Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “proton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Proton Beam Therapy for Hepatocellular Carcinoma Located Adjacent to the Alimentary Tract;Proton beam therapy; Hepatocellular carcinoma; Gastrointestinal bleeding

Purpose: To evaluate the safety and effectiveness of proton beam therapy for hepatocellular carcinoma (HCC) located adjacent to the alimentary tract. Patients and Methods: Forty-seven patients (median age, 69 years; range, 43-82 years) who had HCC located within 2 cm of the alimentary tract underwent proton beam therapy. Liver damage according to the Child-Pugh classification was Class A in 35 patients, Class B in 9, and Class C in 3. Treatment protocols of the early 16 patients and the late 31 patients were 72.6 GyE in 22 fractions and 77 GyE in 35 fractions, respectively. Results: During the median follow-up period of 23 months, 24 patients died; the remaining 23 patients were alive until September 2008. The median overall survival was 33.9 months (95% confidence interval [CI], 10.8-57.0 months). Actuarial overall and local progression-free survival rates at 3 years were 50.0% and 88.1%, respectively. Grade 2 and 3 alimentary tract hemorrhage was observed in 3 (6.4%) and 1 (2.1%) patients, respectively. Conclusions: Our proton beam therapy strategy for HCC located adjacent to the alimentary tract seems to be effective but should be performed with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shortening Delivery Times of Intensity Modulated Proton Therapy by Reducing Proton Energy Layers During Treatment Plan Optimization

Purpose: To shorten delivery times of intensity modulated proton therapy by reducing the number of energy layers in the treatment plan. Methods and Materials: We have developed an energy layer reduction method, which was implemented into our in-house-developed multicriteria treatment planning system “Erasmus-iCycle.” The method consisted of 2 components: (1) minimizing the logarithm of the total spot weight per energy layer; and (2) iteratively excluding low-weighted energy layers. The method was benchmarked by comparing a robust “time-efficient plan” (with energy layer reduction) with a robust “standard clinical plan” (without energy layer reduction) for 5 oropharyngeal cases and 5 prostate cases. Both plans of each patient had equal robust plan quality, because the worst-case dose parameters of the standard clinical plan were used as dose constraints for the time-efficient plan. Worst-case robust optimization was performed, accounting for setup errors of 3 mm and range errors of 3% + 1 mm. We evaluated the number of energy layers and the expected delivery time per fraction, assuming 30 seconds per beam direction, 10 ms per spot, and 400 Giga-protons per minute. The energy switching time was varied from 0.1 to 5 seconds. Results: The number of energy layers was on average reduced by 45% (range, 30%-56%) for the oropharyngeal cases and by 28% (range, 25%-32%) for the prostate cases. When assuming 1, 2, or 5 seconds energy switching time, the average delivery time was shortened from 3.9 to 3.0 minutes (25%), 6.0 to 4.2 minutes (32%), or 12.3 to 7.7 minutes (38%) for the oropharyngeal cases, and from 3.4 to 2.9 minutes (16%), 5.2 to 4.2 minutes (20%), or 10.6 to 8.0 minutes (24%) for the prostate cases. Conclusions: Delivery times of intensity modulated proton therapy can be reduced substantially without compromising robust plan quality. Shorter delivery times are likely to reduce treatment uncertainties and costs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reassessment of the Necessity of the Proton Gantry: Analysis of Beam Orientations From 4332 Treatments at the Massachusetts General Hospital Proton Center Over the Past 10 Years

