Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗

Enhancing Early Systems R&D Capabilities with Systems —Theoretic Process Analysis

Systems engineering today faces a wide array of challenges, ranging from new operational environments to disruptive technological — necessitating approaches to improve research and development (R&D) efforts. Yet, emphasizing the Aristotelian argument that the “whole is greater than the sum of its parts” seems to offer a conceptual foundation creating new R&D solutions. Invoking systems theoretic concepts of emergence and hierarchy and analytic characteristics of traceability, rigor, and comprehensiveness is potentially beneficial for guiding R&D strategy and development to bridge the gap between theoretical problem spaces and engineering-based solutions. In response, this article describes systems–theoretic process analysis (STPA) as an example of one such approach to aid in early-systems R&D discussions. STPA—a ‘top-down’ process that abstracts real complex system operations into hierarchical control structures, functional control loops, and control actions—uses control loop logic to analyze how control actions (designed for desired system behaviors) may become violated and drive the complex system toward states of higher risk. By analyzing how needed controls are not provided (or out of sequence or stopped too soon) and unneeded controls are provided (or engaged too long), STPA can help early-system R&D discussions by exploring how requirements and desired actions interact to either mitigate or potentially increase states of risk that can lead to unacceptable losses. This article will demonstrate STPA's benefit for early-system R&D strategy and development discussion by describing such diverse use cases as cyber security, nuclear fuel transportation, and US electric grid performance. Together, the traceability, rigor, and comprehensiveness of STPA serve as useful tools for improving R&D strategy and development discussions. In conclusion, leveraging STPA as well as related systems engineering techniques can be helpful in early R&D planning and strategy development to better triangulate deeper theoretical meaning or evaluate empirical results to better inform systems engineering solutions.

42 ENGINEERING↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Conceptual Fuel Element Design Candidates for Conversion of High Flux Isotope Reactor with Low-Enriched Uranium Silicide Dispersion Fuel

Engineering design studies are underway to assess the feasibility of converting the High Flux Isotope Reactor (HFIR) to operate with low-enriched uranium (LEU) silicide dispersion (U3Si2-Al) fuel. These studies are supported by the U.S. Department of Energy National Nuclear Security Administration’s Office of Material Management and Minimization. A systematic approach employing neutronic and thermal-hydraulic analyses have been performed with the ORNL Shift and HFIR Steady State Heat Transfer Code tools, respectively, to predict reactor performance and thermal safety margins for proposed LEU3Si2-Al fuel designs. The design process was initiated by generating an optimized design with fabrication features identified from previous studies that result in excellent performance and safety metrics. The approach continued by substituting a single fabrication feature anticipated to be difficult to manufacture with another feature expected to perform an analogous function to that of the removed feature. Four conceptual fuel element design candidates, with various fabrication features, for conversion of HFIR with 4.8 gU/cm3 LEU3Si2-Al fuel have been generated and shown to meet pre-defined performance and safety metrics. Results to date indicate that HFIR could convert with the subject fuel system and meet performance and safety requirements if, among other considerations, fabrication of the specific design features are demonstrated and qualification of the fuel is complete under HFIR-specific conditions.

Chandler, David↗

Toward digital design at the exascale: An overview of project ICECap

High performance computing has entered the Exascale Age. Capable of performing over 1018 floating point operations per second, exascale computers, such as El Capitan, the National Nuclear Security Administration's first, have the potential to revolutionize the detailed in-depth study of highly complex science and engineering systems. However, in addition to these kind of whole machine “hero” simulations, exascale systems could also enable new paradigms in digital design by making petascale hero runs routine. Currently, untenable problems in complex system design, optimization, model exploration, and scientific discovery could all become possible. Motivated by the challenge of uncovering the next generation of robust high-yield inertial confinement fusion (ICF) designs, project ICECap (Inertial Confinement on El Capitan) attempts to integrate multiple advances in machine learning (ML), scientific workflows, high performance computing, GPU-acceleration, and numerical optimization to prototype such a future. Built on a general framework, ICECap is exploring how these technologies could broadly accelerate scientific discovery on El Capitan. In addition to our requirements, system-level design, and challenges, we describe some of the key technologies in ICECap, including ML replacements for multiphysics packages, tools for human-machine teaming, and algorithms for multifidelity design optimization under uncertainty. As a test of our prototype pre-El Capitan system, we advance the state-of-the art for ICF hohlraum design by demonstrating the optimization of a 17-parameter National Ignition Facility experiment and show that our ML-assisted workflow makes design choices that are consistent with physics intuition, but in an automated, efficient, and mathematically rigorous fashion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Apparatus for Neutron Capture Measurements on Extra Small Radioactive Samples: The DICER Instrument at LANSCE

We report the neutron capture cross section, the probability per unit area a neutron is absorbed by a nucleus followed by the emission of gamma ray(s), is an important quantity in several fields such as astrophysics, nuclear criticality safety, radiochemical diagnostics, nuclear medicine, nuclear forensics and nuclear security. Accurate knowledge of how neutrons interact with matter is a crucial component to understand physical processes in depth. A great example is the understanding of how our universe was created, a quest that requires accurate modeling in which neutron capture cross sections are a key ingredient

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

Identifying neutron sources using recoil and time-of-flight spectroscopy

Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4⁢𝜎) at event counts as low as ∼10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.

