Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioactivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Setting an optimal procedure for transferring intermediate radioactive effluents: contribution of laboratory experiments - 15234

The INB35 nuclear facility at the CEA Saclay center is in charge of collecting and treating radioactive effluents generated from site's research activities. The first step of the process consists of an evaporation. The concentrate is an IL radioactive suspension with high salt concentration and suspended matter content. Until the 1990's, the resulting effluents were bitumen coated and since 2012 they have been cemented. During the 1990's, concentrates were stored in 7 tanks, named MA50X with X from 1 to 7. With today's changes to safety regulations, the effluents must now be transferred before tank dismantling. According to the site records, the compositions of the liquid wastes MA501, MA502, MA503, MA504, MA506 and MA507 are similar. From 2013 to 2014, effluents contained in MA502, MA503, MA504 tanks have been transferred. Several difficulties have been encountered: - The tanks were historically different, especially manhole tank access - Since the 1990's, effluent composition has changed due to water evaporation. The salt concentration has increased and insoluble elements have formed a deposit in the bottom of the tanks resulting in high composition heterogeneity - In some tanks, a wall breeze-blade exists dividing the tank into two zones, which complicates the interventions. Major challenges have been met and will be described in the presentation. - To obtain an effluent which is as homogeneous as possible, the duration of mixing has been optimized. - To pump the liquid, it has been necessary to treat the effluent with nitric acid. This step has been optimized thanks to experiments in laboratory and hydrodynamic modelling. - A mobile workshop has been designed in order to perform the effluent transfer. It is set up directly above the tanks and can be moved from one tank to another on rails. Laboratory experiments have been carried out to characterize the suspension and sludge in order to understand its chemical behavior. - The treatment of the effluent has been studied in the laboratory and is now mastered. - The analytical strategy has been optimized. The close collaboration between the analytical laboratory and the dismantling project was a real advantage. Thanks to this, the duration of the last transfer on MA 504 was reduced by half, compared to the first operations. Transfer operations will be described and the differences and similarities between laboratory and in-situ observations will be pointed out. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ecological risk assessment software for radioactive waste management facilities - 15464

Environmental Risk Assessment (ERA) is a systematic process which can be used to identify, quantify and characterize the risk posed by contaminants and physical stressors in the environment on biological receptors, including human and non-human biota. Human receptors can be addressed through a Human Health Risk Assessment and non-human biota can be addressed through an Ecological Risk Assessment (EcoRA). In 2012 the Canadian Standards Association (CSA) issued a CSA standard N288.6 Environmental Risk Assessment at Class I Nuclear Facilities and Uranium Mines and Mills. The standard applies to radioactive waste management facilities, as well as nuclear power plants. The ERA can also be used retrospectively, to estimate the effect that a contaminant or stressor has already had on the environment; and can be used to assist in determining possible remedial or risk management options to return the quality of the affected environment to a predetermined state. While industry-standard tools for estimating radiological doses to humans are readily available, there is a need for a tool to implement the CSA N288.6 standard for Ecological Risk Assessment. To address this need, AMEC developed a computer code called -Assessment of Impact of Contaminants on Ecological Receptors (AICER)-. The code was developed to be consistent with the CSA standard N288.6, by assessing the impact of radiological contamination on non-human biota for normal operations. The code can also be used to screen for the potential effects of conventional contamination on the environment. In addition, the code is also applicable for abnormal events and accidents with the appropriate modification of some parameters used in the code. The AICER code was qualified in accordance with the requirements of the Canadian quality standard CSA N286.7 -Quality Assurance of Analytical, Scientific, and Design Computer Programs for Nuclear Power Plants-. The functionality of the code is illustrated with screen shots in the paper, following the introduction of the theoretical model for the dose calculation. An inter-comparison with RESRAD-BIOTA and ERICA Assessment tool at the conceptual level was conducted. In addition, the practical application of the code for the assessment of the impacts related to an existing radioactive waste management facility is provided. In particular, analysis was conducted to evaluate radiological doses to non-human biota resulting from a fire accident scenario involving an existing waste storage and processing facility. Analysis included all feasible waterborne and airborne exposure pathways. Doses were evaluated for a range of species representing valued ecological components at various trophic levels and compared with benchmark values for indicator species. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Issues Affecting the Assessment of Impacts of Disposal of Radioactive and Hazardous Waste - 18177

