Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampled value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Dimension-free path-integral molecular dynamics without preconditioning

Convergence with respect to imaginary-time discretization (i.e., the number of ring-polymer beads) is an essential part of any path-integral-based molecular dynamics (MD) calculation. However, an unfortunate property of existing non-preconditioned numerical integration schemes for path-integral molecular dynamics—including essentially all existing ring-polymer molecular dynamics (RPMD) and thermostatted RPMD (T-RPMD) methods—is that for a given MD time step, the overlap between the exact ring-polymer Boltzmann–Gibbs distribution and that sampled using MD becomes zero in the infinite-bead limit. This has clear implications for hybrid Metropolis Monte Carlo/MD sampling schemes, and it also causes the divergence with bead number of the primitive path-integral kinetic-energy expectation value when using standard RPMD or T-RPMD. We show that these and other problems can be avoided through the introduction of “dimension-free” numerical integration schemes for which the sampled ring-polymer position distribution has non-zero overlap with the exact distribution in the infinite-bead limit for the case of a harmonic potential. Most notably, we introduce the BCOCB integration scheme, which achieves dimension freedom via a particular symmetric splitting of the integration time step and a novel implementation of the Cayley modification [R. Korol et al., J. Chem. Phys. 151, 124103 (2019)] for the free ring-polymer half-steps. More generally, we show that dimension freedom can be achieved via mollification of the forces from the external physical potential. The dimension-free path-integral numerical integration schemes introduced here yield finite error bounds for a given MD time step, even as the number of beads is taken to infinity; these conclusions are proven for the case of a harmonic potential and borne out numerically for anharmonic systems that include liquid water. The numerical results for BCOCB are particularly striking, allowing for nearly three-fold increases in the stable time step for liquid water with respect to the Bussi–Parrinello (OBABO) and Leimkuhler (BAOAB) integrators, while introducing negligible errors in the calculated statistical properties and absorption spectrum. Importantly, the dimension-free, non-preconditioned integration schemes introduced here preserve ergodicity and global second-order accuracy, and they remain simple, black-box methods that avoid additional computational costs, tunable parameters, or system-specific implementations.

Korol, Roman (ORCID:0000000193076351)↗

Purdue University: Results of B-Value Tests for Rock Saturation

This dataset includes an Excel file with the results of B-value tests to determine the magnitude of the back pressure required for full saturation of Sierra White granite samples. Test were conducted on cylindrical rock specimens of Sierra White granite in a custom water pressurized chamber. Dimensions and properties of Sierra White granite specimens are summarized in the PDF file. The PDF file also includes a description of the B-value tests, experimental procedure, and results.

15 GEOTHERMAL ENERGY↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

Revealing the complex chemistry of grain boundaries in K-doped BaFe 2 As 2 with atom probe tomography

Iron-based superconductors have attractive properties for high-field applications, but there is a lack of understanding of the effect of grain boundary chemistry on the in-field performance. The near atomic-scale resolution, ppm sensitivity and 3D analysis offered by atom probe tomography make it a powerful tool to investigate the nanoscale structure and chemistry of these defects in fine-grained K-doped BaFe 2 As 2 samples. A computational method to systematically extract and compare the Gibbsian interfacial excess of chemical species across grain boundaries has been explored in this work. The robustness of the method has been tested by evaluating the effects of selected variables on simulated APT datasets. The accuracy and precision of the calculated Gibbsian interfacial excess were found to be stable over a range of analysis conditions: varying grain boundary widths and detection efficiencies, spatial precisions below 1.5 nm, and bin widths between 1.2 and 1.6 nm. For the K-doped BaFe 2 As 2 samples studied, segregation of As, Ba, K and impurities of O, Na, and Sb were found at grain boundaries. The Gibbsian excess values were found to vary widely between different boundaries, showing the complexity of the grain boundary chemistry in this material. Possible links between the observed critical current density (Jc) of these samples and their nano- and micro-structure have also been investigated and discussed.

