Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Transitioning the NASA SLR Network to Event Timing Mode for Reduced Systematics, Improved Stability and Data Precision

NASA's legacy Satellite Laser Ranging (SLR) network produces about one-third of the global SLR data to support spacegeodesy. This network of globally distributed stations has been using Time Interval Units (TIU) for range measurements for thelast 25 + years. To improve the reliability of the SLR network and satisfy the need for stable millimeter precision data, a phasedreplacement of the TIUs in the network with picosecond-precise Event Timer Modules was initiated in 2015. This schemeallowed the time of flight and laser transmit epoch measurement to one picosecond resolution. For a network with globalscientific impact, transitioning to a new data generation metrological scheme requires significant data scrutiny and long-termscience data validation. Any long-term testing/measurement has the potential to interrupt the station's daily operational dataflow to the International Laser Ranging Service (ILRS) as the station under test will have to put its test data into quarantine.We have demonstrated a very effective way to test and implement the new device without removing the old hardware andwithout the need for the orbit analysis. This operationally noninvasive scheme performed concurrent test measurements enablinguninterrupted operational data flow to the users, while allowing simultaneous test data capture for short- and long-termsystematics and stability analysis. Extensive analysis of the test data was performed by the NASA SLR engineering team andthe ILRS Analysis Standing Committee, to uncover biases and any dependencies on the satellite ranges (for nonlinear scaleissues). Multi-ETM comparison was also performed at two of the SLR stations through the interchange of hardware to establishthe inter-device range biases and stability. Such benchmarked hardware was subsequently sent to the remaining stationsto allow traceability and normalize the network performance. The range bias intercomparison performed using the multiyearSLR data analysis agreed well with the engineering changes, thus validating the approach to flush out station-specific rangingsystematics affecting precise orbit determination. Such an improvement and rebalancing of the current network will allowan orderly transition of the current NASA SLR network operating at a maximum rate of 10 Hz to the NASA next generationSpace Geodesy Satellite Laser Ranging (SGSLR) network operating at 2 kHz (McGarry et al. in J Geod, 2018. https ://doi.org/10.1007/s0019 0-018-1191-6; Merkowitz et al. in J Geod, 2018. https ://doi.org/10.1007/s0019 0-018-1204-5).

Varghese, Thomas↗

Defining Navigation Requirements for Future Precision Lander Missions

Human mission concepts for both the Moon and Mars require landing precision capabilities beyond the current state of art. The Safe and Precise Landing Integrated Capabilities Evolution (SPLICE) project leverages previous work at NASA to develop multimission precision landing and hazard avoidance (PL&HA) technologies to meet the advanced landing requirements. SPLICE aims to develop guidance, navigation and control (GN&C) capabilities for both Moon and Mars lander missions. The approach the project is using to identify a standard suite begins with developing a PL&HA requirements matrix to inform technology investments. The approach to develop a multi-mission navigation requirements matrix includes identifying representative concepts of operations for both robotic and human missions. It also identifies navigation sensor options with estimated performance parameters. This paper summarizes the concepts of operations and sensors considered to develop the SPLICE PL&HA requirements matrix. A description of the analysis used to determine candidate optimal sensor suites and initial results are provided.

Dwyer Cianciolo, Alicia↗

Overview of terrain relative navigation approaches for Precise Lunar Landing

The driving precision landing requirement for the Autonomous Landing and Hazard Avoidance Technology project is to autonomously land within 100m of a predetermined location on the lunar surface. Traditional lunar landing approaches based on inertial sensing do not have the navigational precision to meet this requirement. The purpose of Terrain Relative Navigation (TRN) is to augment inertial navigation by providing position or bearing measurements relative to known surface landmarks. From these measurements, the navigational precision can be reduced to a level that meets the 100m requirement. There are three different TRN functions: global position estimation, local position estimation and velocity estimation. These functions can be achieved with active range sensing or passive imaging. This paper gives a survey of many TRN approaches and then presents some high fidelity simulation results for contour matching and area correlation approaches to TRN using active sensors. Since TRN requires an a-priori reference map, the paper concludes by describing past and future lunar imaging and digital elevation map data sets available for this purpose.

Montgomery, James F.↗

The SPLICE Project: Continuing NASA Development of GN&C Technologies for Safe and Precise Landing

Guidance, Navigation and Control (GN&C) technologies for precise and safe landing are essential for future robotic science and human exploration missions to solar system destinations with targeted surface locations that pose a significant risk to successful landing and subsequent mission operations. These Entry, Descent and Landing (EDL) technologies are a part of the NASA domain called PL&HA (Precision Landing and Hazard Avoidance) and are considered high-priority capabilities within NASA space technology development roadmaps to promote and enable new mission concepts. The SPLICE (Safe & Precise Landing – Integrated Capabilities Evolution) project is a multi-center, multi-directorate NASA project focused on continuing the decade-plus of NASA investments and projects focused on PL&HA technology development and infusion. This paper highlights the GN&C technologies in development within SPLICE, along with the simulation and field test plans for validation of the capabilities and Technology Readiness Level (TRL) maturation toward infusion into potential near-term robotic lunar landing missions.

