Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A novel shallow bore ground heat exchanger for ground source heat pump applications—Model development and validation

A novel ground heat exchanger design, the Underground Thermal Battery (UTB), was proposed as a low-cost alternative to the conventional vertical bore ground heat exchanger (VBGHE) for the application of ground source heat pumps (GSHPs). The UTB is designed to be installed in a shallow borehole (less than 6 m deep) and thus could cost much less than the conventional VBGHE, which usually is installed in vertical bores 60 m deep. By utilizing natural convection of water and phase change materials, the UTB tempers its temperature change in response to thermal loads, which helps improve the efficiency of GSHPs. A one-dimensional (1D) model of the UTB has been developed and validated with the measured performance data of a small-scale UTB, as well as the simulation results of a more detailed three dimensional (3D) numerical model, which accounts for both heat transfer and fluid dynamics in the UTB. Further, this 1D model is computationally much more efficient than the 3D model and thus can simulate the annual performance of the UTB with acceptable computation time. The 1D model has been used to evaluate the performance of the UTB so that it can be compared with the conventional VBGHE.

42 ENGINEERING↗

The Role of Fuels in Transforming Energy End-Use in Buildings and Industrial Processes

This book examines what role fuels have in the transformation of end-use in buildings and industrial processes. Energy efficient technologies are necessary to lower the carbon footprint for a transition towards clean energy in a sustainable manner. Efficient utilization of primary energy resources including renewables to support the current and future energy needs while targeting grid resiliency, energy and environmental security, at an affordable cost is of significant value. Analysis of configurations consisting of heat pumps, fuel driven thermal providers and power systems is presented. Sensitivity of electrical grid's carbon intensity towards carbon footprint in comparison with fuel driven technologies is necessary to recognize the true value proposition of currently available energy solutions for different end consumers. Similarly, the role of low carbon, zero carbon, and carbon negative fuels such as power to gas, power to liquid, hydrogen, biogas, etc. in conjunction with polygeneration technologies are discussed. Transformation of the primary energy resources from conventional fossil fuels to renewable fuels or electricity will have a significant impact on the overall carbon footprint of various end use sectors, including buildings. Hence, this book also examines two different scenarios focused on sensitivity of the pace of decarbonization of electrical grid and fuel supply on operational energy related carbon emissions.

Cheekatamarla, Praveen↗

Effective spin-mixing conductance of topological-insulator/ferromagnet and heavy-metal/ferromagnet spin-orbit-coupled interfaces: A first-principles Floquet-nonequilibrium Green function approach

The spin-mixing conductance (SMC) is a key quantity determining efficiency of spin transport across interfaces. Thus, knowledge of its precise value is required for accurate measurement of parameters quantifying numerous effects in spintronics, such as spin-orbit torque, spin Hall magnetoresistance, spin Hall effect, and spin pumping. However, the standard expression for SMC, provided by the scattering theory in terms of the reflection probability amplitudes, is inapplicable when strong spin-orbit coupling (SOC) is present directly at the interface. This is the precisely the case of topological-insulator/ferromagnet and heavy-metal/ferromagnet interfaces of great contemporary interest. We introduce an approach where first-principles Hamiltonian of these interfaces, obtained from noncollinear density functional theory (ncDFT) calculations, is combined with charge-conserving Floquet-nonequilibrium-Green-function formalism to compute directly the pumped spin current $I^{S_z}_L$ into semi-infinite left lead of two-terminal heterostructures Cu/X/Co/Cu or Y/Co/Cu—where X = Bi 2 Se 3 and Y = Pt or W—due to microwave-driven steadily precessing magnetization of the Co layer. This allows us to extract an effective SMC as a prefactor in $I^{S_z}_L$ versus precession cone angle θ dependence, as long as it remains the same, $I^{S_z}$ ∝ sin 2 θ , as in the case where SOC is absent. By comparing calculations where SOC in switched off versus switched on in ncDFT calculations, we find that SOC consistently reduces the pumped spin current and therefore the effective SMC.

