Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-JeP3-05: Geometry Based Transperineal Ultrasound Probe Positioning for Image Guided Radiotherapy

Purpose: The use of ultrasound (US) imaging in radiotherapy is not widespread, primarily due to the need for skilled operators performing the scans. Automation of probe positioning has the potential to remove this need and minimize operator dependence. We introduce an algorithm for obtaining a US probe position that allows good anatomical structure visualization based on clinical requirements. The first application is on 4D transperineal US images of prostate cancer patients. Methods: The algorithm calculates the probe position and orientation using anatomical information provided by a reference CT scan, always available in radiotherapy workflows. As initial test, we apply the algorithm on a CIRS pelvic US phantom to obtain a set of possible probe positions. Subsequently, five of these positions are randomly chosen and used to acquire actual US volumes of the phantom. Visual inspection of these volumes reveal if the whole prostate, and adjacent edges of bladder and rectum are fully visualized, as clinically required. In addition, structure positions on the acquired US volumes are compared to predictions of the algorithm. Results: All acquired volumes fulfill the clinical requirements as specified in the previous section. Preliminary quantitative evaluation was performed on thirty consecutive slices of two volumes, on which the structures are easily recognizable. The mean absolute distances (MAD) between actual anatomical structure positions and positions predicted by the algorithm were calculated. This resulted in MAD of 2.4±0.4 mm for prostate, 3.2±0.9 mm for bladder and 3.3±1.3 mm for rectum. Conclusion: Visual inspection and quantitative evaluation show that the algorithm is able to propose probe positions that fulfill all clinical requirements. The obtained MAD is on average 2.9 mm. However, during evaluation we assumed no errors in structure segmentation and probe positioning. In future steps, accurate estimation of these errors will allow for better evaluation of the achieved accuracy.

60 APPLIED LIFE SCIENCES↗

New Applications of Langmuir Probes

In this work, two new possibilities for standard probe diagnostics are described. The first one can be used to study isotropic, collisionless low-pressure plasma in which the electron energy distribution function is close to a Maxwellian one. In such plasmas, the Boltzmann law, Bohm effect, and 3/2 power law are valid. Use of corresponding system of equations for cylindrical Langmuir probes allowed for measurements of probe sheath thicknesses and the mean ion mass. The solution of this task was provided by accurate probe diagnostics of inductive xenon plasma at pressure p = 2 mTorr that resulted in the determination of the Bohm coefficient C{sub BCyl} = 1.22. The second possibility of probe diagnostics includes a method and device for evaluation of ion current density to a wall under a floating potential using a radially movable plane wall Langmuir probe simulator. This measurement in the same xenon plasma served as the basis for development of an ion source in which the given wall was represented by an ion extracting electrode of the ion extraction grid system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large Observatory for X-ray Timing (LOFT-P): A Probe-Class Mission Concept Study

LOFT-P is a mission concept for a NASA Astrophysics Probe-Class (less than $1B) X-ray timing mission, based on the LOFT M-class concept originally proposed to ESA's M3 and M4 calls. LOFT-P requires very large collecting area, high time resolution, good spectral resolution, broadband spectral coverage (2-30 keV), highly flexible scheduling, and an ability to detect and respond promptly to time-critical targets of opportunity. Many of LOFTP's targets are bright, rapidly varying sources, so these measurements are synergistic to imaging and high-resolution spectroscopy instruments, addressing much smaller distance scales than are possible without very long baseline X-ray interferometry, and using complementary techniques to address the geometry and dynamics of emission regions. LOFT-P was presented as an example mission to the head of NASA's Astrophysics Division, to demonstrate the strong community support for creation of a probe-class, for missions costing between $500M and $1B. We submitted a white paper4 in response to NASA PhysPAG's call for white papers: Probe-class Mission Concepts, describing LOFT-P science and a simple extrapolation from the ESA study costs. The next step for probe-class missions will be input into the NASA Astrophysics Decadal Survey to encourage the creation of a probe-class opportunity. We report on a 2016 study by MSFC's Advanced Concepts Office of LOFT-P, a US-led probe-class LOFT concept.

x-ray↗

Diffraction Modeling of Finite Subband EFC Probing on Dark Hole Contrast with WFIRST-CGI Shaped Pupil Coronagraph

