Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Towards scanning nanostructure X-ray microscopy

This article demonstrates spatial mapping of the local and nanoscale structure of thin film objects using spatially resolved pair distribution function (PDF) analysis of synchrotron X-ray diffraction data. This is exemplified in a lab-on-chip combinatorial array of sample spots containing catalytically interesting nanoparticles deposited from liquid precursors using an ink-jet liquid-handling system. A software implementation is presented of the whole protocol, including an approach for automated data acquisition and analysis using the atomic PDF method. The protocol software can handle semi-automated data reduction, normalization and modeling, with user-defined recipes generating a comprehensive collection of metadata and analysis results. By slicing the collection using included functions, it is possible to build images of different contrast features chosen by the user, giving insights into different aspects of the local structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Effect of Interlayer Delay on the Heat Accumulation, Microstructures, and Properties in Laser Hot Wire Directed Energy Deposition of Ti-6Al-4V Single-Wall

Laser hot wire directed energy deposition (LHW-DED) is a layer-by-layer additive manufacturing technique that permits the fabrication of large-scale Ti-6Al-4V (Ti64) components with a high deposition rate and has gained traction in the aerospace sector in recent years. However, one of the major challenges in LHW-DED Ti64 is heat accumulation, which affects the part quality, microstructure, and properties of as-built specimens. These issues require a comprehensive understanding of the layerwise heat-accumulation-driven process–structure–property relationship in as-deposited samples. In this study, a systematic investigation was performed by fabricating three Ti-6Al-4V single-wall specimens with distinct interlayer delays, i.e., 0, 120, and 300 s. The real-time acquisition of high-fidelity thermal data and high-resolution melt pool images were utilized to demonstrate a direct correlation between layerwise heat accumulation and melt pool dimensions. The results revealed that the maximum heat buildup temperature of the topmost layer decreased from 660 °C to 263 °C with an increase to a 300 s interlayer delay, allowing for better control of the melt pool dimensions, which then resulted in improved part accuracy. Furthermore, the investigation of the location-specific composition, microstructure, and mechanical properties demonstrated that heat buildup resulted in the coarsening of microstructures and, consequently, the reduction of micro-hardness with increasing height. Extending the delay by 120 s resulted in a 5% improvement in the mechanical properties, including an increase in the yield strength from 817 MPa to 859 MPa and the ultimate tensile strength from 914 MPa to 959 MPa. Cooling rates estimated at 900 °C using a one-dimensional thermal model based on a numerical method allowed us to establish the process–structure–property relationship for the wall specimens. The study provides deeper insight into the effect of heat buildup in LHW-DED and serves as a guide for tailoring the properties of as-deposited specimens by regulating interlayer delay.

36 MATERIALS SCIENCE↗

Less is More: Bigger Data from Compressive Measurements

Compressive sensing approaches are beginning to take hold in (scanning) transmission electron microscopy (S/TEM) [1,2,3]. Compressive sensing is a mathematical theory about acquiring signals in a compressed form (measurements) and the probability of recovering the original signal by solving an inverse problem [4]. The inverse problem is underdetermined (more unknowns than measurements), so it is not obvious that recovery is possible. Compression is achieved by taking inner products of the signal with measurement weight vectors. Both Gaussian random weights and Bernoulli (0,1) random weights form a large class of measurement vectors for which recovery is possible. The measurements can also be designed through an optimization process. The key insight for electron microscopists is that compressive sensing can be used to increase acquisition speed and reduce dose. Building on work initially developed for optical cameras, this new paradigm will allow electron microscopists to solve more problems in the engineering and life sciences. We will be collecting orders of magnitude more data than previously possible. The reason that we will have more data is because we will have increased temporal/spatial/spectral sampling rates, and we will be able ability to interrogate larger classes of samples that were previously too beam sensitive to survive the experiment. For example consider an in-situ experiment that takes 1 minute. With traditional sensing, we might collect 5 images per second for a total of 300 images. With compressive sensing, each of those 300 images can be expanded into 10 more images, making the collection rate 50 images per second, and the decompressed data a total of 3000 images [3]. But, what are the implications, in terms of data, for this new methodology? Acquisition of compressed data will require downstream reconstruction to be useful. The reconstructed data will be much larger than traditional data, we will need space to store the reconstructions during analysis, and the computational demands for analysis will be higher. Moreover, there will be time costs associated with reconstruction. Deep learning [5] is an approach to address these problems. Deep learning is a hierarchical approach to find useful (for a particular task) representations of data. Each layer of the hierarchy is intended to represent higher levels of abstraction. For example, a deep model of faces might have sinusoids, edges and gradients in the first layer; eyes, noses, and mouths in the second layer, and faces in the third layer. There has been significant effort recently in deep learning algorithms for tasks beyond image classification such as compressive reconstruction [6] and image segmentation [7]. A drawback of deep learning, however, is that training the model requires large datasets and dedicated computational resources (to reduce training time to a few days). A second issue is that deep learning is not user-friendly and the meaning behind the results is usually not interpretable. We have shown it is possible to reduce the data set size while maintaining model quality [8] and developed interpretable models for image classification [9], but the demands are still significant. The key to addressing these problems is to NOT reconstruct the data. Instead, we should design computational sensors that give answers to specific problems. A simple version of this idea is compressive classification [10], where the goal is to classify signal type from a small number of compressed measurements. Classification is a much simpler problem than reconstruction, so 1) much fewer measurements will be necessary, and 2) these measurements will probably not be useful for reconstruction. Other simple examples of computational sensing include determining object volume or the number of objects present in the field of view [11].