Tse, Teming↗

ICESat-2 Precision Orbit Determination

The ICESat-2 Precision Orbit Determination (POD) system computes the precise position of the laser altimeter instrument in inertial space, a measurement necessary for accurate geolocation of individual photon surface returns. ICESat-2 POD solutions are generated by the reduction of Global Positioning System (GPS) double-difference carrier phase observable residuals with NASA Goddard Space Flight Center's GEODYN software. Independent satellite laser ranging (SLR) measurements are withheld from the POD solutions and used as an independent arbiter of POD performance. Measurement model updates in the form of estimated GPS antenna phase center and satellite laser ranging retro-reflector tracking point offset vectors as well as a GPS antenna phase center variation map have led to significant improvement in POD performance. GPS residual analysis and orbit precision analysis show no significant anomalous temporal or geographic POD performance issues. The independent SLR residual analysis indicates that POD solutions have achieved a radial orbit accuracy just below 1.5 cm, thus exceeding the mission radial orbit accuracy requirement of 3.0 cm by more than a factor of 2. Future POD processing updates have been identified and will lead to even further improvements in POD performance.

T. C. Thomas↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Implementation of a Six Degree of Freedom Precision Lunar Landing Algorithm Using Dual Quaternion Representation

In this study, a powered descent guidance algorithm using a unit dual quaternion represen- tation of the vehicle dynamics is implemented in a high-fidelity simulation and on representative flight hardware. This Dual-Quaternion Guidance (DQG) algorithm is applied to the precision lunar landing problem which levies complex constraints upon the trajectory, including state triggered attitude constraints to enable terrain-relative navigation and hazard detection as well as real-time requirements for landing site re-designation. The investigation explores DQG’s usefulness as a mission design tool as well as a real-time guidance algorithm and defines real-time performance requirements for the hazard detection and avoidance (HDA) re-targeting phase of precision lunar landing. The experiment is presented in two parts. First, DQG is implemented within a high-fidelity Monte Carlo simulation to tune the algorithm’s parameters for the simulated vehicle, to refine the mission design, and to develop guidance update timing requirements to perform the HDA maneuver. DQG generates trajectories online for the divert which are tracked by the vehicle’s inner-loop controllers to the targeted landing site. Second, DQG is run on representative hardware to demonstrate real-time operation through a divert maneuver. These results allow for rapid, flexible, optimal mission design satisfying complex constraints, and for the definition of real-time performance requirements for the HDA operations inherent in precision lunar landing. The HDA divert maneuver is found to require guidance trajectory updates in less than three seconds. DQG is found to be too slow to meet this update timing on the descent and landing computer (DLC) in its current implementation. DQG running on alternative hardware can meet the update rate requirement. Algorithm implementation improvements are also recommended which are expected to speed up computation sufficiently to meet requirements on the DLC.

GN&C↗

Precision shape modification of nanodevices with a low-energy electron beam

Methods of shape modifying a nanodevice by contacting it with a low-energy focused electron beam are disclosed here. In one embodiment, a nanodevice may be permanently reformed to a different geometry through an application of a deforming force and a low-energy focused electron beam. With the addition of an assist gas, material may be removed from the nanodevice through application of the low-energy focused electron beam. The independent methods of shape modification and material removal may be used either individually or simultaneously. Precision cuts with accuracies as high as 10 nm may be achieved through the use of precision low-energy Scanning Electron Microscope scan beams. These methods may be used in an automated system to produce nanodevices of very precise dimensions. These methods may be used to produce nanodevices of carbon-based, silicon-based, or other compositions by varying the assist gas.

