Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Clear Sky Toolkit: Decision Support User Guide

The Clear Sky Decision Support Template is a Microsoft Excel-based resource that enables users to screen and prioritize critical facilities for the addition of solar + storage. The Decision Support Template consolidates and streamlines the most relevant resources from the emergency management discipline, the electric utility sector, and national energy research institutions to assist in further site analysis and decision-making. The Decision Support Template is intended for use by local government and private sector decision-makers who aim to mitigate the effects of power outages on critical infrastructure, understand the potential for deploying photovoltaic (PV) and storage solutions on critical facilities, and align emergency management planning processes and utility needs with community resilience objectives. The Decision Support Template is divided into five modules that provide a structured, step-by-step approach users can follow and apply to unique circumstances. This process guides a more thorough and accurate assessment of a site's potential to accommodate a solar + storage system, provide grid benefits to utilities, and support community resilience and disaster mitigation for the broader region. After identifying potentially viable and preferred sites for solar + storage using the Decision Support Template, users should conduct a more detailed evaluation and consultation with a solar professional.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilizing HYSPLIT for Emergency Response Modeling at SRS

At SRS, emergency responders use a variety of tools to detect, track, and mitigate hazardous material releases into the atmosphere. Two models currently used at SRS are Puff-Plume and the Lagrangian Particle Dispersion Model (LPDM), a Gaussian and Lagrangian model, respectively. A decision has been made to replace LPDM with the more widely-supported Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model for evaluating inhalation and ingestion doses following a release. HYSPLIT is designed to compute complex dispersion and deposition simulation To achieve the implementation of HYSPLIT, we have developed a preliminary UI framework that will allow HYSPLIT to be run on ATG computers without the need for active network connections, thus avoiding the loss of capabilities in the event of a network outage during an emergency.

Earley, Ian↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Resilience for Mission Assurance: Case Study Scoping Document

The Energy Resilience for Mission Assurance (ERMA) project—a Department of Energy Grid Modernization Lab Consortium effort carried out via a partnership among five national laboratories— seeks to develop metrics to quantify how improvements to energy system resilience translate to improved Department of Defense (DoD) mission assurance (MA) during wide-scale, long-duration outages of the bulk power system. DoD missions are integral to national security and highly dependent on electric power. However, energy system planners—both civilian and military—lack a clear and quantifiable mapping between electric power system resilience and MA, leaving a gap in their ability to understand and consider national security outcomes within their planning efforts. The ERMA project seeks to fill this gap, providing stakeholders with new capabilities to understand the impact of electric power system resilience on MA during hazard scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Burnup BWR LOCA Burst Analysis Framework Development and Demonstration

Nuclear power currently contributes approximately 20% of total electricity generation in the United States and more than 10% globally. Given the increasing reliance on nuclear energy to achieve our nation’s goal of reaching net-zero carbon emissions by 2050, there is significant pressure on the existing nuclear industry to extend plant operational licenses and improve efficiency. This is crucial as the existing nuclear fleet serves as a vital bridge until new light water and advanced reactors can be developed and deployed, bolstering the supply of carbon-free energy to meet domestic demands. Operational costs primarily consist of plant operation and maintenance and fuel costs, influenced by materials and reactor core designs. These factors, coupled with heavily subsidized renewable energy markets, create a challenging economic environment for the existing light water reactor fleet, as well as for new build projects. To address these economic challenges, the nuclear industry has developed a strategic blueprint aimed at enhancing nuclear power’s economic sustainability. Past initiatives, such as efforts to eliminate fuel failures by 2010 and reduce operating costs by 30% before 2020, have laid the groundwork. Optimizing core design parameters, including burnup limits and enrichment levels, can lengthen cycles, reduce outages, reduce batch reload batch fractions and spent fuel storage requirements, and lower maintenance and operating expenses, thereby enhancing economic viability. In the United States, boiling water reactors (BWRs) comprise approximately one-third of the fleet, although much of the research and development focus has traditionally been on pressurized water reactors (PWRs). Advances in modeling and simulation, particularly through the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, are crucial to the long-term viability of BWRs, just as they are for PWRs. A key research area of the high burnup/increased enriched fuel initiative is focused on addressing loss-of-coolant-accident (LOCA)-related issues. NEAMS has dedicated significant effort to enhancing tools to better support BWRs, with a current focus on showcasing the BWR framework for high-burnup LOCA analysis. This high-fidelity work will demonstrate a best estimate pin-by-pin high-burnup BWR LOCA analysis to assess full-core cladding rupture behavior. This modeling capability will help with better understanding and realistic evaluation of fuel fragmentation, relocation, and dispersal (FFRD) phenomena at BWRs, which then could be used to prevent FFRD at BWRs without penalizing operational parameters. In addition, the results of this work will help identify strategies to identify additional margins or to potentially limit cladding rupture through core design optimizations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Current Practices in Distribution Utility Resilience Planning for Wildfires