Stevens, Andrew↗

NATALIE: A 32 detector integrated acquisition system to characterize laser produced energetic particles with nuclear techniques

We present a stand-alone system to characterize the high-energy particles emitted in the interaction of ultrahigh intensity laser pulses with matter. According to the laser and target characteristics, electrons or protons are produced with energies higher than a few mega electron volts. Selected material samples can, therefore, be activated via nuclear reactions. A multidetector, named NATALIE, has been developed to count the {beta}{sup +} activity of these irradiated samples. The coincidence technique used, designed in an integrated system, results in very low background in the data, which is required for low activity measurements. It, therefore, allows a good precision on the nuclear activation yields of the produced radionuclides. The system allows high counting rates and online correction of the dead time. It also provides, online, a quick control of the experiment. Geant4 simulations are used at different steps of the data analysis to deduce, from the measured activities, the energy and angular distributions of the laser-induced particle beams. Two applications are presented to illustrate the characterization of electrons and protons.

43 PARTICLE ACCELERATORS↗

Detection of phosphate transporter genes from arbuscular mycorrhizal fungi in mature tree roots under experimental soil pH manipulation

We present the majority of terrestrial plant roots are colonized by arbuscular mycorrhizal (AM) fungi that, in exchange for carbon, provide plants with enhanced nutrient uptake — most notably inorganic phosphate (P i ). To mediate the uptake of Pi from the soil, AM fungi possess high affinity inorganic phosphate transporters (PTs). Under laboratory conditions, P i concentrations have been shown to regulate AM fungal-specific PT gene expression. The relationship between PT expression and P i in the field remains unexplored. Here we quantify AM fungal-specific PTs from maple tree roots in situ. In an effort to limit edaphic parameters, root samples were collected from manipulated forested plots that had elevated soil P i availability, either through direct P i application or elevating pH to lower exchangeable aluminum. The aim of the study was to examine AM fungal-specific PT gene expression both prior to and following soil P i amendment; however, a direct correlation between soil P i concentration and PT gene expression was not observed. PT transcripts were detected to a greater extent under elevated pH and, while our results are confounded by an overall low detection of PT genes (23 % of all samples collected), our findings raise interesting questions regarding the role of soil pH on PT function. In conclusion, our study is a first step in understanding how edaphic properties influence PT expression and plant P acquisition in mature tree roots.

54 ENVIRONMENTAL SCIENCES↗

Advancing Terrestrial Ecosystem Science With a Novel Automated Measurement System for Sun‐Induced Chlorophyll Fluorescence for Integration With Eddy Covariance Flux Networks