36 MATERIALS SCIENCE↗

Exploring Decarbonization and Clean Energy Pathways for Disadvantaged Communities in California

California has a state-wide goal of carbon neutrality by 2045. Decarbonization for disadvantaged communities (DACs) poses extra challenges due to financial, informational, language, and other barriers. This paper presents the methodology, results, and analysis of energy efficiency measures (EEMs) to save energy, reduce CO 2 emission, and promote clean energy access at the district scale for two DACs in Fresno, California. The methods are broadly applicable to other neighborhoods across the U.S. 22 EEMs were identified and modelled for all residential buildings in the two DACs both individually and as packages. Results show that for energy and CO 2 reduction purposes, the top performing EEM package can decrease energy use and CO 2 emissions by an average of 60%. For electrification, heat pump water heaters are a viable solution, coupled with air source or mini-split heat pumps. Replacing gasoline vehicles with electric vehicles is another important measure in electrification and reducing GHG emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Controlled Assembly of Upconverting Nanoparticles for Low-Threshold Microlasers and Their Imaging in Scattering Media

Micron-sized lasers fabricated from upconverting nanoparticles (UCNP) coupled to whispering gallery mode (WGM) microresonators can exhibit continuous-wave anti-Stokes lasing useful for tracking cells, environmental sensing, and coherent stimulation of biological activity. The integration of these microlasers into organisms and microelectronics requires even smaller diameters, however, which raises threshold pump powers beyond practical limits for biological applications. To meet the need for low lasing thresholds and high fidelity fabrication methods, we use correlative optical and electron microscopy to uncover the nanoparticle assembly process and structural factors that determine efficient upconverted lasing. We show that 5 μm microspheres with controlled submonolayer UCNP coatings exhibit, on average, 25-fold lower laser thresholds (1.7 ± 0.7 kW/cm 2 ) compared to the mean values of the lowest threshold UCNP lasers, and variability is reduced 30-fold. WGMs are observed in the upconversion spectra for TiO 2 -coated microspheres as small as 3 μm, a size at which optical losses had previously prevented such observations. Finally, we demonstrate that the WGM signatures of these upconverting microlasers can be imaged and distinguished through tissue-mimicking phantoms. These advances will enable the fabrication of more efficient upconverting lasers for imaging, sensing, and actuation in optically complex environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ice-slurry production for solar-ice systems using supercooling with an in-stream crystallizer

Using ice slurry produced from supercooled water with an in-stream crystallizer opens a new path for solarice systems, increasing efficiency and reducing investment cost compared to ice-on-coil systems. Power needs are decoupled from the stored energy since the heat exchangers are not evenly distributed in the ice storage vessel but directly placed as the heat pump evaporator, which depends on the heat pump capacity and not on the ice storage volume. The novel ice storage design can serve as a heat source for a heat pump, where its evaporator is used to supercool water below 0 °C, or for refrigeration. The supercooled water at a temperature around −2 °C, maintained in a meta-stable liquid state, is triggered to nucleate in an in-stream crystallizer. The current design of the ice crystallizer allows for continuous operation of the system and scalability. Experimental results obtained with a gasketed plate heat exchanger used to supercool water and an in-stream crystallizer operated at a power of up to 6.5 kW are presented.

Thamm, Ann-Katrin↗

Flue-Gas Desulfurization Effluent Management using an Innovative Low-Energy Biosorpotion Treatment System to Remove Key Contaminants