Zettl, Alex↗

Precision measurements of the top quark mass and width with the D0 detector

Since the discovery of the top quark in 1995 at the Fermliab Tevatron Collider, top quark properties have been measured with ever higher precision. In this article, recent measurements of the top quark mass and its width using up to 3.6 fb{sup -1} of D0 data are summarized. Different techniques and final states have been examined and no deviations within these measurements have been observed. In addition to the direct measurements, a measurement of the top quark mass from its production cross section and a measurement of the top-antitop quark mass difference are discussed. With a mass of 173.3 {+-} 1.1 GeV, the top quark is the heaviest of all known fundamental particles. Due to the high mass, its Yukawa coupling is close to unity suggesting that it may play a special role in electroweak symmetry breaking. Precise measurements of both, the W boson and the top quark mass, constrain the mass of the yet unobserved Higgs boson and allow to restrict certain extensions of the Standard Model. At the Tevatron collider with a center-of-mass energy of 1.96 TeV, 85% of the top quark pairs are produced in quark-antiquark annihilation; 15% originate from gluon fusion. Top quarks are predicted to decay almost exclusively to a W boson and a bottom quark. According to the number of hadronic W decays, top events are classified into all-jets, lepton+jets and dilepton events. The lepton+jets channel is characterized by four jets, one isolated, energetic charged lepton and missing transverse energy. With 30%, the branching fraction of the lepton+jets channel is about seven times larger than the one of the dilepton channel whereas the signal to background ratio is about three times smaller. The main background in this final state comes from W +jets events. Instrumental background arises from events in which a jet is misidentified as an electron and events with heavy hadrons that decay into leptons which pass the isolation requirements. The topology of the dilepton channel is described by two jets, two isolated, energetic charged leptons and significant missing transverse energy from the undetected neutrinos. The main background are Z + jets and diboson events (WW/WZ/ZZ+jets) as well as instrumental background as characterized above. At the D0 experiment, different techniques are used to measure the top quark mass. They are summarized in the following sections together with the first measurement of the top anti-top quark mass difference and the first precise determination of the top quark width.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Workshop on Precision Measurements of $\alpha_s$

These are the proceedings of the Workshop on Precision Measurements of {alpha}{sub s} held at the Max-Planck-Institute for Physics, Munich, February 9-11, 2011. The workshop explored in depth the determination of {alpha}{sub s}(m{sub Z}) in the {ovr MS} scheme from the key categories where high precision measurements are currently being made, including DIS and global PDF fits, {tau}-decays, electro-weak precision observables and Z-decays, event-shapes, and lattice QCD. These proceedings contain a short summary contribution from the speakers, as well as the lists of authors, conveners, participants, and talks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proceedings, High-Precision $\alpha_s$ Measurements from LHC to FCC-ee

This document provides a writeup of all contributions to the workshop on "High precision measurements of $\alpha_s$: From LHC to FCC-ee" held at CERN, Oct. 12--13, 2015. The workshop explored in depth the latest developments on the determination of the QCD coupling $\alpha_s$ from 15 methods where high precision measurements are (or will be) available. Those include low-energy observables: (i) lattice QCD, (ii) pion decay factor, (iii) quarkonia and (iv) $\tau$ decays, (v) soft parton-to-hadron fragmentation functions, as well as high-energy observables: (vi) global fits of parton distribution functions, (vii) hard parton-to-hadron fragmentation functions, (viii) jets in $e^\pm$p DIS and $\gamma$-p photoproduction, (ix) photon structure function in $\gamma$-$\gamma$, (x) event shapes and (xi) jet cross sections in $e^+e^-$ collisions, (xii) W boson and (xiii) Z boson decays, and (xiv) jets and (xv) top-quark cross sections in proton-(anti)proton collisions. The current status of the theoretical and experimental uncertainties associated to each extraction method, the improvements expected from LHC data in the coming years, and future perspectives achievable in $e^+e^-$ collisions at the Future Circular Collider (FCC-ee) with $\cal{O}$(1--100 ab$^{-1}$) integrated luminosities yielding 10$^{12}$ Z bosons and jets, and 10$^{8}$ W bosons and $\tau$ leptons, are thoroughly reviewed. The current uncertainty of the (preliminary) 2015 strong coupling world-average value, $\alpha_s(m_Z)$ = 0.1177 $\pm$ 0.0013, is about 1\%. Some participants believed this may be reduced by a factor of three in the near future by including novel high-precision observables, although this opinion was not universally shared. At the FCC-ee facility, a factor of ten reduction in the $\alpha_s$ uncertainty should be possible, mostly thanks to the huge Z and W data samples available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision mechanical structure of an ultra-high-resolution spectrometer for inelastic X-ray scattering instrument

A method and an ultrahigh-resolution spectrometer including a precision mechanical structure for positioning inelastic X-ray scattering optics are provided. The spectrometer includes an X-ray monochromator and an X-ray analyzer, each including X-ray optics of a collimating (C) crystal, a pair of dispersing (D) element crystals, anomalous transmission filter (F) and a wavelength (W) selector crystal. A respective precision mechanical structure is provided with the X-ray monochromator and the X-ray analyzer. The precision mechanical structure includes a base plate, such as an aluminum base plate; positioning stages for D-crystal alignment; positioning stages with an incline sensor for C/F/W-crystal alignment, and the positioning stages including flexure-based high-stiffness structure.

