Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

High-resolution extreme-ultraviolet spectroscopy of potassium using anti-Stokes radiation

The use of a new extreme-ultraviolet radiation source based on spontaneous anti-Stokes scattering for high-resolution absorption spectroscopy of transition originating from the 3p6 shell of potassium is reported. The region from 546.6 to 536.8 A is scanned at a resolution of about 1.2 Kayser. Within this region, four previously unreported lines are observed.

Rothenberg, J. E.↗

Lunar sample analysis

A wide variety of lunar sample and meteorite studies were performed. Abstracts of the most recent reports are also attached. Experimental techniques employed have included scanning electron microscopy, transmission electron microscopy, Mossbauer spectroscopy, atomic absorption analysis and a variety of simulation studies.

Housley, R. M.↗

Correction of WindScat Scatterometric Measurements by Combining with AMSR Radiometric Data

The Seawinds scatterometer on the advanced Earth observing satellite-2 (ADEOS-2) will determine surface wind vectors by measuring the radar cross section. Multiple measurements will be made at different points in a wind-vector cell. When dense clouds and rain are present, the signal will be attenuated, thereby giving erroneous results for the wind. This report describes algorithms to use with the advanced mechanically scanned radiometer (AMSR) scanning radiometer on ADEOS-2 to correct for the attenuation. One can determine attenuation from a radiometer measurement based on the excess brightness temperature measured. This is the difference between the total measured brightness temperature and the contribution from surface emission. A major problem that the algorithm must address is determining the surface contribution. Two basic approaches were developed for this, one using the scattering coefficient measured along with the brightness temperature, and the other using the brightness temperature alone. For both methods, best results will occur if the wind from the preceding wind-vector cell can be used as an input to the algorithm. In the method based on the scattering coefficient, we need the wind direction from the preceding cell. In the method using brightness temperature alone, we need the wind speed from the preceding cell. If neither is available, the algorithm can work, but the corrections will be less accurate. Both correction methods require iterative solutions. Simulations show that the algorithms make significant improvements in the measured scattering coefficient and thus is the retrieved wind vector. For stratiform rains, the errors without correction can be quite large, so the correction makes a major improvement. For systems of separated convective cells, the initial error is smaller and the correction, although about the same percentage, has a smaller effect.

Song, S.↗

Satellite-Based Stratospheric and Tropospheric Measurements: Determination of Global Ozone and Other Trace Species

This grant is an extension to our previous NASA Grant NAG5-3461, providing incremental funding to continue GOME (Global Ozone Monitoring Experiment) and SCIAMACHY (SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY) studies. This report summarizes research done under these grants through December 31, 2002. The research performed during this reporting period includes development and maintenance of scientific software for the GOME retrieval algorithms, consultation on operational software development for GOME, consultation and development for SCIAMACHY near-real-time (NRT) and off-line (OL) data products, and participation in initial SCIAMACHY validation studies. The Global Ozone Monitoring Experiment was successfully launched on the ERS-2 satellite on April 20, 1995, and remains working in normal fashion. SCIAMACHY was launched March 1, 2002 on the ESA Envisat satellite. Three GOME-2 instruments are now scheduled to fly on the Metop series of operational meteorological satellites (Eumetsat). K. Chance is a member of the reconstituted GOME Scientific Advisory Group, which will guide the GOME-2 program as well as the continuing ERS-2 GOME program.

Chance, Kelly↗

Microstructural Observations on Advanced Multilayer Protective Coatings for Nuclear Thermal Propulsion

The present research discusses the microstructures of a new multilayered coating concept proposed to solve the “midrange corrosion” problem observed in NbC and ZrC-coated graphite (Gr) nuclear fuels during the NERVA/Rover programs. The concept envisions designing a compliant multilayered coatings architecture to accommodate the thermal expansion mismatch strains between the ZrC outer coating and the Gr/(U,Zr)C fuel matrix along with using a diffusion barrier to minimize carbon and hydrogen diffusion, respectively. Multilayered coatings were deposited on Gr substrates by chemical vapor deposition (CVD). Graphite disks, as well as the inner channels of a 19-hole hexagonal rod 152.4 mm long, were coated by CVD in proof-of concept process demonstration studies. Coated disk specimens were thermally-cycled between ambient and 1900 K for as long as 20 cycles with a 1h hold time at the temperature using both stepped and non-interrupted thermal cycling methods. Detailed cross-sectional microstructural analyses were conducted on the thermally-cycled coated disks. These results showed that the coatings were intact after 20 thermal cycles at 1900 K although the bonding of the overlay Mo coating appeared to be influenced by the oxygen content in the layer. Seven transverse sections were cut along the length from the coated hexagonal rod for microstructural studies. All the nineteen channels were observed to have been coated in all the sections. This paper reports the results of detailed microstructural analyses, compositional line scans and x-ray dot maps conducted on three coated channels from a mid-section of the rod. The measured values of carbon (C) were observed to be exceptionally high in all the specimens, which were attributed to hydrocarbon contamination of the specimen surfaces. It was observed that the oxygen (O) levels were high in all the coating layers even after approximately correcting for the observed high values of C. The source of O contamination of the CVD reactor system was attributed to either the presence of oxychloride impurities in the precursor salts or a pin hole leak in the coating system. It is concluded that high values of O result in poor bonding of the Mo overlay to the ZrC layer. These trials have established that it is possible to deposit multilayered coatings by CVD in 19-hole hexagonal rods 152.4 mm long similar to the NERVA fuel rod design although the quality of the coatings and the uniformity of their thicknesses require further improvement.