BIOPROTA is an international collaborative forum that seeks to address the key uncertainties in long term assessments of radionuclide and other contaminant releases into the environment arising from solid radioactive waste disposal. (see www.bioprota.org). Two workshops have been organized through the BIOPROTA forum to consider the non-radiological post-disposal impacts of radioactive waste disposal. In these workshops, it was noted that, ideally, the assessment of radionuclides and hazardous materials should be such that consistent assumptions and criteria are used in risk evaluation and that in cases where this is not possible, a clear understanding of the reasons why needs to be provided. Accordingly, a detailed review was organized through BIOPROTA to provide information to support development of a consensus on how to address this issue. The study suggests that there is a continuing need for some common measure of hazard that supports identification of risk management priorities for mixed hazardous waste. Without it, effective optimization of management of these mixed hazardous wastes will be restricted. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery of Buried Discrete Radioactive Objects by Channel-Specific Analysis of Gamma Scan Data - 19110

During radiological clean-up activities, gamma scan survey data collected from across an industrial site revealed spatially varying concentrations in radioactivity related to naturally occurring soil constituents or dissimilar fill materials that may have been placed at the site. A three-step process was developed to assess the data in order to identify radiation anomalies that most likely could represent small, buried discrete radioactive objects (ROs). The three-step process consists of: (1) define the radiological composition of the site isotopically, (2) spatially parse the data into more homogeneous subgroupings based on the site's radiological composition, and (3) perform analysis of the data subgroupings to identify statistical and spatial population outliers (i.e., radiation anomalies) that otherwise may be masked by the overall variation in the data. Using this process, locations containing buried low-specific activity ROs or higher activity ROs whose radiation is attenuated by soil can be identified and investigated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisit of Phase Separation of Borosilicate Glass for Vitrification of High Level Radioactive Waste - 19166

Phase separation of glasses for vitrification of high level radioactive waste has been experimentally studied to know uncertainty of the phase separation conditions; temperature and glass compositions as well as to propose possibility of recycling of heavy metals on a longer time scale. Our current results at 700 and 750 deg. C for ternary borosilicate glass system showed that the phase separation region at 700 deg. C spreads along with a direction of increasing Na{sub 2}O composition when compared with the data in literature. On the other hand, at the glass composition employed in the reprocessing plant in Japan, no segregation was observed. Concerning the application of phase separation phenomena, we had previously reported recovery of almost all elements from the vitrified borosilicate glass containing simulated fission products through phase separation of the borosilicate glass and this suggests that we could propose that after vitrification of high-level radioactive waste heavy metals may be retrieved as energy or materials resources when they are required to utilize on a longer time scale. From this standpoint, phase separation of lead borosilicate glass was also studied to seek economical and versatile recycling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of Novel Canadian Approaches for Decontamination of Solid Radioactive and Mixed Waste - 19476

The availability of decontamination-for-release technology options provide a path forward to economically decontaminate radioactive metallic waste and enable its disposal as clean scrap metal, to decontaminate tools/equipment for unrestricted refurbishment or reuse, and to carry out inspection of in-service components. Projects involving management of solid mixed waste pose complex technical challenges that require the development and application of novel decontamination processes. The objective of this paper is to present project case studies that provide an overview of Kinectrics' experience with the decontamination of solid radioactive and mixed waste. Novel approaches to decontamination, recent developments, key results and lessons learned will also be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of Energy Absorbing Materials for Radioactive Packaging

