Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

Bubble Distribution in Fused Obsidian and Slide Glass: Research Report - 12

In this report we obtain further data about the distri­bution of bubbles in glass. It gives the results obtained from the microscopic study of obsidian samples heated with an oxyacetylene torch and from powdered microscopic slide glass re-fused in an electric oven. This report continues our earlier study of the distributions: Badri Aghassi, 1961, B.U. Tektite Project, Research Report No. 11.

Aghassi, Badri↗

Results of examination of the returned Surveyor 3 samples for particulate impacts

The television housing and a section of the strut of the radar altimeter and Doppler velocity sensor were examined optically and with a scanning electron microscope for particulate impacts. The white surface of the camera was discolored during the months the Surveyor 3 was on the moon; however, most of the craters must have occurred as a result of lunar dust sandblasted by the LM exhaust. The polished section of the strut exhibits contamination which appears brown and seems to be partially composed of crystals. Electron microscopic analysis of the strut section indicated no craters of hypervelocity impact origin, confirmed pitting density results of the optical scans, and indicated that material in the craters is of lunar origin. No meteorite impacts larger than 25 microns were detected on the tubing section.

Cour-Palais, B. G.↗

Interval scanning photomicrography of microbial cell populations.

A single reproducible area of the preparation in a fixed focal plane is photographically scanned at intervals during incubation. The procedure can be used for evaluating the aerobic or anaerobic growth of many microbial cells simultaneously within a population. In addition, the microscope is not restricted to the viewing of any one microculture preparation, since the slide cultures are incubated separately from the microscope.

Casida, L. E., Jr.↗

Microstructural study of the nickel-base alloy WAZ-20 using qualitative and quantitative electron optical techniques

The NASA nickel-base alloy WAZ-20 was analyzed by advanced metallographic techniques to qualitatively and quantitatively characterize its phases and stability. The as-cast alloy contained primary gamma-prime, a coarse gamma-gamma prime eutectic, a gamma-fine gamma prime matrix, and MC carbides. A specimen aged at 870 C for 1000 hours contained these same constituents and a few widely scattered high W particles. No detrimental phases (such as sigma or mu) were observed. Scanning electron microscope, light metallography, and replica electron microscope methods are compared. The value of quantitative electron microprobe techniques such as spot and area analysis is demonstrated.

Young, S. G.↗

Use of LEED, Auger emission spectroscopy and field ion microscopy in microstructural studies.

The studies reported were conducted to gain a fundamental understanding of adhesion and dynamic friction on an atomic or microscopic level. Fundamental aspects of low energy electron diffraction (LEED), Auger emission spectroscopy (AES), and field ion microscopy (FIM) are discussed. Typical results of studies conducted are considered, giving attention to LEED-AES experiments, pin and disk experiments, and field ion microscope investigations.

Ferrante, J.↗

Turbulent heating of colliding streams in the solar wind.

Turbulent heating of colliding plasma streams has previously been observed in the solar wind. The original data were interpreted in terms of a fluid model. It is contended that a plasma-kinetic description is the more appropriate theoretical approach and is necessary in order to better understand the microscopic physical phenomena that underlie all fluid models. Microscopic solar-wind parameters characteristic of conditions during the observations were used, together with the quasi-linear plasma-kinetic theory, to compute the expected magnetic field and temperature enhancements in the interaction region between two counterstreaming plasma beams. The physical mechanism of excitation is the electromagnetic two-stream instability in which Alfven waves are unstable. A total field in the interaction region of about 8 gamma and a change in temperature of about 100,000 K are obtained.

Goldstein, M. L.↗

Service life of metals at low temperatures

Current concepts of the nature of fatigue failure at low temperatures are presented on the basis of experimental results of various investigators. The fundamental approach to the technique for studying low-temperature fatigue is examined. The necessity for using the same medium at different fatigue test temperatures and also the necessity for taking into account the magnitude of the plastic deformation amplitude are confirmed. Experimental data from a study of the influence of low temperatures (down to liquid nitrogen temperatures) on the fatigue life of copper and armco-iron in dry air, over a wide range of deformations, are presented. These results are compared with microscopic and electron microscopic pictures of the surface of the deformed specimens.

Verkin, B. I.↗

The Willowbar meteorite

Results of microscopic and electron microprobe analyses of a meteorite which fell near Willowbar, Okla., in December 1971. Microscopic examination confirmed the differences in structure which could be seen on the cut faces. Three distinct regions could be recognized: unblackened, blackened, and black veins. Microprobe analyses of the silicate grains in the Willowbar meteorite show that it is an L chondrite. The lack of well-defined chondrules and the large size of the maskelynite grains suggests that it is a type 6 chondrite according to the classification of Van Schmus and Wood (1967). It also has large black veins of the same composition as the matrix, and thus it might best be described as a shock-brecciated L6 chondrite.