Abstract Sun‐induced chlorophyll fluorescence (SIF) provides critical information on the dynamics of gross primary productivity, a unique role not readily achievable using other methods. Long‐term continuous SIF observations have the potential to advance terrestrial ecosystem science. Realizing this potential, however, requires synergistic implementation of SIF measurements within eddy covariance (EC) flux networks. There is a need for SIF systems that can integrate seamlessly with EC instrumentation to maximize synergistic use of obtained data. Here we introduce the Fluorescence Auto‐Measurement Equipment (FAME) and protocol that fulfill such a purpose. FAME is designed specifically for plug‐and‐play integration with existing EC data acquisition systems. Its innovative hardware and software designs provide versatility, extensibility, autonomous operation, and ease of maintenance for acquiring SIF data of high quality and quantity. A major novel feature of FAME is its synchronized sampling of spectral irradiance and environmental variables, allowing for more precise interpretation of the SIF signal. FAME has been deployed since September 2016 at the Missouri Ozark AmeriFlux site, providing high‐quality measurements even when air temperatures approached 40 °C. Results reveal that canopy SIF saturated or even slightly decreased at high light, similar to leaf‐level photosynthesis. Clear diurnal hysteresis was observed: For the same light, morning SIF was higher than afternoon. Dynamic energy dissipation processes and stress‐induced movements of chloroplasts and leaves may explain the observed pattern. The technology and measurement protocol introduced here advances the coordinated observation of SIF and EC fluxes and represents a step change in observational ecosystem and carbon cycle science research.

54 ENVIRONMENTAL SCIENCES↗

Protein and RNA dynamical fingerprinting

Protein structural vibrations impact biology by steering the structure to functional intermediate states; enhancing tunneling events; and optimizing energy transfer. Strong water absorption and a broad continuous vibrational density of states have prevented optical identification of these vibrations. Recently spectroscopic signatures that change with functional state were measured using anisotropic terahertz microscopy. The technique however has complex sample positioning requirements and long measurement times, limiting access for the biomolecular community. Here we demonstrate that a simplified system increases spectroscopic structure to dynamically fingerprint biomacromolecules with a factor of 6 reduction in data acquisition time. Using this technique, polarization varying anisotropy terahertz microscopy, we show sensitivity to inhibitor binding and unique vibrational spectra for several proteins and an RNA G-quadruplex. The technique’s sensitivity to anisotropic absorbance and birefringence provides rapid assessment of macromolecular dynamics that impact biology.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive, Active Learning, and Multifidelity Monte Carlo Methods in the MOOSE Stochastic Tools Module

MOOSE is an open-source computational platform for constructing multi-physics models and executing them in a massively parallel fashion. It has a stochastic tools module (STM) for forward/inverse uncertainty quantification (UQ) and surrogate modeling. This presentation details some recent developments to the STM with respect to the implementation of adaptive, active learning, and multifidelity Monte Carlo methods for forward UQ of computational models. Specifically, the adaptive Monte Carlo methods include Markov Chain Monte Carlo (MCMC)-driven algorithms like adaptive importance sampling and parallelized subset simulation for statistical QoI estimation, rare events analysis, and stochastic gradient-free optimization. The active learning methods include Gaussian Process (GP) surrogates and their training via Adam optimization, design of acquisition functions, and integration with samplers like Monte Carlo, adaptive importance, and parallelized subset simulation. These active learning methods are also designed to work in a batch mode, wherein, the required calls to the full computational model are executed in parallel whenever a user-specified batch size is met. The multifidelity methods in STM are broadly divided into two categories: hierarchical, where a defined hierarchy exists among the low-fidelity models, and peer, where all the low-fidelity models are treated equally. A GP surrogate is used to learn the differences between the low- and high-fidelity models in both multifidelity categories, and acquisition functions from the active learning classes are used to decide whether to rely on a low-fidelity model or call the expensive high-fidelity model. Alongside the software description and usage, applications are also presented to nuclear engineering computational models including a TRISO nuclear fuel particle, a reactor pressure vessel, and a heat-pipe microreactor.

97 MATHEMATICS AND COMPUTING↗

Searches for a sterile-neutrino admixture in detecting tritium decays in a proportional counter: New possibilities

An experiment aimed at searches for an admixture of a sterile neutrino whosemass is 1 to 8 keV via detecting electrons from tritium decay in a proportional counter is proposed. The admixture in question can be discovered by a specific distortion of the energy spectrum of these electrons. For the above masses, the distortion extends over the whole spectrum; therefore, use can bemade of detectors that have a relatively low energy resolution (about 10 to 15%). A classic proportional counter is a simple and natural choice of detector for the decays of a gaseous tritium. The approach that we propose is novel in two respects. On one hand, the proportional counter used is made as a discrete unit in the form of a fully fused quartz tube. This permits a readout of current signals directly from the anode filament and ensures a high stability in the case of long-term measurements. At the same time, the application of state-of-the-art digital data-acquisition methods will make it possible to perform measurements under conditions of high counting rates—up to 10{sup 6} Hz. As a result, the energy spectrum of electrons from tritium decays that is formed by 10{sup 12} counts could be accumulated within about a month. This data sample would make it possible to set an upper limit in the range of 10{sup −3}–10{sup −5} on a sterile-neutrino admixture at a confidence level of three standard deviations (3σ) for m{sub s} in the range of 1–8 keV, this being one to two orders of magnitude more stringent than present-day limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acquisition of STEM Images by Adaptive Compressive Sensing