36 MATERIALS SCIENCE↗

MIS Shelf-Life Final Report for Plutonium Oxide Item 1000089 (SSR136 and SSR136A) from Rocky Flats Peroxide Precipitation and Calcination Process

A plutonium dioxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample 1000089 represents product-quality plutonium oxides produced in the Rocky Flats peroxide precipitation process currently stored in 3013 containers. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/500th of the volume of a 3013 container. Gas compositions had been measured periodically over almost 13 years. The maximum observed gas pressure was 204 kPa and was related to a temperature excursion. The maximum observed gas pressure from gas generation was 126 kPa. The increase over the initial pressure of 86.7 kPa was due to the generation of hydrogen, oxygen, and nitrogen. Carbon dioxide, methane and carbon monoxide were minor components of the headspace gas. The material exhibited unusual behavior in that the atmosphere reached flammable levels of hydrogen and oxygen within the first 30 days and remained flammable for the duration of the experiment. It has been determined that the sample inside the reactor was a mixture of the AR material, material calcined at 800 °C, and material calcined at 950 °C. The experiment was terminated in 2012 and unloaded in 2016. A new reactor, SSR136A, was loaded with the original sample freshly calcined at 950 °C. The total pressure inside SSR136A remained close to the initial value of 93 kPa. The total pressure is composed of He (steady levels after the reloading) and hydrogen which is 10% of the reactor’s total pressure. Nitrogen and oxygen compose trace amounts of the reactor headspace. The internal components of SSR136 were inspected in 2021, five years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 4,576 days had an etched appearance, and pit-like features were observed in the microscopic analysis. No corrosion was observed on the SSR136A inner bucket that held the freshly calcined sample that was exposed for 1,303 days.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical report with results for 156Eu

The evaluated γ-ray branching ratio values after the decay of 156 Eu are based on measurements done in the 1960s and 1970s which improve upon measurements done back in the 1950s. These experiments, while improving on each other, were not able to produce nearly pure samples and impurities produced along with the sample ( 152 Eu, 154 Eu, and 155 Eu) interfered with the study of the beta spectrum for 156Eu. The values for the branching ratios of 156 Eu from National Nuclear Data Center (NNDC) [4] have uncertainties of ranging from 7-14% for the 10 most intense γ rays and up to 30% for the weaker ones. This work aims to improve the precision on the majority of these γ-ray branches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated quantum error mitigation based on probabilistic error reduction

Current quantum computers suffer from a level of noise that prohibits extracting useful results directly from longer computations. The figure of merit in many near-term quantum algorithms is an expectation value measured at the end of the computation, which experiences a bias in the presence of hardware noise. A systematic way to remove such bias is probabilistic error cancellation (PEC). PEC requires a full characterization of the noise and introduces a sampling overhead that increases exponentially with circuit depth, prohibiting high-depth circuits at realistic noise levels. Probabilistic error reduction (PER) is a related quantum error mitigation method that systematically reduces the sampling overhead at the cost of reintroducing bias. In combination with zero-noise extrapolation, PER can yield expectation values with an accuracy comparable to PEC.Noise reduction through PER is broadly applicable to near-term algorithms, and the automated implementation of PER is thus desirable for facilitating its widespread use. To this end, we present an automated quantum error mitigation software framework that includes noise tomography and application of PER to user-specified circuits. We provide a multi-platform Python package that implements a recently developed Pauli noise tomography (PNT) technique for learning a sparse Pauli noise model and exploits a Pauli noise scaling method to carry out PER.We also provide software tools that leverage a previously developed toolchain, employing PyGSTi for gate set tomography and providing a functionality to use the software Mitiq for PER and zero-noise extrapolation to obtain error-mitigated expectation values on a user-defined circuit.

