Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reuse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Management of Disused Sealed Sources in Austria - 12147

The use of sealed radiation sources is regulated by the Austrian Radiation Protection Act and the General Radiation Protection Ordinance. The Austrian radiation protection legislation requires minimisation of radioactive waste. The preferred radioactive waste management option concerning sealed sources, both spent and disused, is the return to the manufacturer. If this is not possible a reuse by a third party is encouraged. According to this requirement, disused sealed sources shall, as far as possible, be stored on the site of the licence holder until a new owner is found. If this is not possible, disused sealed sources shall be transported to Nuclear Engineering Seibersdorf, which is a recognised storage facility for radioactive waste in Austria, for temporary storage pending reuse. Sources, which cannot be reused, are declared as radioactive waste. Since Austria is a Member State of the European Union, the Council Directive 122/2003/Euratom on High Activity Sealed Sources and Orphan Sources is applied. This directive defines high activity sealed sources on the basis of their total activity. The possession of such sources is subject to certain obligations. Therefore it is in the interest of the owner to return disused sources as soon as possible to the manufacturer or to deliver them to Nuclear Engineering Seibersdorf. In case of the loss and finding of an 'orphan' source the competent authority secures, recovers and stores the source at the cost of the owner of the source with recourse. In line with the directive the licensee of a High Activity Sealed Source has to notify the main data concerning this source to the Central Source Register which is maintained by the Federal Minister of Agriculture, Forestry, Environment and Water Management for all radioactive sources. This register was put into operation in 2006. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Successful Implementation of Soil Segregation Technology at the Painesville FUSRAP Site - 12281

Typically the highest cost component of the radiological soils remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites is the cost to transport and dispose of the excavated soils, typically contaminated with naturally occurring isotopes of uranium, thorium and radium, at an appropriately permitted off-site disposal facility. The heterogeneous nature of the contamination encountered at these sites makes it difficult to accurately delineate the extent of contaminated soil using the limited, discrete sampling data collected during the investigation phases; and difficult to precisely excavate only the contaminated soil that is above the established cleanup limits using standard in-field scanning and guiding methodologies. This usually results in a conservative guided excavation to ensure cleanup criteria are met, with the attendant transportation and disposal costs for the larger volumes of soil excavated. To address this issue during the remediation of the Painesville FUSRAP Site, located in Painesville, Ohio, the Buffalo District of the U.S. Army Corps of Engineers, and its contractor, Safety and Ecology Corporation (SEC), employed automatic soil segregation technology provided by MACTEC (now AMEC) to reduce the potential for transportation and disposal of soils that met the cleanup limits. This waste minimization technology utilized gamma spectroscopy of conveyor-fed soils to automatically segregate the material into above and below criteria discharge piles. Use of the soil segregation system resulted in cost savings through the significant reduction of the volume of excavated soil that required off-site transportation and disposal, and the reduction of the amount of imported clean backfill required via reuse of 'below criteria' segregated soil as place back material in restoring the excavations. Measurements taken by the soil segregation system, as well as results of quality control sampling of segregated soils, confirmed that soils segregated as below criteria for reuse as site fill did meet the Record of Decision cleanup criteria for the site. Automatic soil segregation technology was successfully implemented as part of the 2010 - 2011 remediation effort at the Painesville FUSRAP Site. The Orion ScanSortSM system employed at the site demonstrated the ability to accurately determine the radioactivity concentrations in the processed soil and soil-like material and quickly segregate that material for appropriate final disposition. Data from the soil segregation system and confirmatory QC samples indicated that the segregated 'below criteria' soils met the cleanup criteria in the ROD, and was appropriate for reuse as fill in the excavations. The reduction of the total excavated soil volume requiring off-site disposal by 94% yielded significant project cost savings through reduction of transportation and disposal and backfill procurement costs. Use of automatic soil segregation technology was an efficient and cost-effective method for addressing the radiological contamination at the Painesville Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decommissioning of obsolete Nuclear Facilities in the UJV Rez, a. s. - 19027