Compressive Sensing (CS) allows a signal to be sparsely measured first and accurately recovered later in software [1]. In scanning transmission electron microscopy (STEM), it is possible to compress an image spatially by reducing the number of measured pixels, which decreases electron dose and increases sensing speed [2,3,4]. The two requirements for CS to work are: (1) sparsity of basis coefficients and (2) incoherence of the sensing system and the representation system. However, when pixels are missing from the image, it is difficult to have an incoherent sensing matrix. Nevertheless, dictionary learning techniques such as Beta-Process Factor Analysis (BPFA) [5] are able to simultaneously discover a basis and the sparse coefficients in the case of missing pixels. On top of CS, we would like to apply active learning [6,7] to further reduce the proportion of pixels being measured, while maintaining image reconstruction quality. Suppose we initially sample 10% of random pixels. We wish to select the next 1% of pixels that are most useful in recovering the image. Now, we have 11% of pixels, and we want to decide the next 1% of “most informative” pixels. Active learning methods are online and sequential in nature. Our goal is to adaptively discover the best sensing mask during acquisition using feedback about the structures in the image. In the end, we hope to recover a high quality reconstruction with a dose reduction relative to the non-adaptive (random) sensing scheme. In doing this, we try three metrics applied to the partial reconstructions for selecting the new set of pixels: (1) variance, (2) Kullback-Leibler (KL) divergence using a Radial Basis Function (RBF) kernel, and (3) entropy. Figs. 1 and 2 display the comparison of Peak Signal-to-Noise (PSNR) using these three different active learning methods at different percentages of sampled pixels. At 20% level, all the three active learning methods underperform the original CS without active learning. However, they all beat the original CS as more of the “most informative” pixels are sampled. One can also argue that CS equipped with active learning requires less sampled pixels to achieve the same value of PSNR than CS with pixels randomly sampled, since all the three PSNR curves with active learning grow at a faster pace than that without active learning. For this particular STEM image, by observing the reconstructed images and the sensing masks, we find that while the method based on RBF kernel acquires samples more uniformly, the one on entropy samples more areas of significant change, thus less uniformly. The KL-divergence method performs the best in terms of reconstruction error (PSNR) for this example [8].

Xie, Weiyi↗

Final Report on HOLODEC 2 Technology Readiness Level

During the period of this project, the Holographic Detector for Clouds 2 (HOLODEC 2) instrument has advanced from a laboratory-proven instrument with some initial field testing to a fully flight-tested instrument capable of providing useful cloud microphysics measurements. This can be summarized as 'Technology Readiness Level 8: Technology is proven to work - Actual technology completed and qualified through test and demonstration.' As part of this project, improvements and upgrades have been made to the optical system, the instrument power control system, the data acquisition computer, the instrument control software, the data reconstruction and analysis software, and some of the basic algorithms for estimating basic microphysical variables like droplet diameter. Near the end of the project, the instrument flew on several research flights as part of the IDEAS 2011 project, and a small sample of data from the project is included as an example. There is one caveat in the technology readiness level stated above: the upgrades to the instrument power system were made after the flight testing, so they are not fully field proven. We anticipate that there will be an opportunity to fly the instrument as part of the IDEAS project in fall 2012.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Compilation for AGC-2 Matrix-only Compact Lot A3-H08