Purpose: To retrospectively analyze the beam approaches used in gantry-based proton treatments, and to reassess the practical advantages of the gantry, compared with beam approaches that are achievable without a gantry, in the context of present-day technology. Methods and Materials: We reviewed the proton therapy plans of 4332 patients treated on gantries at our hospital, delivered by the double scattering technique (n=4228) and, more recently, pencil beam scanning (PBS) (n=104). Beam approaches, relative to the patient frame, were analyzed individually to identify cases that could be treated without a gantry. Three treatment configurations were considered, with the patient in lying position, sitting position, or both. The FIXED geometry includes a fixed horizontal portal. The BEND geometry enables a limited vertical inflection of the beam by up to 20°. The MOVE geometry allows for flexibility of the patient head and body setup. Results: The percentage of patients with head and neck tumors that could be treated without a gantry using double scattering was 44% in FIXED, 70% in 20° BEND, and 100% in 90° MOVE. For torso regions, 99% of patients could be treated in 20° BEND. Of 104 PBS treatments, all but 1 could be reproduced with FIXED geometry. The only exception would require a 10° BEND capability. Note here that the PBS treatments were applied to select anatomic sites, including only 2 patients with skull-base tumors. Conclusions: The majority of practical beam approaches can be realized with gantry-less delivery, aided by limited beam bending and patient movements. Practical limitations of the MOVE geometry, and treatments requiring a combination of lying and sitting positions, may lower the percentage of head and neck patients who could be treated without a gantry. Further investigation into planning, immobilization, and imaging is needed to remove the practical limitations and to facilitate proton treatment without a gantry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy

Purpose: To present a novel robust and delivery-efficient spot-scanning proton arc (SPArc) therapy technique. Methods and Materials: A SPArc optimization algorithm was developed that integrates control point resampling, energy layer redistribution, energy layer filtration, and energy layer resampling. The feasibility of such a technique was evaluated using sample patients: 1 patient with locally advanced head and neck oropharyngeal cancer with bilateral lymph node coverage, and 1 with a nonmobile lung cancer. Plan quality, robustness, and total estimated delivery time were compared with the robust optimized multifield step-and-shoot arc plan without SPArc optimization (Arc{sub multi-field}) and the standard robust optimized intensity modulated proton therapy (IMPT) plan. Dose-volume histograms of target and organs at risk were analyzed, taking into account the setup and range uncertainties. Total delivery time was calculated on the basis of a 360° gantry room with 1 revolutions per minute gantry rotation speed, 2-millisecond spot switching time, 1-nA beam current, 0.01 minimum spot monitor unit, and energy layer switching time of 0.5 to 4 seconds. Results: The SPArc plan showed potential dosimetric advantages for both clinical sample cases. Compared with IMPT, SPArc delivered 8% and 14% less integral dose for oropharyngeal and lung cancer cases, respectively. Furthermore, evaluating the lung cancer plan compared with IMPT, it was evident that the maximum skin dose, the mean lung dose, and the maximum dose to ribs were reduced by 60%, 15%, and 35%, respectively, whereas the conformity index was improved from 7.6 (IMPT) to 4.0 (SPArc). The total treatment delivery time for lung and oropharyngeal cancer patients was reduced by 55% to 60% and 56% to 67%, respectively, when compared with Arc{sub multi-field} plans. Conclusion: The SPArc plan is the first robust and delivery-efficient proton spot-scanning arc therapy technique, which could potentially be implemented into routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Layer Graphene Sandwiched between Proton-Exchange Membranes for Selective Proton Transmission

Proton transmission through single-layer CVD graphene in graphene/proton-exchange-membrane (PEM) sandwich structures is found to be more than 100 times faster than for any other cation. Ion transmission rates were measured for protons and a series of other cations including Li + , Na + , K + , Rb + , Cs + , and NH 4 + using a four-electrode method in which two platinum electrodes drive ionic current through the membrane and two reference electrodes installed in Luggin capillaries sense the transmembrane potential difference induced by the forced ion flow. Characterization studies including confocal Raman microscopy and X-ray photoelectron spectroscopy for graphene on Nafion, and defect visualization by etching through defects for graphene on copper, are also reported. All findings are consistent with a defect-based mechanism for transmission through graphene of all cations except protons, which likely follow a different mechanism, perhaps involving high-rate transmission through sites at which transmission of other ions is forbidden. Electrochemical impedance spectroscopy (EIS) was also used to study ion transmission rates through graphene in PEM sandwich structures. EIS gave much lower resistances for ion transmission through graphene than were obtained using the four-electrode method. Here, this latter finding is thought to reflect a capacitive coupling of mobile ions with/through graphene at the high frequencies (up to 100 kHz) used in the EIS measurement. Near-steady-state dc methods are thus necessary to evaluate true ion transmission rates through graphene.

