Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

kasacrspeccwrhicopol

Ka-Band ARM Scanning Cloud Radar (KASACR) Filtered Spectral Data of Cross-Wind RHI Scan in Co-Polarization Mode

54 ENVIRONMENTAL SCIENCES↗

wsacrspeccwrhicopol

W-Band ARM Scanning Cloud Radar (KASACR) Filtered Spectral Data of Cross-Wind RHI Scan in Co-Polarization Mode

54 ENVIRONMENTAL SCIENCES↗

kasacrspeccwrhixpol

Ka-Band ARM Scanning Cloud Radar (KASACR) Filtered Spectral Data of Cross-Wind RHI Scan in Cross-Polarization Mode

54 ENVIRONMENTAL SCIENCES↗

wsacrspeccwrhixpol

W-Band ARM Scanning Cloud Radar (KASACR) Filtered Spectral Data of Cross-Wind RHI Scan in Cross-Polarization Mode

54 ENVIRONMENTAL SCIENCES↗

wsacrspecvpthsccopol

W-Band ARM Scanning Cloud Radar (KASACR) Filtered Spectral Data of Vertically Pointing High Sensitivity Scan in Co-Polarization Mode

54 ENVIRONMENTAL SCIENCES↗

wsacrspecvpthscxpol

W-Band ARM Scanning Cloud Radar (KASACR) Filtered Spectral Data of Vertically Pointing High Sensitivity Scan in Cross-Polarization Mode

54 ENVIRONMENTAL SCIENCES↗

Short-range laser obstacle detector

Detector, designed for slow-moving vehicle to explore surface of Mars, will automatically divert vehicle from obstacles as small as 0.5 m in its path. Detector comprises injection laser operating in pulse time-delay measurement, or radar, mode. It is capable of scanning area extending from few meters to approximately 30 m.

Kuriger, W. L.↗

An investigation of the optimization of parameters affecting the implementation of fourier transform spectroscopy at 20-500 micron from the C-141 airborne infrared observatory

A program for 20-500 micron spectroscopy from the NASA flying C141 infrared observatory is being carried out with a Michelson interferometer. The parameters affecting the performance of the instrument are studied and an optimal configuration for high performance on the C-141 aircraft is recommended. As each parameter is discussed the relative merits of the two modes of mirror motion (rapid scan or step and integrate) are presented.

Thompson, R. I.↗

Velocity surveys in a turbine stator annular-cascade facility using laser Doppler techniques

A laser Doppler velocimeter (LDV) was used to determine the flow conditions downstream of an annular cascade of stator blades operating at an exit critical velocity ratio of 0.87. Two modes of LDV operation (continuous scan and discrete point) were investigated. Conventional pressure probe measurements were also made for comparison with the LDV results. Biasing errors that occur in the LDV measurement of velocity components were also studied. In addition, the effect of pressure probe blockage on the flow conditions was determined with the LDV. Photographs and descriptions of the test equipment used are given.

Goldman, L. J.↗

Thematic Mapper image quality - Registration, noise, and resolution

The Landsat-4 satellite has two new imaging radiometers, including the redesigned Multispectral Scanner (MSS) and the Thematic Mapper (TM). The present investigation is concerned with an assessment of TM image quality on the basis of a study of band-to-band registration, periodic noise, and spatial resolution. In the TM images analyzed, the band-to-band registration accuracy of the instrument is very good. A few imperfections were found. Once a stable misregistration is removed, the TM should also meet its registration specifications between focal planes. Spatial resolution analyses in terms of MTF were performed in comparison modes. The forward and backward scans were shown to have virtually identical MTFs.

Wrigley, R. C.↗

Imaging graphite in air by scanning tunneling microscopy - Role of the tip

Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.

Colton, R. J.↗

On the design issues for a spaceborne rain mapping radar

The design concept for the spaceborne rain mapping radar for the Tropical Rain Measuring Mission (TRMM) of Thiele (1987) is examined. The TRMM requirements for sampling strategy, spatial and height resolutions, observable altitude, and rain rate measurement range are described. The adaptive scanning and nadir Doppler measurement modes for the radar are discussed.

Li, F. K.↗

Low cost paths to binary optics

Application of binary optics has been limited to a few major laboratories because of the limited availability of fabrication facilities such as e-beam machines and the lack of standardized design software. Foster-Miller has attempted to identify low cost approaches to medium-resolution binary optics using readily available computer and fabrication tools, primarily for the use of students and experimenters in optical computing. An early version of our system, MacBEEP, made use of an optimized laser film recorder from the commercial typesetting industry with 10 micron resolution. This report is an update on our current efforts to design and build a second generation MacBEEP, which aims at 1 micron resolution and multiple phase levels. Trails included a low cost scanning electron microscope in microlithography mode, and alternative laser inscribers or photomask generators. Our current software approach is based on Mathematica and PostScript compatibility.