The current NASA WFIRST (Wide-Field InfraRed Survey Telescope) coronagraph instrument (CGI) design allocates two subband filters per each full science band in order to contain system complexity and cost. We present our detailed investigation results on the adequacy of such a limited number of finite subband filters in achieving broadband dark hole contrast with a shaped pupil coronagraph (SPC). The study is based on diffraction propagation modeling with realistic WFIRST optics, where each subband’s image plane electric field is estimated from pairwise pupil plane deformable mirror (DM) probing and image plane intensity averaging of the resulting fields of multiple (subband) wavelengths. Multiple subband choices and probing and control strategies are explored, including standard subband probing; mixed wavelength and/or weighted Jacobian matrix; subband probing with intensity subtraction; and extended subband probing with intensity subtraction. Overall, the investigation shows that the achievable contrast with a limited number of finite subbands is about 2~2.5x worse than the designed contrast for the current SPC. The result suggests that future shaped pupil designs should be optimized for slightly broader bandwidths than the intended science bandpasses if limited subbands are used for wavefront sensing via probing.

WFIRST↗

Entry, Descent, and Landing Analysis of Low Mass Martian Probe for Surface Climate Network

Aeolus is a mission to provide the first direct measurements of Martian atmospheric wind speeds and correlate them with thermal and compositional data to bring together a complete systematic description for the global energy balance and climate cycles of Mars. Objective A of the Mars Exploration Program Analysis Group (MEPAG) Goal II cites a Science Investigation Area to develop a network of surface landers to provide global, diurnal and synoptic coverage of the near-surface environment to characterize present Mars climate [1]. Aeolus will characterize the present Martian global climate system via an orbiter element and a novel surface network element. A series of low mass, low power probes will be distributed across the Martian surface and measure pressure, sky opacity, temperature, wind speed, water vapor and other trace gases. Low mass and power electrical systems designed to operate in extreme cold and daily thermal cycling for one Martian year could facilitate lower cost, Class-D science probes. Aeolus is targeting a total per-probe mass of <5 kg. Recent advances in nanofabrication of chip-scale sensors that are highly robust to temperature and shock, combined with a novel packaging concept (the deployable sensor probe [2]) originally developed by the Aerospace Corp., for the first time enables a Mars surface climate sensor network. These probes are folded flat during transit to Mars and automatically deploy into the final reentry configuration once released from the orbiter. The capability to fold for stowage significantly increases the probe quantity carried by the orbiter.

EDL↗

Venus Atmospheric Probe and Flyby Relay Spacecraft Cross-Link Tracking Impact on Relative Pointing Accuracy

Scientific exploration of Venus using an atmospheric probe requires relaying telemetry to Earth as the probe descends through the atmosphere to the surface of Venus. Using the flyby spacecraft to relay the probe telemetry to Earth will require precise carrier-to-probe pointing accuracy of the relay spacecraft’s antenna. NASA’s Deep Atmosphere Venus Investigation of Noble gases, Chemistry, and Imaging (DAVINCI) mission uses this carrier-to-probe relay technique. Although DAVINCI includes a coherent cross-link for science, this is not baselined for navigation tracking. This paper explores the potential effectiveness of cross-link tracking for reducing trajectory uncertainty and improving spacecraft-to-probe pointing.

DAVINCI↗

Can quantum probes satisfy the weak equivalence principle?

We address the question whether quantum probes in a gravitational field can be considered as test particles obeying the weak equivalence principle (WEP). A formulation of the WEP is proposed which applies also in the quantum regime, while maintaining the physical content of its classical counterpart. Such formulation requires the introduction of a gravitational field not to modify the Fisher information about the mass of a freely-falling probe, extractable through measurements of its position. We discover that, while in a uniform field quantum probes satisfy our formulation of the WEP exactly, gravity gradients can encode nontrivial information about the particle’s mass in its wavefunction, leading to violations of the WEP. - Highlights: • Can quantum probes under gravity be approximated as test-bodies? • A formulation of the weak equivalence principle for quantum probes is proposed. • Quantum probes are found to violate it as a matter of principle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and development of a probe-based multiplexed multi-species absorption spectroscopy sensor for characterizing transient gas-parameter distributions in the intake systems of I.C. engines

We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2 O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuring gas temperature, pressure, and H 2 O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.