Ion transmission↗

Reorganization Energies for Interfacial Proton-Coupled Electron Transfer to a Water Oxidation Catalyst

The reorganization energy (λ) for interfacial electron transfer (ET) and proton-coupled electron transfer (PCET) from a conductive metal oxide (In 2 O 3 :Sn, ITO) to a surface-bound water oxidation catalyst were extracted from kinetic data measured as a function of the thermodynamic driving force. Visible light excitation resulted in rapid excited-state injection (k inj > 10 8 s -1 ) to the ITO, which photo-initiated the two interfacial reactions of interest. The rate constants for both reactions increased with the driving force, −ΔG°, to a saturating limit, k max , with rate constants consistently larger for ET than for PCET. Marcus-Gerischer analysis of the kinetic data provided the reorganization energy for interfacial PCET (0.90 ± 0.02 eV) and ET (0.40 ± 0.02 eV), respectively. The magnitude of k max for PCET was found to decrease with pH, behavior that was absent for ET. Both the decrease in k max and the larger reorganization energy for an unwanted competing PCET reaction from the ITO to the oxidized catalyst showcases a significant kinetic advantage for driving solar water oxidation at high pH. Computational analysis revealed a larger inner-sphere reorganization energy contribution for PCET than for ET arising from a more significant change in the Ru–O bond length for PCET. Extending Marcus-Gerischer theory to PCET by including the excited electron-proton vibronic states and the proton donor-acceptor motion provided an apparent reorganization energy of 1.01 eV. Furthermore, this study demonstrates that the Marcus-Gerischer theory initially developed for ET can be reliably extended to PCET for quantifying and interpreting reorganization energies observed experimentally.

Catalysts Kinetic parameters↗

Direct Evidence for a Sequential Electron Transfer–Proton Transfer Mechanism in the PCET Reduction of a Metal Hydroxide Catalyst

Here, the proton-coupled electron transfer (PCET) mechanism for the reaction M ox -OH + e − + H + → M red -OH 2 was de-termined through kinetic resolution of the independent electron transfer (ET) and proton transfer (PT) steps. The reaction of interest was triggered by visible light excitation of [Ru II (tpy)(bpy′)H 2 O] 2+ , Ru II -OH 2 , where tpy is 2,2′:6′,2″-terpyridine and bpy′ is 4,4′-diaminopropylsilatrane-2,2′-bipyridine, anchored to In 2 O 3 :Sn (ITO) thin films in aqueous solutions. Interfacial kinetics for the PCET reduction reaction were quantified by nanosecond transient absorption spectroscopy as a function of solution pH and applied potential. Data acquired from pH = 5-10 revealed a stepwise electron-transfer proton-transfer (ET-PT) mechanism, while kinetic measurements made below the pK a (Ru III -OH/OH 2 ) = 1.3 were used to study the analogous interfacial reaction where electron transfer was the only mechanistic step. Analysis of this data with a recently reported multi-channel kinetic model was used to construct a PCET zone diagram and supported the assignment of an ET-PT mechanism from pH = 5-10. Ultimately, this study represents a unique example amongst M ox -OH/M red -OH 2 reactivity where the protona-tion and oxidation state of the intermediate was kinetically and spectrally resolved to firmly establish the PCET mechanism.

