Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Radiopurity assessment of the energy readout for the NEXT double beta decay experiment

In this study, the "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136 Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr'aneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4×10 –4 counts keV –1 kg –1 y –1 , satisfying the sensitivity requirements of the NEXT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metal–Organic Framework-Based Microfluidic Impedance Sensor Platform for Ultrasensitive Detection of Perfluorooctanesulfonate

The growing global concerns to public health from human exposure to perfluorooctanesulfonate (PFOS) requires rapid, sensitive, in-situ detection where current, state-of-the-art techniques are yet to adequately meet sensitivity and selectivity standards of the real-world. This work presents, for the first time, a synergistic approach for the targeted affinity-based capture of PFOS using a porous sorbent probe that enhances detection sensitivity by embedding it on a microfluidic conductive platform. This novel sorbent-containing platform functions as an electrochemical sensor to directly measure PFOS concentration through a proportional change in electrical response (increase in impedance). The extremely high surface area and pore volume of mesoporous metal-organic framework (MOF) Cr-MIL-101 is used as the probe for targeted PFOS capture based on the affinity of the chromium center towards both the fluorine tail groups as well as the sulfonate functionalities as demonstrated by spectroscopic (NMR and XPS) and microscopic (TEM) studies. Answering the need for an ultrasensitive PFOS detection technique, we are embedding these MOF capture probes inside a microfluidic channel, sandwiched between interdigitated microelectrodes (IDµE). The nanoporous geometry increases the signal to noise ratio of interdigitated microelectrodes tremendously increasing sensitivity; this in combination with the ability of the capture probes to interact with the PFOS at the molecular level and effectively transduce that response electrochemically has allowed us achieve a PFOS detection limit of 0.5 ng/L, which is unprecedented for in-situ analytical PFOS sensors and even comparable to quantification limits achieved using state-of-the-art ex situ techniques.

36 MATERIALS SCIENCE↗

Monitoring of corrosion effects in pipes with multi-mode acoustic signals

Current commercial long-range guided wave inspection and monitoring technologies for pipes usually require establishment of certain specific acoustic modes for wave propagation and use a large number of sensors in a certain geometric arrangement (for example, uniformly-spaced arrays of sensors on a collar, placed around a pipe). This paper, in contrast, presents a long-range corrosion detection method in pipes based on multi-mode guided acoustic waves, generated and received using simple, single-element sensors. In this technique, available guided wave modes in any interrogated zone of the structure are automatically down-selected by the medium, and changes in energy distribution over the selected modes are analyzed through signal processing to monitor material loss or addition. Here, to investigate the feasibility of the proposed method, we have performed both experimental and numerical simulation studies on 50.8-mm (2-in)-diameter schedule-40 carbon steel pipes. In these studies, a linear chirp signal is injected in compression mode, perpendicular to the surface of the pipe, generating multi-mode, multi-directional guided waves that travel within the pipe wall. Corrosion effects in the pipes are simulated numerically and experimentally. To reduce errors in the measurement technique due to changes in the local or global temperature of the measured media, a universal temperature compensation algorithm is introduced. The experimental results show good agreement with simulation results, indicating that the proposed multi-mode wave generation and detection in a pipe could be used for long-range detection and monitoring of corrosion effects, such as pipe wall losses or solid material deposits.

36 MATERIALS SCIENCE↗

A longitudinal study of ventilation rates in California office buildings and self-reported occupant outcomes including respiratory illness absence

Limited evidence has associated lower ventilation rates (VRs) in offices with higher illness-related absence rates. We studied spaces in office buildings, selected without knowledge of their VRs, in three California climate zones. In each study space, real-time logging sensors measured carbon dioxide and thermal parameters for one year. Web-based surveys every three months collected data on occupants’ health outcomes. Using multivariate models, relationships were assessed between CO 2 concentrations, or VRs estimated from CO 2 , and adverse occupant outcomes including respiratory infections and illness absences. For all outcomes, positive associations were hypothesized with higher CO 2 levels (and negative associations with higher VRs). Low survey response limited sample size and study power. In the 16 study spaces, CO 2 concentrations were uniformly low over the year, and most estimated VRs ranged from twice to nine times the California office minimum VR standard (7 L/s or 15 cfm per person). Primary CO 2 and VR metrics had no statistically significant relationships with occupant outcomes. Within the observed range of uniformly low CO 2 and high VRs (mostly 16–42 L/s per person), little variation in contaminant concentrations would be expected, which would explain lack of relationships with occupant outcomes. These high VRs resulted partly from frequently used energy-saving “economizer” cycles in moderate California climates, but VRs at other times also substantially exceeded required VRs. These findings suggest, consistent with theory, that within a higher VR range, increased VRs do not reduce respiratory illness. Further studies are needed to better characterize such relationships.

