Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Direct-conversion flat-panel imager with avalanche gain: Feasibility investigation for HARP-AMFPI

The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rushing photoconductor (HARP) in which the charge undergoes avalanche multiplication. An active matrix of thin film transistors is used to read out the electronic image. The authors call the proposed imager HARP active matrix flat panel imager (HARP-AMFPI). The key advantages of HARP-AMFPI are its high spatial resolution, owing to the direct-conversion a-Se layer, and its programmable avalanche gain, which can be enabled during low dose fluoroscopy to overcome electronic noise and disabled during high dose radiography to prevent saturation of the detector elements. This article investigates key design considerations for HARP-AMFPI. The effects of electronic noise on the imaging performance of HARP-AMFPI were modeled theoretically and system parameters were optimized for radiography and fluoroscopy. The following imager properties were determined as a function of avalanche gain: (1) the spatial frequency dependent detective quantum efficiency; (2) fill factor; (3) dynamic range and linearity; and (4) gain nonuniformities resulting from electric field strength nonuniformities. The authors results showed that avalanche gains of 5 and 20 enable x-ray quantum noise limited performance throughout the entire exposure range in radiography and fluoroscopy, respectively. It was shown that HARP-AMFPI can provide the required gain while maintaining a 100% effective fill factor and a piecewise dynamic range over five orders of magnitude (10{sup -7}-10{sup -2} R/frame). The authors have also shown that imaging performance is not significantly affected by the following: electric field strength nonuniformities, avalanche noise for x-ray energies above 1 keV and direct interaction of x rays in the gain region. Thus, HARP-AMFPI is a promising flat-panel imager structure that enables high-resolution fully quantum noise limited x-ray imaging over a wide exposure range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of different computed radiography systems: Physical characterization and contrast detail analysis

Purpose: In this study, five different units based on three different technologies--traditional computed radiography (CR) units with granular phosphor and single-side reading, granular phosphor and dual-side reading, and columnar phosphor and line-scanning reading--are compared in terms of physical characterization and contrast detail analysis. Methods: The physical characterization of the five systems was obtained with the standard beam condition RQA5. Three of the units have been developed by FUJIFILM (FCR ST-VI, FCR ST-BD, and FCR Velocity U), one by Kodak (Direct View CR 975), and one by Agfa (DX-S). The quantitative comparison is based on the calculation of the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Noise investigation was also achieved by using a relative standard deviation analysis. Psychophysical characterization is assessed by performing a contrast detail analysis with an automatic reading of CDRAD images. Results: The most advanced units based on columnar phosphors provide MTF values in line or better than those from conventional CR systems. The greater thickness of the columnar phosphor improves the efficiency, allowing for enhanced noise properties. In fact, NPS values for standard CR systems are remarkably higher for all the investigated exposures and especially for frequencies up to 3.5 lp/mm. As a consequence, DQE values for the three units based on columnar phosphors and line-scanning reading, or granular phosphor and dual-side reading, are neatly better than those from conventional CR systems. Actually, DQE values of about 40% are easily achievable for all the investigated exposures. Conclusions: This study suggests that systems based on the dual-side reading or line-scanning reading with columnar phosphors provide a remarkable improvement when compared to conventional CR units and yield results in line with those obtained from most digital detectors for radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the structure of low-e substrates and consequences for IR transflection measurements

Spectral distortions caused by the electric field standing wave effect were investigated for two commonly used reflective substrates: low-emissivity glass and gold-coated glass. Our analytical calculations showed that spectral distortions may arise for both incoherent and coherent light sources when performing transflectance measurements. We experimentally confirmed our predictions using a commercial mid-infrared quantum cascade laser microscope and an interferometric infrared imaging system.

infrared spectroscopy↗

Magnifying absolute instruments for optically homogeneous regions

We propose a class of magnifying absolute optical instruments with a positive isotropic refractive index. They create magnified stigmatic images, either virtual or real, of optically homogeneous three-dimensional spatial regions within geometrical optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rates of exponential decay in systems of discrete energy levels by Stieltjes imaging

An isolated bound state coupled to a continuum shows an exponential decay of its survival probability. Rates of the exponential decay occurring due to the bound-continuum coupling can be recovered from discretized continuum (L{sup 2}) calculations using a computational technique known as Stieltjes-Chebyshev moment theory or Stieltjes imaging. At the same time, some genuinely discrete level systems, e.g., Bixon-Jortner model, also show an exponential (or approximately exponential) decay of the initially populated level before the onset of quantum revivals. Here, we demonstrate numerically that Stieltjes imaging can be used for calculation of the rates of the exponential decay in such discrete level systems. We apply the Stieltjes imaging technique to the approximately exponential decay of inner-valence vacancies in trans-butadiene in order to show that the breakdown of the molecular orbital picture of ionization in the inner valence region can be physically interpreted as an energy-forbidden Coster-Kronig transition.