UJV Rez, a. s. (further also UJV) is a leading institution in all areas of nuclear R and D in the Czech Republic and has had a dominant position in the nuclear program since it was established in 1955 as the Nuclear Research Institute Rez. The activities of UJV encompass nuclear physics, chemistry, nuclear power and many other topics. The main issues addressed at UJV in past decades have included research, development and services for NPPs, the fuel cycle and irradiation services for research and development in the industrial sector and medicine. UJV also manages most institutional radioactive wastes (RAW) produced in the Czech Republic (approx. 90 %). After more than 60 years of activities of the UJV in the nuclear field, there were obsolete nuclear facilities to be decommissioned. Decommissioning of nuclear facilities UJV is the only ongoing decommissioning project in the Czech Republic. Preparations for decommissioning began in 1996. Safety analysis report (SAR) was performed comprising the identification and characterization of potential sources of risk, potentially exposed receptors and exposure pathways, potential chemical compounds, radionuclides and media of concern. The results of the SAR enabled to determine the priorities of the decommissioning, the decommissioning the expenses and as well as project implementation. The decommissioning project was revised on the base of information obtained during decommissioning. The decommissioning was divided into two phases according to the level of risk and the financing limitations. The Ministry of Finance significantly financially contributed the decommissioning, although the UJV also contributed a considerable amount. Overall cost is close to the amount of Eur 27 million. Decommissioning started in 2003 and will be finished in 2018. Almost all facilities have already been successfully decommissioned. In the following table, the status of decommissioning of facilities is described. 1) Reloading site for RAW storage (Building 211/6): last item in progress 2003 - 2018; 2) Special Sewage System: decommissioned 2004 - 2005, reused; 3) Liquid RAW storage tanks (Building 211/3): decontaminated 2004 - 2013, reused; 4) Technology for RAW treatment (Building 241): decommissioned 2003 - 2011; 5) Contaminated equipment (Building 250): decommissioned 2003 - 2016; 6) Systems for storage of sealed sources (Building 261); decommissioned 2003 - 2005; 7) Decay tanks (Building 211/5); decommissioned 2003 - 2014, reused; 8) Old bituminating unit (Building 211/3); decommissioned 2004 - 2008; 9) Surface RAW storage site; decommissioned 2009 - 2014. Later, other unused decommissioning facilities, which were not included in the decommissioning project financed by the state, were included. These facilities are continuously decommissioned and financed from own resources of UJV. These facilities are like facilities already decommissioned: radiochemical laboratories, (including glove boxes), liquid RW storage tanks (including sewage systems), liquid RW treatment technology, hot cells, accumulated RW, etc. Realization started 2016 and expected duration is till 2026. Estimated budget is approximately Eur 17 million. The decommissioning of nuclear facilities in UJV is being carried out on the high level of radiation protection and up to now there was no extraordinary event or accident, although some challenges we were forced to address. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rejection of low-molecular weight neutral organics is highly sensitive to reverse osmosis system design and operation

A computational model was developed to investigate the significance of system design and operating conditions on the rejection of neutral, low-MW organics by reverse osmosis for potable reuse. Here, the model demonstrated that the decrease in local rejection as net driving pressure decreases is substantially greater for moderately rejected compounds than for highly rejected compounds. At recovery values less than 70%, the local permeate concentration can exceed the pressure vessel feed concentration for moderately rejected compounds. System-level rejection of moderately rejected compounds is likewise substantially more sensitive to operating conditions than highly rejected compounds. The findings highlight a drawback of relying on rejection results from bench-scale testing that operates at low recovery, which invariably has higher rejection than full-scale systems operating at similar pressure. The analysis demonstrates a trade-off in which the low-pressure, high-recovery operation desired for potable reuse systems can be detrimental to the removal of low-MW neutral organics. The removal of low-MW neutral organics can be improved if organics rejection is explicitly evaluated during the design process.

42 ENGINEERING↗

Life cycle assessment of the wood pallet repair and remanufacturing sector in the United States

Wood pallets are ubiquitous products that can be recovered and reused to enhance their service life and environmental performance. Repair/remanufacturing has an important role in extending the service life of the wood pallet. To quantify environmental performances of wood pallet reuse, this study developed representative life cycle inventory data for pallet repair/remanufacturing in the United States based on comprehensive industry-wide production data for 2018. A gate-to-gate life cycle assessment covering raw material supply, raw material transportation and pallet repair/remanufacturing showed that repair/remanufacturing often had the highest impacts, including primary energy consumption at 5.09 MJ and global warming impact at 0.355 kg CO 2 eq per repaired/remanufactured pallet. Electricity consumed onsite followed by nail input and the fuel used by forklifts during the manufacturing drove much of the impacts on the environment. Finally, the results of this study provide valuable information on the repair/remanufacturing impacts, allowing quantification and evaluation of the recovery stage on the overall environmental performance of wood pallets.