neutron physics↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

Performance Portable Graphics Processing Unit Acceleration of a High-Order Finite Element Multiphysics Application

The Lawrence Livermore National Laboratory (LLNL) will soon have in place the El Capitan exascale supercomputer, based on advanced micro devices (AMD) graphics processing units (GPUs). As part of a multiyear effort under the National Nuclear Security Administration (NNSA) Advanced Simulation and Computing (ASC) program, we have been developing marbl, a next generation, performance portable multiphysics application based on high-order finite elements. In previous years, we successfully ported the Arbitrary Lagrangian–Eulerian (ALE), multimaterial, compressible flow capabilities of marbl to nvidia GPUs as described in Vargas et al. Here, in this paper, we describe our ongoing effort in extending marbl's GPU capabilities with additional physics, including multigroup radiation diffusion and thermonuclear burn for high energy density physics (HEDP) and fusion modeling. We also describe how our portability abstraction approach based on the raja Portability Suite and the mfem finite element discretization library has enabled us to achieve high performance on AMD based GPUs with minimal effort in hardware-specific porting. Throughout this work, we highlight numerical and algorithmic developments that were required to achieve GPU performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supplemental Structural Analyses Used in Support of Certification of the Defense Programs Package 3

The Defense Programs Package (DPP)-3 is to be certified by the National Nuclear Security Administration (NNSA) Packaging and Transportation Division (PTD). Certification is based on successful physical testing of the package, and six certification test units (CTUs) have been subjected to the normal conditions of transport (NCT) and hypothetical accident conditions (HAC) outlined in Title 10 of the Code of Federal Regulations Part 71 (10 CFR 71). During regulatory testing of one of the CTUs, the drum lid closure bolt closest to the impact surface failed during the HAC 30-ft side drop. One of the testing goals for this CTU was to minimize the thermal pathway from the drum exterior shell to the containment vessel (CV) flange and O-rings, leading to the maximum damage scenario in preparation for thermal testing at 1475 °F. Therefore, the puncture bar impact proceeded as originally planned by striking the side wall of the package exterior closest to the location of the CV flange. This puncture bar impact did not attempt to exploit the region of the failed drum lid closure bolt to potentially cause more damage to the package. After the conclusion of regulatory testing, the DPP-3 package finite element model was used to numerically evaluate the effects of puncture bar impacts to the drum exterior in the vicinity of the failed drum lid closure bolt to further demonstrate the robustness of the DPP-3 design. Three alternate puncture bar impact locations and orientations were evaluated to demonstrate that these puncture bar impacts would not substantially reduce the effectiveness of the DPP-3 packaging. This paper describes the supplemental finite element models performed and structural analysis results that demonstrate the alternate HAC 40-in. puncture bar impact tests would have no deleterious effect on the performance of the DPP-3.

Sakalaukus Jr., Peter J.↗

Strengthening the US Department of Energy’s Recruitment Pipeline: The DOE/NNSA Predictive Science Academic Alliance Program (PSAAP) Experience

The US Department of Energy (DOE) oversees a system of 17 national laboratories responsible for developing unique scientific capabilities beyond the scope of academic and industrial institutions. These labs strive to keep America at the forefront of discovery and are home to some of the Nation’s best minds and the world’s best scientific and research facilities. Collaborations between national laboratories and academic institutions are critical to develop and recruit talent for the DOE workforce. Academia’s cooperative education model poses challenges for DOE recruitment pipelines centered around traditional internships. This paper discusses a promising DOE recruitment pipeline, the National Nuclear Security Administration’s (NNSA) Predictive Science Academic Alliance Program (PSAAP) initiative. As a part of this, experiences capturing the successes and challenges faced by the University of Utah’s Carbon Capture Multidisciplinary Simulation Center (CCMSC) through their participation in the PSAAP-II initiative are shared. These experiences demonstrate the success of Utah’s PSAAP center as a recruitment pipeline with approximately 43% of CCMSC students going to a national laboratory after graduation. Potential opportunities to strengthen the DOE’s recruitment pipeline are also discussed.

Holmen, John↗

Gemma

Gemma is a linear electromagnetic code developed at Sandia National Laboratories based on the method of moments in the frequency domain, with the objective of supporting next-generation high-performance computing (HPC) platforms. Gemma provides full-wave computational electromagnetic modeling. As an example, Gemma models electromagnetic radiation (EMR) environments, including those resulting from radar (both hostile and friendly) and high-power-electromagnetic (HPEM) sources. Gemma refers to a suite of source code and scripts that aid in compiling, running, and testing the primary Gemma executable, which can be compiled for diverse platforms including CPUs, GPUs, and MICs by leveraging Sandia's Kokkos library.SAND2019-15221 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Zinser, Brian↗

miniGAN: a proxy application for generative adversarial networks

miniGAN is a python-based machine learning proxy application for generative adversarial networks, developed through the Exascale Computing Project's (ECP) ExaLearn project. It will be included in the main ECP proxy application and the machine learning proxy application suite. It is a proxy for ECP cosmological(CosmoFlow, ExaGAN) and wind energy(ExaWind) applications. miniGAN will be distributed to ECP hardware vendors as part of hardware codesign. miniGAN uses the Numpy/PyTorch/TensorFlow/Keras/Horovod frameworks and libraries. It also relies on the Kokkos and Kokkos-Kernels packages developed here at Sandia Labs. SAND2020-2038 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Ellis, John↗