74 ATOMIC AND MOLECULAR PHYSICS↗

Probing three-dimensional mesoscopic interfacial structures in a single view using multibeam X-ray coherent surface scattering and holography imaging

Abstract Visualizing surface-supported and buried planar mesoscale structures, such as nanoelectronics, ultrathin-film quantum dots, photovoltaics, and heterogeneous catalysts, often requires high-resolution X-ray imaging and scattering. Here, we discovered that multibeam scattering in grazing-incident reflection geometry is sensitive to three-dimensional (3D) structures in a single view, which is difficult in conventional scattering or imaging approaches. We developed a 3D finite-element-based multibeam-scattering analysis to decode the heterogeneous electric-field distribution and to faithfully reproduce the complex scattering and surface features. This approach further leads to the demonstration of hard-X-ray Lloyd’s mirror interference of scattering waves, resembling dark-field, high-contrast surface holography under the grazing-angle scattering conditions. A first-principles calculation of the single-view holographic images resolves the surface patterns’ 3D morphology with nanometer resolutions, which is critical for ultrafine nanocircuit metrology. The holographic method and simulations pave the way for single-shot structural characterization for visualizing irreversible and morphology-transforming physical and chemical processes in situ or operando .

47 OTHER INSTRUMENTATION↗

Evaluating the paleomagnetic potential of single zircon crystals using the Bishop Tuff

We report zircon crystals offer a unique combination of suitability for high-precision radiometric dating and high resistance to alteration. Paleomagnetic experiments on ancient zircons may potentially constrain the history of the earliest geodynamo, which would hold broad implications for the early Earth's interior and atmosphere. However, the ability of zircons to record accurately the geomagnetic field has not been demonstrated. Here we conduct thermal and alternating field (AF) paleointensity experiments on 767.1 thousand year old (ka) zircons from the Bishop Tuff, California. The rapid emplacement of these zircons in a well-characterized magnetic field provides a high-fidelity test of the zircons' intrinsic paleomagnetic recording accuracy. Successful dual heating experiments on eleven zircons measured using a superconducting quantum interference device (SQUID) microscope yield a mean paleointensity of (1σ; after excluding possible maghemite-bearing zircons), which is consistent with high-precision results from Bishop Tuff whole rock (). High-resolution quantum diamond magnetic (QDM) mapping, electron microscopy, and X-ray tomography indicate that the bulk of the remanent magnetization in Bishop Tuff zircons is carried by Fe oxides associated with apatite inclusions, which may be susceptible to destruction via metamorphism and aqueous alteration in older zircons. As such, while zircons can reliably record the geomagnetic field, robust zircon-derived paleomagnetic results require careful characterization of the ferromagnetic carrier and demonstration of their occurrence in primary inclusions. We further conclude that a combination of quantum diamond magnetometry and high-resolution imaging can provide detailed, direct characterization of the ferromagnetic mineralogy of geological samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Quality Typhoon Cloud Image Restoration by Combining Genetic Algorithm with Contourlet Transform

An efficient typhoon cloud image restoration algorithm is proposed. Having implemented contourlet transform to a typhoon cloud image, noise is reduced in the high sub-bands. Weight median value filter is used to reduce the noise in the contourlet domain. Inverse contourlet transform is done to obtain the de-noising image. In order to enhance the global contrast of the typhoon cloud image, in-complete Beta transform (IBT) is used to determine non-linear gray transform curve so as to enhance global contrast for the de-noising typhoon cloud image. Genetic algorithm is used to obtain the optimal gray transform curve. Information entropy is used as the fitness function of the genetic algorithm. Experimental results show that the new algorithm is able to well enhance the global for the typhoon cloud image while well reducing the noises in the typhoon cloud image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of defect-free GaSb/GaAs(001) quantum dots grown on the Sb-terminated (2 × 8) surface

Multilayer and single layer GaSb/GaAs(001) quantum dot structures were grown on an Sb-terminated (2 × 8) surface reconstruction and compared to those grown on an As-terminated (2 × 4) surface reconstruction. Uncapped quantum dots grown on the (2 × 8) surface were approximately 25% smaller in diameter and had a larger width/height aspect ratio. Quantum dots grown on both surfaces were defect free at the quantum dot/spacer layer interface. The dots did not appear to be fully compact when imaged by transmission electron microscopy, which may be due to dissolution and/or quantum ring formation. The quantum dot photoluminescence peak for dots grown on the (2 × 8) surface was brighter but at the same energy as that of dots grown on the (2 × 4) surface. This was likely the result of a higher areal density of dots on the (2 × 8) surface and a lower tendency for them to intermix during capping, resulting in dots of similar size for both samples after capping. Quantum dots grown on the (2 × 8) surface also displayed greater morphological stability when quenched in the absence of Sb.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlated Nanoscale Analysis of the Emission from Wurtzite versus Zincblende (In,Ga)As/GaAs Nanowire Core–Shell Quantum Wells

Although the properties of wurtzite GaAs have been extensively researched during the past decade, little is known about the influence of the crystal polytype on ternary (In,Ga)As quantum well structures. We address this concern with a unique combination of correlated, spatially resolved measurement techniques on core–shell nanowires that contain extended segments of both the zincblende and wurtzite polytypes. Cathodoluminescence hyperspectral imaging reveals a blue-shift of the quantum well emission energy by 75 ± 15 meV in the wurtzite polytype segment. Nanoprobe X-ray diffraction and atom probe tomography enable k·p calculations for the specific sample geometry to reveal two comparable contributions to this shift. First, there is a 30% drop in In mole fraction going from the zincblende to the wurtzite segment. Second, the quantum well is under compressive strain, which has a much stronger impact on the hole ground state in the wurtzite than in the zincblende segment. Our findings illustrate the role of the crystal structure in tuning the emission of (In,Ga)As quantum wells and pave the way to exploit the possibilities of three-dimensional band gap engineering in core–shell nanowire heterostructures. At the same time, we have demonstrated an advanced characterization toolkit for the investigation of semiconductor nanostructures.