Most applications of honeycomb materials are for lightweight structural members. This area of honeycomb material behavior has been extensively researched. In packaging design, honeycomb materials are used for impact energy absorption. Data concerning the deformation of stainless steel honeycomb structures is not widely available. It is being proposed to use honeycomb stainless steel as an impact energy absorber in a new radioactive material shipping package. Honeycomb materials can be useful for energy absorption applications because the geometry causes the structure to have a constant compressive force during buckling. This Finite Element Analysis is used to predict the compressive buckling strength of various honeycomb structures in order to design an energy absorber for a specific package weight and geometry. The model simulates a drop test where a 50 pound plate lands flat on a honeycomb stainless steel structure from a height of 30 feet. Some actual drop tests have already been performed on real specimens. Most of the resulting deformations of these tests include the bottom of the honeycomb structure buckling while the rest of the structure was either slightly deformed or straight. The deformation of the simulated honeycomb specimen matched the deformation from the actual drop tests. This is one verification that the model is working properly. It is evident that after about 2.5% strain the strength is a relatively linear value, and eventually flattens out to about 875 psi. The crush strength measured from the actual drop tests for the same density honeycomb was just over 800 psi. This is further verification that the model is working correctly. The results gathered from the FEA model successfully mirror the results from a real drop test. The deformation looks realistic, and the compressive strength found is consistent with the empirically measured value. Future work for this model includes modeling different density honeycomb structures which have not been tested before. This will allow for optimization of honeycomb stainless steel use for impact absorption in radioactive material shipping packages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-destructive Material Characterization of Radioactive Waste Packages with QUANTOM{sup R} - 20130

During the last decades, the nuclear and non-nuclear industry has produced a considerable amount of low and intermediate level radioactive wastes. In many countries, it is foreseen to dispose of these waste packages safely in a final repository under strict waste acceptance requirements (e.g. the radiological and material characterization) defined by national licensing and supervisory authorities. The material characterization of waste packages can be performed on the basis of existing documentation or, if the documentation is insufficient, on further destructive or non-destructive analysis. Non-destructive methods are to be preferred to minimize radiation exposures of operating personnel as well as costs. We offer here an innovative non-destructive technology called QUANTOM{sup R} (Quantitative Analysis of Toxic and nontoxic Materials) based on prompt and delayed gamma neutron activation analysis (P and DGNAA). This technology is able to identify, quantify and thus verify the amount of hazardous and non-hazardous substances in 200-l radioactive drums, which is required for a final disposal characterization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement of Quantification in Non-Destructive Characterization of Radioactive Waste Packages -Introduction to the Ideas of a Currently Started Project - 20197

For the characterization of radioactive waste packages (e.g. 200-L drums) with inhomogeneous activity and density distributions preferably non-destructive methods like segmented gamma scanning and transmission measurements are applied. While the first is used for identification of the radioactive inventory, both are necessary for a reliable activity quantification. Although at nuclear facilities, segmented gamma scanner are state-of-the-art and are mostly equipped with a vertically moveable transmission source the combining of this data and further a-priori information improving accuracy in data estimation giving realistic, reliable and traceable uncertainty estimations are improvable. This challenge is tackled by a R and D project funded by the German Federal Ministry of Education and Research (BMBF). The boundary conditions for this project are (i) taking into account the typical instrumentation available at nuclear facilities, (ii) minimize the overall measurement time and (iii) combining data from emission and transmission measurements by Bayesian methods. For the R and D project, being still in its initial stage, the basic ideas, the data used for evaluation and the result of a preliminary investigation demonstrating the proof of principle are presented. Additionally, some first aspects on spatial resolution in emission and transmission measurements are addressed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEVELOPMENT OF A ROTARY MICROFILTER FOR RADIOACTIVE WASTE APPLICATIONS