Charge transfer↗

Proton-Coupled Electron Transfer Mechanisms for CO 2 Reduction to Methanol Catalyzed by Surface-Immobilized Cobalt Phthalocyanine

Immobilized cobalt phthalocyanine (CoPc) is a highly promising architecture for the six-proton, six-electron reduction of CO 2 to methanol. This electroreduction process relies on proton-coupled electron transfer (PCET) reactions that can occur by sequential or concerted mechanisms. Immobilization on a conductive support such as carbon nanotubes or graphitic flakes can fundamentally alter the PCET mechanisms. We use density functional theory (DFT) calculations of CoPc adsorbed on an explicit graphitic surface model to investigate intermediates in the electroreduction of CO 2 to methanol. Our calculations show that the alignment of the CoPc and graphitic electronic states influences the reductive chemistry. These calculations also distinguish between charging the graphitic surface and reducing the CoPc and adsorbed intermediates as electrons are added to the system. This analysis allows us to identify the chemical transformations that are likely to be concerted PCET, defined for these systems as the mechanism in which protonation of a CO 2 reduction intermediate is accompanied by electron abstraction from the graphitic surface to the adsorbate without thermodynamically stable intermediates. Furthermore, this work establishes a mechanistic pathway for methanol production that is consistent with experimental observations and provides fundamental insight into how immobilization of the CoPc impacts its CO 2 reduction chemistry.

Adsorption↗

Observation of impurity free monoenergetic proton beams from the interaction of a CO{sub 2} laser with a gaseous target

A monoenergetic proton beam is observed from the interaction of a short-pulse infrared ({lambda} = 10.6 {mu}m) laser at intensity I = 6 x 10{sup 15} W cm{sup -2} with a gas jet target. The proton beam is found to have narrow energy spread ({approx} 4% ), high spectral brightness ({approx} 10{sup 12} protons/MeV/sr), low normalized emittance ({epsilon}{sub n{approx_equal}} 8 nm rad), and high contrast (> 200 x over noise). The narrow energy spread and low levels of impurity makes this method an interesting route for high-repetition rate high quality proton beam production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduction in thermal boundary conductance due to proton implantation in silicon and sapphire

We measure the thermal boundary conductance across Al/Si and Al/Al{sub 2}O{sub 3} interfaces that are subjected to varying doses of proton ion implantation with time domain thermoreflectance. The proton irradiation creates a major reduction in the thermal boundary conductance that is much greater than the corresponding decrease in the thermal conductivities of both the Si and Al{sub 2}O{sub 3} substrates into which the ions were implanted. Specifically, the thermal boundary conductances decrease by over an order of magnitude, indicating that proton irradiation presents a unique method to systematically decrease the thermal boundary conductance at solid interfaces.

36 MATERIALS SCIENCE↗

A molecular dynamics study of intramolecular proton transfer reaction of malonaldehyde in solutions based upon mixed quantum-classical approximation. I. Proton transfer reaction in water

In order to investigate proton transfer reaction in solution, mixed quantum-classical molecular dynamics calculations have been carried out based on our previously proposed quantum equation of motion for the reacting system [A. Yamada and S. Okazaki, J. Chem. Phys. 128, 044507 (2008)]. Surface hopping method was applied to describe forces acting on the solvent classical degrees of freedom. In a series of our studies, quantum and solvent effects on the reaction dynamics in solutions have been analysed in detail. Here, we report our mixed quantum-classical molecular dynamics calculations for intramolecular proton transfer of malonaldehyde in water. Thermally activated proton transfer process, i.e., vibrational excitation in the reactant state followed by transition to the product state and vibrational relaxation in the product state, as well as tunneling reaction can be described by solving the equation of motion. Zero point energy is, of course, included, too. The quantum simulation in water has been compared with the fully classical one and the wave packet calculation in vacuum. The calculated quantum reaction rate in water was 0.70 ps{sup −1}, which is about 2.5 times faster than that in vacuum, 0.27 ps{sup −1}. This indicates that the solvent water accelerates the reaction. Further, the quantum calculation resulted in the reaction rate about 2 times faster than the fully classical calculation, which indicates that quantum effect enhances the reaction rate, too. Contribution from three reaction mechanisms, i.e., tunneling, thermal activation, and barrier vanishing reactions, is 33:46:21 in the mixed quantum-classical calculations. This clearly shows that the tunneling effect is important in the reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Proton microbeam formation with continuously variable kinetic energy using a compact system for three-dimensional proton beam writing

A compact focused gaseous ion beam system has been developed to form proton microbeams of a few hundreds of keV with a penetration depth of micrometer range in 3-dimensional proton beam writing. Proton microbeams with kinetic energies of 100-140 keV were experimentally formed on the same point at a constant ratio of the kinetic energy of the object side to that of the image side. The experimental results indicate that the beam diameters were measured to be almost constant at approximately 6 μm at the same point with the kinetic energy range. These characteristics of the system were experimentally and numerically demonstrated to be maintained as long as the ratio was constant.