(In,Ga)As quantum well↗

4-wave mixing for phase-matching free nonlinear optics in quantum cascade structures : LDRD 08-0346 final report.

Optical nonlinearities and quantum coherences have the potential to enable efficient, high-temperature generation of coherent THz radiation. This LDRD proposal involves the exploration of the underlying physics using intersubband transitions in a quantum cascade structure. Success in the device physics aspect will give Sandia the state-of-the-art technology for high-temperature THz quantum cascade lasers. These lasers are useful for imaging and spectroscopy in medicine and national defense. Success may have other far-reaching consequences. Results from the in-depth study of coherences, dephasing and dynamics will eventually impact the fields of quantum computing, optical communication and cryptology, especially if we are successful in demonstrating entangled photons or slow light. An even farther reaching development is if we can show that the QC nanostructure, with its discrete atom-like intersubband resonances, can replace the atom in quantum optics experiments. Having such an 'artificial atom' will greatly improve flexibility and preciseness in experiments, thereby enhancing the discovery of new physics. This is because we will no longer be constrained by what natural can provide. Rather, one will be able to tailor transition energies and optical matrix elements to enhance the physics of interest. This report summarizes a 3-year LDRD program at Sandia National Laboratories exploring optical nonlinearities in intersubband devices. Experimental and theoretical investigations were made to develop a fundamental understanding of light-matter interaction in a semiconductor system and to explore how this understanding can be used to develop mid-IR to THz emitters and nonclassical light sources.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Atomic Resolution Cryogenic 4D-STEM Imaging via Robust Distortion Correction

Cryogenic four-dimensional scanning transmission electron microscopy (4D-STEM) imaging is a useful technique for studying quantum materials and their interfaces by simultaneously probing charge, lattice, spin, and chemistry on the atomic scale with the sample held at temperatures ranging from room to cryogenic. However, its applications are currently limited by the instabilities of cryo-stages and electronics. To overcome this challenge, we develop an algorithm to effectively correct the complex distortions present in atomic resolution cryogenic 4D-STEM data sets. This method uses nonrigid registration to identify localized distortions in a 4D-STEM and relate them to an undistorted experimental STEM image, followed by a series of affine transformations for distortion corrections. This method allows a minimum loss of information in both reciprocal and real spaces, enabling the reconstruction of sample information from 4D-STEM data sets. This method is computationally cheap, fast, and applicable for on-the-fly data analysis in future in situ cryogenic 4D-STEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

A grazing incidence x-ray streak camera for ultrafast, single-shot measurements

An ultrafast x-ray streak camera has been realized using a grazing incidence reflection photocathode. X-rays are incident on a gold photocathode at a grazing angle of 20 degree and photoemitted electrons are focused by a large aperture magnetic solenoid lens. The streak camera has high quantum efficiency, 600fs temporal resolution, and 6mm imaging length in the spectral direction. Its single shot capability eliminates temporal smearing due to sweep jitter, and allows recording of the ultrafast dynamics of samples that undergo non-reversible changes.

36 MATERIALS SCIENCE↗

Modified Method for Reconstructing the Image from Projections in Magnetic Resonance Tomography

A method for reconstructing the image from projections in magnetic resonance tomography using an excitation pulse with a linear frequency modulation has been considered. The shape of the spin echo envelope coincides with the projection of the spin density onto the direction of the axis along which the magnetic field gradient is applied. The spin echo excitation by a sinc pulse and a pulse with a linear frequency modulation has been simulated. The former pulse excites the required cross section of a 3D object, while the latter pulse has made it possible to form the spin echo envelope, which coincides in shape with the projection of the spin density of nuclei onto the direction of the gradient. The set of the projections onto different directions of the gradient has made it possible to reconstruct the 2D image of a section.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reflective ghost imaging through turbulence

Recent work has indicated that ghost imaging may have applications in standoff sensing. However, most theoretical work has addressed transmission-based ghost imaging. To be a viable remote-sensing system, the ghost imager needs to image rough-surfaced targets in reflection through long, turbulent optical paths. We develop, within a Gaussian-state framework, expressions for the spatial resolution, image contrast, and signal-to-noise ratio of such a system. We consider rough-surfaced targets that create fully developed speckle in their returns and Kolmogorov-spectrum turbulence that is uniformly distributed along all propagation paths. We address both classical and nonclassical optical sources, as well as a computational ghost imager.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