60 APPLIED LIFE SCIENCES↗

Sequential Perturbation-based FDIA Detection using DERs for Unbalanced Distribution System

The power distribution system with its reliance on automated monitoring and control infrastructure makes it a complicated cyber-physical system and vulnerable to various cyber-attacks. This paper proposes a moving target defense inspired false data injection attack (FDIA) detection mechanism for an unbalanced distribution system. In the proposed grid diagnosis service framework, the distribution system operator judiciously manipulates power outputs of a subset of inverter-based distribution energy resources (DERs) to create secret low magnitude voltage perturbations which are inconsequential to the normal operation of the grid. A mixed-integer-linear-programming algorithm is developed to select the optimal set of DERs that can create a voltage perturbation signal of the required magnitude at each sensor location at a minimum cost. Then, a sequential detector is applied that detects for the FDIA as measurements are received from individual sensors. The performance of the proposed perturbation-based FDIA detection framework is demonstrated via simulation of the IEEE 123 bus test system.

Attack Detection↗

MO-F-CAMPUS-T-05: Design of An Innovative Beam Monitor for Particle Therapy for the Simultaneous Measurement of Beam Fluence and Energy

Purpose: Monitoring the prescribed dose in particle therapy is typically carried out by using parallel plate ionization chambers working in transmission mode. The use of gas detectors has several drawbacks: they need to be calibrated daily against standard dosimeters and their dependence on beam quality factors need to be fully characterized and controlled with high accuracy. A detector capable of single particle counting is proposed which would overcome all these limitations. Combined with a gas ionization chamber, it will allow determining the average particle stopping power, thus providing an effective method for the online verification of the selected particle energy and range. Methods: Low-Gain Avalanche Detectors (LGADs) are innovative n-in-p silicon sensors with moderate internal charge multiplication occurring in the strong field generated by an additional p+ doping layer implanted at a depth of a few µm in the bulk of the sensor. The increased signal-to-noise ratio allows designing very thin, few tens of microns, segmented LGADs, called Ultra Fast Silicon Detectors (UFSD), optimized for very fast signal, which would be suitable for charged particle counting at high rates. A prototype UFSD is being designed for this purpose. Results: Different LGAD diodes have been characterized both in laboratory and beam tests, and the results compared both with those obtained with similar diodes without the gain layer and with a program simulating the signal in the sensors. The signal is found to be enhanced in LGADs, while the leakage current and the noise is not affected by the gain. Possible alternative designs and implementations are also presented and discussed. Conclusion: Thanks to their excellent counting capabilities, UFSD detectors are a promising technology for future beam monitor devices in hadron-therapy applications. Studies are ongoing to better understand their properties and optimize the design in view of this application.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Co-Registered In-Situ and Ex-Situ Dataset from a Laser Powder Bed Fusion Additive Manufacturing Process (Peregrine v2023-10)

This release contains a co-registered in-situ and ex-situ Peregrine dataset from a single Concept Laser M2 Laser Powder Bed Fusion (L-PBF) stainless steel 316L build. These data were collected at the Manufacturing Demonstration Facility (MDF) located at Oak Ridge National Laboratory (ORNL). The dataset includes layer-wise visible-light in-situ imaging data, the laser scan paths and parameters, in-situ temporal sensor data, X-Ray Computed Tomography (X-CT) scans, pycnometry and tensile test results, etched micrographs from selected locations, and the target part geometries. Additionally, anomaly detections produced by a modified Dynamic Segmentation Convolutional Neural Network (DSCNN) are provided.