The processing rate of Savannah River Site (SRS) high-level waste decontamination processes are limited by the flow rate of the solid-liquid separation. The baseline process, using a 0.1 micron cross-flow filter, produces {approx}0.02 gpm/sq. ft. of filtrate under expected operating conditions. Savannah River National Laboratory (SRNL) demonstrated significantly higher filter flux for actual waste samples using a small-scale rotary filter. With funding from the U. S. Department of Energy Office of Cleanup Technology, SRNL personnel are evaluating and developing the rotary microfilter for radioactive service at SRS. The authors improved the design for the disks and filter unit to make them suitable for high-level radioactive service. They procured two units using the new design, tested them with simulated SRS wastes, and evaluated the operation of the units. Work to date provides the following conclusions and program status: (1) The authors modified the design of the filter disks to remove epoxy and Ryton{reg_sign}. The new design includes welding both stainless steel and ceramic coated stainless steel filter media to a stainless steel support plate. The welded disks were tested in the full-scale unit. They showed good reliability and met filtrate quality requirements. (2) The authors modified the design of the unit, making installation and removal easier. The new design uses a modular, one-piece filter stack that is removed simply by disassembly of a flange on the upper (inlet) side of the filter housing. All seals and rotary unions are contained within the removable stack. (3) While it is extremely difficult to predict the life of the seal, the vendor representative indicates a minimum of one year in present service conditions is reasonable. Changing the seal face material from silicon-carbide to a graphite-impregnated silicon-carbide is expected to double the life of the seal. Replacement of the current seal with an air seal could increase the lifetime to 5 years and is undergoing testing in the current work. (4) The bottom bushing showed wear due to a misalignment during the manufacture of the filter tank. Replacing the graphite bushing with a more wear resistant material such as a carbide material will increase the lifetime of the bushing. This replacement requires a more wear resistant part or coating to prevent excessive wear of the shaft. The authors are currently conducting testing with the more wear resistant bushing. (5) The project team plans to use the rotary microfilter as a filter in advance of an ion exchange process under development for potential deployment in SRS waste tank risers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING AN ION EXCHANGE PROCESS FOR CESIUM REMOVAL FROM ALKALINE RADIOACTIVE WASTE SOLUTIONS

The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ADVANCES IN SE-79 ANALYSES ON SAVANNAH RIVER SITE RADIOACTIVE WASTE MATRICES

Waste cleanup efforts underway at the United States Department of Energy's (DOE) Savannah River Site (SRS) in South Carolina, as well as other DOE nuclear sites, have created a need to characterize {sup 79}Se in radioactive waste inventories. Successful analysis of {sup 79}Se in high activity waste matrices is challenging for a variety of reasons. As a result of these unique challenges, the successful quantification of {sup 79}Se in the types of matrices present at SRS requires an extremely efficient and selective separation of {sup 79}Se from high levels of interfering radionuclides. A robust {sup 79}Se radiochemical separation method has been developed at the Savannah River National Laboratory (SRNL) which is routinely capable of successfully purifying {sup 79}Se from a wide range of interfering radioactive species. In addition to a dramatic improvements in the Kd, ease, and reproducibility of the analysis, the laboratory time has been reduced from several days to only 6 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of Nevada Test Site Radioactive and Mixed Waste Disposal Operations

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office Environmental Management Program is responsible for carrying out the disposal of on-site and off-site generated low-level radioactive waste (LLW) and low-level radioactive mixed waste (MW) at the Nevada Test Site (NTS). Core elements of this mission are ensuring safe and cost-effective disposal while protecting workers, the public, and the environment. This paper focuses on the impacts of new policies, processes, and opportunities at the NTS related to LLW and MW. Covered topics include: the first year of direct funding for NTS waste disposal operations; zero tolerance policy for non-compliant packages; the suspension of mixed waste disposal; waste acceptance changes; DOE Consolidated Audit Program (DOECAP) auditing; the 92-Acre Area closure plan; new eligibility requirements for generators; and operational successes with unusual waste streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SPONTANEOUS CATALYTIC WET AIR OXIDATION DURING PRE-TREATMENT OF HIGH-LEVEL RADIOACTIVE WASTE SLUDGE