Nelson, Arthur↗

High Resolution Observations of Drop Size Distribution for GPM Ground Validation

During the Mid-latitude Continental Convective Cloud Experiment (MC3E), NASA's GPM GV Disdrometer and Radar Observations of Precipitation (DROP) Facility deployed an array of disdrometers and rain gauges in northern Oklahoma to sample, with high resolution, the drop size distribution for use in development of precipitation retrieval algorithms for the GPM core satellites. The DROP Facility instruments deployed during MC3E consisted of 16 autonomous Parsivel units, 5 two-dimensional video disdrometers (2dvds), a vertically pointing K band radar, and 32 tipping bucket rain gauges. There were several rainfall events during MC3E in which rain drops exceeding 6 mm in diameter were recorded. The disdrometer array revealed large rain drops with diameters exceeding 6 mm and 8 mm during two separate stratiform and convective rainfall events, respectively. The NPOL radar, which was scanning in high resolution RHI mode (every 40 sec) over the disdrometer array during the stratiform event, indicated a 1 km thick bright band with a differential reflectivity column of 2-3 dB extending below the melting layer to the surface where the large drops were recorded by the 2dvds. These large drops are important for GPM since they can have a great impact upon satellite precipitation retrieval, especially near the ground and below heavy convective rainfall cores where satellites have had problems depicting the rainfall.

Gatlin, Patrick N.↗

DEFECT DETECTION USING DYNAMIC ANALYSIS FOR ADDITIVE MANUFACTURED METALS

Additive manufacturing (AM) has the ability to produce parts with complex geometries and internal features, however, for demanding applications such as the automotive and aerospace industries, it is crucial that the parts can meet the demanding functional and geometric requirements. Quality control for AM parts focuses on nondestructive methods of testing, but many of the current methods are expensive and time-consuming. The research presented in this report explores various methods of nondestructive evaluation (NDE) using dynamic analysis on stainless steel parts produced with selective laser melting (SLM). Methods include, but are not limited to, frequency response functions (FRF), impedance-based measurements, and scanning laser doppler vibrometry. Additionally, mode shape analysis was performed in MATLAB and FEA simulations were used for comparison with experimental results. The results indicate that dynamic analysis has the potential to be a feasible method of defect detection and NDE in AM parts and future work should focus on refining these methods, such as optimizing test parameters to improve sensitivity to defects.

Deonarain, Gita↗

SAMSI: An orbiting spatial interferometer for micro-arc second astronomical observations

The concept and performance of (SAMSI) Spacecraft Array for Michelson Spatial Interferometry, an orbiting spatial interferometer comprised of three free-flying spacecraft, two collector telescopes and a central mixing station are described. In the one-dimensional interferometry mode orbits exist which provide natural scanning of the baseline. These orbits place extremely small demands on thrusters and fuel consumption. Resolution of 0.00001 arcsecond and magnitude limits of mv = 15 to 20 are achievable in a single orbit. In the imaging mode, SAMSI could synthesize images equivalent to those produced by equal diameter filled apertures in space, making use of the fuel resupply capability of a space station. Simulations indicate that image reconstruction can be performed with milliarcsecond resolution to a visual magnitude 12 in 12 hr of spiral scanning integration time.

Stachnik, R. V.↗

Experimental Modal Analysis on a Rotating Fan Using Tracking-CSLDV

Continuous Scan Laser Doppler Vibrometry (CSLDV) modifies the traditional mode of operation of a vibrometer by sweeping the laser measurement point continuously over the structure while measuring, enabling one to measure spatially detailed mode shapes quickly and minimizing the inconsistencies that can arise if the structure or test conditions change with time. When a periodic scan path is employed, one can decompose the measurement into the response that would have been measured at each point traversed by the laser and obtain the structure's mode shapes and natural frequencies using conventional modal analysis software. In this paper, continuous-scan vibrometry is performed on a rotating fan, using computer controlled mirrors to track the rotating fan blades while simultaneously sweeping the measurement point over the blades. This has the potential to circumvent the difficulty of attaching contact sensors such as strain gauges, which might modify the structure and invalidate the results. In this work, impact excitation was used to excite a 3-blade fan rotating at various speeds, and the blades were scanned with a cloverleaf pattern that captured the bending of all three blades simultaneously. Some specialized signal processing is helpful in minimizing the effect of rotation frequency harmonics in the measurements, and specific scan strategies are needed to avoid those frequencies, both of these issues are discussed in the paper. While noise in the laser vibrometer does pose some difficulty, the results show that several modes could be extracted and that the tracking-CSLDV results agree with measurements obtained from the parked fan.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A One-Dimensional Synthetic-Aperture Microwave Radiometer

A proposed one-dimensional synthetic- aperture microwave radiometer could serve as an alternative to either the two-dimensional synthetic-aperture radiometer described in the immediately preceding article or to a prior one-dimensional one, denoted the Electrically Scanned Thinned Array Radiometer (ESTAR), mentioned in that article. The proposed radiometer would operate in a pushbroom imaging mode, utilizing (1) interferometric cross-track scanning to obtain cross-track resolution and (2) the focusing property of a reflector for along-track resolution. The most novel aspect of the proposed system would be the antenna (see figure), which would include a cylindrical reflector of offset parabolic cross section. The reflector could be made of a lightweight, flexible material amenable to stowage and deployment. Other than a stowage/deployment mechanism, the antenna would not include moving parts, and cross-track scanning would not entail mechanical rotation of the antenna. During operation, the focal line, parallel to the cylindrical axis, would be oriented in the cross-track direction, so that placement of receiving/radiating elements at the focal line would afford the desired along-track resolution. The elements would be microwave feed horns sparsely arrayed along the focal line. The feed horns would be oriented with their short and long cross-sectional dimensions parallel and perpendicular, respectively, to the cylindrical axis to obtain fan-shaped beams having their broad and narrow cross-sectional dimensions parallel and perpendicular, respectively, to the cylindrical axis. The interference among the beams would be controlled in the same manner as in the ESTAR to obtain along-cylindrical- axis (cross-track) resolution and cross-track scanning.

Doiron, Terence↗