36 MATERIALS SCIENCE↗

Creating a Discovery Platform for Confined-Space Chemistry and Materials: Metal-Organic Frameworks

Metal organic frameworks (MOF) are a recently discovered class of nanoporous, defect-free crystalline materials that enable rational design and exploration of porous materials at the molecular level. MOFs have tunable monolithic pore sizes and cavity environments due to their crystalline nature, yielding properties exceeding those of most other porous materials. These include: the lowest known density (91% free space); highest surface area; tunable photoluminescence; selective molecular adsorption; and methane sorption rivaling gas cylinders. These properties are achieved by coupling inorganic metal complexes such as ZnO4 with tunable organic ligands that serve as struts, allowing facile manipulation of pore size and surface area through reactant selection. MOFs thus provide a discovery platform for generating both new understanding of chemistry in confined spaces and novel sensors and devices based on their unique properties. At the outset of this project in FY06, virtually nothing was known about how to couple MOFs to substrates and the science of MOF properties and how to tune them was in its infancy. An integrated approach was needed to establish the required knowledge base for nanoscale design and develop methodologies integrate MOFs with other materials. This report summarizes the key accomplishments of this project, which include creation of a new class of radiation detection materials based on MOFs, luminescent MOFs for chemical detection, use of MOFs as templates to create nanoparticles of hydrogen storage materials, MOF coatings for stress-based chemical detection using microcantilevers, and "flexible" force fields that account for structural changes in MOFs that occur upon molecular adsorption/desorption. Eight journal articles, twenty presentations at scientific conferences, and two patent applications resulted from the work. The project created a basis for continuing development of MOFs for many Sandia applications and succeeded in securing $\$$2.75 M in funding from outside agencies to continue the research.

Allendorf, Mark D.↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗

Enhanced detection of volatile organic compounds (VOCs) by caffeine modified carbon nanotube junctions

Detection of vapor phase analytes and gas molecules is primarily essential for numerous applications including medical diagnostic, environmental monitoring, chemical threat detection, food quality control, and chemical warfare agents. Here, we developed Caffeine functionalized carbon nanotubes (CNTs) random network based vapor quantum resistive sensors (vQRSs) for volatile organic compounds (VOCs) detection. The localized transmission electron microscopy (TEM) image and energy dispersive X-ray spectroscopy (EDS) confirm migration of caffeine to CNT–CNT junction (CNTj). We have recorded more than one order of magnitude higher sensitivity and unique selectivity towards selective VOCs (e.g., acetone, toluene, ethanol, methanol, etc.) with short response time (few seconds) for caffeine modified CNT junction (Caf-CNTj) vQRSs. Molecular dynamics (MD) calculations suggest that the sensitivity of the sensor is diffusion limited, with an advective contribution for ethanol. Furthermore, the designed Caf-CNTj sensors can potentially be important candidate to be a part of electronic nose used for various application such as breath analysis and food quality monitoring.

36 MATERIALS SCIENCE↗

Investigation of High Temperature Silica Based Fiber Optic Materials (Final Report)

This report summarizes technical progress during the program “Investigation of High Temperature Silica Based Fiber Optic Materials”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to investigate and characterize the performance of commercially available optical fibers at elevated temperatures in replicated fuel gas streams. It also includes performing a comprehensive study of the interactions with the chemical constituents with respect to structural, optical, and mechanical stability and developing design strategies to assure reliable performance of deployed optical fibers and sensors. In the eight quarters of the project, work was done to complete the database of test results and findings for the creation of an optical fiber selection guide for high temperature applications. It is anticipated that this design tool will provide the scientific community with the information necessary to deploy sensing systems with the most robust and reliable fused silica optical fibers. Standard telecommunications grade germanium doped single and multimode fibers have been shown to perform reliably up to temperatures of 1100°C in non-hydrogen environments and/or properly designed sensor applications. Pure silica core single mode and low OH, large core step index multimode fibers, which have also shown to perform reliability up to temperatures of 1000ºC, are recommended for hydrogen and moist environments.