09 BIOMASS FUELS↗

Reliability-informed end-of-use decision making for product sustainability using two-stage stochastic optimization

The concept of circular economy has been diffused in recent decades to promote economic growth that does not add to the burden on natural resource extraction. Re-X options (e.g., reuse, repair, refurbish, remanufacture, recycle) have been gradually adopted in the product development process and optimized to reduce or eliminate waste and pollution. Although manufacturing incorporating Re-X options can be more environmentally friendly, it involves more sources of uncertainty than traditional manufacturing since the end-of-use products can be collected from multiple origins with various quantities and qualities, and the market demand for both new and remanufactured products cannot be forecasted perfectly. Thus, there is a need to optimize the Re-X policy to alleviate the negative impacts of the higher uncertainty. One option is using the reliability information of new products to estimate the end-of-use conditions and applying multi-stage stochastic optimization to capture multiple demand scenarios. This paper develops a two-stage stochastic optimization model to optimize the quality thresholds for reuse, recycling, and remanufacturing options. Our objective is to minimize the total cost, energy consumption, and environmental impact of producing and providing warranty service for a product family. The model employs reliability information of product components to estimate the warranty service cost and the end-of-use conditions of the returned resources. A case study on a general product family is implemented to illustrate the efficacy of the optimization model. Finally, results show that the two-stage optimization can achieve cost and environmental impact reduction for a hybrid manufacturing and remanufacturing process.

97 MATHEMATICS AND COMPUTING↗

Molecular beam epitaxy of GaAs templates on water soluble NaCl thin films

Expensive III-V substrates are cost limiting for the adoption of many technologies. Consequently, being able to reuse the original substrate is highly desirable. Existing substrate reuse techniques have significant drawbacks, but this work discusses a new method using molecular beam epitaxy deposition of water soluble NaCl thin films on commonly employed (0 0 1) GaAs substrates. Single-crystal GaAs templates are grown on continuous NaCl layers utilizing careful exposure of the NaCl to an in-situ electron beam and a low temperature nucleation layer. The template layers can be quickly removed from the substrate via dissolution of the NaCl. After liftoff, the original wafer shows an increase in rms surface roughness of only 0.2 nm.

14 SOLAR ENERGY↗

Predicting initial trans-membrane pressure across cycles in the ultrafiltration process using random forest

With growing freshwater scarcity, direct potable reuse (DPR) systems that reclaim wastewater for drinking are becoming increasingly important for sustainable water supply. Reliable operation requires minimizing downtime in ultrafiltration (UF) units, where membrane fouling leads to elevated trans-membrane pressure (TMP). This study develops data-driven regression models based on random forest (RF) and autoregressive (AR) approaches to forecast the initial TMP at the start of each UF filtration cycle in a pilot-scale DPR system. The RF model consistently outperforms baseline methods, including historical mean, last observation carried forward, and AR models, across multiple forecast horizons, achieving the lowest root mean square error. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent input variables across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is assessed for both direct and recursive RF modelling approaches. The proposed RF framework establishes a robust foundation for predictive monitoring and real-time optimization of UF operations, supporting sustainable and reliable water reuse.

direct potable reuse↗

Preliminary Environmental and Financial Viability Analysis of Circular Economy Scenarios for Satisfying PV System Service Lifetime