36 MATERIALS SCIENCE↗

Mechanical design of multiple zone plates precision alignment apparatus for hard X-ray focusing in twenty-nanometer scale

An enhanced mechanical design of multiple zone plates precision alignment apparatus for hard x-ray focusing in a twenty-nanometer scale is provided. The precision alignment apparatus includes a zone plate alignment base frame; a plurality of zone plates; and a plurality of zone plate holders, each said zone plate holder for mounting and aligning a respective zone plate for hard x-ray focusing. At least one respective positioning stage drives and positions each respective zone plate holder. Each respective positioning stage is mounted on the zone plate alignment base frame. A respective linkage component connects each respective positioning stage and the respective zone plate holder. The zone plate alignment base frame, each zone plate holder and each linkage component is formed of a selected material for providing thermal expansion stability and positioning stability for the precision alignment apparatus.

36 MATERIALS SCIENCE↗

New physics implication of Higgs precision measurements

Studying the properties of the Higgs boson can be an important window to explore the physics beyond the Standard Model (SM). In this work, we present studies on the implications of the Higgs precision measurements at future Higgs Factories. We perform a global fit to various Higgs search channels to obtain the 95 % C.L. constraints on the model parameter spaces of Two Higgs Double Model (2HDM) and Minimal Supersymmetric Standard Model (MSSM). In the 2HDM, we analyze tree level effects as well as one-loop contributions from the heavy Higgs bosons. The strong constraints on $\cos(\beta-\alpha)$, heavy Higgs masses and their mass splitting are complementary to direct search of the LHC as well as possible future Z pole precision measurements. For the MSSM, we study both the Higgs couplings and mass precisions. The constraints on the CP-odd Higgs mass $m_A$ and stop mass scale $m_{SUSY}$ can be complementary to the direct search of HL-LHC. We also compare the sensitivity of various future Higgs factories, namely Circular Electron Positron Collider (CEPC), Future Circular Collider (FCC)-ee and International Linear Collider (ILC).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PRECISE™ PREconfiguring and Controlling Inverter SEt-points: A Solution for Easy Solar Integration

PRECISE™ is a software solution for preconfiguring solar inverter settings. It can be used by utilities and system operators to efficiently process new inverter applications at much less the time and effort, and with greater precision for settings that optimize stability and energy savings. PRECISE has received an R&D 100 award, and has been used to dramatically cut wait times and labor costs for new residential solar installations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

QONNX: Representing Arbitrary-Precision Quantized Neural Networks

We present extensions to the Open Neural Network Exchange (ONNX) intermediate representation format to represent arbitrary-precision quantized neural networks. We first introduce support for low precision quantization in existing ONNX-based quantization formats by leveraging integer clipping, resulting in two new backward-compatible variants: the quantized operator format with clipping and quantize-clip-dequantize (QCDQ) format. We then introduce a novel higher-level ONNX format called quantized ONNX (QONNX) that introduces three new operators -- Quant, BipolarQuant, and Trunc -- in order to represent uniform quantization. By keeping the QONNX IR high-level and flexible, we enable targeting a wider variety of platforms. We also present utilities for working with QONNX, as well as examples of its usage in the FINN and hls4ml toolchains. Finally, we introduce the QONNX model zoo to share low-precision quantized neural networks.

Pappalardo, Alessandro↗

Study of light $\Lambda$ hypernuclei using precision spectroscopy of charged mesonic decay pions at Jlab

We proposed to the JLAB PAC33 for studying the charged mesonic weak decay pions from ?-hypernuclei with a dedicated spectrometer. Due to large momentum transfer as well as high beam intensity, the quasi-free ? hypernuclear production yield will be much higher than that from other mechanisms with hadronic beams. Some of these highly excited systems from quasi-free production cascade instantaneously to variety of light hypernuclei, possible for certain highly exotic ones, through nucleon emission or fragmentation processes. The Lorentz boost will push most of the pion background to the forward direction, while most of the long lived hypernuclei stop in the thin target foil then decay weakly from ground or long lived low lying states. For light hypernuclei, charged pions from weak mesonic decay provide an excellent tool to measure the binding energy of these states as commonly done in emulsion experiments. The proposed experiment at JLAB can reach high resolution (~130 keV FWHM) and high precision (< ±20keV), both capable to exceed significantly the quality limit of emulsion data. The precision allows a recheck on the basic YN interaction models that were built and tested by emulsion results and a more accurate measurement of the charge symmetry breaking such as that often referred by ?B(4?H - 4?He). Secondly, the fragmentation process may be a better way to produce highly exotic neutron rich hypernuclei that are impossible to be produced directly from the primary reactions. Although heavy ion collision is planned to be used to search and study such hypernuclei, but the level of precision may be key factor. The talk will present the basic ideas of the proposal which was conditionally approved by PAC33 which recommended a beam test. A parasitic test run plan in Hall A will be presented.

Tang, Liguang↗

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