Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Maximum Power Reference Tracking Algorithm for Power Curtailment of Photovoltaic Systems

This paper presents an algorithm for power curtailment of photovoltaic (PV) systems under fast solar irradiance intermittency. Based on the Perturb and Observe (P&O) technique, the method contains an adaptive gain that is compensated in real-time to account for moments of lower power availability. In addition, an accumulator is added to the calculation of the step size to reduce the overshoot caused by large irradiance swings. A testbed of a three-phase single-stage, 500 kVA PV system is developed on the OPAL-RT eMEGAsim real-time simulator. Field irradiance data and a regulation signal from PJM (RTO) are used to compare the performance of the proposed method with other techniques found in the literature. Results indicate an operation with smaller overshoot, less dc-link voltage oscillations, and improved power reference tracking capability.

Paduani, Victor↗

Arc-Jet Power Supply And Starting Circuit

Power efficiency high, current regulated, and starting automatic. New circuit for starting arc jets and controlling them in steady operation capable of high power efficiency and constructed in lightweight form. Feedback control system keeps arc-jet current nearly constant, once arc struck by starting pulse. Circuit made of commercially available components. Design capable of high power efficiency.

Gruber, Robert P.↗

High-frequency ac power distribution in Space Station

A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

Tsai, Fu-Sheng↗

Control system design for the MOD-5A 7.3 mW wind turbine generator

This paper provides descriptions of the requirements analysis, hardware development and software development phases of the Control System design for the MOD-5A 7.3 mW Wind Turbine Generator. The system, designed by General Electric Company, Advanced Energy Programs Department, under contract DEN 3-153 with NASA Lewis Research Center and DOE, provides real time regulation of rotor speed by control of both generator torque and rotor torque. A variable speed generator system is used to provide both airgap torque control and reactive power control. The wind rotor is designed with segmented ailerons which are positioned to control blade torque. The central component of the control system, selected early in the design process, is a programmable controller used for sequencing, alarm monitoring, communication, and real time control. Development of requirements for use of aileron controlled blades and a variable speed generator required an analytical simulation that combined drivetrain, tower and blade elastic modes with wind disturbances and control behavior. An orderly two phase plan was used for controller software development. A microcomputer based turbine simulator was used to facilitate hardware and software integration and test.

Barton, Robert S.↗

Closed loop dynamics of in-core thermionic reactor systems.

Use of a point model of an in-core thermionic converter to investigate alternative schemes for providing closed-loop reactor control. It was found that schemes based on variable-gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small; even for a complete electric load drop the emitter temperature transient is less than 100 K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that, even though the emitter temperature distribution is about 200 K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a networked hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAr regulation technologies as an example to illustrate system setups, communication requirements among different HIL simulation systems, and system connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

Xie, Fuhong↗

Data Integration and Visualization for Enhanced Resilience and Sustainability in Hydropower (DIVERS-H)

U.S. hydropower plants face potential threats from shrinking water supply, rising demands, and warmer stream temperatures from various causes. Power plant owners, operators, and regulators require new tools to take advantage of and interpret the diverse range of scientific data being produced by both observational methods (for example, satellite, radar, stream gauges) and computer modeling methods that evaluate and predict how earth's dynamic systems (atmosphere, oceans, land surface, and sea ice) are changing and interacting. Combining datasets such as these with AI-based analyses introduces a novel decision support system to help users anticipate and address potential impacts on power generation stations. This new technology has been named DIVERS-H for "Data Integration and Visualization for Enhanced Resilience and Sustainability in Hydropower." In Phase I, technical feasibility was established with the development and demonstration of all the new technologies that are required. Most notably, DIVERS-H will use new artificial intelligence (AI) methods to capture the complex dynamics of water availability, demand, and environmental changes. In addition, new data management software was developed, and a prototype user interface was implemented as the precursor to a full scale decision support system. With technical research complete, the project focus now shifts to development of a commercial software product to provide users with actionable insight into water availability and the risk/resilience of critical systems at their locations of interest. Although DIVER-H was originally conceived as a tool for hydroelectric power applications, the same underlying technology can be readily applied to other water-consuming systems including coal, natural gas, oil, and nuclear power plants.

Chaudhary, Aashish [Kitware, Inc., Clifton Park, N↗

Scheduler Modeling of IBR Plants for Providing Ancillary Services [SWR-25-16]

Inverter-based resources (IBRs) have been integral components of modern power systems and their capability in providing grid services have been widely studied. To promote the deployment of IBR grid services in real utility operation, this software proposes a scheduler model for IBRs. The energy and reserve are co-optimized in day-ahead, various ancillary services, including operating reserve provision, peak load reduction, voltage regulation and power factor control are integrated in the model.