PV deployment has grown rapidly in recent decades, and this growth is expected to continue. At the same time, the rapid increase in PV panel efficiencies offers the opportunity to repower/revamp existing installations - replacing operational, lower-efficiency panels before the end of their 30-year service lifetime with newer, higher-efficiency panels. As a result, an increasing volume of PV panels could be decommissioned well before reaching the end of their 30-year service lifetime. Two broad strategies can be applied to manage the expected increase in decommissioned PV panels: (i) recycle prematurely decommissioned panels, and (ii) prevent recycling of these panels by satisfying the typical service lifetime of 30 years through circular economy strategies such as repair and reuse. Each strategy presents an environmental and economic trade-off. Retaining and satisfying the lifetime of the older, lower-efficiency panels avoids environmental burdens from recycling or landfilling but incurs burdens from additional repair and forgoing the opportunity to install newer panels with greater electricity-generation capabilities. This study assesses whether satisfying the expected service lifetime of a PV system through circular economy scenarios generates a greater environmental and financial benefit than recycling used panels and installing newer panels with higher efficiencies. The circular economy scenarios include repair and reuse of the PV system. Specifically, the study determines whether it is better for the environment to keep a PV panel in use for its 30-year service life after accounting for potential repair and additional transportation, or to replace older panels with more efficient new ones. In addition, we explore whether satisfying the service lifetime of PV panels proves competitive with the recycling route from a financial perspective.

14 SOLAR ENERGY↗

Produced Water and Waste Heat-aided Blowdown Water Treatment: Using Chemical and Energy Synergisms for Value Creation

The project objective was to develop a cooling blowdown water (BDW) treatment process utilizing produced water (PW) and low-grade heat to maximize water reuse and saleable by-product generation while reducing chemical and energy footprints of the treatment. The proposed treatment process consists of mixing, softening, organics and suspended solids removal, reverse osmosis (RO), thermal desalination, and brine electrolysis. BDW samples collected from a local coal-fired power plant and PW samples from two shale gas production wells were used in this study. Each treatment unit was first designed and tested to quantify its treatment efficiency, and its chemical and energy requirements. In addition, a process model was developed and model simulations were conducted based on the experimental results and literature data to optimize the treatment process. A techno-economic analysis was conducted to quantify chemical and energy savings as well as production of 10-lb brine as a saleable product. With the field-collected BDW and PW samples, mixing experiments determined a volumetric mixing ratio 10:1 (BDW:PW) resulted in the best performance of multivalent ions removal and largest chemical savings for softening. Softening of the BDW/PW mixtures using alkaline chemicals (Na 2 CO 3 and NaOH) achieved 95%-100% removal of scaling-forming cations (Ca, Mg, Fe, Ba, Sr) and 60% of silicon, and 10% of total organic carbon (TOC). The mixing and softening treatments yielded an effluent with total dissolved solids (TDS) concentration of 23 g/L. Activated carbon (AC) filtration removed TOC to a low level (< 3 mg/L) and further removed remaining scale-forming divalent metals and silica from the softened water. The AC filtration resulted in a slight reduction of TDS from 23 g/L to 20 g/L, leaving behind only mostly monovalent ions (i.e., sodium and chloride) in the filtered water. These pretreatments yielded a feed water that met the criteria of the downstream reverse osmosis (RO) to prevent membrane fouling. A cross-flow RO system was used to further concentrate the TDS of the AC effluent. Various factors including TDS, pH, and applied pressure were examined and optimal conditions were determined for the co-treatment process. An integrated process consisting of mixing, softening, AC filtration and RO was used to treat a continuous flow (0.25 – 1.2 L/min, or 0.07 – 0.32 gpm) and successfully generated RO permeate as product water (TDS < 0.5 g/L) for reuse in cooling operation, and a concentrate (TDS ~ 45 g/L) to be further treated in a thermal desalination unit. These flow rates meet the FOA’s criterion of 0.01 – 1 gpm. Overall, the co-treatment of BDW/PW allowed shorter ramp-up time compared to treatment of BDW alone. It resulted in 40% and 55% savings of Na 2 CO 3(s) and NaOH, respectively, compared to treating the BDW and PW individually for the same level of softening. The co-treatment also resulted in a 29% energy saving compared to treatment of BDW only for the level of TDS concentration. A thermal desalination system was designed using CFD simulations and manufactured in the WVU Innovation Hub for further treatment of the RO concentrate to generate 10-lb brine. The system has a design flow rate of 2 gpm and has been successfully tested. A bench-scale brine electrolysis system was developed for on-site generation of chlorine/hypochlorite (Cl 2 /OCl - ) and caustic soda (NaOH) as useful chemicals for the co-treatment process. Using salt solutions (0.5 M and 1 M), the system achieved faradaic efficiencies of 93%-97% and 70%-77% for caustic soda and chlorine/hypochlorite generation, respectively. An economic analysis showed that the electricity costs for on-site generation of these chemicals were significantly lower than the chemical prices offered by suppliers. An industrial-scale process model consisting of mixing, softening, AC filtration, RO, thermal desalination, and brine electrolysis was developed using the Aspen Plus V9 in conjunction with Aspen Custom Modeler V9. The model serves as a solvable Aspen Plus model and as basis to form the costing infrastructure. In addition, techno-economic analysis considering capital, operating, and transportation costs was conducted. An optimization solution showed that produced water for mixing is still advantageous in low quantities. The optimum solution approaches a leveled cost of water (LCW) of 2 $/m 3 which becomes cost competitive with nominal water treatment prices.