36 MATERIALS SCIENCE↗

Hydrogen-bond Specific Materials Modification in Group IV Semiconductors

Semiconductor dielectric crystals consist of two fundamental components: lattice atoms and electrons. The former component provides a crystalline structure that can be disrupted by various defects or the presence of an interface, or by transient oscillations known as phonons. The latter component produces an energetic structure that is responsible for the optical and electronic properties of the material, and can be perturbed by lattice defects or by photo-excitation. Over the period of this project, August 15, 1999 to March 31, 2015, a persistent theme has been the elucidation of the fundamental role of defects arising from the presence of radiation damage, impurities (in particular, hydrogen), localized strain or some combination of all three. As our research effort developed and evolved, we have experienced a few title changes, which reflected this evolution. Throughout the project, ultrafast lasers usually in a pump-probe configuration provided the ideal means to perturb and study semiconductor crystals by both forms of excitation, vibrational (phonon) and electronic (photon). Moreover, we have found in the course of this research that there are many interesting and relevant scientific questions that may be explored when phonon and photon excitations are controlled separately. Our early goals were to explore the dynamics of bond-selective vibrational excitation of hydrogen from point defects and impurities in crystalline and amorphous solids, initiating an investigation into the behavior of hydrogen isotopes utilizing a variety of ultrafast characterization techniques, principally transient bleaching spectroscopy to experimentally obtain vibrational lifetimes. The initiative could be divided into three related areas: (a) investigation of the change in electronic structure of solids due to the presence of hydrogen defect centers, (b) dynamical studies of hydrogen in materials and (c) characterization and stability of metastable hydrogen impurity states under transient compression. This research focused on the characterization of photon and ion stimulated hydrogen related defect and impurity reactions and migration in solid state matter, which requires a detailed understanding of the rates and pathways of vibrational energy flow, of the transfer channels and of the coupling mechanisms between local vibrational modes (LVMs) and phonon bath as well as the electronic system of the host material. It should be stressed that researchers at Vanderbilt and William and Mary represented a unique group with a research focus and capabilities for low temperature creation and investigation of such material systems. Later in the program, we carried out a vigorous research effort addressing the roles of defects, interfaces, and dopants on the optical and electronic characteristics of semiconductor crystals, using phonon generation by means of ultrafast coherent acoustic phonon (CAP) spectroscopy, nonlinear characterization using second harmonic generation (SHG), and ultrafast pump-and-probe reflectivity and absorption measurements. This program featured research efforts from hydrogen defects in silicon alone to other forms of defects such as interfaces and dopant layers, as well as other important semiconducting systems. Even so, the emphasis remains on phenomena and processes far from equilibrium, such as hot electron effects and travelling localized phonon waves. This program relates directly to the mission of the Department of Energy. Knowledge of the rates and pathways of vibrational energy flow in condensed matter is critical for understanding dynamical processes in solids including electronically, optically and thermally stimulated defect and impurity reactions and migration. The ability to directly probe these pathways and rates allows tests of theory and scaling laws at new levels of precision. Hydrogen embedded in model crystalline semiconductors and metal oxides is of particular interest, since the associated local mode can be excited cleanly, and is usually well-separated in energy from the phonon bath. These basic dynamical studies have provided new insights for example into the fundamental mechanisms that control proton diffusion in these oxides. This area of materials science has largely fulfilled its promise to identify degradation mechanisms in electronic and optoelectronic devices, and to advance solid oxide proton conductors for fuel cells, gas sensors and proton-exchange membrane applications. It also provides the basis for innovations in materials synthesis involving atomic-selective diffusion and desorption.

36 MATERIALS SCIENCE↗

Real-time and Autonomous Water Quality Monitoring System Based on Remotely Operated Vehicle

Existing water quality monitoring systems near hydropower facilities are limited by the lack of mobility of the sensors’ carrier platform. Most systems use a buoy, a mounting fixture attached to a solid structure, or a human worker, which significantly limits the selection of the sampling sites and poses safety risks during data collection and equipment maintenance. To improve on this technology, we developed an autonomous water quality monitoring system that can operate in dangerous water environments near hydropower facilities for water sampling at multiple locations. The goal is to enable safe, timely, and comprehensive water-quality data collection; maximize power generation revenue with improved operational control; and reduce Federal Energy Regulatory Commission and state water quality monitoring costs for compliance. The system incorporates a remotely operated vehicle as the mobile monitoring platform, a dissolved oxygen sensor for monitoring water quality, a tether management system for automatically winding the tether, a solar mobile docking platform for suppling power to the ROV, and a web-based graphical user interface for data post-processing and visualization. In addition, preliminary field research are presented to demonstrate the system capabilities.