Wang, Xiaofei [National Renewable Energy Laborator↗

Flexible Siting Criteria and Staff Minimization for Micro-Reactors

The economic potential of micro-reactors is vast and underestimated. Commonly-emphasized applications include niche markets such as remote communities, mines and military bases. However, micro-reactors could be used as flexible energy generators also for larger markets, such as mobile and containerized agriculture and manufacturing facilities, district heating, micro-grids for data centers, sea ports, airports and hospitals. The implication is that micro-reactors may have to be deployed also in non-remote locations. Successful implementation of micro-reactors needs a navigable and predictable licensing process, technology-appropriate siting restrictions, risk-informed emergency and safety requirements, and practical operating and maintenance requirements. The primary goal of this project was to develop siting criteria that are tailored to micro-reactors deployable in densely-populated areas, e.g., urban environments. To achieve that goal, we compared the characteristics of the MIT research reactor (MITR) with those of leading micro-reactor concepts (e.g., eVinci, USNC, Aurora), and evaluated whether and how the MITR design basis (e.g., inherent safety features, engineered safety systems, source term, emergency planning and emergency operating procedures) and associated regulations may be applicable to these new micro-reactors as well. What makes MITR a unique analogue in this context is its small power rating (6 MWt) and physical size, mode of operations (24/7 with a somewhat more commercial flavor than typical university reactors), and especially its urban location. Of course significant differences exist, such as mission (power production vs. research) and the reactor design itself. Leveraging the MITR experience, this project was able to generate criteria that will allow micro-reactors to realize their full economic potential as flexible heat and electricity generators for a diverse portfolio of applications in non-remote locations. As such, the outcome of this project might encourage investment in and use of micro-reactors. A second goal of the project was to conceptualize a model of operations for micro-reactors that would minimize the staffing requirements, and thus reduce the cost of electricity and heat generated by these systems. Here too our approach was to systematically review the MITR experience and requirements, as well as survey the innovations in autonomous control technologies and monitoring (e.g., advanced sensors, drones, robotics, AI) that would permit a dramatic reduction in staffing at future micro-reactor installations. The scope of work was expanded after the start date to include also an evaluation of micro-reactor security, using the so-called consequence-based analysis, and the development of a methodology to perform dynamic risk assessment for micro-reactors, using system theory and modeling and simulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of noise requirements on STOL propulsion system designs

The severity of proposed noise goals for STOL systems has resulted in a new design approach for aircraft propulsion systems. It has become necessary to consider the influence of the noise goal on the design of engine components, engine systems, and the integrated nacelle, separately and collectively, from the onset of the design effort. This integrated system design approach is required in order to effect an optimization of the propulsion and aircraft system. Results from extensive design studies and pertinent test programs are presented which show the effect of noise specifications on component and system design, and the trade offs possible of noise versus configuration and performance. The design optimization process of propulsion systems for powered lift systems is presented beginning with the component level and proceeding through to the final integrated propulsion system. Designs are presented which are capable of meeting future STOL noise regulations and the performance, installation and economic penalties are assessed as a function of noise level.

Rulis, R. J.↗

Influence of noise requirements on STOL propulsion system designs

The severity of proposed noise goals for STOL systems has resulted in a new design approach for aircraft propulsion systems. It has become necessary to consider the influence of the noise goal on the design of engine components, engine systems, and the integrated nacelle, separately and collectively, from the onset of the design effort. This integrated system design approach is required in order to effect an optimization of the propulsion and aircraft system. Results from extensive design studies and pertinent test programs are presented which show the effect of noise specifications on component and system design, and the trade-offs possible of noise versus configuration and performance. The design optimization process of propulsion systems for powered lift systems is presented beginning with the component level and proceeding through to the final integrated propulsion system. Designs are presented which are capable of meeting future STOL noise regulations and the performance, installation and economic penalties are assessed as a function of noise level.

Rulis, R. J.↗

Influence of noise requirements on STOL propulsion system designs

The severity of proposed noise goals for STOL systems has resulted in a new design approach for aircraft propulsion systems. It has become necessary to consider the influence of the noise goal on the design of engine components, engine systems, and the integrated nacelle, separately and collectively, from the onset of the design effort. This integrated system design approach is required in order to effect an optimization of the propulsion and aircraft system. Results from extensive design studies and pertinent test programs are presented which show the effect of noise specifications on component and system design, and the trade-offs possible of noise versus configuration and performance. The design optimization process of propulsion systems for powered lift systems is presented beginning with the component level and proceeding through to the final integrated propulsion system. Designs are presented which are capable of meeting future STOL noise regulations and the performance, installation and economic penalties are assessed as a function of noise level.