20 FOSSIL-FUELED POWER PLANTS↗

REPACT tool: A Screening Model for Repurposing Natural Gas Pipelines

Presentation on Reuse of Existing Pipelines for Adapted Carbon Dioxide Transport (REPACT) Tool for the January 2025 FECM interagency CO2 Transport topic team Meeting. The tool enables the user to determine whether a pipeline that was originally deployed for natural gas transport can be reused for carbon dioxide (CO2) transport.

carbon dioxide (CO2)↗

Sonic Wafering of III-V substrates for High Efficiency Cells: A path to <$0.50/W

This project developed and demonstrated Sonic Lift-off, a novel technology that enables the reuse of expensive semiconductor substrates used to manufacture high-efficiency solar cells. By using sound waves to precisely separate thin layers of material, the process significantly reduces manufacturing costs while maintaining the performance of advanced III–V solar cells. These solar cells are among the most efficient in the world and are used in space, aerospace, and emerging terrestrial applications. The results of this work show that substrate reuse can be achieved without degrading device performance, offering a pathway to more affordable, high-performance solar technologies. This advancement supports U.S. clean energy goals by enabling broader deployment of renewable energy systems and strengthening domestic manufacturing capabilities in advanced photovoltaics.

14 SOLAR ENERGY↗

Advancing Desalination and Treatment of Non-Traditional Source Water: The First 3.5 Years of the National Alliance for Water Innovation (NAWI)

The National Alliance for Water Innovation (NAWI) is the U.S. DOE's 5-year, $110M research Hub focused on desalination and water reuse. NAWI is organized into three Topic Areas in which projects are managed and coordinated: Materials and Manufacturing R&D (M&M), Process Innovation and Intensification R&D (PI&I), and Data, Modeling, and Analysis (DMA). In its first 3.5 years, NAWI has established the largest integrated DOE Innovation Hub (108 Research Consortium member organizations, 440 Alliance member organizations) anchored around its APRIME vision for lowering the cost and energy of desalination and water reuse. NAWI has selected 74 research projects to date, and several have reported major advances in desalination research and technology in leading scientific publications.

desalination↗

Emerging Trends in Biological Treatment of Wastewater From Unconventional Oil and Gas Extraction

Unconventional oil and gas exploration generates an enormous quantity of wastewater, commonly referred to as flowback and produced water (FPW). Limited freshwater resources and stringent disposal regulations have provided impetus for FPW reuse. Organic and inorganic compounds released from the shale/brine formation, microbial activity, and residual chemicals added during hydraulic fracturing bestow a unique as well as temporally varying chemical composition to this wastewater. Studies indicate that many of the compounds found in FPW are amenable to biological degradation, indicating biological treatment may be a viable option for FPW processing and reuse. This review discusses commonly characterized contaminants and current knowledge on their biodegradability, including the enzymes and organisms involved. Further, a perspective on recent novel hybrid biological treatments and application of knowledge gained from omics studies in improving these treatments is explored.

