell

A high-pressure low-temperature neutron diffraction study has been carried out on rare earth metal Dysprosium (Dy) to 10.8 GPa and 8 K in a large-volume diamond anvil cell using a spallation neutron source. Dy crystallizes in an ambient pressure hexagonal close packed phase and forms an incommensurate helical antiferromagnetic phase, marked by the appearance of superlattice magnetic peaks below 176 K with a turn-angle between the hexagonal layers that increases both with increasing temperature and pressure. The ferromagnetic transition below 87 K is marked by an increase in intensity of nuclear peaks with disappearance of magnetic superlattice reflections. Dy transforms to an alpha-Samarium ( α-Sm ) phase at 7 GPa and only ferromagnetic ordering is observed for this high pressure phase. Here, the ferromagnetic transition is observed at 59 K in the α-Sm phase at 10.8 GPa in close agreement with the magnetic ordering temperature obtained from electrical transport measurements. In the entire pressure-temperature range of this study, Dy shows a negative thermal expansion coefficient of as much as -2.5 % in the magnetically ordered phases between 200 K and 8 K.

36 MATERIALS SCIENCE↗

A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons↗

New precision measurements of free neutron beta decay with cold neutrons

Precision measurements in free neutron beta decay serve to determine the coupling constants of beta decay, and offer several stringent tests of the standard model. This study describes the free neutron beta decay program planned for the Fundamental Physics Beamline at the Spallation Neutron Source at Oak Ridge National Laboratory, and finally puts it into the context of other recent and planned measurements of neutron beta decay observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Figure-of-Merit for a Cold Coupled Moderator at the SNS Second Target Station suited for Direct Geometry Inelastic Spectrometers

The suite of moderators for the Second Target Station (STS) at the Spallation Neutron Source (SNS) in Oak Ridge is currently undergoing the planning stage at which various options and configurations are being considered. The current plans for the instrument suite include two direct geometry inelastic spectrometers, CHESS and HERTZ, which will receive beam from cold moderators and work mostly in the 1-20 meV incident energy range. CHESS will be a relatively short (wide bandwidth) instrument that is dedicated to studying small samples (∼mm3) with coarse energy resolution (2.5 – 5% of Ei). HERTZ on the other hand will be designed to achieve very good energy resolution, 1 – 3% of Ei, using a long secondary flightpath with a ∼ 4 × 4 cm2 beam on sample. In this contribution, we will discuss the implications of these design requirements for the optimal moderator pulse width, and for the repetition rate that would be best suited for the spectrometers.

Ehlers, Georg↗