33 ADVANCED PROPULSION SYSTEMS↗

Accessing crystal–crystal interaction forces with oriented nanocrystal atomic force microscopy probes

Biominerals serve as crucial structures of living systems and play an important role for biochemical processes. Understanding their crystallization mechanisms is therefore central to many areas of biology, biogeoscience and biochemistry. Some biominerals, such as bone and dentin, are hierarchical nanocomposite structures constructed by sequentially added individual oriented nanocrystals. The driving forces that enable this oriented assembly are still poorly understood, with advances in understanding limited in part by the availability of techniques that can precisely measure the delicate interactions between nanocrystals, as a function of their separation distance and mutual orientation. Here we provide a novel and comprehensive protocol for i.) fabricating oriented single nanocrystal atomic force microscopy (AFM) probes using focus ion beam (FIB) milling - probes that are capable of accessing the nanoscale forces between oriented single-crystal faces, and ii.) performing oriented nanocrystal interaction force measurements using dynamic force spectroscopy (DFS) and environmental transmission electron microscopy (ETEM)-AFM techniquqes. These methods have recently led to seminal breakthroughs in force quantification for understanding oriented aggregation at the nanoscale. First, we detail two FIB milling based methods to fabricate AFM nanocrystal probes. One method requires careful pre-coating with a protective layer to avoid FIB damage to the face of interest, which is later chemically removed, and the other entails removal of the FIB damage layer with in situ polishing. We illustrate how to fabricate oriented nanocrystal force probes using commercial bulk crystals or nano/micro-crystals of calcite, zinc oxide, and rutile; the methods are fully transferrable to the apatites comprising bone minerals. The typical protocol for fabricating one AFM crystal probe takes 2-3 h. Finally, we describe how to measure interaction forces between nanocrystals in solution conditions of interest by performing AFM based DFS, or in the controlled environment of ETEM, using the resulting oriented nanocrystal probes. In addition, we illustrate how to quantify the direction-specific interaction forces for a given pair of interacting oriented nanocrystal faces, and how to relate this information generally to understanding crystallization by particle attachment.

Zhang, Xin (ORCID:000000032000858X)↗

The detonation cylinder test: Determination of full wall velocity and shape from a single velocimetry probe with an arbitrary angle

Laser velocimetry probes are used for measuring wall velocity in cylinder test expansion experiments. Previously, a method was developed to determine the full wall velocity, angle and case shape from a single probe aligned with the initial cylinder wall normal (S.I. Jackson, Proc. Combust. Inst., Vol. 35, 2015, pg.1997-2004). However, probes are often positioned at arbitrary (non-normal) angles to optimize light return from the cylinder surface. This work extends the prior method to accommodate arbitrary probe angles and allows solution of the full cylinder wall motion and shape from a single probe, using only the assumption of steady flow in the shock frame. When used in conjunction with the prior method, it can also be used to approximate the detonation product isentrope analytically from a single velocimetry probe at any angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor

An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod’s vertical target plate divertor and operated over multiple campaigns. The “flush” geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional “proud” tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes. The new rail probes successfully operated during C-Mod’s FY2015 and FY2016 experimental campaigns with no evidence of damage, despite being regularly subjected to heat flux densities parallel to the magnetic field exceeding ~1 GW m -2 for short periods of time. A comparison between rail and proud probe data indicates that sheath expansion effects were successfully mitigated by the rail design, extending the use of these Langmuir probes to incident magnetic field line angles as low as 0.5°.

47 OTHER INSTRUMENTATION↗

Probe measurements of electric field and electron density fluctuations at megahertz frequencies using in-shaft miniature circuits

In this work, a four-tip electrostatic probe is constructed to measure high-frequency (0.1–10 MHz) fluctuations in both the electric field (one component) and electron density in a laboratory plasma. This probe also provides data for the local electron temperature and density. Circuits for high-frequency measurements are fabricated on two miniature boards, which are embedded in the probe shaft, near the tips to minimize the pickup of common-mode signals. The amplitude and phase response of two circuits to sinusoidal test signals are measured and compared with results from modeling. For both circuits, the phase shift between input and output signals is relatively small (<30°). The performance of the probe is verified in a high-density (~10 13 cm –3 ) and low-temperature (≲10 eV) plasma. The probe successfully measures high-frequency (~2 MHz) fluctuations in the electric field and density, which are associated with lower hybrid drift waves. This probe can provide information on the wave-associated anomalous drag, which can be compared with the classical resistivity.