59 BASIC BIOLOGICAL SCIENCES↗

Durability of Disposable N95 Mask Material When Exposed to Improvised Ozone Gas Disinfection

The principle finding of this report is that both commercial and a novel material used for N95 mask filters can endure many cycles of disinfection by ozone gas (20 ppm for 30 minutes) without detectable degradation or loss of filtration efficiency. N95 masks and surgical masks (hereafter referred to as masks) typically use a filtration material fabricated from meltblown polypropylene. To achieve maximum filtration efficiency while maintaining a reasonable pressure drop, these nonwoven fabrics are also electrostatically charged (corona discharge is the most common method used), to maximize attraction and capture of aerosols and solid particulates. Under normal circumstances, the reuse of masks is generally discouraged, but in times of crisis has become a necessity, making disinfection after each use a necessity. To be acceptable, any disinfection procedure must cause minimal degradation to the performance of the filter material. Possible performance degradation mechanisms include mechanical damage, loss of electrostatic charge, or both. One of the most practical and direct ways to measure combined mechanical and electrostatic integrity, and the subsequent ability to reuse mask filter material, is by the direct measurement of filtration efficiency. In this paper, we report that small numbers of disinfection cycles at reasonable virucidal doses of ozone do not significantly degrade the filtration efficiency of meltblown polypropylene filter material. By comparison, laundering quickly results in a significant loss of filtration efficiency and requires subsequent recharging to restore the electrostatic charge and filtration efficiency. A common assumption among biomedical scientists that ozone is far too destructive for this application. However, these direct measurements show that mask materials, specifically the filtration material, can withstand dozens of ozone disinfection cycles without any measurable degradation of filtration efficiency, nor any visible discoloration or loss of fiber integrity. The data are clear: when subjected to a virucidal dose of ozone for a much longer duration than is required for viral inactivation, there was no degradation of N95 filtration efficiency. The specific dosages of ozone needed for ~99% viral inactivation are thought to be at least 10 ppm for up to 30 minutes based upon an extensive literature review, but to standardize our testing, we consider a dose of 20 ppm for 30 minutes to be a reasonable and conservatively high ozone disinfection cycle. Finally, the material tested in this study withstood dosages of up to 200 ppm for 90 minutes, or alternatively 20 ppm for up to 36 hours, without detectable degradation, and further testing suggests that up to 30 or more disinfection cycles (at 20 ppm for 30 minutes) would result in less than a 5% loss of filtration efficiency. This report does not address the effect of ozone cycling on other mask components, such as elastics.

60 APPLIED LIFE SCIENCES↗

DCDM1: Lessons Learned from the World's Most Energy Efficient Data Center

This presentation discusses the holistic approach to design the world's most energy-efficient data center, which is located at the U.S. Department of Energy National Renewable Energy Laboratory (NREL). This high-performance computing (HPC) data center has achieved a trailing twelve-month average power usage effectiveness (PUE) of 1.04 and features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. We provide details of the demonstrated PUE and energy reuse effectiveness (ERE) and lessons learned during four years of production operation. Recent efforts to dramatically reduce the water footprint will also be discussed. Johnson Controls partnered with NREL and Sandia National Laboratories to deploy a thermosyphon cooler (TSC) as a test bed at NREL's HPC data center that resulted in a 50% reduction in water usage during the first year of operation. The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device with an open cooling tower.

97 MATHEMATICS AND COMPUTING↗

Conductive Liquid Metal Vitrimer Composites for Reconfigurable and Recyclable Flexible Electronics

Liquid metal (LM) elastomer composites exhibit excellent functionality for stretchable electronics and wearables, but limited recycling and reuse pathways constrain their sustainable use. Here, to address these challenges amid growing concerns over electronic waste, a conductive LM–vitrimer composite is presented that enables recyclable and reconfigurable electronics. This soft and stretchable composite features uniformly distributed LM inclusions that enhance thermal conductivity by 6.53× and enable the formation of conductive traces with electrical self-healing, while the vitrimer provides structural restoration. The dynamic covalent bonds of the vitrimer matrix are leveraged for both reprocessing the composite and chemically recovering 94% of the LM. This liquid-state filler slightly reduces the vitrimer's stiffness to 2.63 MPa (≈20% lower), while maintaining its high stretchability (>135% strain) and thermal stability. It is further examined how ultrasonicated LM inclusions interact with the vitrimer matrix and demonstrate the composite's self-healing and recyclability through two distinct approaches: 1) thermomechanical reprocessing, which restores fragmented composites under heat and compression for circuit reconfiguration; and 2) chemical recycling, which recovers the embedded LM for reuse in fabricating new composites and redesigned circuitry. With the integration of recyclability and diverse functional capabilities, LM–vitrimer composites emerge as a promising material platform for sustainable, flexible electronics.

Han, Youngshang [Univ. of Washington, Seattle, WA ↗