Among the most critical water contaminants of concern affecting wide geographical regions and a number of industries and natural systems is selenium. Selenium found in surface, ground and wastewater in originates from natural sources, as well as industrial sources such as petroleum refineries, electronics manufacturing, pesticides, and coal power plants and mining also contribute to selenium contamination in water in the US. At high concentrations, selenium is toxic to human and wildlife. There are a number of technologies that have been used to treat selenium and other similar contaminants in water. Biological treatment of selenium has been used in the past to reduce soluble SeVI and/or SeIV to insoluble Se0, which is then filtered in the same vessel. The insoluble selenium (Se0) is then backwashed from the system and solids are separated for subsequent disposal, if they meet the leaching and water content criteria. In order to promote biological reduction to insoluble Se0, heating of bioreactor is needed in some applications, and excess food source (electron donor) is added so that all selenium can be filtered. An additional disadvantage of these systems is the significant amount of water lost due to extensive and frequent backwash and rinse cycles. When comparing the advantages and energy requirements of the various treatment technologies, RO membrane filtration immediately stands out due to the excessive energy expenditure needed to pump water across the membrane although RO is an effective way to remove selenium. In addition, RO requires extensive pretreatment, such as MF membrane, and frequent maintenance, rendering it an expensive option that may be out of reach for certain applications. In fact, although the performance was good during the pilot testing by the NSMP Working Group for treatment naturally occurring selenium in the surface water, the high electricity requirements and significant reject water stream made it an infeasible alternative. While conventional ion exchange maybe an effective treatment option, it requires frequent regeneration of the resin when applied to highly contaminated water, which leads to several tons of contaminant-laden, high-salinity brine that needs to be disposed off-site each day. One of the water systems in the west coast currently uses ion exchange for selenium treatment and has been trucking selenium laden hazardous brine waste weekly in the last several years. Pneumatic pumping and rinse water pumping required for ion exchange also increase the energy usage. In comparison, adsorption process is a passive treatment system where contaminated water comes in contact with an adsorption media in a vessel. Typically, there is no mixing, backwash, or recycle pumping required, thus significantly reducing the energy usage. A passive single-use adsorption system does not require backwash, thereby generating small amount of process waste, and producing the highest water yield among the alternatives. The energy and water efficiencies, and applicability for SeVI and SeIV are summarized in Table 1. Despite these benefits though, adsorption typically does not work for the most oxidized form of selenium (SeVI). The innovative biosorption process integrates both process to increase the treatment efficiency while minimizing energy, chemical, and time required to treat both SeVI and SeIV. Additional advantages include simple partial biological reduction with reduced on-site waste generation, which lead to water and electricity savings, and less operational need compared to biological treatment alone. This makes biosorption especially suitable for remote areas, where liquid backwash and brine disposal may be cost prohibitive or infeasible.

20 FOSSIL-FUELED POWER PLANTS↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vadose Zone Soil Flushing for Chromium Remediation: A Laboratory Investigation to Support Field‐scale Application

Cr(VI) flushing from the vadose zone to the groundwater (with subsequent Cr(VI) removal in groundwater by pump-and-treat system) is a promising remedial technique that has recently been used at field scale. This laboratory study was conducted to provide the technical basis to design a field soil flushing strategy. The objectives were to (1) quantify the relationship between sediment Cr(VI) and Cr(III) mass and release rates and subsequent Cr(VI) leaching; (2) investigate different methodologies to maximize Cr(VI) leaching, and (3) investigate methods to minimize leaching of remaining residual Cr. Characterization of Cr-contaminated sediments (Hanford Site, WA) exhibited Cr(VI) showed that leach rates that were correlated to different Cr surface phases. Sediments with low leachable Cr(VI) (<2 μg/g) leached Cr rapidly, so slow infiltration of water in a single pulse was sufficient to leach most Cr. In contrast, sediments with high Cr (2 to 200 μg/g) released some Cr(VI) quickly but 10 to 50% Cr(VI) slowly (tens to hundreds of hours). Efficient unsaturated leaching of these sediments required a different infiltration strategy that includes: multiple slow leach pulses with time between flushing cycles; the use of a surfactant to increase Cr leaching from low-permeability zones, and the use of a reductant (Na-dithionite or Ca-polysulfide) in the final leach water was highly effective at decreasing residual Cr leaching. This study clearly demonstrated that the methodology of basing laboratory Cr flushing on parameters such as Cr release mass and rates could be used to improve the efficiency of soil flushing at field scale.