07 ISOTOPE AND RADIATION SOURCES↗

Correlated proton-electron hole dynamics in protonated water clusters upon extreme ultraviolet photoionization

The ultrafast nuclear and electronic dynamics of protonated water clusters H+(H2O)n after extreme ultraviolet photoionization is investigated. In particular, we focus on cluster cations with n = 3, 6, and 21. Upon ionization, two positive charges are present in the cluster related to the excess proton and the missing electron, respectively. A correlation is found between the cluster's geometrical conformation and initial electronic energy with the size of the final fragments produced. As a result, for situations in which the electron hole and proton are initially spatially close, the two entities become correlated and separate in a time-scale of 20 to 40 fs driven by strong non-adiabatic effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy dependence of kaon-to-proton ratio fluctuations in central Pb+Pb collisions from {radical}(s{sub NN})=6.3 to 17.3 GeV

Kaons and protons carry large parts of two conserved quantities: strangeness and baryon number. It is argued that their correlation and thus also fluctuations are sensitive to conditions prevailing at the anticipated parton-hadron phase boundary. Fluctuations of the (K{sup +}+K{sup -})/(p+p) and K{sup +}/p ratios have been measured for the first time by NA49 in central Pb+Pb collisions at five CERN Super Proton Synchrotron energies between {radical}(s{sub N{sub N}})=6.3 and {radical}(s{sub N{sub N}})=17.3 GeV. Both ratios exhibit a change of sign in {sigma}{sub dyn}, a measure of nonstatistical fluctuations, around {radical}(s{sub N{sub N}})=8 GeV. Below this energy, {sigma}{sub dyn} is positive, indicating higher fluctuation compared to a mixed event background sample, while for higher energies, {sigma}{sub dyn} is negative, indicating correlated emission of kaons and protons. The results are compared to hadronic transport model calculations which fail to reproduce the energy dependence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-214: Intensity Modulated Proton Therapy (IMPT) Based On Passively Scattered Protons and Multi-Leaf Collimation: Prototype TPS and Dosimetry Study

Purpose. Intensity-modulated proton therapy is usually implemented with multi-field optimization of pencil-beam scanning (PBS) proton fields. However, at the view of the experience with photon-IMRT, proton facilities equipped with double-scattering (DS) delivery and multi-leaf collimation (MLC) could produce highly conformal dose distributions (and possibly eliminate the need for patient-specific compensators) with a clever use of their MLC field shaping, provided that an optimal inverse TPS is developed. Methods. A prototype TPS was developed in MATLAB. The dose calculation process was based on a fluence-dose algorithm on an adaptive divergent grid. A database of dose kernels was precalculated in order to allow for fast variations of the field range and modulation during optimization. The inverse planning process was based on the adaptive simulated annealing approach, with direct aperture optimization of the MLC leaves. A dosimetry study was performed on a phantom formed by three concentrical semicylinders separated by 5 mm, of which the inner-most and outer-most were regarded as organs at risk (OARs), and the middle one as the PTV. We chose a concave target (which is not treatable with conventional DS fields) to show the potential of our technique. The optimizer was configured to minimize the mean dose to the OARs while keeping a good coverage of the target. Results. The plan produced by the prototype TPS achieved a conformity index of 1.34, with the mean doses to the OARs below 78% of the prescribed dose. This Result is hardly achievable with traditional conformal DS technique with compensators, and it compares to what can be obtained with PBS. Conclusion. It is certainly feasible to produce IMPT fields with MLC passive scattering fields. With a fully developed treatment planning system, the produced plans can be superior to traditional DS plans in terms of plan conformity and dose to organs at risk.

60 APPLIED LIFE SCIENCES↗