This document is a compilation of fabrication and characterization data for the compact lot A3-H08, which was produced for possible insertion into the second ATR Graphite Creep irradiation test capsule (AGC-2). The compacts were produced by Oak Ridge National Laboratory (ORNL) for the Advanced Gas Reactor Fuel Development and Qualification (AGR) program. This compact lot was fabricated using a graphite/resin blend formulated by INL as a candidate matrix precursor for scale-up of overcoating and compacting processes. The matrix precursor powder for compact lot A3-H08 was a jet milled blend of 64 wt% natural graphite (Asbury 3482), 16 wt% synthetic graphite (Graftech GTI-D), and 20 wt% high purity novolac resin (Hexion D_SD-1708 with 7.5% hexamethylenetetramine added). The “Matrix Compacts for AGC-2 Irradiation” Specification (INL SPC-1285, Rev. 1) provides the requirements necessary for acceptance of the compacts. Sections 2.03 and 2.04 of SPC-1285 provide the property requirements for the heat-treated compacts. There are requirements on the length, diameter, and matrix density. Section 2.02.01.01 further requests impurity analysis on representative samples from the final compact lot, but there are no specified acceptance criteria. The impurity information will be evaluated by INL as part of a final decision on whether to insert the compacts into the AGC-2 experiment. The procedures for characterizing and qualifying the compacts are outlined in ORNL product inspection plan AGR-CHAR-PIP-16. The measurement of compact length, diameter, and matrix density was performed according to data acquisition method AGR-CHAR-DAM-39. The data report forms generated by this procedure document the product acceptance for the property requirements listed in sections 2.03 and 2.04 of SPC-1285. All compacts selected for irradiation conformed to the specified requirements for length, diameter, and density. In addition to the characterization data, this report also contains other records relevant to the product acceptance. A history of the material flow and sample naming is included and the compacting process is summarized. In addition to results of the impurity analysis on representative samples from the final compact lot, impurity analysis results are also provided for samples of the graphite, resin, and the graphite/resin blend. A Certificate of Conformance to SPC-1285, Rev. 1 is attached in Appendix B.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerating Structure–Property Relationship Discovery with Multimodal Machine Learning and Self-Driving Microscopy

Microscopy combined with local spectroscopy is widely used to correlate nanoscale structure with functional properties in materials, but conventional measurements rely heavily on human-selected sampling locations and predefined targets, limiting data set diversity and the potential for discovery. Here, we present a framework that integrates autonomous microscopy with dual-novelty deep kernel learning (DN-DKL) for adaptive data acquisition and a dual variational autoencoder (VAE) for representation learning. DN-DKL actively guides the microscopy toward structurally and spectroscopically novel regions, enabling efficient collection of large spectral data sets. Dual-VAE embeds local structures and spectroscopic responses into a shared latent manifold that serves as a structure–property relationship map. We applied this framework for the investigation of halide perovskite films by using conductive atomic force microscopy. The results reveal distinct hysteresis behaviors that are linked to specific nanoscale structural motifs, including grain boundary junction points that show hysteresis under different bias conditions and asymmetric grain boundaries that suppress the charge transport. This framework establishes a general strategy that leverages the complementary strengths of self-driving microscopy, machine learning, and human expertise to accelerate scientific discovery in functional materials.

atomic force microscopy↗

Nanoporous gold: a hierarchical and multiscale 3D test pattern for characterizing X-ray nano-tomography systems

Full-field transmission X-ray microscopy (TXM) is a well established technique, available at various synchrotron beamlines around the world as well as by laboratory benchtop devices. One of the major TXM challenges, due to its nanometre-scale resolution, is the overall instrument stability during the acquisition of the series of tomographic projections. The ability to correct for vertical and horizontal distortions of each projection image during acquisition is necessary in order to achieve the effective 3D spatial resolution. The effectiveness of such an image alignment is also heavily influenced by the absorption properties and strong contrast of specific features in the scanned sample. Here it is shown that nanoporous gold (NPG) can be used as an ideal 3D test pattern for evaluating and optimizing the performance of a TXM instrument for hard X-rays at a synchrotron beamline. Unique features of NPG, such as hierarchical structures at multiple length scales and high absorbing capabilities, makes it an ideal choice for characterization, which involves a combination of a rapid-alignment algorithm applied on the acquired projections followed by the extraction of a set of both 2D- and 3D-descriptive image parameters. This protocol can be used for comparing the efficiency of TXM instruments at different synchrotron beamlines in the world or benchtop devices, based on a reference library of scanned NPG samples, containing information about the estimated horizontal and vertical alignment values, 2D qualitative parameters and quantitative 3D parameters. The possibility to tailor the ligament sizes of NPG to match the achievable resolution in combination with the high electron density of gold makes NPG an ideal 3D test pattern for evaluating the status and performance of a given synchrotron-based or benchtop-based TXM setup.

36 MATERIALS SCIENCE↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sandia National Laboratories FY21 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY21 Sandia’s Neutron Effects Diagnostics (NEDs) and data acquisition systems were upgraded to test novel commercial off-the-shelf and Sandia-fabricated electronic components that support SNL’s National Security mission. The upgrades to the Sandia platform consisted of new cable chains, sample mount fixtures and a new fiber optics platform for testing optoelectronic devices.

42 ENGINEERING↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