Accelerated Cr Flushing↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stimulated emission tomography for efficient characterization of spatial entanglement

Stimulated-emission tomography (SET) is an excellent tool for characterizing the process of spontaneous parametric down conversion (SPDC), which is commonly used to create pairs of entangled photons for use in quantum information protocols. The use of stimulated emission increases the average number of detected photons by several orders of magnitude compared to the spontaneous process. In a SET measurement, the parametric down conversion is seeded by an intense signal field prepared with specified mode properties rather than by broadband multimodal vacuum fluctuations, as is the case for the spontaneous process. The SET process generates an intense idler field in a mode that is the complex conjugate to the signal mode. In this work we use SET to estimate the joint spatial mode distribution (JSMD) in the Laguerre-Gaussian (LG) basis of the two photons of an entangled photon pair. The pair is produced by parametric down conversion in a beta barium borate (BBO) crystal with type-II phase matching pumped at a wavelength of 405 nm along with a 780 nm seed signal beam prepared in a variety of LG modes to generate an 842 nm idler beam of which the spatial mode distribution is measured. We observe strong idler production and good agreement with the theoretical prediction of its spatial mode distribution. Our experimental procedure should enable the efficient determination of the photon-pair wavefunctions produced by low-brightness SPDC sources and the characterization of high-dimensional entangled-photon pairs. Published by the American Physical Society 2024

Xu, Yang (ORCID:0009000954547320)↗

HTS Dipole Magnet With Mechanical Energy Transfer in the Magnetic Field

Several high-temperature superconducting (HTS) model magnets for particle accelerators were designed and successfully tested at Fermilab. Some worked in a persistent current mode by continuously generating magnetic fields in the iron-dominated magnet gap. This paper investigated a novel HTS dipole magnet concept with a mechanical energy transfer in the magnetic field. To pump the energy in the superconducting HTS dipole magnet, a detachable magnetizer was used. The HTS dipole magnet was built and successfully tested at a liquid nitrogen temperature. We discuss the magnet design, test results, the proposed approach limits, and efficiency.

43 PARTICLE ACCELERATORS↗

Independent Review of Groundwater Remediation Strategy for Hexavalent Chromium and RDX Groundwater Plumes at Los Alamos National Laboratory (Rev. 1)

Site operations at the Los Alamos National Laboratory (LANL) resulted in the release of oxidized chromium, Cr(VI), into Sandia Canyon from cooling tower effluent from 1956 until 1972. The chromium traveled with the surface water approximately 3 miles downstream before migrating below ground surface. Chromium concentrations exceed 50 μg/L in the upper portion of the aquifer. Another LANL groundwater plume of concern is associated with RDX (Royal Demolition Explosives, 1,3,5-trinitro-1,3,5-triazine). Between 1951 and 1996, RDX was released to the mesa-top facilities' process water outfall, adjacent and underlying soils, and alluvial sediments, along with surface water in Cañon de Valle. Between 2000 and 2010, two remedial actions were deployed, removing much of the near-surface RDX, however, recharge due to precipitation has transported RDX into the perched-intermediate zone and into the regional aquifer. The report documents an independent technical review by scientists from the Department of Energy (DOE) Network of National Laboratories for Environmental Management and Stewardship (NNLEMS) to provide recommendations for potential near term actions to address and optimize remediation for both the Cr(VI) and RDX plumes. The proposed near-term remedial actions include design of pump and treat systems for Cr(VI) and monitoring and study for natural attenuation for RDX. The review assesses existing data, conceptual and numerical modeling, and it recommends a technical integration process to support identifying and implementing strategic, effective and efficient remedies. The DOE Environmental Management Los Alamos Field Office (EM-LA) and their cleanup contractor Newport News Nuclear-BWTX, LLC Los Alamos (N3B) provided the information required for the review. Interviews were also conducted with regulators to obtain the full spectrum of technical, regulatory and scientific perspectives. The independent review team was impressed by the capabilities, experiences, innovativeness, and insightfulness of the technical representatives from both the regulator, the New Mexico Environment Department (NMED) and N3B. Incorporation of vadose zone flow pathways in the conceptual site model (CSM) and configuring the numerical modeling for the site was generally state-of-the-practice (or better). This could be considered state-of-the-art by addressing uncertainties related to spatial extent of hydraulic windows. The reviews from the regulators were thorough and often provided useful concepts for consideration and future/study resolutions. The overarching consensus recommendation of independent review team is that the LANL groundwater plumes should be addressed in context of the emerging "management of complex sites" paradigm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation

Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual/Augmented Reality (VR/AR):Tools for Nuclear Training, Operations and Design

Introduction: Problems: Mistakes in the field due to a lack of information (Ex: Pump repair failure rate 50%); Avoidable exposure due to multiple employees for procedure adherence and monitoring; Debates over 2D drawings can be more easily resolved. Purpose: Training: Employees can be trained more effectively. Operating: Operations can be carried out more efficiently with fewer workers required with AR. Design Review: Pull the designers and designs into VR. Design: VR: Unreal Engine, Unity, Custom. AR: HoloLens: Unity, Custom - DirectX 12.

42 ENGINEERING↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Bipolar Membranes for Ion Management in (Photo)Electrochemical Energy Conversion

Conspectus (Photo)electrochemical energy conversion is important in the development of a carbon-neutral energy economy because it can provide a pathway for mitigating the intermittency of renewable energy sources such as wind and solar. In order to operate efficiently, these technologies, which include photoelectrochemical cells, water and CO 2 electrolyzers, fuel cells, and redox flow batteries, require fast charge transfer kinetics at the electrode/electrolyte interface as well as robust ion management in the electrolyte. In conventional electrolyzers and fuel cells, the electrolyte is strongly acidic or basic and ionic current is carried by H + or OH – ions. In contrast, photoelectrodes and electrocatalysts for water splitting are often studied in buffered solutions. The question of ion balance in these systems led us to analyze the polarization losses due to ion concentration gradients in cells that employed various buffer–membrane combinations. Continuously driving the buffer ions across an ionomer membrane not only lowers the buffer capacity of an aqueous electrolyte but also introduces pH gradients that result in significant energy losses. To address the problem, we and other groups have studied the use of reverse-biased bipolar membranes (BPMs) in (photo)electrolytic cells. BPMs consist of an anion exchange layer (AEL) laminated with a cation exchange layer (CEL) and are usually equipped with a catalytic layer in between to accelerate the water dissociation reaction. At the AEL/CEL interface, water dissociates into protons and hydroxide ions, which replenish those consumed at the cathode and anode. Compared to conventional water electrolyzers with proton/anion exchange membranes (PEM/AEM), BPM electrolyzers provide the unique advantage of continuously operating the cathode and anode under different pH conditions, which is desirable when the two electrode reactions have different pH requirements. BPMs also enable the use of buffered electrolytes at pH values that are optimized for electrode stability and product selectivity in applications such as CO 2 electrolysis. Product crossover losses and CO 2 pumping can be dramatically reduced in BPM-based CO 2 electrolyzers, relative to conventional alkaline membranes, by electrostatic repulsion (of anionic products) and electroosmotic drag (for neutral products). BPM-based gas fed CO 2 electrolyzers can achieve high current density, but they suffer from low Faradaic efficiency (FE) due to the acidic local environment of the CEL. This problem can be mitigated by adding an aqueous buffering layer or by creating a weak acid cation exchange film on the CEL face of the membrane. The use of BPMs in fuel cells and redox flow batteries offers some interesting advantages. Configurations with both reverse and forward bias have been studied, but forward bias has been favored due to material compatibility, reaction kinetics, and thermodynamic considerations. The net reaction at the AEL/CEL interface is the acid–base neutralization reaction, which has a high inherent reaction rate constant, but in the BPM is limited to a nanometric space-charge layer and requires efficient catalysis to achieve high current density. Understanding the mechanism of the acid–base neutralization and the opposite process, the water dissociation reaction, will be essential for improving the performance of forward-biased BPMs. In conclusion, this Account reviews our current understanding of the working mechanisms of BPMs and discusses how we can use them to effectively manage ions for various (photo)electrochemical applications.

Yan, Zhifei↗