McDonough, Benjamin↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid prediction of fuel research octane number and octane sensitivity using the AFIDA constant-volume combustion chamber

Current research octane number (RON) and motor octane number (MON) gasoline performance characterization techniques use dated, complex engine testing methodology and limit researchers’ ability to easily characterize small volumes of experimental fuels. A novel methodology is presented that correlates measured ignition delay (ID) time to RON in an Advanced Fuel Ignition Delay Analyzer (AFIDA) constant-volume combustion chamber device at a single pressure/temperature condition, with an r2 of 0.99 and standard error (SE) of 1.0. The correlation of the slope of the ID time between two additional temperature points to octane sensitivity (S) produces an r2 of 0.97 and SE of 0.69; however, fuels with S>12 are indistinguishable. These results are based on methodology calibration using 31 primary and toluene reference fuels containing 0%-40% ethanol with RON values ranging from 85 to 113. Validation of these methods using a 102-sample fuel matrix spanning an array of base fuels and additive chemistry designed to test the robust applicability of the method, along with pump gasoline and high-octane surrogate blend samples, demonstrates an r2 of 0.94 and SE of 1.3 for the RON correlation over all samples, whereas the equivalent S correlation produces an r2 of 0.78 and SE of 1.2 by excluding two additives, 3-pentanone and diisobutylene, which displayed poor S correlation results. This novel AFIDA analysis method can be performed in 1 h and with 40 mL of fuel, offering significant improvements in time and volume requirements over traditional techniques.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding the origin of softness in structurally tailored and engineered macromolecular (STEM) gels: A DPD study

Structurally tailored and engineered macromolecular (STEM) gels are polymer networks containing a primary network (the “STEM-0” gel) and side chains that are anchored to this network (forming the “STEM-1” gel). The ability to vary the features of the side chains provides a robust means of tailoring the macroscopic properties of the material. We use dissipative particle dynamics (DPD) simulations to determine the mechanical response of STEM-1 gels to uniaxial compression for various values of the side chain length, n sc . While the Young’s modulus of the material is significantly decreased with increasing n sc (at a fixed density of grafted side chains), above a certain saturation value, increasing n sc does not lead to any further softening of the sample. Using the simulations, we calculate the relevant stresses, which are related to the Young’s modulus and the number of entanglements in the network. We show that the backbone chains become more spread out upon addition of sidechains, leading to a decrease in the physical entanglements between backbone segments. This observation accounts for the decrease of stress in the backbone network and the softening of the networks through the addition of sidechains. For long chains, however, the number density of physical crosslinks between side chains is independent of side chain length; this observation explains the observed stress saturation in the STEM-1 gels. Our approach allows us to correlate the molecular architecture of the gels to the resultant macroscopic mechanical behavior and provide guidelines for fabricating STEM gels with well-defined mechanical properties, which allow the materials to be used for a variety of applications.

36 MATERIALS SCIENCE↗

Tropical lacustrine sediment microbial community response to an extreme El Niño event

Salinity can influence microbial communities and related functional groups in lacustrine sediments, but few studies have examined temporal variability in salinity and associated changes in lacustrine microbial communities and functional groups. To better understand how microbial communities and functional groups respond to salinity, we examined geochemistry and functional gene amplicon sequence data collected from 13 lakes located in Kiritimati, Republic of Kiribati (2° N, 157° W) in July 2014 and June 2019, dates which bracket the very large El Niño event of 2015–2016 and a period of extremely high precipitation rates. Lake water salinity values in 2019 were significantly reduced and covaried with ecological distances between microbial samples. Specifically, phylum- and family-level results indicate that more halophilic microorganisms occurred in 2014 samples, whereas more mesohaline, marine, or halotolerant microorganisms were detected in 2019 samples. Functional Annotation of Prokaryotic Taxa (FAPROTAX) and functional gene results (nifH, nrfA, aprA) suggest that salinity influences the relative abundance of key functional groups (chemoheterotrophs, phototrophs, nitrogen fixers, denitrifiers, sulfate reducers), as well as the microbial diversity within functional groups. Accordingly, we conclude that microbial community and functional gene groups in the lacustrine sediments of Kiritimati show dynamic changes and adaptations to the fluctuations in salinity driven by the El Niño-Southern Oscillation.