Salalila, Aljon L.↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

Advanced Control Architecture and Sensor Information Development for Process Automation, Optimization, and Imaging of Chemical Looping Systems

The Syngas Chemical Looping (SCL) process developed at The Ohio State University (OSU) uses an iron-based oxygen carrier to convert syngas into high-purity hydrogen while simultaneously capturing carbon dioxide that is readily sequestrable. A 25 kWth sub-pilot unit was successfully demonstrated multiple times on the OSU Clean Coal Research Facility, and a 250 kWth – 3 MWth pilot demonstration unit has been designed and constructed at the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The focus of this project is to develop multiple technologies to automate the startup and shutdown of chemical looping system. Success of this project will propel the advanced carbon capture method toward commercialization, hence be disruptive to the fossil fuel and power industries. Advanced process automation control architecture and imaging and optimization sensor software were developed for OSU chemical looping process. A high-level controller (HLC) consisting of decision-making and controller-selection logic integrated with sliding mode controllers (SMCs) were developed to perform chemical looping process startup and shutdown. Babcock & Wilcox Power Generation Group’s FocalPoint Optimization System was implemented to optimize the process operating conditions. The process automation controller and optimization information were realized and tested on OSU’s existing sub-pilot chemical looping test unit under atmospheric condition. The implemented control architecture was able to perform the complete process procedure from startup, steady-state reaction operation to shutdown with minimal operator intervention. The controller was also implemented on the pressurized syngas chemical looping (SCL) pilot test unit constructed at the National Carbon Capture Center (NCCC), demonstrating its pressure control capability with a designed transient state trajectory. An electrical capacitance volume tomography (ECVT) sensor device and its software were developed to image the packed moving bed and slugging fluidized bed of oxygen carriers in chemical looping systems at elevated temperatures. The ECVT device constructed was capable of tracking the subtle voidage variance along the moving bed axis as a feature for directly measuring the oxygen carrier particles’ linear velocity. Also, the high temperature ECVT device was used to study the fluidization characteristics of Geldart Group D particles.

08 HYDROGEN↗

Picosecond laser structuring of thin film platinum layers covered with tantalum pentoxide isolation

A thin film layer system consisting of platinum (Pt) as conductive layer on a glass substrate and tantalum pentoxide as isolating layer on top of the platinum is attractive for designing biocompatible conductor paths and contact pads for bio sensor chips. For the flexible and rapid patterning of the conductive and the isolating layers, both, the complete removal and the selective ablation of the individual thin films were investigated using ultra-short laser pulses with about 10 ps pulse duration and 1064 nm wavelength at low laser fluences. A platinum film covered with tantalum pentoxide shows a significantly lower ablation threshold than a single Pt film on glass alone when illuminated from the front side. Furthermore, we explored that the tantalum pentoxide film can be removed by glass side illumination from the Pt film, without affecting the Pt film and leaving the Pt film on the glass substrate intact. Those ablation phenomena occur at laser fluences of about 0.2 J/cm{sup 2}, far below the evaporation limit of platinum. We present a detailed ablation threshold value examination for the structuring of these layer systems by front side and glass side irradiation for different film thicknesses. Furthermore, we discuss the possible underlying physical mechanisms of these ablation phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Voltammetry measurements in lithium chloride-lithium oxide (LiCl–Li 2 O) salt: An evaluation of working electrode materials

Instrumentation to provide process monitoring (PM) and safeguards for the oxide reduction (OR) step in the electrochemical processing of used oxide nuclear fuel is necessary to ensure equipment is operated as declared. Cyclic voltammetry (CV) has been proposed for real-time monitoring of the operation of an OR process for safeguards purposes. In this study, different materials including 316 stainless steel (SS), tantalum (Ta), molybdenum (Mo), tungsten (W), platinum (Pt), and iridium (Ir) were evaluated as potential working electrode (WE) materials based on their chemical inertness, corrosion resistance, and sensitivity in detecting Li 2 O and other chloride salts in the OR electrolyte. Of the electrodes evaluated, 316 SS, Ir, and Pt all performed reasonably well in the LiCl-Li 2 O electrolyte. Here, stainless steel was operated in the cathodic potential and had reasonable corrosion resistance and is relatively inexpensive. Iridium could be operated in both the cathodic and anodic potentials and was the most corrosion resistant of those evaluated. Platinum is limited to the anodic potential range, had reasonable corrosion resistance, and was the most sensitive to Li 2 O concentrations in the salt. In the development of a stand-alone safeguards instrumentation, our recommendation is a CV sensor fitted with both Ir and Pt WEs. The results in this study may also be helpful for anode material selection in other electrometallurgy industries, such as molten salt electrolysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