Lange, D. E.↗

Applications of cryogenics in electron microscopy

Description of research and development efforts which resulted in a high-voltage cryoelectron microscope system capable of consistent operation at 1.8 to 4.2 K. Attention is given to the design and operation of superconducting objective lenses providing enhanced resolution during longer exposure times at lower beam intensities (thus reducing radiation damage of specimens). A specific system described combines a closed-cycle superfluid helium refrigerator integrated with a modified 200 kV electron microscope. Consistent resolutions of 8 to 16 A are attained with significantly reduced radiation damage, contamination, and thermal noise in prolonged vibration-free examination of specimens at temperatures from 1.8 to 4.2 K. Applications in specific disciplines are discussed, including membrane ultrastructure, cryobiology, microelectronics, and general superconductivity research.

Fernandez-Moran, H.↗

Physical effects in cavitating flows

The microscopic and macroscopic aspects of the physical effects of cavitating flows are discussed. The microscopic features are related to the properties of nuclei in liquids and to the moderate tensile strengths which are usually encountered in flows. The macroscopic features are concerned with the growth of vapor or gaseous cavities from a small initial size and with their eventual collapse. Mathematical models are developed to analyze the characteristics of: (1) tensile strength in liquids, (2) growth of vapor bubbles, and (3) collapse of vapor bubbles.

Plesset, M. S.↗

Lunar polymict breccia 14321 - A petrographic study

A detailed description is given of the petrology and mineralogy of lunar polymict breccia 14321, which was returned from the Fra Mauro formation on the Apollo 14 mission. Electron probe microanalysis and microscopic studies were made of seven petrographic thin sections of the rock. Three broad genetic classes were found in the thin sections: (1) rounded fragments of pre-existing microbreccia with microscopically recognizable crystal and lithic fragments incorporated in a dark matrix; (2) igneous rock fragments of basaltic composition; and (3) a light colored, somewhat friable matrix which cements the other two classes. The components are classified according to chemical, mineralogical textural, and chronological criteria.

Grieve, R. A.↗

Interface markings in crystals experiment MA-060

Doped germanium single crystals with interface demarcation were successfully grown during the Apollo Soyuz Test Project mission. Interface demarcation permitted the determination of the microscopic growth behavior from the onset to the termination of solidification. Preliminary segregation analysis shows striking differences in segregation in the presence of gravity. The correlation between microscopic growth rate behavior and the composition of the solid on the microscale is being evaluated.

Gatos, H. C.↗

Some wear studies on aircraft brake systems

An initial investigation of worn surfaces in friction pads and steel rotors used in current aircraft brakes was carried out using electron microprobe and X-ray diffraction analysis. It consists of the topographical study and the analysis of chemical element distribution. Based upon this initial examination, two approaches, microscopic and macroscopic have been conducted to interpret and formulate the wear mechanism of the aircraft brake materials. Microscopically, the wear particles were examined. The initiation and growth of surface cracks and the oxidation were emphasized in this investigation. Macroscopically, it has been found that, for the current copper based brake material sliding against 17-22 AS steel in a caliper brake, the surface temperature raised due to frictional heat is nonlinearly proportional to the load applied and slide time with speed at 1750 rpm. The wear of brake materials is then proportional to this temperature and is also a function of the melting temperature for copper.

Ho, T. L.↗

Oxidation of metals and alloys in controlled atmospheres using in situ transmission electron microscopy and Auger spectrography

Single-crystalline thin films of copper were oxidized at an isothermal temperature of 425 C and at an oxygen partial pressure of .005 Torr in situ in a high-resolution electron microscope. The specimens were prepared by epitaxial vapor deposition onto polished 100 and 110 faces of rocksalt and mounted in a hot stage inside an ultra-high-vacuum specimen chamber of the microscope. Large amounts of sulfur, carbon, and oxygen were detected by Auger electron spectroscopy on the surface of the as-received films and were removed in situ by ion-sputter etching immediately prior to the oxidation. The nucleation and growth characteristics of Cu2O on Cu were studied. Results show that neither stacking faults nor dislocations are associated with the Cu2O nucleation sites. The growth of Cu2O nuclei is linear with time. The experimental findings, including results from oxygen dissolution experiments and from repetitive oxidation-reduction-oxidation sequences, fit well into the framework of an oxidation process involving (a) the formation of a surface-charge layer, (b) oxygen saturation in the metal and (c) nucleation, followed by surface diffusion of oxygen and bulk diffusion of copper for lateral and vertical oxide growth, respectively.

Rao, D. B.↗

The effect of intermediate-scale motions on line formation

The problem of LTE and non-LTE line formation in the presence of nonthermal velocity fields with geometric scales between the microscopic and macroscopic limits is investigated in the cases of periodic sinusoidal and sawtooth waves. For a fixed source function (the LTE case), it is shown that time-averaged line profiles progress smoothly from the microscopic to the macroscopic limits as the geometric scale of the motions increases, that the sinusoidal motions produce symmetric time-averaged profiles, and that the sawtooth motions cause a redshift. In several idealized non-LTE cases, it is found that intermediate-scale velocity fields can significantly increase the surface source functions and line-core intensities. Calculations are made for a two-level atom in an isothermal atmosphere for a range of velocity scales and non-LTE coupling parameters and also for a two-level atom and a four-level representation of Na I line formation in the Harvard-Smithsonian Reference Atmosphere (1971) solar model. It is found that intermediate-scale velocity fields in the solar atmosphere could explain the central intensities of the Na I D lines and other strong absorption lines without invoking previously suggested high electron densities.

Shine, R. A.↗