59 BASIC BIOLOGICAL SCIENCES↗

Microstructural stability and mechanical properties of the as-cast and heat-treated newly developed TiNbCrTa refractory complex concentrated alloy

In this study, a TiNbCrTa refractory complex concentrated alloy (RCCA) was prepared using vacuum arc remelting. The microstructural evolution and mechanical properties of both as-cast and heat-treated RCCA samples were analyzed. Heat treatment (HT) was performed at 800–1200 °C for 1 h in a vacuum-sealed environment. These samples exhibited a formation of Cr 2 Nb and Cr 2 Ti Laves phases. A variation in elemental distribution was observed, with interdendritic (ID) regions showing higher fractions of Ti and Cr, while the dendritic regions had a greater concentration of Ta and Nb. Micro-segregation at the IDs was confirmed through energy dispersive x-ray spectroscopy mapping, which inferred the formation of Cr- and Ti-rich phases during HT at 800–1200 °C. High-temperature HT at 1200 °C for 1 h led to the evolution of the hcp omega phase. Prolonged HT at 1200 °C for 96 h resulted in the evolution of a Cr-rich Laves phase (Cr 2 Ta), which was homogeneously distributed within the microstructure, indicating an unstable microstructure. Furthermore, despite prolonged HT, a variation in the elemental distribution persisted due to the presence of dendritic and ID regions. Electron backscattered diffraction analysis revealed the presence of bcc and hcp phases in the dendritic and ID regions, respectively, of the as-cast and HTed samples. The as-cast samples demonstrated a high compressive strength of approximately 2 GPa. Micro-hardness values increased with the HT temperature up to 1000 °C. Further increases under HT conditions did not significantly reduce the microhardness value, whereas prolonged HT at 1200 °C led to an increase in the microhardness value. Overall, the newly developed TiNbCrTa RCCA exhibited high-strength behavior even after the phase transformation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic tunnel junction random number generators applied to dynamically tuned probability trees driven by spin orbit torque

Abstract Perpendicular magnetic tunnel junction (pMTJ)-based true-random number generators (RNGs) can consume orders of magnitude less energy per bit than CMOS pseudo-RNGs. Here, we numerically investigate with a macrospin Landau–Lifshitz-Gilbert equation solver the use of pMTJs driven by spin–orbit torque to directly sample numbers from arbitrary probability distributions with the help of a tunable probability tree. The tree operates by dynamically biasing sequences of pMTJ relaxation events, called ‘coinflips’, via an additional applied spin-transfer-torque current. Specifically, using a single, ideal pMTJ device we successfully draw integer samples on the interval [0, 255] from an exponential distribution based on p -value distribution analysis. In order to investigate device-to-device variations, the thermal stability of the pMTJs are varied based on manufactured device data. It is found that while repeatedly using a varied device inhibits ability to recover the probability distribution, the device variations average out when considering the entire set of devices as a ‘bucket’ to agnostically draw random numbers from. Further, it is noted that the device variations most significantly impact the highest level of the probability tree, with diminishing errors at lower levels. The devices are then used to draw both uniformly and exponentially distributed numbers for the Monte Carlo computation of a problem from particle transport, showing excellent data fit with the analytical solution. Finally, the devices are benchmarked against CMOS and memristor RNGs, showing faster bit generation and significantly lower energy use.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamical Nonlinear Inversion of the Surface Photovoltage at Si(100)

A surface photovoltage (SPV) is observed whenever a doped semiconductor with non-negligible band bending is illuminated by light and charge carriers are excited across the band gap. The sign of the SPV depends on the nature of the doping, the amplitude of the SPV increases with the fluence of the light illumination up to a saturation value, which is determined by the doping concentration. We have investigated Si(100) samples with well-characterized doping levels over a wide range of illumination fluences. Surprisingly, the sign of the SPV upon illumination with 532 nm photons reverses for some p-doping concentrations at high fluences. This is a new effect associated with a crossover between electronic excitations in the bulk and at the surface of the semiconductor.

14 SOLAR ENERGY↗