Nuclear thermal propulsion, multilayer coatings, m↗

Laser wavelength effects in ultrafast near-field laser nanostructuring of Si

We study the effect of laser wavelength (400 nm and 800 nm) on the near-field processing of crystalline silicon (Si) in the femtosecond (fs) pulse duration regime through sub-wavelength apertures. Distinct differences in the obtained nanostructures are found in each case both in terms of their physical sizes as well as their structure which can be tuned between craters and protrusions. A single or a few fs pulses can deliver enough energy on the substrate to induce sub-diffraction limited surface modification, which is among the smallest ever reported in sub-wavelength apertured Near-field Scanning Optical Microscope (NSOM) schemes.

25 ENERGY STORAGE↗

Characterization of the alumina scale formed on a commercial MCrAlYHfSi coating

A commercial NiCoCrAlYHfSi coating deposited on a Ni-base superalloy substrate was characterized before and after high temperature oxidation. The combination of Y, Hf and Si additions are reported to improve coating performance. Advanced characterization techniques including scanning transmission electron microscopy were used to study the segregation behavior of Y and Hf ions to the alumina grain boundaries after 200h at 1050 C and 100 and 200h exposures at 1100 C. After both exposure times, two distinct oxide layers were observed. The outer transient layer included many Y- and Hf-rich oxide particles. The inner layer consisted of columnar -Al2O3 grains normal to the surface of the coating. Segregation of Y and Hf ions was found on the alumina grain boundaries as has been observed in model alloys with similar compositions. Isothermal exposures for up to 200h at 1050 and 1100 C caused a minimal increase in surface roughness. However, 200 one-hour cycles at 1100 C resulted in a more significant increase in surface roughness.

36 MATERIALS SCIENCE↗

Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDI{sub vol}

Purpose: The scanner-reported CTDI{sub vol} for automatic tube current modulation (TCM) has a different physical meaning from the traditional CTDI{sub vol} at constant mA, resulting in the dichotomy “CTDI{sub vol} of the first and second kinds” for which a physical interpretation is sought in hopes of establishing some commonality between the two.Methods: Rigorous equations are derived to describe the accumulated dose distributions for TCM. A comparison with formulae for scanner-reported CTDI{sub vol} clearly identifies the source of their differences. Graphical dose simulations are also provided for a variety of TCM tube current distributions (including constant mA), all having the same scanner-reported CTDI{sub vol}.Results: These convolution equations and simulations show that the local dose at z depends only weakly on the local tube current i(z) due to the strong influence of scatter from all other locations along z, and that the “local CTDI{sub vol}(z)” does not represent a local dose but rather only a relative i(z) ≡ mA(z). TCM is a shift-variant technique to which the CTDI-paradigm does not apply and its application to TCM leads to a CTDI{sub vol} of the second kind which lacks relevance.Conclusions: While the traditional CTDI{sub vol} at constant mA conveys useful information (the peak dose at the center of the scan length), CTDI{sub vol} of the second kind conveys no useful information about the associated TCM dose distribution it purportedly represents and its physical interpretation remains elusive. On the other hand, the total energy absorbed E (“integral dose”) as well as its surrogate DLP remain robust between variable i(z) TCM and constant current i{sub 0} techniques, both depending only on the total mAs = t{sub 0}=i{sub 0} t{sub 0} during the beam-on time t{sub 0}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamic functional imaging of brain glucose utilization using fPET-FDG