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines major events as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on major event days, and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on wildfires. Standalone reports focusing on severe storms (including hurricanes and non-winter storms) and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Current Practices in Distribution Utility Resilience Planning for Hurricanes and Non-Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines "major events" as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on "major event days" and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common recommended resilience components that we have identified in existing resilience frameworks. The focus of this report is on hurricanes and severe storms in which the primary hazards are precipitation or high winds. We exclude winter storms with primary hazards of ice and extreme cold, as they are a unique set of hazards with different resilience considerations. Standalone reports focusing on wildfires and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

36 MATERIALS SCIENCE↗

Saltstone Paddles and Augers Materials of Construction Study

The Saltstone Production Facility (SPF) uses a 10-inch READCO continuous, co-rotating twin-screw mixer to mix the dry premix with the low-level radioactive waste (LLW) salt solution to produce fresh saltstone grout. The paddles and augers within the mixer degrade via erosion in the region where the salt solution is introduced into the mixer. After the paddles/augers erode to a point where the throughput impacts operations, the mixer is disassembled, the effected paddles/augers are replaced, and the mixer is reassembled. Saltstone Engineering indicated that this effort requires an approximately three-week outage. The objective of this task is to assess alternative materials of construction (MOCs) that will provide better erosion characteristics and decrease the frequency in which the paddles and augers need replacement. Previous Astralloy V studies looked only at Charpy Impact and Rockwell Hardness Testing. Each of these will be examined for different alloys as well as Miller Testing (abrasion to determine wear) which will provide a good assessment of an alloy’s erosion/wear characteristics. The following facts concerning the current and proposed alloys for Saltstone Paddles and Augers are provided in this report. • Current Astralloy V material and alloy E52100 had the most favorable Miller Testing Results. • Charpy Impact Testing did not correlate with Miller Testing Results. • Hardness Testing correlated with Miller Testing results meaning that higher hardness will provide more favorable wear resistance. • Further investigation of E52100 and various tool grade steels is recommended for achieving wear resistant properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

The Iowa Tribe of Kansas and Nebraska: Advancing Clean, Resilient, and Sovereign Energy (Summary Report of Communities LEAP Activities)

The Iowa Tribe of Kansas and Nebraska (ITKN) is a federally recognized Native American Tribe located along the Missouri River on the border of northeast Kansas and southeastern Nebraska. There are over 800 residents (Tribal citizens and non-Tribal) who live on the reservation, as well as more than 500 people who visit or work on the reservation on a daily basis. The ITKN faces many energy challenges, including rising service costs and dozens of power outages annually that impact resident well-being and business activities on Tribal lands. Power service issues are made more challenging by the remoteness of the reservation, which is 20 miles from the nearest town. Despite this, the ITKN has a long history of cultural and economic resilience: Local self-reliance, environmental stewardship, respecting the carrying capacity of the land, and strengthening the community are Tribal communities' traditional strengths. Long-term energy goals for the ITKN are centered around achieving energy sovereignty. Priority actions include: (1) Establishing a Tribal Utility Authority (TUA) to promote social welfare and community development.; (2) Deploying renewable community microgrids with ground-mount solar arrays and sustainable energy storage systems to advance energy sovereignty, resilience, and reliability. To advance these goals, the ITKN partnered with the U.S. Department of Energy's (DOE's) Communities LEAP (Local Energy Action Program) pilot. From August 2022 to March 2024, the ITKN community coalition collaborated with technical assistance providers at DOE's National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to evaluate TUA planning needs and microgrid deployment scenarios. This final report details the Communities LEAP technical assistance process, models and analysis performed, and results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