47 OTHER INSTRUMENTATION↗

Ion-temperature determination with a baffled Langmuir probe

An electrostatic Langmuir probe for real-time measurements of parameters in magnetized plasma is tested in fully ionized, barium, Q-machine plasma. The small-diameter, long-length, tungsten wire sensor, i.e., the probe tip, oriented with its cylindrical axis perpendicular to the magnetic field (B), is partially shielded by ceramic baffles, or masks, that form sensor-access slots between the baffles. Adjusting the azimuthal orientation of the slots, by rotating the probe about its cylindrical axis, changes the fraction of proximity gyro-orbiting electrons, relative to the fraction of proximity gyro-orbiting ions, that can access the recessed sensor along the magnetic field. Thus, the ratio between the electron and ion saturation currents, $I^{sat}_e$ and $I^{sat}_i$, can be adjusted without having affected the probe bias voltage V b . When optimally shielded ($I^{sat}_e/I^{sat}_i$=1), accurate, real-time measurements of space potential Vs can be acquired. When maximally shielded ($I^{sat}_e/I^{sat}_i$ << 1), accurate, real-time measurements of ion temperature T i can be acquired. Subtracting the floating potential V f of an optimally shielded baffled probe from V f of a maximally shielded baffled probe yields T i (and its fluctuation phase) in real time.

47 OTHER INSTRUMENTATION↗

All-in-one probe for exploring self-organized two-fluid equilibria in toroidal plasmas

This paper presents the development of an all-in-one probe to simultaneously measure all components of the generalized Ohm’s law in reversed-field pinch plasmas and tokamaks. The polyhedral configuration of the Mach probe is achieved through the specific arrangement, angle, and depth of the collimator channel apertures drilled into the surface of a hollow boron nitride cylinder encasing it. This probe includes a central Mach probe to assess the ion velocity field in three dimensions. Initial tests at the RELAX and Madison Symmetric Torus machines have confirmed the probe’s effectiveness, revealing an octahedron form similar to a tetrahedron. The probe seems to function correctly and is expected to facilitate the empirical validation of two-fluid equilibria at the periphery of toroidal plasmas.

Instruments & Instrumentation↗

Quantification of in-contact probe-sample electrostatic forces with dynamic atomic force microscopy

Here, atomic force microscopy (AFM) methods utilizing resonant mechanical vibrations of cantilevers in contact with a sample surface have shown sensitivities as high as few picometers for detecting surface displacements. Such a high sensitivity is harnessed in several AFM imaging modes. Here, we demonstrate a cantilever-resonance-based method to quantify electrostatic forces on a probe in the probe-sample junction in the presence of a surface potential or when a bias voltage is applied to the AFM probe. We find that the electrostatic forces acting on the probe tip apex can produce signals equivalent to a few pm of surface displacement. In combination with modeling, the measurements of the force were used to access the strength of the electrical field at the probe tip apex in contact with a sample. We find an evidence that the electric field strength in the junction can reach ca. 1 V nm –1 at a bias voltage of a few volts and is limited by non-ideality of the tip-sample contact. This field is sufficiently strong to significantly influence material states and kinetic processes through charge injection, Maxwell stress, shifts of phase equilibria, and reduction of energy barriers for activated processes. Besides, the results provide a baseline for accounting for the effects of local electrostatic forces in electromechanical AFM measurements as well as offer additional means to probe ionic mobility and field-induced phenomena in solids.

36 MATERIALS SCIENCE↗

Probing the progenitors of Type Ia supernovae using circumstellar material interaction signatures

This work aims to study different probes of Type Ia supernova (SN Ia) progenitors that have been suggested to be linked to the presence of circumstellar material (CSM). In particular, we have investigated, for the first time, the link between narrow blueshifted Nai D absorption profiles and the presence and strength of the broad high-velocity Caii near-infrared triplet absorption features seen in SNe Ia around maximum light. With the probes exploring different distances from the SN; Nai D > 10 17 cm, high-velocity Caii features < 10 15 cm. For this, we have used a new intermediate-resolution X-shooter spectral sample of 15 SNe Ia. We do not identify a link between these two probes, implying either that, one (or both) is not physically related to the presence of CSM or that the occurrence of CSM at the distance explored by one probe is not linked to its presence at the distance probed by the other. However, the previously identified statistical excess in the presence of blueshifted (over redshifted) Nai D absorption is confirmed in this sample at high significance and is found to be stronger in SNe Ia hosted by late-type galaxies. This excess is difficult to explain as being from an interstellar-medium origin as has been suggested by some recent modelling, as such an origin is not expected to show a bias for blueshifted absorption. However, a circumstellar origin for these features also appears unsatisfactory based on our new results, given the lack of link between the two probes of CSM investigated.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster — Thur Eve — 77: Implanted Brachythearpy Seed Movement due to Transrectal Ultrasound Probe-Induced Prostate Deformation

The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used to infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