We report that glucose is the principal source of energy for the brain and yet the dynamic response of glucose utilization to changes in brain activity is still not fully understood. Positron emission tomography (PET) allows quantitative measurement of glucose metabolism using 2-[18F]-fluorodeoxyglucose (FDG). However, FDG PET in its current form provides an integral (or average) of glucose consumption over tens of minutes and lacks the temporal information to capture physiological alterations associated with changes in brain activity induced by tasks or drug challenges. Traditionally, changes in glucose utilization are inferred by comparing two separate scans, which significantly limits the utility of the method. We report a novel method to track changes in FDG metabolism dynamically, with higher temporal resolution than exists to date and within a single session. Using a constant infusion of FDG, we demonstrate that our technique (termed fPET-FDG) can be used in an analysis pipeline similar to fMRI to define within-session differential metabolic responses. We use visual stimulation to demonstrate the feasibility of this method. Ultimately, this new method has a great potential to be used in research protocols and clinical settings since fPET-FDG imaging can be performed with most PET scanners and data acquisition and analysis are straightforward. fPET-FDG is a highly complementary technique to MRI and provides a rich new way to observe functional changes in brain metabolism.

2-[18F]-fluorodeoxyglucose (FDG)↗

Salina Well

Computed tomography and core logger data presented in the technical report Mackey, P.; Paronish, T.; Brown, S; Crandall, D.; Dinterman, P.; Moore J. P.; Moore, J. Computed Tomography Scanning and Geophysical Measurements of the Salina Formation from the #36 Brine Well; NETL-TRS-21-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 64. DOE: 10.18141/1483799.

Core logging↗

Core Characterization of the Whipkey ST1 Well - Marcellus Shale

CT and geophysical data of the Marcellus from the Whipkey ST 1 well in Greene Co PA API No: 37-059-24715 latitude 39.9000020N, longitude -80.0199970W Please see the following technical report for further details. Crandall, D.; Moore, J.; Brown, S.; Mackey, P.; Carr, T. Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well NETL-TRS-X-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 54.

Computed Tomography↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Herrick Well

Data generated at the National Energy Technology Laboratory, Morgantown WV from the Herrick 3HM well. API 34-111-2-4401-00-00 Lat/Long = 39.6572 N/80.9847W Monroe County, Ohio Core obtained by Eclipse Resources. Please see the following report for additional details: Brown, S.; Crandall, D.; Moore, J.; Mackey, P.; Carr, T.; Panetta, B. CT Scanning and Geophysical Measurements of the Utica Formation from the Herrick 3H Well; NETL-TRS-X-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 94.

Computed Tomography↗

CT and Geophysical Data of Clinton Sandstone Cores from Ohio

Collection of computed tomography and multi-sensor core logger data of 12 wells in Ohio that intersect the Clinton Sandstone formation. This data is described along with well information in a technical report series document: Paronish, T.; Holleran, A.; Pohl, M.; Crandall, D.; Jarvis, K.; Workman, S.; Drosche, J.; McKisic, T.; Collins, C.; Thomas, M.; McDonald, J. Computed Tomography Scanning and Geophysical Measurements of the Clinton Sandstone in Ohio; DOE.NETL-2025.4949; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory, Morgantown, WV, 2025; p 68. https://doi.org/10.2172/2589262

AS↗

Spaceflight Effect on White Matter Structural Integrity

Recent reports of elevated brain white matter hyperintensity (WMH) counts and volume in postflight astronaut MRIs suggest that further examination of spaceflight's impact on the microstructure of brain white matter is warranted. To this end, retrospective longitudinal diffusion-weighted MRI scans obtained from 15 astronauts were evaluated. In light of the recent reports of microgravity-induced cephalad fluid shift and gray matter atrophy seen in astronauts, we applied a technique to estimate diffusion tensor imaging (DTI) metrics corrected for free water contamination. This approach enabled the analysis of white matter tissue-specific alterations that are unrelated to fluid shifts, occurring from before spaceflight to after landing. After spaceflight, decreased fractional anisotropy (FA) values were detected in an area encompassing the superior and inferior longitudinal fasciculi and the inferior fronto-occipital fasciculus. Increased radial diffusivity (RD) and decreased axial diffusivity (AD) were also detected within overlapping regions. In addition, FA values in the corticospinal tract decreased and RD measures in the precentral gyrus white matter increased from before to after flight. The results show disrupted structural connectivity of white matter in tracts involved in visuospatial processing, vestibular function, and movement control as a result of spaceflight. The findings may help us understand the structural underpinnings of the extensive spaceflight-induced sensorimotor remodeling. Prospective longitudinal assessment of the white matter integrity in astronauts is needed to characterize the evolution of white matter microstructural changes associated with spaceflight, their behavioral consequences, and the time course of recovery. Supported by a grant from the National Space Biomedical Research Institute, NASA NCC 9-58.

Lee, Jessica K.↗