Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

Normetex Pump Alternatives Study

A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying resistances to ionizing radiation - aromatic polymers such as polyimide Vespel (TM) and the elastomer EPDM (ethylene propylene diene monomer) have been found to be more resistant to degradation in tritium than other polymers. This report presents information to help select replacement pumps for Normetex pumps in tritium systems. Several pumps being considered as Normetex replacement pumps are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Biodiversity and Stoichiometric Plasticity Increase Pico‐Phytoplankton Contributions to Marine Net Primary Productivity and the Biological Pump

Earth System Models generally predict increasing upper ocean stratification from 21st century warming, which will cause a decrease in the vertical nutrient flux forcing declines in marine net primary productivity (NPP) and carbon export. Recent advances in quantifying marine ecosystem carbon to nutrient stoichiometry have identified large latitudinal and biome variability, with low-latitude oligotrophic systems harboring pico-sized phytoplankton exhibiting large phosphorus to carbon cellular plasticity. The climate forced changes in nutrient flux stoichiometry and phytoplankton community composition are thus likely to alter the ocean's biogeochemical response and feedback with the carbon-climate system. We have added three pico-phytoplankton functional types within the Biogeochemical Elemental Cycling component of the Community Earth System Model while incorporating variable cellular phosphorus to carbon stoichiometry for all represented phytoplankton types. The model simulates Prochlorococcus and Synechococcus populations that dominate the productivity and sinking carbon export of the tropical and subtropical ocean, and pico-eukaryote populations that contribute significantly to productivity and export within the subtropical to mid-latitude transition zone, with the western subtropical regions of each basin supporting the most P-poor stoichiometries. Subtropical gyre recirculation regions along the poleward flanks of surface western boundary currents are identified as regional hotspots of enhanced carbon export exhibiting C-rich/P-poor stoichiometry, preferentially inhabited by pico-eukaryotes and diatoms. Collectively, pico-phytoplankton contribute ∼58% of global NPP and ∼46% of global particulate organic carbon export below 100 m through direct and ecosystem processing pathways. Biodiversity and cellular nutrient plasticity in marine pico-phytoplankton combine to increase their contributions to ocean productivity and the biological carbon pump.

Environmental Sciences & Ecology↗

High power pumped mid-IR wavelength systems using nonlinear frequency mixing (NFM) devices

Laser diode pumped mid-IR wavelength systems include at least one high power, near-IR wavelength, injection and/or sources wherein one or both of such sources may be tunable providing a pump wave output beam to a quasi-phase matched (QPM) nonlinear frequency mixing (NFM) device. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Wavelength tuning of at least one of the sources advantageously provides the ability for optimizing pump or injection wavelengths to match the QPM properties of the NFM device enabling a broad range of mid-IR wavelength selectivity. Also, pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

Ecosystem-Level Biomimicry for the Built Environment: Adopting Systems Ecology Principles for the Control of Heterogeneous Energy Systems

This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.

biomimicry↗

Field Evaluation of Advances in Energy-Efficiency Practices for Manufactured Homes

Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductless mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Southern Energy Homes, First DOE Zero Energy Ready Manufactured Home, Russellville, Alabama

Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes.The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductless mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗

Prediction of a propellant tank pressure history using state space methods

An analysis of the time response of a propellant supply system operating in the blowdown mode is presented. The supply system is part of a pump-fed propulsion system intended for use on interplanetary spacecraft. As such, the supply system must provide the pump with propellant at sufficient pressure to avoid pump cavitation. The system, consisting of the tank, the liquid propellant, the pressurant gas and propellant vapor mixture, and a film layer separating the liquid and vapor phases, is analyzed using the principles of mass and energy conservation. The resulting set of ordinary, coupled, nonlinear differential equations for the thermodynamic state variables is integrated as an initial value problem. The resulting histories of total pressure, propellant vapor pressure, propellant liquid temperature, film layer temperature, propellant vapor/pressurant gas temperature, propellant vapor mass, and propellant liquid mass enable the calculation of the net positive suction head available at the pump which determines the viability of the pump-fed system concept when operated in the blowdown mode.

Estey, P. N.↗

International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

Morton, Richard D.↗

Status of DOE and AID stand-alone photovoltaic system field tests

The NASA Lewis Research Center (LeRC) is managing stand-alone photovoltaic (PV) system projects sponsored by the U.S. Department of Energy (DOE) and the U.S. Agency for International Development (AID). The DOE project includes village PV power demonstration projects in Gabon (four sites) and the Marshall Islands, and PV-powered vaccine refrigerator systems in six countries. The AID project includes a large village power system, a farmhouse system and two water pumping-irrigation systems in Tunisia, a water pumping/grain grinding system in Upper Volta, five medical clinic systems in four countries, PV-powered vaccine refrigerator systems in 18 countries and a PV-powered remote earth station in Indonesia. This paper reviews these PV projects and summarizes significant findings to date.

Bifano, W. J.↗

Thermal management in space

Thermal management for space-based and lunar- or asteroid-based power generating systems is discussed. Heat pipes, pump loop systems, and advanced radiator concepts are addressed.

Hertzberg, Abraham↗

Performance Evaluation of Electrochem's PEM Fuel Cell Power Plant for NASA's 2nd Generation Reusable Launch Vehicle

NASA's Next Generation Launch Technology (NGLT) program is being developed to meet national needs for civil and commercial space access with goals of reducing the launch costs, increasing the reliability, and reducing the maintenance and operating costs. To this end, NASA is considering an all- electric capability for NGLT vehicles requiring advanced electrical power generation technology at a nominal 20 kW level with peak power capabilities six times the nominal power. The proton exchange membrane (PEM) fuel cell has been identified as a viable candidate to supply this electrical power; however, several technology aspects need to be assessed. Electrochem, Inc., under contract to NASA, has developed a breadboard power generator to address these technical issues with the goal of maximizing the system reliability while minimizing the cost and system complexity. This breadboard generator operates with dry hydrogen and oxygen gas using eductors to recirculate the gases eliminating gas humidification and blowers from the system. Except for a coolant pump, the system design incorporates passive components allowing the fuel cell to readily follow a duty cycle profile and that may operate at high 6:1 peak power levels for 30 second durations. Performance data of the fuel cell stack along with system performance is presented to highlight the benefits of the fuel cell stack design and system design for NGLT vehicles.

Kimble, Michael C.↗

Impact of Fluid Flow Pressure drop on Temperature of Components Controlled by Mechanically Pumped Fluid Loop Thermal Control System

In a typical thermal control system that employs a mechanically pumped fluid loop to control component temperatures, fluid flow pressure drop is minimized to ensure that adequate fluid flow can be provided by the pump. Engineers often are overly concerned about violating a maximum pressure drop, almost treating it as a “wall” that should not be crossed. The true “wall” is the control of the temperatures of the components served by the loop to ensure that their temperatures do not violate their allowed limits. As a case study, for assessing this “constraint,” sensitivity analyses were undertaken to understand if this is truly a major constraint, and to assess the impact of pressure drop exceedance on the controlled components’ temperatures. The flow impedance is varied as a parameter to understand how it affects the controlled components’ temperatures. One key finding was that the temperatures of the controlled components is relatively insensitive to the flow impedance increases. This finding is obviously most relevant to this particular case study; however, this also provides the process and guidance for assessing the performance of other pump/loop combinations in terms of their sensitivity to pressure drop impedances.

Mastropietro, Arthur J.↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.

Polzin, K. A.↗