Savannah River Remediation, LLC (SRR) operates the Defense Waste Processing Facility for the U.S. Department of Energy at the Savannah River Site. This facility immobilizes high-level radioactive waste through vitrification following chemical pretreatment. Catalytic destruction of formate and oxalate ions to carbon dioxide has been observed during qualification testing of non-radioactive analog systems. Carbon dioxide production greatly exceeded hydrogen production, indicating the occurrence of a process other than the catalytic decomposition of formic acid. Statistical modeling was used to relate the new reaction chemistry to partial catalytic wet air oxidation of both formate and oxalate ions driven by the low concentrations of palladium, rhodium, and/or ruthenium in the waste. Variations in process conditions led to increases or decreases in the total oxidative destruction, as well as partially shifting the preferred species undergoing destruction from oxalate ion to formate ion.

08 HYDROGEN↗

Decision-making Framework to Support the End-of-Life Management of High-Activity Radioactive Sources

Sealed radioactive sources are used for an extremely wide range of purposes, including as radiation sources in various nuclear facilities, universities, hospitals, biomedical and industrial applications, as well as for geological prospecting and exploration. The proper management of these sealed radioactive sources once they have reached their end-of-life is still a global challenge. Very few field-tested Mobile Hot Cells (MHC) exist in the world to support the end-of-life management of disused high-activity radioactive sources. One of the critical challenges that a source recovery team encounters on each site is to find adequate space, and access to that space to complete the staging and recapture process with a MHC; this process is tedious, uncertain, and time-consuming. Therefore, it is essential to understand the planning and management of the MHC setup and takedown. Currently, there isn't an single capable planning tool that will provide an effective medium to plan, inform, educate, and communicate knowledge about the environment where the MHC will be deployed. We present a novel approach for the planning and management of the deployment of the MHC to several different sites that relies on technology. Furthermore, this planning tool will support collaboration, promote information sharing, and foster better decision making processes, resulting in a more efficient, and reliable setup and source recovery with the MHC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Radioactive {sup 125}I Seed Implantation Therapy of Symptomatic Retroperitoneal Lymph Node Metastases

Purpose: This study explored the clinical efficacy of CT-guided radioactive {sup 125}I seed implantation in treating patients with symptomatic retroperitoneal lymph node metastases. Methods: Twenty-five patients with pathologically confirmed malignant tumors received CT-guided radioactive {sup 125}I seed implantation to treat metastatic lymph nodes. The diameter of the metastatic lymph nodes ranged from 1.5 to 4.5 cm. Treatment planning system (TPS) was used to reconstruct the three-dimensional image of the tumor and then calculate the corresponding quantity and distribution of {sup 125}I seeds. Results: Follow-up period for this group of patients was 2–30 months, and median time was 16 months. Symptoms of refractory pain were significantly resolved postimplantation (P < 0.05), and Karnofsky score rose dramatically (P < 0.05). Most patients reported pain relief 2–5 days after treatment. Follow-up imaging studies were performed 2 months later, which revealed CR in 7 patients, PR in 13 patients, SD in 3 patients, and PD in 2 patients. The overall effective rate (CR + PR) was 80 %. Median survival time was 25.5 months. Seven patients died of recurrent tumor; 16 patients died of multiorgan failure or other metastases. Two patients survived after 30 months follow-up. Two patients reported localized skin erythema 1 week postimplantation, which disappeared after topical treatment. Conclusions: CT-guided radioactive {sup 125}I seed implantation, which showed good palliative pain relief with acceptable short-term effects, has proved in our study to be a new, safe, effective, and relatively uncomplicated treatment option for symptomatic retroperitoneal metastatic lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