Rulis, R. J.↗

Electrical power generating system

An alternating current power generation system adopted to inject power in an already powered power line is discussed. The power generating system solves to adjustably coup an induction motor, as a generator, to an ac power line wherein the motor and power line are connected through a triac. The triac is regulated to normally turn on at a relatively late point in each half cycle of its operation, whereby at less than operating speed, and thus when the induction motor functions as a motor rather than as a generator, power consumption from the line is substantially reduced. The principal application will be for windmill powered generation.

Nola, F. J.↗

Flight-test of the glide-slope track and flare-control laws for an automatic landing system for a powered-lift STOL airplane

An automatic landing system was developed for the Augmentor Wing Jet STOL Research Airplane to establish the feasibility and examine the operating characteristics of a powered-lift STOL transport flying a steep, microwave landing system (MLS) glide slope to automatically land on a STOL port. The flight test results address the longitudinal aspects of automatic powered lift STOL airplane operation including glide slope tracking on the backside of the power curve, flare, and touchdown. Three different autoland control laws were evaluated to demonstrate the tradeoff between control complexity and the resulting performance. The flight test and simulation methodology used in developing conventional jet transport systems was applied to the powered-lift STOL airplane. The results obtained suggest that an automatic landing system for a powered-lift STOL airplane operating into an MLS-equipped STOL port is feasible. However, the airplane must be provided with a means of rapidly regulation lift to satisfactorily provide the glide slope tracking and control of touchdown sink rate needed for automatic landings.

Watson, D. M.↗

Two-Stage Series-Resonant Inverter

Two-stage inverter includes variable-frequency, voltage-regulating first stage and fixed-frequency second stage. Lightweight circuit provides regulated power and is invulnerable to output short circuits. Does not require large capacitor across ac bus, like parallel resonant designs. Particularly suitable for use in ac-power-distribution system of aircraft.

Stuart, Thomas A.↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Summary of Technical Peer Review on the Risk Assessment Framework proposed in Report INL/RPT-22-68656 for Digital Instrumentation and Control Systems

This report summarizes the peer review activities initiated by Idaho National Laboratory (INL) during fiscal year (FY) 2023 for the evaluation and improvement of the methodology developed under the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) risk assessment project. In FY 2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a technical basis to support effective and secure DI&C technologies for digital upgrades/designs. A framework was proposed for this strategy, which aims to (1) provide a best-estimate, risk-informed capability to quantitatively and accurately estimate the risk impact of plant modernization, considering the introduction of high safety-significant safety-related (HSSSR) DI&C systems, (2) support and supplement existing risk-informed DI&C design guides by providing quantitative risk information and evidence, (3) offer a capability of design architecture evaluation of various DI&C systems, (4) assure the long-term safety and reliability of HSSSR DI&C systems, and (5) reduce uncertainty in costs and support integration of DI&C systems in the plant. The R&D efforts of this project from FY 2019 through FY 2022 were focused on methodology improvement and demonstration of the proposed framework for the risk assessment and design optimization of safety-critical DI&C systems. Collaborations with the nuclear industry have been initiated to support the reliability and risk assessment of their DI&C systems by using the proposed framework. In FY 2023, the framework has reached to a point for a technical peer review and obtain stakeholder feedback. This peer review activity includes coordination of the reviews performed by a group of industry stakeholders, documentation of the peer review suggestions, providing resolutions and responses to the peer review comments. The objective of this technical peer review is to obtain representative feedback on the proposed framework to improve the technical qualities of its methodology and readiness for deployment to the industry. Feedback may identify potential areas for improvement and further development. The Subject Matter experts were invited to review the latest project report documenting the methodology developed in the project and provide evaluations of the technical qualities of the proposed framework and relevant methods. The reviewed project report is “An Integrated Framework for Risk Assessment of High Safety-significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants: Methodology and Demonstration” INL/RPT-22-68656 (short as “INL/RPT-22-68656” in this report). This peer review report documents the technical questions provided for technical peer review and introduces the technical peer reviewers from the stakeholders including nuclear utilities, regulators, and universities. Comments from technical peer reviewers and the resolutions and responses to these comments are outlined. Insights and lessons learned from the technical peer review are summarized in conclusions and future work. The primary audience of this report are DI&C designers, engineers, and probabilistic risk assessment (PRA) practitioners. This includes stakeholders, such as the nuclear utilities and regulators who consider the deployment and upgrade of DI&C systems, DI&C software developers and reviewers, and cybersecurity specialists.

99 GENERAL AND MISCELLANEOUS↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